Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹9.5 L+₹2.4 L (33.6%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest |
Tender Value
₹10.3 L
EMD Value
₹20,600
Closing Date
1 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer I (P) Fy Kirkee
8, ENGINE HOUSE ROAD, ORDNANCE ESTATE, KIRKEE, PUNE-411003
REPAIR/MAINTENANCE OF EXTERNAL SERVICES WITH ALLIED WORKS AT PTL UNDER CQA(A) KIRKEE
2020_MES_321197_2
8603
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kirkee
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer I (P) Fy Kirkee
₹20,600
Yes
20 Aug 2020
17 Jun 2020
8 Jul 2020
17 Jun 2020
1 Jul 2020
19 Jun 2020
60 days
Amount
Supply, laying, connecting, testing and commissioning in trenches/through pipes or bare in road crossings/paths/drains/ducts/floors/ along poles/equipments etc, testing and commissioning of Cable under ground, LT, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium multi stranded conductor,1100V grade of 3.5 core 35 sqmm cross sectional area. NOTE Excavation/earthwork, sand for cushioning, protection pipe cable covers shall be measured and paid separately. Unit rates quoted shall be deemed to be inclusive of disconnecting and taking out old unserviceable cable, protection pipe etc.
All as per item No 1 herein before but size of cable16 Sqmm 4 core
All as per item No 1 herein before but size of cable 6 Sqmm 2 core
Laying only Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable with stranded aluminium conductor 1100 Volt grade of size 300 Sqmm 3.5 core complete including connecting and testing all as specified and directed. Locations : PTL ,CQA and Offr Md Accn Area as directed NOTES (i) Excavation/earthwork, sand for cushioning, protection pipe cable covers shall be measured and paid separately. (ii) Unit rates quoted shall be deemed to be inclusive of disconnecting and taking out old unserviceable cable, protection pipe etc. (iii) Cable shall be issued under Sch B from AGE E/M (P) Fy yard as `FREE for Laying only'.
Excavation in trenches in hard/ dense soil not exc 1.5 m wide and not exc 1.5 m in depth and getting out for laying cable, protection pipe etc all as specified and directed.
Returning, filling in (soils), including spreading levelling, watering and well ramming in layers not exc 25cm in soil complete all as specified and directed.
Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed.
M & L for dry natural river sand, free from particles as in cushioning for protection of cable punned down all as specified and directed. NOTE : Punned thickness shall only be considered for measurement and payment as specified.
Supplying and laying un-reinforced precast concrete cable cover (ISI marked),Class LV, Type I, flat, size 250 mm x 150mm x 40mm as in cable protection all as specified and directed
Supply & lay 40mm bore of tube steel water tubing light grade, galvanised with and including all fittings like tees, bends, unions, connector pieces etc with screwed socket joints & fixed as in cable protection laid in trenches/under roads/crossings/walls /poles etc all as specified and directed.
Supply & fix danger notice plate for LT of size 20cm x 15 cm x 1.60 mm thick, mild steel sheet, vitreous, enamelled white, with letters, figures and conventional skull & bones in single red colour and fixed with MS clamps, bolts of required size all as specified and directed.
Supply and top up of transformer oil conforming to IS superior quality low visocity having di-electric strength not less than 55 KV upto required level all as specified and directed..
Material and labour for HT 11 KV XLPE cable fault finding with the help of fault finding pin point location machine complete all as specified and as directed.
Material and labour for LT 1.1 V XLPE cable fault finding with the help of fault finding pin point location machine complete all as specified and as directed.
Material and labour for spray painting the outer surface of the transformer of capacity 500 KVA with one coat of synthetic enamel paint after preparation of surfaces and cleaning the bushes, name plate etc including writing MES / SM No with enamelled paint complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Aluminium conductor cable of size 25 to 50 sq mm complete all as specified and as directed.
Material and labour for cable jointing kit for 11 KV (earthed) grade cable for straight through jointing kit suitable for 11 KV (E) 50 sqmm to 95 sqmm 3core XLPE armoured aluminium conductor complete all as specified and as directed.
Supply and replacing sillica gel in breather of transformer 500 KVA complete all as specified and as directed.
Material and labour for Filteration of transformer oil of 500 KVA cap transformer with the help of filteration machine incl drain out complete low viscosity carbonised transformer oil and filteration upto the result all as specified and as directed. NOTE Dehyderation, de sludging ,filteration of transformer oil using stream line filter shall be carried out to achieve the desired dieclectric strength as directed. Oil samples are to be collected from top and bottom of oil tank and test results to be submitted for each sample before and after filtration.
Supply in repairs of MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16/18 KA with enclosure complete all as specified and as directed. Make : L&T (Cat No CM90517OOKO(DU-100D Series)) or equivalent approved in makes listed in ps
Supply and fix in repairs of MCB Single Pole, 240 V, fixed type, 6 to 32 Amps with breaking capacity 10 KA C Curve with short circuit indication complete all as specified and as directed. Make : L&T (Cat No AU10S10323 C) or equivalent approved in makes listed in ps
Supply and fix in repairs of MCB SPN, 240 V, fixed type, 6 to 32 Amps C Curve with breaking capacity 10 KA with short circuit indication complete all as specified and as directed. Make : L&T(Cat No AU10S20323C) or equivalent approved in makes listed in ps
Supply and fix in repairs of MCB TPN, 240 V, fixed type, 63 Amps with breaking capacity 10 KA with short circuit indication complete all as specified and as directed. Make : L&T(Cat No AU10S30633C ,C Curve) equivalent approved in makes listed in ps
Supply and fix CT single phase,CLASS 1.0, ratio 250/5 A burden 10VA Make :Newtek NE Series NE4B312 or equivalent approved in makes listed in ps
Supply only Capacitor duty contactor 5 KVAR . Make : Cat No.MOC5 1 NO of L&T or or equivalent approved in makes listed in ps
Supply only Cylindrical type Capacitor Gas filled of capacity 3 KVAR Make : Cat No LTCCN series of L&T or or equivalent approved in makes listed in ps
Supply only Cylindrical type Capacitor Gas filled of capacity 5 KVAR Make : Cat No. LTCCN series of L&T or equivalent approved in makes listed in ps
Supply only AMF relay for AMF Panel Make : SIMCONS or or equivalent approved in makes listed in pst
Supply only Closing coil for ACB 800 Amps Make : C & S or or equivalent approved in makes listed in ps
Supply only Tripping coil for ACB 800 Amps Make : C&S or or equivalent approved in makes listed in ps
Supply only Arcing contacts for ACB 800 Amps Make : C & S or equivalent approved in makes listed in ps
Supply only Fixed contacts for ACB 800 Amps Make : C&S or equivalent approved in makes listed in ps
Supply only Arc Chutes for ACB 800 Amps Make : C & S or equivalent approved in makes listed in ps
Supply only APFC Controller with 3 CT inputs ,Contactor switching, Automatic / manual type ,50 Hz , 5 VA, three phase 415 volts ,8 steps, flush mounting ,IP 20 degree protection Eta Ultra 8R type of size 144x144 mm Make : L&T (Cat No CS91050OOOO) or equivalent approved in makes listed in ps
Material & Labour for servicing of APFC Panel of cap 100 KVAR,LV 415 Volts, 3 phase 50 Hz by dismantling and replacing the old unsv pare parts such as capacitors , contactors and controller after lifting from original position to workable position and again fitting to original position after testing all as specified and directed. Note : Spares shall be measured and paid separately as Supply only.
Material & Labour for Servicing of GOD ( Gang operating device) Triple pole, mechanically operated mounted on insulator and steel frame with mechanism worked from ground level for current rating 200 amps of transformer 500 KVA after disconnecting by cleaning the male and female contacts to avoid arcing and making serviceable complete all as specified and directed. Note : Spares shall be measured and paid separately as Supply only.
Material and labour for cement concrete (1:3:6) type C2 (using 40 mm graded stone aggregates ) in foundations, filling and mass concrete including demolition of cement concrete all as specified and directed
Material and labour for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregates) in coping etc including weathering, slightly rounded or chamfered angles and throating and formwork including demolition of cement concrete all as specified and directed
Material and labour for precast cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregates) in cover slab and similar articles with plain faces for repair of earth pit at PTL including necessary moulds forms etc and demolition of existing precast covers all as specified and directed Note : Reinforcement shall be measured and paid seperately
Supply & fix mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & directed.
Supply only Digital Multi Function meter with Input voltage measurement range 50-520 VAC (P-P) ,128 samples / cycle Make : L&T Cat No WL441010OOOO or equivalent approved in makes listed in ps
Material & Labour for servicing of ACB 4 pole 415 volts, 3 phase 50 Hz of capacity 800 Amps completely by disconnecting the cable ,taking out and replace old unserviceable spare parts such as Shunt trip coil ,Arcing contacts,Fixed contacts and arc chutes .Testing and Connecting the cable after cleaning of each part and making serviceable complete all as specified and directed. Note : Spares shall be measured and paid separately as Supply only.
Material & Labour for servicing of indoor type floor mounted cubical type AMF panel with aluminium bus bar TPN 600 Amps 415 Volts, 3 phase 50 Hz completely after disconnecting and replacing the old unserviceable AMF relay,testing and refixing after cleaning of each part and making serviceable complete all as specified and directed. Note : Spares shall be measured and paid separately.
Supply and fix Copper strip 20x3 mm over protection insulator with saddles and fixing screws/GI nuts and bolts,washers etc. for roof conductors and down conductors above ground level including taking down of old copper strips complete all as specified and directed.
Supply and fix, Aluminium Strip 25x3 mm over protection insulator with saddles and fixing screws/GI nuts and bolts,washers etc. for roof conductors and down conductors above ground level including taking down of old aluminium strips complete all as specified and directed.
Supply and fix, GI strip 32x6 mm over protection insulator with saddles and fixing screws/GI nuts and bolts,washers etc. for roof conductors and down conductors above ground level including taking down of old GI strips complete all as specified and directed.
Material & Labour for providing bore earthing of bore dia 150mm, 6 m depth complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 6 m length, buried directly and preferably vertically to a depth not less than 6 m below normal ground level connected to earthing lead of 32x6mm dia galvanised iron strip by means of bolts, nuts, clamps, check nuts and washers complete upto and including test point all as per plate No 2 of SSR all as specified and indicated including earthing pit, salt, charcoal, PCC (1:2:4) type B-1 using 20mm graded stone aggregate RCC pit cover earth lead protection pipe GI medium grade 40mm bore including earth work in hard rock complete and testing on completion. Notes 1. The unit rate shall include for excavation and earth work/ bore in hard rock, PCC (1:2:4) type B1 for pit & RCC 1:2:4 type B-1 for cover with 8mm dia CTD Bar @ 150mm C/C both ways funnel with clamp, wire mesh complete 2. Earth strip upto 7.5m length shall be deemed to be included in the unit rate quoted by the tenderer.
Material & Labour for providing earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level connected with galvanized iron/steel earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers made out of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I and earth wire protected by galvanized pipe light grade 15mm bore and connected to DBs including necessary earthwork and excavation in any type of soil,RFR and removal of excavated balance spoil to a distance not exceeding 50m, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm dia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and directed by Engineer-in-Charge including testing on completion. NOTE : Rate quoted shall be deemed to include for 7.5m lead wire and protection pipe
Material & Labour for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level connected using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I and earth wire protected by galvanized pipe light grade 15mm bore and connected to TPN DB including necessary earthwork and excavation in any type of soil,,RFR and removal of excavated balance spoil to a distance not exceeding 50m, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm dia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and directed by Engineer-in-Charge including testing on completion. NOTE Earth strip and protection pipe 7.5m length shall be deemed to be included in the unit rate quoted by the tenderer.
Supply and fix in repairs security light fittings on Pole/Wall for use with LED lamps, 60 watts, 240 Volt,6000K, incl brackets of suitable size with high quality lenses & reflector, 240 Volt, High grade aluminium pressure Die-Cast Housing with toughened glass cover, IP-65 class of protection, Roadway luminaries incl taking down old Unsv bldg security light with high power led as a light source complete with control gear and accessories, provision of connecting wire with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. as phase,neutral and earth continuity conductor in and including PVC conduit pipe, accessories etc, and connecting to earth dolly connected up to bus bar box/switch complete. specified and directed. Make : HPL Cat No -HPLLEDSL6060S or equivalent approved in makes listed in ps
Supply & lay 80mm bore of tube steel water tubing light grade, galvanised with and including all fittings like tees, bends, unions, connector pieces etc with screwed socket joints & fixed as in cable protection laid in trenches/under roads/crossings/walls /poles etc all as specified and directed.
Material & Labour for cutting of road/hard standing for laying of pipe line and making good the disturbed portion in PCC (1:2:4) type B-1(using 20 mm graded stone aggregate) including removal of debris to distance not exceeding 50 m and depositing where directed complete all as specified and directed.
Supplying,installing,testing and commissioning cubical feeder pillar box of size 61x45x23cm suitable for 3 phase 4 wire 415 volts 50 Hz with outer shell made out of 3.15 mm thick CRCA steel sheet(powder coated) & mild steel angle(duly painted) of size 50x50x6 mm frame and legs(04 nos) grouted in PCC 1:2:4 type B2(using 40mm graded stone aggregates) in foundation (0.3x 0.3x 0.3m) with front openable with glands of suitable size to accomodate LT UG cables,single door system lockable/openable by keys having fancy locks with louvers completely vermin proof & including provision of aluminium bus bar of size 25x4mm (04 nos) IP 42 protection for outgoing of LT UG cable. NOTE Rate quoted is inclusive of aluminium bus bars(04 nos),MS angle(frame work), PCC works, painting, powder coating etc complete all as specified and directed.
Material and labour for painting to steel tubular poles 9 m long, any type with one coat of aluminium paint after preparation of old surface of the pole using necessary scaffolds or any other means including numbering of pole in enamelled paint complete all as specified and as directed.
Aziz Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .