| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹24.3 LAccepted-AOC B 259 RAJAJI PURAM LUCKNOW 226017 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226017 | L 1 | Accepted-AOC Being Lowest Bid and EAS accepted by IFA and TC | |
| 2 | L 2₹28.6 L+₹3.7 L (15.0%)Rejected-Finance 73 ASHOTOSH NAGAR NEAR KUNDAN GENERAL STORE OPP SARAD TIMBER P O MANAS NAGAR KRISHNA NAGAR LUCKNOW 226023 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226023 | L 2 | Rejected-Finance Other Than lowest | |
| 3 | L 3₹31.3 L+₹6.4 L (25.7%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | L 3 | Rejected-Finance Other Than lowest | |
| 4 | L 4₹31.5 L+₹6.6 L (26.6%)Rejected-Finance 58 SHAHEED NAGAR OPP BHIMRAO AMBEDEKAR UNIVERSITY RBL ROAD LUCKNOW 226025 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226025 | L 4 | Rejected-Finance Other Than lowest | |
| 5 | L 5₹32.5 L+₹7.6 L (30.6%)Rejected-Finance 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | L 5 | Rejected-Finance Other Than lowest |
Tender Value
₹44.3 L
EMD Value
₹88,640
Closing Date
1 Jul 2024, 6:00 pmClosed
GE (EAST) LUCKNOW
GE (EAST) LUCKNOW PIN 226002
SPL REPAIR TO ROOF TREATMENT OF BLDG NO P 44 AT AMC RECORDS AND SPL REPAIR REPLACEMENT OF ALUMINIUM WIRING TO COPPER WIRING AT BLDG NO P 50 UNDER GE (EAST) LUCKNOW
2024_MES_656730_1
GE/E/LKO/T-18 OF 2024-25
Open Tender
Civil Works
Item Rate
270 days
GE (EAST) LUCKNOW
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE (EAST) LUCKNOW
₹88,640
Yes
31 Aug 2024
3 Jun 2024
8 Jul 2024
3 Jun 2024
1 Jul 2024
17 Jun 2024
Amount
Taking down existing treatment any type/any thickness on roof including taking down/removing the backing bed concrete if any and dispose off at a distance exc 100m as directed etc complete all as specified and directed
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for brushing neat cement slurry with 3.0 Kg./Sqm over roof slab complete all as specified and directed
M&L for PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in roof padding/ roof kerbs / benching / coved fillets etc rounded or chamfered on edges.complete all as specified and directed
M&L for roof treatment with polymeric water proofing membreane with certain specification given below as under complete all as specified & directed (a) M&L plastering 10mm in CM 1:4 using 100% course sand on roof including WPC @ 3% by weight of cement. (Note : WPC will be measured and paid Separately). (b) Applying a coat of bitumenous primer @ 0.50 LTRs /Sqm and allow to dry (c) Applying a coat of hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm. (d) Supply and laying APP based polymeric water proofing membrane, weight not less than 3.00 kg/sqm and and minimum 3 mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) sealed the side laps with spread temper complete all as specified and directed. (e) applying a tack coat of hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm
M&L for 40mm thick brick tiles laid on 15mm thick screed bed in Cement mortar 1:6 and joints grouted flush in cement mortar (1:3) with WPC as per manufacture's instruction complete all as specified and directed.
Supply only liquid water proofing compound of approved quality and make confirming to IS complete all as specified and directed.
Taking down 100mm / 75mm dia AC rain water pipe (any size or pattern ) including all fitting, heads, shoes, bends and removing from sites complete all as specified and directed. (Measured over all as fixed along the centre line over the fittings and accessories)
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new PVC clamps complete all as specified and directed.
S&F 75mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new PVC clamps complete all as specified and directed.
S&F 110mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed.
S&F 75mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed.
Taking down old unserviceable 20mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed.
S&F 20mm GI water tubing, medium grade, galvanised with all fittings ( and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed.
Refixing old 20mm GI tubing galvanised with new fittings and fixed to walls, ceiling or laid in floors, trenches including necessary cleaning, cutting, screwing complete all as specified and directed.
M&L for disconnectiong existing tanks exc 250 Ltr & n. exc 500 Ltr Capacity , setting aside (or lowering if required ) for repairs, cleaning, etc and hoisting if required reconnectiong and re-fixing in same/other place position complete all as specified and directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per serial item No 18 here-in-before but one bell point controlled by one bell push, 06 Amp.
All as per serial item No 18 here-in-before but one, two way light point controlled by two, two way switches, 06 Amp.
All as per serial item No 18 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.
All as per serial item No 18 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.
All as per Serial Item No 18 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed
S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed
S&F Modular White cover plate with frame,12 module complete all as specified and as directed
S&F Modular White cover plate with frame,8 module complete all as specified and as directed
S&F Modular White cover plate with frame,3 module complete all as specified and as directed
S&F Modular White cover plate with frame,2 module complete all as specified and as directed
S&F Modular Metal flush box 12 module complete all as specified and as directed
S&F Modular Metal flush box 8 module complete all as specified and as directed
S&F Modular Metal flush box 3 module complete all as specified and as directed
S&F Modular Metal flush box 2 module complete all as specified and as directed
S&F Calling bell , AC, 230 Volts, single phase complete all as specified and as directed
S&F bell push , AC, 230 Volts, 2 module complete all as specified and as directed
Supply and fix fan step regulator, 120W 2 module complete all as specified and as directed
Supply and fix LED tube light fittings 1200 mm, 22 watt higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminum housing enviromental friendly, energy efficient complete all as specified and directed.
Supply and fix LED tube light fittings 600 mm, 10 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminum housing enviromental friendly, energy efficient complete all as specified and directed.
Supply & fix LED wall/surface mounted down lighter, 36 W, 2' x2 ' including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories. complete all as specified and directed
Supply & fix LED wall/surface mounted down lighter, 12 W including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified and directed
Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified and directed
Taking down carefully ceiling fan of any sweep complete with all accessories, dismantling blades and deposit in safe custody of AGE E/M Yard-II after rewiring fixed at same location before repairing and painting complete all as specified and directed
Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Supply and fix in replacement of industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 08 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volt of 06 to 32 Amp, "C" curve, 10 KA breaking capacity - 12 Nos.
Supply and fix in replacement of MCB, SP, AC, 240 volt of 06 to 40 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fix in replacement of MCB, DP, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr-in-Charge
S&F of exhaust fan single phase, 230/240 Volt heavy duty of size 300 mm sweep 1400 RPM including suitable louvers and making connection with twisted copper flexible wire 23/0.076mm complete all as specified and directed
S&F exhaust fans, plastic body, ac, single phase, 230/240 v of size 200 mm sweep with louver and making connection with twisted copper flexible wire 23/0.076mm complete all as specified and directed
Supply and fixing in replacement LED Bldg security light fitting LED 45 watt with SPD, PF not less or equal 0.9,epoxy coated cover sheet aluminium housing with heat resistant toughtened glass & IP 66 incl with bracket, clamps, nuts, bolts protection complete all as specified and directed.
Cutting walls any type, making holes for fixing of exhaust fan of any size or sweep and making good surface with fine plastering, finishing and colouring with existing colour matching complete all as specified and directed
Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50sqmm 4.0 core complete all as specified and directed.
Excavation in trenches soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes/cables etc getting out and bottom surface to required gradient complete all as directed & specified
M&L for Returning filling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed
M&L for Removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
Supply and laying &, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed. Note : Sand shall be measured only 18 CM punned down thickness.
M&L for Old size sub class 'B' bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable , adjacent/abutting each other complete all as specified and directed
Supply and fix on load Changeover Switch 160 Amp, 4P ,415 V, Open execution Type -1 complete all as specifiedd and as directed
suniltraders
QUALITY CONSTRUCTIONS CO
M/S S S A ASSOCIATES
M/S KAUSHIK CONSTRUCTION
M/S Reliance Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .