Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.3 LAccepted-Finance | 1 | Accepted-Finance L1 LOWEST BIDDER | |
| 2 | 2₹5.4 L+₹7,015.40 (1.32%)Rejected-Finance | 2 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 3 | 3₹6.3 L+₹97,074.63 (18.3%)Rejected-Finance | 3 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 4 | 4₹7.0 L+₹1.7 L (31.3%)Rejected-Finance | 4 | Rejected-Finance RATES ARE ON HIGHER SIDE |
Tender Value
₹7.4 L
EMD Value
₹8,000
Closing Date
25 Nov 2022, 5:00 pmClosed
SE ETC AZAMGARH
220KV S/S COLONY HAFIZPUR AZAMGARH
CONSTRUCTION OF 132 KV SOLAR BAY AT 132 KV S/S HALDHARPUR UNDER ETD, MAU.
2022_UPTCL_739830_2
41/AETC/2022-23
Open Tender
Electrical Works
Item Wise
60 days
MAU
UTR SLIP OF EMD TENDER FEE PAN CARD GST CERTIFICATE WORK EXPERIENCE etc.
2 documents required · 2 mandatory
₹944
SE ETC UPPCL AZAMGARH
₹8,000
2 Dec 2022
16 Nov 2022
26 Nov 2022
16 Nov 2022
25 Nov 2022
16 Nov 2022
16 Nov 2022 - 25 Nov 2022
Amount
Carriage of structure/materials from Electy. fabrication unit Naini Prayagraj/other Substations To 132 KV S/S Haldharpur. Sorting, counting, stacking mark wise and head loading of structure on truck/tralier (8.32 MT)
Safe carriage of loaded structure from electy. fabrication unit Naini Prayagraj To 132 KV S/S Haldharpur Mau. Distance approx. 260 km (8.32 MT X260 km=2163.2MT-KM)
Unloading of carriage structure from Truck/Trailer its Sorting, Counting and proper Stacking at the S/S premises as per direction of supervisioning engineer (8.32 MT)
Erection of following structure/equipments as per instruction of various equipments manuals and technical specifications including shifting of structures/equipments from store to erection site including all other associated works for completion of erection work satisfactorily:- Main structures (AKR-02Nos., BKR-01No., ABR-01No.,BBR-1No.)
Auxiliary structures (BBL-02 Nos, BTI-01 Set., BCT-06 Nos., ALP-05 Nos)
132 KV SF-6 Circuit Breaker
132 KV C.Ts
132 KV Bus Isolator without earth blades
132 KV Line Isolator with earth blades
120 KV Lightening Arresters
132 KV C.T./P.T. Junction box
145 KV Post Insulators
Gear box mechanism of 145 KV LSI & BSI
Main & check ABT Meters in ABT meter cubicle.
Extension of 132 KV Main Bus by Stringing of single Moose conductor bus including fixing of clamp, tension fitting & all other associated works. (3PhaseX 01Nos=03)
Jumpering of all equipments of 132 KV feeder bay with ACSR Panther conductor between Main bus including all droppers with help of suitable clamps/fittings to be provided by department including hoisting of 120 KN disc insulator on each phase on 132 KV gantry with suspension clamps and required cutting and bending of conductors.
Earthmat laying in extended switchyard for 132 KV Solar Bay. Fabrication of 3M long 40mm diameter electrode with following MS Rod having 150mm long conical shape and then its piercing vertically inside the ground with top 50mm below ground level and its welding with earth mat excluding the cost of MS Bar.
Extension of MS Round Bar Earth Mat 40mm by digging of earth cutting, laying, welding and back filling of earth and doing all other associated work to complete the job satisfactorily excluding cost of MS Round Bar.
Cutting, straightening & laying of following MS flat 700 mm below inside ground and above ground of 50 mm x 6 mm size and 25 mm x 6 mm size MS Flats for earthing of main auxiliary structures, equipment and cable trenches including welding with main earthmat and with the object to be earthed excavation of trenches its back filling painting and all other associated work to complete the earthing work satisfactorily as per technical specification. (MS Flat Provided by Contractor) Earthing of main structures with 75 mm x 10 mm size MS Flat.
Earthing of main structures with 50 mm x 6 mm size MS Flat.
Earthing of auxiliary structures and equipments with 25 mm x 6 mm size MS Flat.
Earthing of cable trenches/Racks with 25 mm x 6 mm size MS Flat.
Prepartion of Interconnection diagram of cable schedule as per drawings to complete job including C.B., C.T., Isolators etc. & submission of same in hard bound sets of 03 copies to the department.
Laying of following size of control cables in the cable trenches and relay panels in control room to various equipments, junction boxes, etc. in switchyard as per cable schedule its saddling with 25X3mm size including carriage of cable drums from stores to work site and shifting back to store with all other associated works to complete the job satisfactorily as per technical specifications:- Laying of 2X2.5 sqmm size control cable.
Laying of 4X2.5 sqmm size control cable
Laying of 6X2.5 sqmm size control cable
Supply & laying of following size of GI pipe B class for conduiting of control cable (metering) complete with elbow, Tee, socket reducer as per site requirement in the switchyard. 50 mm dia GI B class (medium) pipe for conduiting.
40/25 mm dia GI B class (medium) pipe for conduiting.
Shifting of 132 KV Distance Protection Panel from store of substation to the control room/kiosk room and fixing of panels by grouting new bolts etc. with all associated works i.e. earthing of panel alongwith all terminations with neat dressing of cables at control room end at new panels.
Shifting of 132 KV ABT Meter Cubicle from store of substation to the control room/kiosk room and fixing of panels by grouting new bolts etc. with all associated works i.e. earthing of panel alongwith with terminations of cables with neat dressing of cables at control room end at new panels.
Delta earthing of 120 KV LA consisting of 06 nos. electrode its placing inside the ground and connecting all three electrodes with M.S. flat and connecting the same with main earthmat at two place required excluding cost of MS strip and MS roud bar.
Lighting enhahcement in extended switchyard for 132 KV Solar Bay. Providing & fixing of new generation energy & environment friendly long aluminium outdoor beam street light with high power 120 watt LEDs as light source & exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 220 Volt AC input supply of CGL/Havells/ Surya/Philips/Bajaj etc. Including wiring from junction box to light fitting point and checking of healthyness of LED lights.
Supply and fixing of steel round pole (B Class) 9.0 mt long with 1.5 meter long bended at 1 meter at an angle of 300 for light in switchyard.in 1:4:8 cement concrete with 40 mm brick ballast in size of 450x450x1900 and plastering of 300 mm length of concrete above ground level.
Supply and installation of junction box of size 280x225x150 mm made of 16 SWG sheet with grey painting suitable for 2x4x6 C sq mm incoming cable and 2x4x6 C sq mm outgoing cable fitted with 03 Nos. HRC fuse link of 5 Amp. cable glands, nutral link, terminal block etc and fixing of junction box on columns with the help of 50x6 mm GI Clamp.
Supply and fixing of pipe bend of 50/35 mm dia GI 'B' Class pipe 1.5 meter long bended at 1 meter at an angle of 30o for light in switchyard.
Taking out 2C x2.5, 4Cx2.5 sq mm copper control cable from junction box light fittings fixed over the column by fixing G.I. clamps of 40x5mm flat with each crossed bracing on structures.
Providing & Fixing of outdoor type AC power supply cubical of 16 SWG MS sheet Vermin proof having 03 Nos. Alu. Bas Bar for RY B-Phase and 01 No. netural bas bar of size 25x12 mm and 25x6 mm respectively. The cubical will have 16 Nos. 32 Amp. 3 Phase MCB And 08 Nos. 06 Amp. Singal Phase MCB of Havell's make with indication Lamp wiring detail as per tech. specification.
Termination of ACDB by L.T. power cable of size 95/50 sq. mm includes laying and termination of cable with crimping of lugs etc.
Laying of L.T. power cable of size 95/50 sq. mm for ACDB from control room to designated point for ACDB.
Providing & Fixing of Name Plate made of 2mm Thick Alu. sheet with covering of 3M HIP/ Equivalent retro reflective sheet of size 300mmx150mm plate to fixed with the help of Nut & Bolts already installed equipement (C.B.-01No., BSI-01 No., LSI-01No., DPP Panel-01No., Metering Panel-01No., Shutdown Board-01No.) (content to be printed on Name Plate will be provided by department)
Providing & Fixing of Phase Plates made of 2mm Thick Alu. sheet with covering of 3M HIP/ Equivalent retro reflective sheet of size 300mmx150mm plate to fixed with the help of Nut & Bolts already installed equipement (C.T. - 03 Nos., P.T.-03 Nos., L.A.-03 Nos(content to be printed on Phase Plate will be provided by department)
Painting of all sizes of M.S. flat/strips above ground with one coat of red oxide primer and two coat of synthetic enameled green Japan paint after thorough rubbing and cleaning of strips including the cost of paint.
PART-B(SUPPLY) PG clamp (as per sample) Moose To Moose
Moose To Panther
Panther To Panther
Five Bolted Single tension fitting suitable for Moose type conductor (as per sample)
Complete set of Single Suspension fitting suitable for Panther type conductor (as per sample)
Supply of folloowing fire extinguisher carbon dioxide as per IS speen, No. 2878/1986 and as per technical specifiction 11/9 Kg
Supply of dry chemical poweder type fire extinguisher of 4.5 Kg Capacity conforming with IS 2171/1985 and as per tetchnical specifrication
TARUN ENGINEERING WORKS
M/s. ADITYA TRADING CO., KM-383, RAIDOPUR OFFICERS COLONY, AZAMGARH, U.P.-276001.
M/S Shree Constraction
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .