Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹34.0 L+₹45,536.72 (1.36%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹35.4 L+₹1.8 L (5.44%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹35.8 L+₹2.3 L (6.71%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹39.3 L+₹5.8 L (17.2%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
Tender Value
₹43.9 L
EMD Value
₹88,000
Closing Date
27 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI PRAVEEN KUMAR, IDSE
GE KHADAKWASLA, NDA KHADAKWASLA, PUNE-23
ADDN AND ALTERATION AND RENOVATION OF TOILET BATHROOMS AND VERANDAH OF BLDG NO P-110 (BK NO 02) AT NDA KHADAKWASLA
2023_MES_615989_1
8748/E8
Open Tender
Civil Works
Item Rate
180 days
GE KHADAKWASLA
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE KHADAKWASLA
₹88,000
Yes
24 Nov 2023
28 Aug 2023
2 Oct 2023
28 Aug 2023
27 Sept 2023
13 Sept 2023
28 Aug 2023 - 12 Sept 2023
Amount
Dismantling floor or wall tiling of any description and size including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc including cleaning off premises where complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints,hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including cleaning off premises where complete all as specified and directed.
Demolition of brick / block masonry / Stone masonry built in Cement mortar complete all as specified and directed.
Taking down chowkhats or frame not exc 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frame not exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frames) complete all as specified and directed.
M&L precast cement concrete 1:3:6 type C-1 (using 20mm graded aggregate ) block masonry with solid blocks exc10 cm thick in width and setting in cement mortar 1:6 complete in wall complete all as specified and directed.
Material and Labour for Joint free non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 Sqm but n exc 0.18 Sqm, (400x400x7 to mm thick), in flooring etc set and jointed in neat cement slurry laid over & including 15 mm thick screed bed cement mortar (1:4) and pointed with coloured cement to match with surfaces of tile complete all as specified and directed.
M&L for coloured Glazed ceramic tiles as in vertical surface of Size 350x 250 x7mm /450x350x7 mm set and jointed in neat cement slurry laid over 10 mm thick cement rendering in cement mortar 1:4. and pointed in white or colour cement to match the tile complete all as specified and directed.
M&L for 25 mm thick cement concrete type B-1, 1:2:4 (20 mm size graded stone aggregate) as in sub base of tiles complete all as specified and directed.
M&L 20 (+ -2mm) thick Granite (of jet black ) work (table rubbed and polished ) in steps ,jambs ,pillars,window cills, cooking plateforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. Exposed edges to make half round.
M & L machine cut superior quality Kota stone slab flooring 20-25 mm thick over cement screed , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete match including bulnosed to edges complete and incl 20 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
Taking down 15 mm bore mild steel tubing of medium grade and connections incl cleaning for refixing or removal from site complete all as specified and directed.
Ditto all as per item No 14 above but for 20 mm bore
S&F 15 mm bore mild steel water tubing medium grade galvanized with all fittings and fixture fixed to walls ceiling or laid in floors complete all as specified and directed.
Ditto all as per item No 16 above but for 20 mm bore
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth etc complete all as specified and directed.
Dismantling of existing water tanks of capacity exc 500 lit not exc 1000 lit and removing to store complete all as specified and directed.
S&F Rotational moulded polye- thylene water storage tanks ISI Mark (Triple layered) 1000 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
M&L for 15 mm thick cement plaster on brick or concrete surface in cement mortar 1:6 included finishing surface even and smooth without using extra cement on walls etc complete all as specified and directed
M&L for 10mm thick cement plaster on concrete surface in cement mortar 1:3 included finishing surface even and smooth without using extra cement on ceiling etc complete all as specified and directed
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over one coat of alkali registant priming paint using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.
All as per item No 23 above here-in-before but in ceiling etc complete all as specified and directed.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supply and fixing in opening as per the specification and drawing and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with hit moulded plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the tiles and rail with suitable PVC sheet bedding and joined together with solvent cement, supplying and fixing in the frame at site as per specificaton & drawing and as directed.
S&F anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Supply and fixing Powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodisedaluminium snap beading, screws etc.including fixing of 5 mm thick Sheet glass, complete all as specified. Fixing included the making good of the opening, such as plastering jambs, levelling and finishing complete all as specified and directed.
S&F 100mm Aluminium handles, cast type, anodised complete all as specified and directed.
S&F 75mm butt hinges cold rolled mild steel medium weight and fixed complete all as specified and directed.
S&F Aluminium anodised barrel tower bolts of extruded section 100mm long, complete all as specified and directed.
S&F in repairs Bib taps 15mm dia, chromium plated ,fancy type ,cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed including taking down old one complete all as specified and directed.
S&F in repairs Stop valves 15mm dia, chromium plated ,fancy type, cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed including dismantling of old one complete all as specified and directed.
S&F in repairs for PVC flushing cistern valve less, syphonic action type low level, ball valve, float and handle with bracket fixed in repair of 10 ltrs capacity complete all as specified and directed
S & F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair Water closet (Squatt pattern) vitreous China squatting pan, ‘Orissa’ pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) connection to trap and squatting pan including P' trap set in and including concrete etc.making good to floor complete all as specified and direted
S&F in repair towel rail 600 mm long of CP brass, fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed.
S&F in repair Soap dish any type fixed to plugs with chromium plated brass screws minimum size 160x160x90mm complete all as specified and directed.
S&F in repair Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe complete all as specified and directed.. Note: Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe
Demolition of lime / lean concrete in sunken floors etc of any description complete all as specified and directed.
M&L, 25 mm thick PCC 1:2:4 using 20 mm graded stone aggregate over 250 thick PCC 1:4:8 with 40mm graded stone aggregate as in filling of sunken floors over a layer of APP based modified pre fabricated five layer 3 mm thick and weighing not less than 3.6 Kg/Sqm water proofing membrane over a layer of bitumen cutback (85/25) grade applied hot (1.5 Kg/sqm) over 10mm thick plaster in cm 1:3 with WPC @ 3% by wt. of cement complete all as specified & directed (Only plan area of sunken portion is measured)
Dismantling of cast iron pipe 75/100 mm dia joint in cement mortars and taking out of trench or in any position complele all as directed.
S&F 75mm bore cast iron soil waste and vent pipe in any length with or without ears fixed to walls including suitable clamps after every one mtr of interval with cement joints fixed to wall complete all as specified and directed.
S&F 100mm bore cast iron soil, waste and vent pipe in any length with or without ears fixed to walls including suitable clamps after every one mtr of interval with cement joints fixed to wall complete all as specified and directed.
S&F 75mm bore Cast iron soil, waste and vent pipe in any length with or without ears, with cement joints, laid in treanches or in floors complete all as specified and directed.
S&F in repairs CI Bends (any radius), diminishing pieces or tapers of 75 mm dia fitted with oval access door complete all as specified and directed.
S&F in repairs Cast iron floor trap with CP grating including jointing to waste pipe with run lead, dia of outlet 100mm set in cement concrete type B1 (1:2:4) complete all as specified and directed.
S&F in repairs for cast iron cowls 100 mm size complete all as specified and directed.
Supply only integral water proofing compound ISI marked complete all as specified and directed.
S&F in repair of branch pieces, single(equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 100 mm dia complete all as specified and directed.
S&F in repair of branch pieces, single(equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 75 mm dia complete all as specified and directed.
M&L for Extra over cast iron pipes and fittings if lead joint is provided in lieu of cement joint for 100mm dia pipe complete all as specified and directed.
M&L Extra over cast iron pipes and fittings if lead joint is provided in lieu of cement joint for 75 mm dia complete all as specified and directed.
S&F cast iron work grade FG 150, unmachined as in covers for gully trap of size 300x300mm and thickness n exc 6mm( weight of each cover exc 5 kg) as approved complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light/fan/socket) including all accessories wire, casing caping/conduit, screws etc and making good the disturbed surfaces complete all as specified and directed.
M&L for concealed point wiring in and including new PVC conduit medium grade with the help of multi-stranded unsheathed FRLSH copper cable 1.5 sqmm 650/1100V conforming IS:3419 -1988 adhereing to colour code including earth wire of the size 1.5 Sqmm green colored with modular steel or cast iron terminal boxes and modular cover plates as required at site including making good the distrubed surfaces and matching it with existing surface for the following :- (a) One light /fan point controlled by one switch one way
(b) Ditto all as per item no 57 above but One 3 pin 5 Amps socket outlet point on independent board
( c) Ditto all as per item no 57 above but One 3 pin 5 Amps socket outlet point on Same board
M&L concealed point wiring with 4 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable in and including PVC conduit not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLS cable size 4 sqmm copper conductor as earth wire to common earth dolly complete all as specified and directed.
S&F modular switch 1 way 10 A 1 module complete all as specified and directed..
S&F Modular socket 6 A 2/3 Pin 2 module complete all as specified and directed..
S&F Modular switch 1 way 16 A 1 module complete all as specified and directed..
S&F Modular socket 6 A/16A 2/3 Pin 2 module complete all as specified and directed..
S&F in replacement for ceiling rose, 3 terminals /PVC/Polycarbonate, isolated body complete all as specified and directed.
S&F in replacement of 18/20watt,230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose complete all as specified and directed. Make- Luker LT5M20 / Havells ENDURALINEARNEOBS20WLED865SPCWH / Bajaj BCLAB 20W WH LED P or equivalent in makes as mentioned at makes list in PS
S&F in replacement of 1x10 watt,230V surface and wall mounted LED batten suitable for mirror light with polycarbonate housing and integrated electronic electronic driver including connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed. Make: Luker cat part no.LT510P or equivalent in makes as mentioned at makes list in PS
S&F in replacement LED building security light fiitting 30 W, IP-65 protection made up of die cast alluminium housing with high power LED as lighting source and lens embeded PC cover having TOP opening seperate driver compartment complete all as specified and directed Make- Luker LSTE-30/ Havells ENDURACITYLITEPLAT PLUSSL30WLED757SASYBOPC / Wipro LR02-331-XXX-57-XX or equivalent in makes as mentioned at makes list in PS
S&F Infrared Presence Surface Mount Sensor for light fittings including connecting up with twin core twisted flexible copper cable to switch and fitting complete all as specified and directed.
Taking down the exhaust fan carefully and cleaning/Servicing the fan if any repairs/ replacing of parts required complete including painting the fan with enamel spray paint white colored and fixing back the fan with fixing accessoires required at site complete all as specified and directed.
S&F of Plastic ventilation fan with BLDC motor, energy efficient of 200/250/300 mm sweep inclduing replacing the plywood as per the site requirement. Make: Atomberg/ Crompton Greaves Trans Air/ Havells.
Disconnecting and taking down existing userviceable geyser of any capacity, taking it to workshop for repairing. Opening the geyser and dismanting all parts and taking out inner tank/container, removing dents making to shape including welding / brazing the leakage portion, filling the portion between inner tank and out casing of geyser with new glass wool heat insulating material Reassembling and painting the outer casing of geyser with two coats of superior quality synthetic enameled spray paint and re- fixing to original place complete all as specified and directed.
M&L for Cutting chases for concealed conduit wiring, pinning in and making good to surface where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., cutting not exc 10 cm girth including 3 mm thick wall care putty on wall, making surface matching to adjacent surface complete all as specified and directed.
Taking down carefully sub main wiring of any type and size and making good disturbed surfaces complete all as specified and directed.
M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 4 Sqmm, 1100 Volts grade in and including PVC conduit medium grade not less than 25 mm complete with conduit accessories such as bends, tees etc. and copper cable 4 sqmm continuous earth wire complete all as specified and directed. Note: Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with PVC conduit shall be measured as one RM
M & L for Sub Main wiring with PVC insulated FRLSH grade cable LT 1100 Volts grade, 2 x 6 Sqmm with one continuous earth wire of 6 Sqmm, PVC insulated unsheathed, multistranded with stranded copper conductor drawn through and including concealed in any type of wall, roof, etc, with all connected fittings including pressed steel terminal boxes suitable all standard accessories and make good to match with the existing surfaces after completion alongwith one continuous earthwire and connected to the common earth complete all as specified and directed. Note :- 2 runs of 6 Sqmm and One run of 6 Sqmm earth wire and including including suitable size of PVC pipe, elbow, bends etc will be measured as One Running Meter
M & L for Sub Main wiring with PVC insulated FRLSH grade cable LT 1100 Volts grade,4 x 6 Sqmm with one continuous earth wire of 2 x6 Sqmm, PVC insulated unsheathed, multistranded with stranded copper conductor drawn through and including concealed in any type of wall, roof, etc, with all connected fittings including pressed steel terminal boxes suitable all standard accessories and make good to match with the existing surfaces after completion alongwith one continuous earthwire and connected to the common earth complete all as specified and directed. Note :- 4 runs of 6 Sqmm and One run of 2 x6 Sqmm earth wire and including including suitable size of PVC pipe, elbow, bends etc will be measured as One Running Meter
S&F in repairs sheet metal enclosures single pole MCB 20 Amps with a two pin and earth plug and socket complete with all accessaries etc complete all as specified and directed.
S&F in replacement of Factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified Note:MCBs/ MCCBs will be measured and paid seperately under respective Sch A item in the schedule
S&F MCCB with rating of 100 Amps, 415 Volts 3 pole with 16 kA breaking capacity, thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu). MCCB should be with suitable spreaders and phase barriers for each terminals complete all as specified and directed.
S&F in replacement MCB DB 12 way SPN Double door sheet metal enclosure factory made suitable for MCB DB's 240 volts,concealed in wall complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed . Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced.
S&F MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and directed.
Supply and fix in replacement of C Curve MCB DP 40-63 Amps working on 240 volts, 50 HZ,10 KA complete all as specified and directed.
Supply and fixing 415V 10KA 'C' curve miniaturecircuit breaker (MCB) TP 63 AMP of following poles andcurrent carrying capacity in the DB complete withconnection testing and commissioning complete all as specified and directed.
Supply and installing 100mm width x 50mm depth x 3mm thickness size of perforated hot dipped Galvanised Iron cable tray (Galvanisation thickness not leass than 50 microns) with perforation not more than 17.5% inconenient sections, jointed with connectors, suspended from the ceiling with GI suspenders including GI Bolts & nuts as required complete all as specified and directed. Note : 1. All necessary fixing/ connecting arrangements of nut, bolt, MS rod, to be provided by the contractor without any extra payment from department. 2. Quoted rate is to be deemed the charges of necessary boom lift.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc complete all as specified and directed.
Mourya Enterprises
Mehta and Co.
ELIEYAS TRADERS
Prem Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .