| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹23.7 L+₹58,041 (2.51%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹24.4 L+₹1.3 L (5.83%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹27.1 L+₹4.0 L (17.4%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹35.9 L+₹12.8 L (55.6%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
12 Feb 2024, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
REPAIR/REPLACEMENT OF UNSERVICEABLE SPARES OF COOLING TOWERS, AHUS, PUMPS AND REWINDING OF ITS MOTORS AND REPAIRING OF NORMAL OUTDOOR UNIT WITH VRF BASED OUTDOOR SYSTEM AND CONNECTED MISC E/M WORK AT BASE HOSPITAL UNDER GE (EAST) DELHI CANTT-10
2024_MES_636530_2
GE/DE-94/2023-24
Open Tender
Civil Works
Item Rate
120 days
GE (EAST) DELHI CANTT-10
Class D Cat c (i)
8 documents required · 8 mandatory
₹500
GE (EAST) DELHI CANTT-10
₹94,000
Yes
26 Feb 2024
24 Jan 2024
14 Feb 2024
24 Jan 2024
12 Feb 2024
25 Jan 2024
Amount
Taking out the filter from AHU up to 1000 CFM to 13000 CFM cleanning coil with suitable chemical and jet of water pressure with pump and remove all the scale and foreign material deposited in side the coil followed with air pressure to sweep up all the particles and ensure thorough flow of air over the cooling coil complete all as specified and directed for any capacity of AHU and refixing the air filter after cleaning.
M&L for repairing/ servicing AHU Fan Motor of following capacity, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of size & discription to match with existing including insulating materials, varnishing, drying, replacement of both driven end & non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed:-
5 HP/ 5.5 HP AHU fan motor, Make-Kirloskar, Cromton Greaves, Model-1622 TOP
7.5 HP AHU fan motor, Make- Kirloskar, Bharat Bijlee, ABB, Model-KI 1325 & M2BA 132S4
10 HP AHU fan motor, Make- ABB, Model-M2BA 132M-4, SMC-4 & HX-132SM64
Taking up or down 40 mm bore MS pipe from trenched/ wall surfaces or in any position complete all as specified and as directed.
All as per item No 3.00 here-in-before but of pipe 50 mm bore.
All as per item No 3.00 here-in-before but of pipe 65 mm bore.
All as per item No 3.00 here-in-before but of pipe 80 mm bore.
All as per item No 3.00 here-in-before but of pipe 100 mm bore.
All as per item No 3.00 here-in-before but of pipe 125 mm bore.
All as per item No 3.00 here-in-before but of pipe 150 mm bore.
Supply and lay MS pipe condenser water or cooling tower piping of MS 'C' class 40 mm dia confirming to IS-1239 and IS- 3589 both revised till date as required and as specified and complete with bends, reducers tees, supports vibration pipe supports,structures shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and complete all as specified & directed.
All as per item No 10 here-in-before but of pipe 50 mm bore.
All as per item No 10 here-in-before but of pipe 65 mm bore.
All as per item No 10 here-in-before but of pipe 80 mm bore.
All as per item No 10 here-in-before but of pipe 100 mm bore.
All as per item No 10 here-in-before but of pipe 125 mm dia.
All as per item No 10 here-in-before but of pipe 150 mm bore.
M&L for taking out Cooling Tower Motor of following capacity, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of size & discription to match with existing including insulating materials, varnishing, drying, replacement of both driven end & non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed:-
2 HP Cooling Tower Motor
3 HP Cooling Tower Motor
5 HP Cooling Tower Motor
7.5 HP Cooling Tower Motor
Supply only, in replacement heating element capacity 3 KW, ISI marked and making electric connections and taking down old unserviceable heating elements, complete all as directed. Make : Daspass/ Theata
S&F in repair 50mm thick box type Pre-Filter (EU-4) Synthetic media type flange type (non woven type ) efficency - 90% down to 10 micron with complete all fitting for AHU and 50 mm wg static pressure with rod support fabrication with GI/Aluminium frame, suitable for AHU of make fedders lloyd all complete as specified & directed. Make for filter :- Athlete/ AAF/ Fredenberg
S&F in replacement Absolute HEPA filter of size 830 x 550 x 690mm having rated flow 2000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed. Make - Thermadyne / Spectrum / Puromatic / Athlete
S&F in replacement Absolute HEPA filter of size 610x610x305mm having rated flow 2000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed. Make - Thermadyne / Spectrum / Puromatic / Athlete
S&F in replacement Absolute HEPA filter of size 610x305x305mm having rated flow 1000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed. Make - Thermadyne / Spectrum / Puromatic / Athlete
Excavation in trenches not exc 1.50 mtr wide or 10 sqm on plan, 1.50 mtr for manholes & sewage lines, drain, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and directed.
M&L for removing excavated soil to a distance exc 500 mtr and not exc 1.0 km and depositing where directed complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6M mean redius built in cement mortar 1.6 including demolition of old brick complete all as specified and directed.
M&L rendering 15mm thick in cement mortar 1.4 on other than fair faces of brick surfaces of walls finished the surface fair and even without using extra cement complete all as specified and directed.
Supply & charge the refrigerent R - 407 Gas complete all as specified and directed. (Make:- Mafron/ Freon/ Floron)
Supply & charge the refrigerent R - 410 Gas complete all as specified and directed. (Make:- Mafron/ Freon/ Floron)
Cleaning of inside surface of supply Ducts of HVAC system by (NADCA sertified duct cleaning agency) using high power vacum air compressor, Robotic camera, air hammer, special nozzles, air sweep with other required accessories giving/ showing inspection of duct before and after cleaning of duct using color video inspection
Supply, Installation, testing and balancing of volume control dampers powder coated extruded aluminium construction Gravity based complete all as specified and as directed.
Supply and fixing fire proof double layered canvas cloth connection for AHU outlet including inspection opening complete with flanges made out of 22 GSS Sheet on both side for connection to AHE and duct complete with nuts, bolts complete all as specified and directed.
M&L for insulation of 40mm bore MS pipe with PUF slab 30 mm thick with applying bitumainous compound and GI cladding with 26 guage GI sheet etc cmplete including taking down existing PUF insulation all as specified and directed.
All as per item No 33 here-in-before but of pipe 50 mm bore.
All as per item No 33 here-in-before but of pipe 65 mm bore.
M&L for insulation of 80mm bore MS pipe with PUF slab 40 mm thick with applying bitumainous compound and GI cladding with 26 guage GI sheet etc cmplete including taking down existing PUF insulation all as specified and directed.
S&F in repair 3 pole power contactor 415 V, type MNX 70 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed. Make- SIEMENS/ L&T/ BHARATIA CUTTLER HAMMER
S&F in repair 3 pole power contactor 415 V, type MNX 50 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed. Make- SIEMENS/ L&T/ BHARATIA CUTTLER HAMMER
S&F in repair 3 pole power contactor 415 V, type MNX 25 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed. Make- SIEMENS/ L&T/ BHARATIA CUTTLER HAMMER
Supply only in replacement of thermal over load relay range 20-33 Amps, with built in single phase preventer, direct/ separate mounting on contactors, as required, with and incl taking down of unserviceable relay and making all electric connection, complete all as directed. Make : L&T/ Schneider Elect/ Siemens/ C&S/ Legrand
All as per Srl item No 40 here-in-above but 14-23 Amps capacity.
All as per Srl item No 40 here-in-above but 9-15 Amps capacity.
All as per Srl item No 40 here-in-above but 1.4 - 2.3 Amps capacity.
M & L for Panting of complete water cooled central AC plant and DX type AC plant, compressor, GI pipe lines, valve, pump sets, cooling tower, AHU pipe lines and chiller pipes etc complete all as specified and directed.
2 x 15 TR AC plant
3 x 30 TR AC plant
3 x 40 TR AC plant
S&F in replacement, of MCCB 100 Amp, 3 pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed. Make- Siemens/ L&T/ Schneider Elect/ C&S
S&F in replacement, of MCCB 200 Amp, 3 pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed. Make- Siemens/ L&T/ Schneider Elect/ C&S
S&F in replacement, of MCCB 400 Amp, 3 pole thermal magnetic relese based with breaking capacity 50 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed. Make- Siemens/ L&T/ Schneider Elect/ C&S
S&F in replacement, of MCB 63 Amp, - pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed. Make- Siemens/ L&T/ Schneider Elect/ C&S
S&F in repalcement of complete GI frame for AHU 8500 CFM and Outer Skin 0.6 mm Pre-Coated GI, Inner Skin - 0.6 mm Plain GI, Frame work- Hollow Extruded AL Profile, Thicknes of insulated Panels- 25 mm thick, CFC Free PUF injected (Density: 40 Kg/Cum), Material of Drain pan :- 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation. Unit Base:- G.S.S Base Channel. complete all as specified and directed.
S&F in replacement of CHW COIL:- Coil casing/Blank offs- GI, Material of Tube - Copper, Tube diameter(mm/inch) - 12.7mm/1/2" O.D, Thickness of tube (SWG/mm) - 27 SWG/0.41 mm, Header Material of fins - 0.15 mm plain Aluminum, No of Fins per inch (FIP)- 11/12 complete all as specified and directed.
S&F in replecement of FILTERS:- Synthetic (non woven type), efficiency of pre-filters (EU-4)- 90% down to 10 micron suitable for 8500 CFM complete all as specified and directed.
S&F in replacement of DIDU centrifugal forward curved Fan, Drive set with v-belt & Motor (IE-2) Capacity 5 HP Suitable for 8500 CFM Complete all as specified and directed.Make:- ABB/BHARAT BIJLEE/CROMPTON .
S&F in replacement of complete expansion valve suitable for 40 TR Complete all as specified and directed.
S&F in replacement of complete expansion valve suitable for 30 TR Complete all as specified and directed.
S&F in replacement of Butterfly Valve made out of Cast Iron, dia150mm complete with all accessories with thermal insulation
All as per item No 55 here-in-before but of pipe 125 mm bore.
All as per item No 55 here-in-before but of pipe 100 mm bore.
All as per item No 55 here-in-before but of pipe 65 mm bore.
All as per item No 55 here-in-before but of pipe 50 mm bore.
All as per item No 55 here-in-before but of pipe 40 mm bore.
S&F in replacement of Y-Strainers made out of Cast Iron, dia 65mm complete with all accessories
All as per item No 61 here-in-before but of pipe 50 mm bore.
All as per item No 61 here-in-before but of pipe 40 mm bore.
All as per item No 61 here-in-before but of pipe 32 mm bore.
All as per item No 61 here-in-before but of pipe 25 mm bore.
S&F in replacement of 3 way modulating valves dia 65 mm for AHU complete with linkage modulating actuatator with all accessories complete in all respect as specified
All as per item No 66 here-in-before but of pipe 50 mm bore.
All as per item No 66 here-in-before but of pipe 40 mm bore.
All as per item No 66 here-in-before but of pipe 32 mm bore.
S&F Air vent valves made out brass. 25mm dia Complete in all as specified and directed.
S&F in replacment Pot stainer 150mm dia Complete in all specified and directed.
Supply, installation, testing and commissioning in replacement , Ultra Sonic (Mist) Humidifier Model- RM-3 Capacity- 3 LPH, Type :- Horizontal (Indoor Unit), Construction:- Tank made from 1.5mm thick stainless sheet 304L grade sheet, Electrical panel constructed in 18 Gauge CRC Sheet, Controls:- (a) Low Level Cut-out- Mini Float Switch (b) Auto Drain System - Timer with Motorized valve for auto flushing (c) Filter Assembly - 5-10 micron air filter and 5-10 micron water filter. Mist Outlet fan with throw type blade Electrical panel:- Power Supply (S.M.P.S), Contactor, MCB Relay card, connectors, On/off switch with Light, Auto Drain System, Indication for Drain valve / Humidity off/ Supply On/ Low Level. Paint:- Tank - Phiroza blue enamel paint complete all as specified and as directed.
YASHVI ENGINEERS
Vishal Traders
Saini Enterprises
Iconic Engineers
M P TYAGI ENGINEERS AND CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .