Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-Finance | L1 | Accepted-Finance Ist Lowest bidder | |
| 2 | L2₹6.5 L+₹9,108.50 (1.41%)Accepted-Finance | L2 | Accepted-Finance IInd Lowest bidder |
Tender Value
₹6.2 L
EMD Value
₹8,200
Closing Date
13 May 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
EDC I Saharanpur
Business Plan work in the area of EDSD Behat under EDD Behat
2024_PVVNL_921864_2
375/W/EDC-I/SRE/2023-24
Open Tender
Electrical Works
Lump-sum
45 days
Saharanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE EDC I SRE
₹8,200
15 May 2024
2 May 2024
13 May 2024
2 May 2024
13 May 2024
2 May 2024
Amount
Detail of Work
Safely Carriage of 100 KVA T/F from ESC, SRE to Site of work including loading & unloading at both ends.
Safely carrage of STP/PCC Pole 11/8.5 Mtr Long from ESC SRE to site of work including loading and unloading at both ends.
Safely carriage of Line Material (Except PCC Pole/Weasel conductor)ESC SRE to site of works through privet vehicle including loading and unloading at both ends. (Distance 0 to 25 K.M.)
Erection of single support on ST/PCCpoles up to 11/8.5 Mtr Long with complete fitting of all accessories of 11 KV/LT Line as per RESPO specification
Fabrication and Erection of D/P on ST/PCC poles 11/8.5 Mtr. Long with complete fitting including concreting in block of 450x450x1500mm. in ratio 1:4:8 with cement, sand and brick ballast size 1”x1.5” as per RESPO specification.
Safe installation of 100 KVA T/F on the D/P with complete fittings including making connections and commissioning.
Safely carriage of ACSR weasel conductor from ESC SRE to site of work including loading and unloading at both ends.
Grouting of stay rods by digging of pits in block 600x600x300 MM & cement concreting in ratio 1:4:8 with cement, sand and brick ballast and nozzling of stay wire 7/10 SWG and fitting the same on the pole including fixing of stay insulator in stay wire.
Laying, lifting, stringing, sagging jump ring & binding of ACSR weasel conductor for HT/LT Line.
Removal of 100 KVA T/F from the existing D/P after opening HT & LT connection and with shifting the T/F from the site to ESC, SRE/JE store with loading & unloading at both ends.
Safe cartage of 250 KVA T/F from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 25 km.)
Constriction of plinth for installation of 250 kv T/F of size 1.5x1.5x1.5 mtr made of 9”inch thick wall in all four sides with 6”inch thick RCC top duly filled with sand and plastered 12mm thick in ratio 1:4 with cement and sand on outer surface of brick wall.
Safe installation of 250 KVA T/F on the Plinth with complete fittings including making connections and commissioning.
Wire mesh fencing of 250 KVA T/F size 2.5x2.5x2.5 mt. grouting making frame of MS angle 45x45x6 mm and fixing four no. MS strip size 25x6 mm at equal distance in between the frame and fixing squre mesh 50 mm square in each frame the fencing should cover all side of T/F with providing 1 No. door size 6'x3' with sitakni & Dandala.
Pipe/Water Level Earthing of 250 KVA T/F (1 No body & 1 No. neutral earthing) by boring of 60 Ft deep & fixing of 60 ft. G.I pipe 11/2" Dia (Jindal Class B) and connecting with G.I. Strip of size 40x5 mm and G.I wire at bottom of G.I pipe to the T/F providing of required charcoal & salt in the pipe
Safely revomal and carriage of old and damaged 11 KV I/C/OG VCB from ESC SRE to site of work including loading and unloading at both ends.
Safely carriage of 11 KV I/C/OG VCB from ESC SRE to site of work including loading and unloading at both ends.
Safely Installation of 11 KV I/C/OG VCB and connection properly
Laying Control Cable size 4x2.5
Providing of J/I-Hook
Providing of Suspenstion clamp
Providing of PRC connector
Fixing of distribution Box
Providing of Dead & Clamp
Providing of Lug
Providing of all type clamp with nut & bolt .
Earthing of pole by Earthing rod.
Complete Repairing of tripping mechanism system & replacement of lever, bush, sping etc of 33KV VCB
Providing and fixing of damage triping coil complete
Providing and fixing of charging gerari & non retun bearing
Providing and fixing of Epoxy spout complete with copper contact suitable for VCB
Providing and fixing of guccha patti & 03 No. Brass bush etc suitable for VCB
Complete Repairing of jack and replacement of lever,bush, bearing and jack rod complete suitable for VCB
Providing of 2.5 mm sq PVC copper wire lugs etc and complete of damaged burnt wiring complete.
Providing and fixing of jaw contact made of copper suitable for VCB
Providing and fixing of intraptor connecting rod
Complete overhauling proper connection & providing and fixing of missing nut & bolt proper functioning
Safely carriage of Fuse set ESC SRE to site of work including loading and unloading at both ends
Safely Installation of Fuse set and connection properly.
Laying of LT/XLPE cable 1*240 sq.mm/3.5*70 sq.mm as per respo specification.
M/s Ayushi Enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .