Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L3₹37,400Qualified Make: microtek
Model: Microtek Line Intractive 0.5\ 84 with 2 year warranty B 921 GREEN FIELDS COLONY FARIDABAD 2821 121003 INDIA | FARIDABAD | HARYANA | 121003 | Make: microtek
Model: Microtek Line Intractive 0.5\ 84 with 2 year warranty | L3 | Qualified | |
| 2 | L4₹29,750Qualified Make: microtek
Model: MICROTEK 650+UPS PRO 100 THE MALL AMBALA CANTT N N 133001 | AMBALA | HARYANA | 133001 | Make: microtek
Model: MICROTEK 650+UPS PRO | L4 | Qualified | |
| 3 | L6₹41,157Qualified Make: zebronic
Model: UPS 700 19 103 NEW MALHAR SAHARA STATES JANKIPURAM LUCKNOW UTTAR PRADESH 226021 | LUCKNOW | UTTAR PRADESH | 226021 | Make: zebronic
Model: UPS 700 | L6 | Qualified | |
| 4 | L7₹42,500Qualified Make: CyberPower
Model: Cyberpower BU600E 660 A GANDHI NAGAR JAMMU JAMMU | Make: CyberPower
Model: Cyberpower BU600E | L7 | Qualified | |
| 5 | L8₹42,670Qualified Make: Delta Power
Model: Delta VX UPA601V2100B6 BELOW SANKALP RESTAURANT AHEMDABAD GUJARAT 380052 | AHMADABAD | GUJARAT | 380052 | Make: Delta Power
Model: Delta VX UPA601V2100B6 | L8 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Sept 2018, 3:00 pmClosed
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 17 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 0.5/84 * Technology MOSFET-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP-21 IP-21
IP 20 Inverter Efficiency (%) >/= 70% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year 1 year
3 Years Warranty for Line Interactive UPS 2 Years 1 Year
2 Years
5 Years
3 Years Installation and commissioning Yes * 1/4 instructions CONSTRUCTIONAL Type of enclosure ABS * AC out put for printer (not through inverter) Yes Yes
No Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) </=0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * Protection for over voltage and over load Yes * REPORTS AND Damp heat Test at 45 Yes * 2/4 CERTIFICATIONS degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vikas Kumar 194101
330 FD REGT PIN 926330 C/o 56 APO 17 30
494271
GEM/2018/B/69970
Line Intractive UPS with AVR
30 days
Ladakh; Leh Ladakh
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Line Intractive UPS With AVR ( 17 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 0.5/84 * Technology MOSFET-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP-21 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 70% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year 1 year | - | - | - |
| 3 Years Warranty for Line Interactive UPS 2 Years 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years | - | - | - |
| 3 Years Installation and commissioning Yes * 1/4 instructions CONSTRUCTIONAL Type of enclosure ABS * AC out put for printer (not through inverter) Yes Yes | - | - | - |
| No Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) </=0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * Protection for over voltage and over load Yes * REPORTS AND Damp heat Test at 45 Yes * 2/4 CERTIFICATIONS degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vikas Kumar 194101 | - | - | - |
| 330 FD REGT PIN 926330 C/o 56 APO 17 30 | - | - | - |
Exempted
10 Sept 2018
29 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_494271.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .