Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-AOC | ₹4.0 Cr Quoted ₹3.9 Cr | L1 | Accepted-AOC Awarded |
| 2 | L1₹3.9 CrRejected-AOC SAONAGAON BONGAIGAON MULAGAON BONGAIGAON BONGAIGAON 781038 | KAMRUP METRO | ASSAM | 781038 | ₹3.9 Cr | L1 | Rejected-AOC Rejected |
| 3 | L1₹3.9 CrRejected-AOC BHAKARIVITA BONGAIGAON ASSAM PIN 783380 | BONGAIGAON | ASSAM | 783380 | ₹3.9 Cr | L1 | Rejected-AOC Rejected |
| 4 | L2₹4.3 Cr+₹43.3 L (11.1%)Rejected-AOC 3RD FLOOR KRISHNA RICE MILL BUILDING PAGLASTHAN BONGAIGAON 783380 | BONGAIGAON | ASSAM | 783380 | ₹4.3 Cr+₹43.3 L (11.1%) | L2 | Rejected-AOC Rejected |
| 5 | L3₹4.4 Cr+₹49.2 L (12.6%)Rejected-AOC ABHAYAPURI W NO 2 HOUSE NO 42 ABHAYAPURI P O PS ABHAYAPURI BONGAIGAON 783384 | BONGAIGAON | ASSAM | 783384 | ₹4.4 Cr+₹49.2 L (12.6%) | L3 | Rejected-AOC Rejected |
Tender Value
₹4.3 Cr
EMD Value
₹8.9 L
Closing Date
12 Jan 2024, 2:00 pmClosed
Chief Engineer (Roads), PWRD, Assam
O/o the Chief Engineer Roads, PWRD, Assam, Chandmari, Guwahati, 781003.
MMPPNA_23_24_22, Construction of road from Abadipara to Bhawraguri from Ch. 0.00m to Ch. 1370.00m, 2.Construction of road from No 2 Lakhijhora to No 3 Lakhijhora via No. 1 Barpathar from Ch. 0.00 m to Ch. 1895.00 m, 3.Construction of road from....
2024_PWD_35115_132
CE/DEV/TB/707/2023-24/01
Open Tender
Civil Works
Item Rate
365 days
Chirang
Please refer Tender documents.
4 documents required · 4 mandatory
₹8,890
₹8.9 L
Yes
O/o the Chief Engineer Roads, PWRD, Assam,
18 May 2024
4 Jan 2024
12 Jan 2024
4 Jan 2024
12 Jan 2024
5 Jan 2024
4 Jan 2024 - 5 Jan 2024
5 Jan 2024
Amount
Road from Abadipara to Bhawraguri road ( L = 1.370 Km) Clearing and grubbing of Road land including up rooting wild vegetation , grass, burshes, shrubs, saplings and trees of girth upto 300mm removal of stumps of trees cut earlier and disposal of unseviceable materials & stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Clause 201. (I) By Manual Means- (a) In area of non thormy jungle
Compacting Original Ground ii) Compacting original ground supporting Subgrade Loosening of the ground upto a level of 300 mm below the sub-grade level, watered, graded and compacted in layer to meet requirement of table 300.1 ND 300.2 subgrade construction as per technical specification.
Construction of embankment with approved materials obtained from borrow pits with a lift upto 1.5m transporting to site spreading, grading to required slope and compacted to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 By Mechanical Means, Private Land
Construction of sub-grade and earthen shoulders Construction of sub-grade and earthen shoulders with approved materials obtained from borrow pits with all lifts and leads, transporating to site, spreading, grading to required slope and compacting to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.01. By Mechanical Means: Private Land
Construction of Granular Sub-base by providing coarse graded material, spreeding in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause. 401 (II) For Grading II Material
Water Bound Macadam : Providing, laying, spreading and compacting stone aggregate of specific size to WBM specification including spreading in uniform thickness, hand packing rolling with vibratory roller 8-10 tones in stages to proper grade and camber, applying and brooming screening/ binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. A) By Mamual Means: (III) WBM Grading-III :
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification cl. 1504 (including of Edge restraint and carriage)
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (ii) 600 mm equilaterral triangle
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (iii) 600 mm Circular
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (v) 900 mm side octagon
Reinforced cement concrete M15 grade kilometer stone /local stone of standard design as per IRC : 8 fixing in position including painting and printing etc as per drawing and technical specification clause 1703 ii) Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometer stone /local stone of standard design as per IRC : 8 fixing in position including painting and printing etc as per drawing and technical specification clause 1703 ii) 200 meter Stone (Precast)
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top andmiddle plate duly welded with MS flat iron 25mm x 5m size on back on edges.The lower plate will be welded with MS angle iron frame of 25mm x 25mm x5mm. The angle iron frame of the lower most plate and flat iron frame of middleplate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts dulyembedded in cement concrete M-15 grade blocks of 450mm x 450mmx 600mm,600mm below ground level. The top most diamond plate will be welded to middleplate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stoveenameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in requiredshade and colour. All sections of framed posts andsteel tube will be painted withprimer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
RCC Guard Post. Supplying fitting and fixing RCC guard Post 150 mm long erected 75 cm above the ground and 75 cm below the ground with M-15 grade of cement concrete and required reinforcement tied in position with annealed black wire including centering moulding the top curing including painting concrete surface in 23 cm strips upto .0.75 m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc complete as per designed. i) 30 cm dia RCC guard Post with reinforcement of 6 nos. 12 mm dia TMT main steel bars and 6 mm TMT /MS stirrupt at 15 cm c/c.
Providing and laying boulder apron lead in wire crates made width 4mm dia GI wire conforming to IS: 280 & IS:4836 IN 100mm X 100mm mesh (Woven diagonally) including 10 percent extra for laps and joints laid with stone bolders weighing not less than 25kg each as per drawing and technical specification clause 1301.
(1.00 m x 1.00 m RCC Box Culvert = 3 Nos.) Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious mater, dressing of sides and bottom and back filling with approved material as per MORTH Clause No. 304. i. In Ordinary Soil (A) Mechnical Means Upto 3.00 m depth
Providing concrete for plain /reinforced concrete in open foundation complete as per drawing and technical specification clause 802,803,1202 & 1203
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 A. with crushed stone IV. RCC M-25 Grade
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer : TATA/ SAIL/Essar Steel/Jindal Steel/Shyam Steel/RINL) in sub-structure complete as per drawing and technical specification clauses 1002, 1005, 1010 & 1202
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Providing and laying boulder apron lead in wire crates made width 4mm dia GI wire conforming to IS: 280 & IS:4836 in 100mm X 100mm mesh (Woven diagonally) including 10 percent extra for laps and joints laid with stone bolders weighing not less than 25kg each as per drawing and technical specification clause 1301.
Utility Shifting
No.2 Lakhijhora to No.3 Lakhijhora via No.1 Barpathar ( L=1.895 Km ) Clearing and grubbing of Road land including up rooting wild vegetation , grass, burshes, shrubs, saplings and trees of girth upto 300mm removal of stumps of trees cut earlier and disposal of unseviceable materials & stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Clause 201. (I) By Manual Means- (a) In area of non thormy jungle.
Compacting Original Ground ii) Compacting original ground supporting Subgrade Loosening of the ground upto a level of 300 mm below the sub-grade level, watered, graded and compacted in layer to meet requirement of table 300.1 ND 300.2 subgrade construction as per technical specification.
Construction of embankment with approved materials obtained from borrow pits with a lift upto 1.5m transporting to site spreading, grading to required slope and compacted to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 By Mechanical Means, Private Land
Construction of sub-grade and earthen shoulders Construction of sub-grade and earthen shoulders with approved materials obtained from borrow pits with all lifts and leads, transporating to site, spreading, grading to required slope and compacting to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.01. By Mechanical Means: Private Land
Construction of Granular Sub-base by providing coarse graded material, spreeding in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause. 401 (II) For Grading II Material
Water Bound Macadam : Providing, laying, spreading and compacting stone aggregate of specific size to WBM specification including spreading in uniform thickness, hand packing rolling with vibratory roller 8-10 tones in stages to proper grade and camber, applying and brooming screening/ binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. A) By Mamual Means: (III) WBM Grading-III :
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification cl. 1504 (including of Edge restraint and carriage)
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (ii) 600 mm equilaterral triangle
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (iii) 600 mm Circular
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (v) 900 mm side octagon
Reinforced cement concrete M15 grade kilometer stone /local stone of standard design as per IRC : 8 fixing in position including painting and printing etc as per drawing and technical specification clause 1703 ii) Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometer stone /local stone of standard design as per IRC : 8 fixing in position including painting and printing etc as per drawing and technical specification clause 1703 ii) 200 meter Stone (Precast)
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top andmiddle plate duly welded with MS flat iron 25mm x 5m size on back on edges.The lower plate will be welded with MS angle iron frame of 25mm x 25mm x5mm. The angle iron frame of the lower most plate and flat iron frame of middleplate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts dulyembedded in cement concrete M-15 grade blocks of 450mm x 450mmx 600mm,600mm below ground level. The top most diamond plate will be welded to middleplate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stoveenameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in requiredshade and colour. All sections of framed posts andsteel tube will be painted withprimer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
RCC Guard Post. Supplying fitting and fixing RCC guard Post 150 mm long erected 75 cm above the ground and 75 cm below the ground with M-15 grade of cement concrete and required reinforcement tied in position with annealed black wire including centering moulding the top curing including painting concrete surface in 23 cm strips upto .0.75 m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc complete as per designed. i) 30 cm dia RCC guard Post with reinforcement of 6 nos. 12 mm dia TMT main steel bars and 6 mm TMT /MS stirrupt at 15 cm c/c.
(3.00 m x 3.00 m Double Cell RCC Box Culvert = 1 No.) Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious material and disposal up to alead of 50 m, , dressing of sides and bottom and back filling in trenches with excavated suitable material. i. In Ordinary Soil ii.Upto 3.00 m depth
Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9 (i) Sand filling
Providing concrete for plain/Reinforced concrete in open foundation complete as per drawing and technical specificationclause 802. i) PCC grade M-10
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 IV. RCC M-25 Grade
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer : TATA/ SAIL/Essar Steel/Jindal Steel/Shyam Steel/RINL) in sub-structure complete as per drawing and technical specification clauses 1002, 1005, 1010 & 1202
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Drainage spouts complete as per drawing and technical specifications Clause 120.9
Construction of RCC Railing of M30 Grade in-situ with 20mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceede 1 in 500, center to center spacing between vertical post not to exceed 2000mm, as per drawing and technical specification clause 800, 900 & 1208.3
Providing and laying filter materials underneath pitching in slopes complete as per drawing and technical specification.
Providing and laying pitching on slopes laid over prepared media as per drawing and technical specification, clause 1302. (1) Stone/Boulder
Providing and laying boulder apron lead in wire crates made width 4mm dia GI wire conforming to IS: 280 & IS:4836 IN 100mm X 100mm mesh (Woven diagonally) including 10 percent extra for laps and joints laid with stone bolders weighing not less than 25kg each as per drawing and technical specification clause 1301.
(2.00 m x 2.00 m, single Cell l RCC Box Culvert = 2 Nos.) Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious material and disposal up to alead of 50 m, , dressing of sides and bottom and back filling in trenches with excavated suitable material. i. In Ordinary Soil ii.Upto 3.00 m depth
Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9 (i) Sand filling
Providing concrete for plain/Reinforced concrete in open foundation complete as per drawing and technical specificationclause 802. i) PCC grade M-10
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 IV. RCC M-25 Grade
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer : TATA/ SAIL/Essar Steel/Jindal Steel/Shyam Steel/RINL) in sub-structure complete as per drawing and technical specification clauses 1002, 1005, 1010 & 1202
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification.
Providing and laying boulder apron lead in wire crates made width 4mm dia GI wire conforming to IS: 280 & IS:4836 IN 100mm X 100mm mesh (Woven diagonally) including 10 percent extra for laps and joints laid with stone bolders weighing not less than 25kg each as per drawing and technical specification clause 1301.
(1.00 m x 1.00 m RCC Box Culvert = 2 Nos.) Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious mater, dressing of sides and bottom and back filling with approved material as per MORTH Clause No. 304. i. In Ordinary Soil (A) Mechnical Means Upto 3.00 m depth
Providing concrete for plain /reinforced concrete in open foundation complete as per drawing and technical specification clause 802,803,1202 & 1203
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 A. with crushed stone IV. RCC M-25 Grade
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer : TATA/ SAIL/Essar Steel/Jindal Steel/Shyam Steel/RINL) in sub-structure complete as per drawing and technical specification clauses 1002, 1005, 1010 & 1202
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Providing and laying boulder apron lead in wire crates made width 4mm dia GI wire conforming to IS: 280 & IS:4836 in 100mm X 100mm mesh (Woven diagonally) including 10 percent extra for laps and joints laid with stone bolders weighing not less than 25kg each as per drawing and technical specification clause 1301.
Utility Shifting
No. 3 Bishnupur to Sikajhora No 2 Bihari Basti ( L =1.250 Km) Clearing and grubbing of Road land including up rooting wild vegetation , grass, burshes, shrubs, saplings and trees of girth upto 300mm removal of stumps of trees cut earlier and disposal of unseviceable materials & stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Clause 201. (I) By Manual Means- (a) In area of non thormy jungle.
Compacting Original Ground ii) Compacting original ground supporting Subgrade Loosening of the ground upto a level of 300 mm below the sub-grade level, watered, graded and compacted in layer to meet requirement of table 300.1 ND 300.2 subgrade construction as per technical specification.
Construction of embankment with approved materials obtained from borrow pits with a lift upto 1.5m transporting to site spreading, grading to required slope and compacted to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 By Mechanical Means, Private Land
Construction of sub-grade and earthen shoulders Construction of sub-grade and earthen shoulders with approved materials obtained from borrow pits with all lifts and leads, transporating to site, spreading, grading to required slope and compacting to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.01. By Mechanical Means: Private Land
Construction of Granular Sub-base by providing coarse graded material, spreeding in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause. 401 (II) For Grading II Material
Water Bound Macadam : Providing, laying, spreading and compacting stone aggregate of specific size to WBM specification including spreading in uniform thickness, hand packing rolling with vibratory roller 8-10 tones in stages to proper grade and camber, applying and brooming screening/ binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. A) By Mamual Means: (III) WBM Grading-III :
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification cl. 1504 (including of Edge restraint and carriage)
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (ii) 600 mm equilaterral triangle
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (iii) 600 mm Circular
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (v) 900 mm side octagon
Reinforced cement concrete M15 grade kilometer stone /local stone of standard design as per IRC : 8 fixing in position including painting and printing etc as per drawing and technical specification clause 1703 ii) Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometer stone /local stone of standard design as per IRC : 8 fixing in position including painting and printing etc as per drawing and technical specification clause 1703 ii) 200 meter Stone (Precast)
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top andmiddle plate duly welded with MS flat iron 25mm x 5m size on back on edges.The lower plate will be welded with MS angle iron frame of 25mm x 25mm x5mm. The angle iron frame of the lower most plate and flat iron frame of middleplate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts dulyembedded in cement concrete M-15 grade blocks of 450mm x 450mmx 600mm,600mm below ground level. The top most diamond plate will be welded to middleplate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stoveenameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in requiredshade and colour. All sections of framed posts andsteel tube will be painted withprimer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
RCC Guard Post. Supplying fitting and fixing RCC guard Post 150 mm long erected 75 cm above the ground and 75 cm below the ground with M-15 grade of cement concrete and required reinforcement tied in position with annealed black wire including centering moulding the top curing including painting concrete surface in 23 cm strips upto .0.75 m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc complete as per designed. i) 30 cm dia RCC guard Post with reinforcement of 6 nos. 12 mm dia TMT main steel bars and 6 mm TMT /MS stirrupt at 15 cm c/c.
Providing and laying boulder apron lead in wire crates made width 4mm dia GI wire conforming to IS: 280 & IS:4836 in 100mm X 100mm mesh (Woven diagonally) including 10 percent extra for laps and joints laid with stone bolders weighing not less than 25kg each as per drawing and technical specification clause 1301.
(3.00 m x 3.00 m Double Cell RCC Box Culvert = 1 No.) Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious material and disposal up to alead of 50 m, , dressing of sides and bottom and back filling in trenches with excavated suitable material. i. In Ordinary Soil ii.Upto 3.00 m depth
Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9 (i) Sand filling
Providing concrete for plain/Reinforced concrete in open foundation complete as per drawing and technical specificationclause 802. i) PCC grade M-10
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 IV. RCC M-25 Grade
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer : TATA/ SAIL/Essar Steel/Jindal Steel/Shyam Steel/RINL) in sub-structure complete as per drawing and technical specification clauses 1002, 1005, 1010 & 1202
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Drainage spouts complete as per drawing and technical specifications Clause 120.9
Construction of RCC Railing of M30 Grade in-situ with 20mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceede 1 in 500, center to center spacing between vertical post not to exceed 2000mm, as per drawing and technical specification clause 800, 900 & 1208.3
Providing and laying filter materials underneath pitching in slopes complete as per drawing and technical specification.
Providing and laying pitching on slopes laid over prepared media as per drawing and technical specification, clause 1302. (1) Stone/Boulder
Providing and laying boulder apron lead in wire crates made width 4mm dia GI wire conforming to IS: 280 & IS:4836 IN 100mm X 100mm mesh (Woven diagonally) including 10 percent extra for laps and joints laid with stone bolders weighing not less than 25kg each as per drawing and technical specification clause 1301.
(2.00 m x 2.00 m, single Cell l RCC Box Culvert = 2 Nos.) Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious material and disposal up to alead of 50 m, , dressing of sides and bottom and back filling in trenches with excavated suitable material. i. In Ordinary Soil ii.Upto 3.00 m depth
Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9 (i) Sand filling
Providing concrete for plain/Reinforced concrete in open foundation complete as per drawing and technical specificationclause 802. i) PCC grade M-10
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 IV. RCC M-25 Grade
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer : TATA/ SAIL/Essar Steel/Jindal Steel/Shyam Steel/RINL) in sub-structure complete as per drawing and technical specification clauses 1002, 1005, 1010 & 1202
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification.
Providing and laying boulder apron lead in wire crates made width 4mm dia GI wire conforming to IS: 280 & IS:4836 IN 100mm X 100mm mesh (Woven diagonally) including 10 percent extra for laps and joints laid with stone bolders weighing not less than 25kg each as per drawing and technical specification clause 1301.
(1.00 m x 1.00 m RCC Box Culvert = 1 Nos.) Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious mater, dressing of sides and bottom and back filling with approved material as per MORTH Clause No. 304. i. In Ordinary Soil (A) Mechnical Means Upto 3.00 m depth
Providing concrete for plain /reinforced concrete in open foundation complete as per drawing and technical specification clause 802,803,1202 & 1203
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 A. with crushed stone IV. RCC M-25 Grade
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer : TATA/ SAIL/Essar Steel/Jindal Steel/Shyam Steel/RINL) in sub-structure complete as per drawing and technical specification clauses 1002, 1005, 1010 & 1202
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Providing and laying boulder apron lead in wire crates made width 4mm dia GI wire conforming to IS: 280 & IS:4836 in 100mm X 100mm mesh (Woven diagonally) including 10 percent extra for laps and joints laid with stone bolders weighing not less than 25kg each as per drawing and technical specification clause 1301.
Utility Shifting
Sri Bipul Choudhury
MR NABAJYOTI BARMAN
PADMAVATI CONSTRUCTION
RABIN CHANDRA SARKAR
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .