| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹37.9 L+₹1.1 L (2.91%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹42.4 L+₹5.6 L (15.2%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹44.7 L+₹7.9 L (21.4%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹45.4 L+₹8.6 L (23.2%)Rejected-Finance MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
21 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIR AND MAINTAIN OF STORAGE WATER HEATER (GEYSER) AND REPLACEMENT OF OLD VINTAGE UNSV GEYSER AND CERTAIN MISC WORK UNDER GE (W) JABALPUR
2024_MES_675788_1
8795/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹96,000
5 Dec 2024
23 Sept 2024
26 Oct 2024
24 Sept 2024
21 Oct 2024
7 Oct 2024
24 Sept 2024 - 1 Oct 2024
Amount
M& L for comprehensive maintenance and overhauling of Geyser 25/50 Ltrs of any make and size including following works (a) Checking proper working of geysers. (b) Checking of pvc pipe/safety valve/heating element/flange/thermostat including replacement of unseviceable part (c) Replacement of unserviceable bottom cover plate/pvc pipe/heating element/thermostat/indicating lamp. (d) Cleaning of geyser 25/50 Ltr . Note : 1.Contractor has to depute two team of 01xelectrician & 01x helper daily from commencement of work to till completion of work for day to day maintenance/execution of work as per CA, who will report to JE E/M in mes YARD under AGE E/M E/S. If contractor is fail to doing so, penalty of Rs 500 per day per team shall deducted from RAR. 2. Unserviceable parts to be measured & paid seperately under relevant item of Sch A. All Tools & Plants incl transportation for shifting of geyser from user's accn to yard for repair/deposit and ladder provided to electrician at site by the contractor.
Taking down carefully storage type water heater of any make and capacity from clamps/bolts including disconnection water and electric connection and refixing the same and connecting up after cleaning of geyser and repairs complete all as specified and as directed.
Repair of inner flange of 25/50 Ltrs geysers and replacement of worn-out stud brazing with gas welding not exceeding 5mm thick complete all as specified and as directed.
Supply and fix in replacement geyser flange assembly (any make/type) copper alloy chromium plates suitable for 25 Ltrs capacity including rubber gasket, clamps and nuts/bolts etc complete all as specified and as directed.
Ditto all as per Srl Item No 4 above but 50 Ltrs complete all as specified and as directed.
Supply and fix and connecting heating element ( triangular or circular base type) 1.5 KW 230 volts suitable for 25 ltrs capacity geysers in replacement of old unserviceable heating element complete all as specified and as directed.
Supply and fix and connecting heating element ( triangular or circular base type) 2 KW, 230 volts suitable for 50 ltrs capacity geysers in replacement of old unserviceable heating element complete all as specified and as directed.
S&F in replacement thermostat of existing type/make complete or 25 Ltrs geyser all as specified and as directed.
S&F in replacement thermostat of existing type/make complete or 50 Ltrs geyser all as specified and directed.
S&F in replacement indicating lamp, 230 volts as per site requirement complete all as specified and as directed.
S&F in replacement 15mm bore GI tube medium grade fixed to wall/geyser into short places including cutting, screwing, threading and all GI fittings (including union, socket if required) complete all as specified and as directed.
S&F in replacement geyser bottom cover complete including machine screws etc. as per original size and shape of any make of geyser 25 ltrs capacity complete all as specified and as directed.
Ditto all as per Srl Item No12 above but 50 ltrs capacity complete all as specified and as directed.
S&F brass chromium plated flexible pipe connection heavy duty suitable for hot water supply with two Nos brass chromium plated union 450 mm long in replacement of PVC pipe connection complete all as specified and as directed.
S&F in replacement non return valve of 15mm size of brass for geyser (weight of valve shall not be less than 400 grams) complete all as specified and as directed.
M&L for painting of geyser with two coats of synthetic enamel white paint and writing the MES No. (letter not less than 1.5 cm height)for 25 ltrs capacity geyser of any make and type complete all as specified and as directed.
Ditto all as per Srl Item No. 16 above but 50 ltrs capacity.
S&F in replacement stop valve cast copper alloy 15mm bore a inlet or outlet connection of geysers complete all as specified and as directed.
S&F in replacement PVC insulated over all PVC sheathed three core copper cable of size 40/0.193 including disconnection of old cable complete all as specified and as directed.
S&F Pressure release valve suitable for 25/50 ltrs any make any type of geyser complete in replacement of dead weight complete all as specified and as directed.
Removing old glass wool for the geysers and providing new glass wool of equal thickness and specification :-
(a) Capacity 25 Ltrs
(b) Capacity 50 Ltrs
S&F three pin top 15 Amp 240 volts complete all as specified and as directed
S&F Top for earth plug socket 20 Amps AC 240 Volts complete all as specified and as directed.
S&F of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of size 20 Amps. Complete all as required and as directed at site.
S&F the safety valve suitable for geyser 25/50 litres complete all as per site required.
M&L of Sub main wiring with two single core PVC Insulated cable two run of size 2.5 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 20 mm dia with all conduit accessories and one run of 2.5 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and as directed. Note : - Two runs of 2.5 Sqmm & one run of 2.5 Sqmm cable shall be measured as one unit run.
M&L of Sub main wiring with two single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and as directed. Note : - Two runs of 4 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run.
M&L of Sub main wiring with two single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and as directed. Note : - Two run of 6 Sqmm & one run of 6 Sqmm cable shall be measured as one unit run.
M&L of Sub main wiring with two single core PVC Insulated cable two run of size 10.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 10.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and as directed. Note : - Two runs of 10 Sqmm & one run of 10 Sqmm cable shall be measured as one unit run.
Taking down to carefully storage type water heater of any make and any capacity from clamps/bolts including disconnection water and electric connection and deposit to MES Yard (E/S) Store complete all as specified and as directed.
Supplying and fixing,testing the water heater storage type 25 litres, BEE Five star Rated capacity and after connecting electric and water connection and screwing nuts and bolts , anchor hold fast to fixed on wall and making the good the disturbed surface, complete all as required and as directed at site.
Supplying and fixing,testing the water heater storage type 6 litres, BEE Five star Rated capacity and after connecting electric and water connection and screwing nuts and bolts , anchor hold fast to fixed on wall and making the good the disturbed surface, complete all as required and as directed at site.
Supplying and fixing,testing the water heater storage type 50 litres, BEE Five star Rated capacity and after connecting electric and water connection and screwing nuts and bolts , anchor hold fast to fixed on wall and making the good the disturbed surface, complete all as required and as directed at site.
S & F in repair Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick over and including 10mm thick cement plaster in CM 1:4 set or as per existing and jointed in neat cement slurry and pointed in white or colour cement to match existing surfaces complete all as specified and as directed.
M& L Complete removal of existing treatment Washing, rubbing down and stopping of distempered and painted surfaces of wall and then applying two coats of oil bound distemper over and including 2mm thick wall care putty over a coat of chalk whitening primer including preparation complete all as specified and as directed.
S&F of stop valves, CP, screwed down, high pressure, with crutch or butterfly handle , screwed both ends for iron pipe or for unions and fixed of size 15mm complete all as specified and as directed.
Supply and fixing Brass CP mixer for mixing hot & cold water screwed down for iron pipeof size 15mm bore complete all as specified and as directed.
S&F for MCB Single Pole and Neutral 240Volt, 63 Amps,10KA breaking capacity complete all as specified and as directed.
Supply and fixing in replacement MCB single pole 240 volts upto 40 Amps, B Series complete all as specified and as directed.
S&F in replacement MCB Single Pole 240Volt, 5 to 32 Amps,10KA 'B' curve breaking capacity complete all as specified and as directed..
AYANSH ASSOCIATES (BID ID -3138505)
Sachdeva Enterprises (BID ID -3138433)
mandeka constructions (BID ID -3145210)
RAVINDRA ELECTRICAL (BID ID -3139119)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .