Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Performance certificate not submitted |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
16 Apr 2025, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, STD-II, Rajbagh,Srinagar
Office of the Executive Engineer, STD-II RAJBAGH
Annual rate contract for repairs and maintenance of 33kv lines falling under the jurisdiction of Sub Transmission Division-II, Rajbagh, for the year 2025-26 or till next rate contract.
2025_PDD_274720_1
eNIT No STD-II / 02 of 2025-26 Dated 19-03-2025
Open Tender
Electrical and Maintenance Works
Item Rate
1 days
Rajbagh
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, STD-II, Rajbagh,Srinagar
₹30,000
30 Apr 2025
22 Mar 2025
17 Apr 2025
24 Mar 2025
16 Apr 2025
24 Mar 2025
Amount
Supply and Erection of 13 mtr Long ST Pole (ST-410SP-69) with base plate and top cap including excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard
Erection of 13 mtr Long ST Pole (ST-410SP-69) with base plate and top cap including excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard, including loading, unloading and transportation from Divisional store to the site of erection.(ST pole to be provided by deparment)
Supply and Erection of 11mtr Long ST Pole (ST-410SP-56) with base plate and top cap including excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard
Erection of 11 mtr Long ST Pole (ST-410SP-56) with base plate and top cap including excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard, including loading, unloading and transportation from Divisional store to the site of erection.(ST pole to be provided by deparment)
Supply and Erection of 9mtr Long ST Pole (ST-410SP-33) with base plate and top cap including excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard
Erection of 9 mtr Long ST Pole (ST-410SP-33) with base plate and top cap including excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard (ST pole to be supplied by deparment), including loading, unloading and transportation from Divisional store to the site of erection.(ST pole to be provided by deparment)
Dismantling of 13 mtr Long ST Pole (ST-410SP-69) with allied accessies,including loading, unloading upto the divisional stores.
Dismantling of 11mtr Long ST Pole (ST-410SP-56) with allied accessies including loading, unloading upto the divisional stores
Dismantling of 9mtr Long ST Pole (ST-410SP-33) with allied accessies including loading, unloading upto the divisional stores
Dismantling of wooden poles of different sizes complete with allied accessies including loading, unloading upto the divisional stores
Straightening of existing tilted 13 mtr Long ST Pole
Straightening of existing tilted 11 mtr Long ST Pole
Straightening of existing tilted 9mtr Long ST Pole
Straightening of existing tilted DW Wooden Pole
Providing and Painting of 13mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade
Providing and Painting of 11mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade
Providing and Painting of 9mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade
Painting of 13mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade
Painting of 11mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade
Painting of 9mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade
Providing and laying of Cement bottoming of 13mtr Long ST Poles in mix 1:2:4 ( as per REC construction standard) using 20mm crush stone aggregate including shuttering ,form work etc.(0.7 cum)
Providing and laying of Cement bottoming of 11mtr Long ST Poles in mix 1:2:4 ( as per REC construction standard) using 20mm crush stone aggregate including shuttering ,form work etc. (0.6 cum)
Providing and laying of Cement bottoming of 9mtr Long ST Poles in mix 1:2:4 ( as per REC construction standard) using 20mm crush stone aggregate including shuttering ,form work etc. (0.5cum)
Providing and fixing of Galvanised spiral Earthing (in a separate pit) of 8 SWG, G.I wire of 115 turns confirming to REC-J1 construction standard
Fixing of Galvanised spiral Earthing (in a separate pit) of 8 SWG, G.I wire of 115 turns confirming to REC-J1 construction standard
Providing and Fixing of Earthing complete with by GI Pipe 40mm or GI rod 20mm 2.5m long through GI strip
Fixing of Earthing complete with by GI Pipe 40mm or GI rod 20mm 2.5m long through GI strip
Providing and fixing of 33KV Galvanised Guy Set(Guy wire,Guy Rods,Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof (complete)
Fixing of 33KV Galvanised Guy Set(Guy wire,Guy Rods,Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof (complete)
Dismanteling of 33KV Galvanised Guy Set(Guy wire,Guy Rods,Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof (complete) including loading, unloading upto the divisional stores
Providing and fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.1 ACSR
Providing and fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.15ACSR
Providing and fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.2 ACSR
Fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to (Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.1 ACSR
Fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to (Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.15 ACSR
Fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to (Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.2ACSR
Laying,stringing ,tensioning and binding of 0.2 ACSR Conductor as per REC Construction standard including loading, unloading and transportation from Divisional store to the site of erection (material to be provided by the department)
Laying,stringing ,tensioning and binding of 0.15 ACSR Conductor as per REC Construction standard including loading, unloading and transportation from Divisional store to the site of erection (material to be provided by the department)
Laying,stringing ,tensioning and binding of 0.1 ACSR Conductor as per REC Construction standard including loading, unloading and transportation from Divisional store to the site of erection (material to be provided by the department)
Laying,stringing ,tensioning and binding of 0.05ACSR Conductor as per REC Construction standard including loading, unloading and transportation from Divisional store to the site of erection (material to be provided by the department)
Supply,Laying,stringing ,tensioning and binding of 0.2 ACSR Conductor as per REC Construction standard
Supply,Laying,stringing ,tensioning and binding of 0.15 ACSR Conductor as per REC Construction standard
Supply,Laying,stringing ,tensioning and binding of 0.1 ACSR Conductor as per REC Construction standard
Supply,Laying,stringing ,tensioning and binding of 0.05 ACSR Conductor as per REC Construction standard
Re-stringing of 0.2 ACSR Conductorincluding tensioning, binding etc
Re-stringing of 0.15 ACSR Conductorincluding tensioning, binding etc
Re-stringing of 0.1ACSR Conductorincluding tensioning, binding etc
Unloading of 13 mtr Long ST Pole (ST-410SP-69) including manual carriage (manual) upto dumping site( divisional store) and then proper stacking upto a lead of 25mtr
Unloading of 11 mtr Long ST Pole (ST-410SP-56) including manual carriage (manual) upto dumping site( divisional store) and then proper stacking upto a lead of 25mtr
Unloading of 9mtr Long ST Pole (ST-410SP-33) including manual carriage (manual) upto dumping site( divisional store) and then proper stacking upto a lead of 25mtr
Manual Carriage of ST Poles Upto first 100mtr lead
Manual Carriage of ST Poles for every additional 50mtr or part there off
Unloading of 33KV Pin/Disc insulators, 11KV Pin/Disc inslators, including manual carriage, proper stacking and sorting etc
Unloading of 33KV isolators with /without earthings blades, 11KV isolators , including manual carriage, proper stacking and sorting etc
Unloading of Steel and sundry items like CGI sheet, nuts and bolts, Angle Iron, hardware fittings , cross arms etc including manual carriage, proper stacking and sorting etc
Unloading of cables of all sorts including manual carriage, proper stacking.
Manual Carriage of Sundry Items Upto first 100mtr lead
Manual Carriage of Sundry Items for every additional 50mtr or part there off
Unloading of of Conductor Reels ( 0.1ACSR/ 0.2 ACSR/ 0.15 ACSR ) including manual carriage stacking site upto loading
Supply, installation,testing and commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting
Installation,testing and commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting, including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Supply,installation,Testing and commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Installation,Testing and commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm, including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Supply,installation,Testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Installation,Testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm, including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Providing and fixing o 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting
Fixing 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting, including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Providing and fixing of danger plates (6"X8"X4mm thick) with clamps
Fixing of danger plates (6"X8"X4mm thick) with clamps
Providing and fixing of anti climbing devices with clamps
Fixing of anti climbing devices with clamps
Providing and fixing of fabricated GI Channel / Angle Iron of sorts as per site requirement
Fixing of fabricated GI Channel / Angle Iron of sorts as per site requirement, including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Providing and Fixing of jumper sets (3 pieces) for 33KV line
Fixing of jumper sets (3 pieces) for 33KV line
Supply,laying,testing and commissioning of 33KV, 185sqmm Single core Aluminium, round wire Armoured XLPE Cable , FRLS
Supply,laying,testing and commissioning of 33KV, 240sqmm Single core Aluminium, round wire Armoured XLPE Cable , FRLS
Supply,laying,testing and commissioning of 33KV, 300sqmm Single core Aluminium, round wire Armoured XLPE Cable , FRLS
Supply,laying,testing and commissioning of 33KV,400sqmm Single core Aluminium, round wire Armoured XLPE Cable , FRLS
Supply,laying,testing and commissioning of 33KV,630sqmm Single core Aluminium, round wire Armoured XLPE Cable , FRLS
Laying,testing and commissioning of 33KV, 185sqmm Single core Aluminium, round wire armoured XLPE Cable, including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Laying,testing and commissioning of 33KV, 240sqmm Single core Aluminium, round wire armoured XLPE Cable, including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Laying,testing and commissioning of 33KV, 300sqmm Single core Aluminium, round wire armoured XLPE Cable, including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Laying,testing and commissioning of 33KV, 400sqmm Single core Aluminium, round wire armoured XLPE Cable, including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Laying,testing and commissioning of 33KV, 630sqmm Single core Aluminium, round wire armoured XLPE Cable, including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Providing and Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 185sqmm Single core Aluminium, round wire armoured XLPE Cable
Providing and Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 240sqmm Single core Aluminium, round wire armoured XLPE Cable
Providing and Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 300sqmm Single core Aluminium, round wire armoured XLPE Cable
Providing and Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 400sqmm Single core Aluminium, round wire armoured XLPE Cable
Providing and Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 630sqmm Single core Aluminium, round wire armoured XLPE Cable
Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 185sqmm Single core Aluminium, round wire armoured XLPE Cable
Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 240sqmm Single core Aluminium, round wire armoured XLPE Cable
Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 300sqmm Single core Aluminium, round wire armoured XLPE Cable
Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 400sqmm Single core Aluminium, round wire armoured XLPE Cable
Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 630sqmm Single core Aluminium, round wire armoured XLPE Cable
Providng and fixing of guard netting of existing 33KV line using 8 SWG GI wire comprising of minimum of 10 No. crossing per span complete with eye bolts
Fixing of guard netting of existing 33KV line using 8 SWG GI wire comprising of minimum of 10 No. crossing per span complete with eye bolts
Providing and fixing of MS Angle Iron /Channel Iron
Fixing of MS Angle Iron /Channel Iron including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Providing and fixing Aluminium Jointing Sleeves
Fixing Aluminium Jointing Sleeves
Supply, installation,testing and commissioning of 33 kV Isolator with Earthing Blade (36kV,800A, Outdoor, 3 poles, 25 kA)
Supply, installation,testing and commissioning of 33 kV Isolator without Earthing Blade (36kV,800A, Outdoor, 3 poles, 25 kA)
Installation,testing and commissioning of 33 kV Isolator with Earthing Blade (36kV,800A, Outdoor, 3 poles, 25 kA), including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Installation,testing and commissioning of 33 kV Isolator without Earthing Blade (36kV,800A, Outdoor, 3 poles, 25 kA), including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Supply,Installation,testing and commissioning of 11 kV Isolator, Double Break,3-pole, 630 Amp, horizontal mounting Type, with Earth Switch, including loading, unloading and transportation from Divisional store to the site of erection.(Material to be provided by deparment)
Installation,testing and commissioning of 11 kV Isolator, Double Break,3-pole, 630 Amp, horizontal mounting Type, with Earth Switch.
Extensive Branch cutting of trees coming in the coridor 33KV line including cutting of trees beneath the 33KV line and stacking of serviceable material and disposal of unservicable material.(complete job)
Felling trees of the grith (measured at height of 1mtr above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.
Beyond 30cm girth upto and including 60cm girth
Beyond 60cm girth upto and including 120cm girth
Beyond 120cm girth upto and including 240cm girth
Above 240cm grith
Note: The material utilized/works executed shall be stritctly as per REC Standards with Latest amendments there off.
M/S WATT ELECTRICAL CONTRACTS (BID ID -2356660)
M/S TANTRAY ELECTRICALS (BID ID -2357732)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .