Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC HOUSE NO 99 3RD FLOOR SK JAIN BUILDING KALIBARI ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹10.1 L+₹41,775 (4.32%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹10.4 L+₹68,875 (7.13%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
9 Jan 2021, 6:00 pmClosed
AGE I ZAKHAMA
AGE (I) Zakhama C/o 792 FPO PIN-900792 C/O 99 APO
REPAIR/MAINT/REWIRING OF INTERNAL ELECTRIFICATION, WITH REPLACEMENT OF FITTINGS AND FIXTURES OF ZONE B ZAKHAMA MILITARY STATION
2020_MES_394015_3
8923 inter elect zone B zak
Open Tender
Civil Works
Item Rate
180 days
ZAKHAMA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
AGE I Zakhama
₹18,000
Yes
29 Jun 2021
24 Dec 2020
11 Jan 2021
24 Dec 2020
9 Jan 2021
26 Dec 2020
Amount
Taking down carefully point wiring copper/aluminum (light, fan, socket complete) including unserviceable battens or from existing conceal conduit including earth continuity wire and fittings such as switches, socket, ceiling roses,lamp holder,bell etc but excluding light fittings and making good disturbed surfaces of wall/ceiling etc complete all as specified and directed
M&L for point wiring (surface type) with 1.5 Sqmm PVC, FRLS, insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in and including PVC casing / caping of required width with all necessary fittings and fixing accessories( junction and terminal boxes, all fittings such as tees, bends, elbows, etc.all as per site requirements ) including PVC switch board for mounting switches/socket etc including 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth dolly for one light / ceiling fan/exhaust fan/bell etc controlled by one switch complete all as specified and directed. Note: colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green
All as per item no 2 above but for 15 amp switch socket combination by using 2.5 sqmm copper cable with 2.5 sqmm earthing wire complete all as specified and directed.
All as per item No 2 above but for 3 pin, 5 Amp Socket on the same board complete all as specified and directed.
All as per item No 2 above but for 3 pin,5 Amp switch Socket combination on independent board complete all as specified and directed.
All as per item No 2 above but for one 3 pin 5 Amps switch socket combination independent but below the switch board of light points in the same vertical plane, with cables, 1.5 sq. mm size complete all as specified and directed.
All as per item No 2 above but for bell/ buzzer point controlled by one push button on independent board complete all as specified and directed.
S&F socket outlet 2 in 1 ,3 pin 5 Amps on the same board of light points in the same vertical plane, with other switch complete all as specified and directed by engineer incharge.
S&F switch socket combination 2 in 1 ,3 pin 5 Amps on the independent board with other switch complete all as specified and directed .
Supply & fix Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal controlled by one switch flush type complete all as specified and directed .
S&F Bell, AC, 230V, Single pole,complete all as specified and directed
S&F Bell push button, flush type 5 Amp,complete all as specified and directed
S&F ceiling rose surface back light 65 x 25mm, three terminal.complete all as specified and directed
S&F switch piano flush button single pole one way 5 amps.complete all as specified and directed
Taking down old/ unserviceable light fitting etc of any type including all accessories complete all as specified and directed
M&L for lamp holder ,angle type , PVC/Polycarbonate type with back plate suitable for batten fittings. complete all as specified and directed
S & F E-Lite LED Pride Plus Decorative ultra slim round profile 20 W LED, 6000 K, lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack all as per Havells Cat No LHEXBLP7PN1W020 or eqvt make of Philips, Bajaj, Havells
S&F LED T/L 20 W, Fixture size (1150x25x40) mm (for 20 W), complete with batten and luminaries and as per the technical spevifications given below . Note:LED used shall conform to IS- 16103: 2012 &IS-16101:2012 should be of SMD type only. ii. LED efficiency shall be greater than 100 lumens per Watt/ max latest efficacy available. iii. Colour rendering index (CRI: Greater than or equal to 70). iv. Min efficiency of driver: 85%. v. Power factor of complete fitting: Greater than 0.95. vi. Input Operating Voltage: 140 V to 277V AC. vii. In-built high and low voltage cut-offs: 140 V Low and 277 (high). viii. Short circuit, Over load protection. ix. Housing of luminaries: Pressure die-cast aluminum LM6/ADC 12/LM 24housing Make : Havells/Bajaj or as approved.
S&F LED bulk head luminaires 10 W 6000k Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head Back-lit LED luminaire comprising of high brightness LEDs. complete all as directed. Make-Havells Cat No.HEXAFT10WLED857SSYMBOPC or eqvt make.
S&F LED lamps 10W, LM 80 tested LED technology,Wide voltage range 150-300VAC complete as directed by Engr in Charge. Make -Wipro or eqvt make of philips, bajaj, Havells
Taking down old unserviceable DB/Main switches incuding MCBs,PVC block of any size and type and removing complete all as specified and directed
S&F PVC rectangular block of size 250x200x50 mm depth, 3.0 mm thick including taking down old one complete all as specified and directed
S&F PVC rectangular block of size 100x100x50mm depth, 3.0 mm thick including taking down old one complete all as specified and directed
S&F sheet metal enclosure for DB when MCB to be used 8 way 200 amp rated bus bar, SPN 240V, double door complete all as specified and directed..
S&F sheet metal enclosure for DB when MCB to be used 2 way, SPN 240V single door without bus bar complete all as specified and directed..
S&F MCB Single pole and neutral 240 Volts, 6-32. Amps, 10 A,C-series,Make -havells, cat No.DHMGCSNF006-032 or same as equivalent.
S&F MCB Single pole 240 Volts, 6-32. Amps, 10 A,C-series,Make -havells, cat DHMGCSPF006-032 or same as equivalent.
Taking down unserviceable service wire/sub main wiring of any size and rating complete all as directed.
S & F 1100 Volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire, twin core 6 sqmm cable . complete all as specified and directed
S&F 1100 Volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire,twin core 10 sqmm cable complete all as specified and directed
S&F 1100 Volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire,twin core 16 sqmm cable complete all as specified and directed
S & F submain wiring 2X10 sq mm along with earth wire 1X 10 sq mm FRLS PVC insulated copper conductor, single core in surface drawn in and including casing capping with fixtures. complete all as specified and directed
Dismantling house service brackets, any type,complete all as specified and directed
S&F House service bracket (Hook type) compleate with 3.0 meter long GI pipe 40 mm dia Med grade, two Nos 90 degree bends, MS hooks and stay or guy.complete all as specified and directed
S&F in repair switch socket combination 2 in 1 ,3 pin 5 Amps on the independent board with other switch complete all as specified and directed .
Supply & fix in repair Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal controlled by one switch flush type complete all as specified and directed .
S&F in repair Switch socket combination 2 in 1, 5 A flush type on existing PVC bd complete all as specified and directed by engineer incharge.
S&F in repair Switch socket combination 3 pin , 16 A flush type on existing PVC bd complete all as specified and directed by engineer incharge.
S&F in repair LED 9/10 watt mirror light with neccesary connections and comple all as directed.
M&L Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00mm dia by means of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 30cmx30cmx10cm with one handle for lifting made out of 8mm dia MS bar, watering pipe 20mm bore galvanized iron pipe (medium grade) with MS funnel for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soil complete all other accessories as shown on electrical plate No 3 of MES Sch Pt-I including taking down the existing,all as specified and directed.
M/S ORIENTAL MOTORS COMPANY
M/S MUGHATOLI AYE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .