Loading…
Loading…
Tender Value
₹84.1 L
EMD Value
₹1.7 L
Closing Date
21 Aug 2026, 3:00 pmClosed
Electrical Executive Engineer, EWD 3
EE
EEE, Electrical Work Division 3, BCD, PATNA BIHAR
ELECTRICAL Superintending Engineer, ELECTRIC BUILDING CIRCLE, PATNA
ESE
PROVISION OF LED STREET LIGHT & E/I IN WASHROOMS & DRIVER REST ROOM BEHIND OF BOARD OF REVENUE DEPTT. AND INFRONT OF MAIN BUILDING FROM GATE 1 TO GATE 2 AT OLD SECTT., PATNA
136976
38/2026-27/EBD-3/PATNA/BCD
Open Tender
ELECTRICAL
Patna
• Name and address with contact details of bidder
• PAN
• GST NO.
• AFFIDAVIT DETAILS
• CHARACTER DETAILS OF ALL MEMBERS OF THE FIRM.
• DETAILS OF ELECTRICAL LICENCE
• REGISTRATION DETAILS WITH BCD
ELECTRICAL
PERCENTAGE
L1
1
11 documents required · 11 mandatory
₹10,000
Processing Fee: 5900
₹1.7 L
ESE, ELECTRIC CIRCLE PATNA, PATNA (01-08-2026 03:00 pm) CEE-01, PATNA (03-08-2026 03:00 pm)
25 Jul 2026
25 Jul 2026
22 Aug 2026
27 Jul 2026
21 Aug 2026
27 Jul 2026
1 Aug 2026
BILL OF QUANTITY
Name of Work:- Provision of LED street light & E/I in wash rooms & driver rest room behind of Board of Revenue Deptt., and infront of main Building from Gate No. 1 to Gate No. 2 at Old Sectt., Patna.
SL.No- PARTICULARS QTY RATE UNIT AMOUNT
1 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
2 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 6 414.00 Each 2,484.00
3 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 5 531.00 Each 2,655.00
4 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 75 309.00 Metre 23,175.00
5 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 0.00
1.7.1 2 X 1.5 sq mm + 1 X 1.5 sq mm earth wire 90 201.00 Metre 18,090.00
1.7.4 2 X 6 sq mm + 1 X 6 sq mm earth wire 20 422.00 Metre 8,440.00
6 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 0.00
2.8.6 8 way, Double door 1 2,591.00 Each 2,591.00
7 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 0.00
2.12.1 6/32 amps, single pole 6 237.00 Each 1,422.00
8 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 0.00
2.13.3 40 A to 63 A, Double pole 1 1,198.00 Each 1,198.00
9 1.33 Supplying and fixing 2 pin, 6 amps ceiling rose on the existing junction box / wooden block including connection etc as required. 16 64.00 Each 1,024.00
10 1.34 Supplying and fixing batten/angle holder including connection etc as required. 8 80.00 Each 640.00
11 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required. 6 358.00 Each 2,148.00
12 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 10 521.00 Each 5,210.00
13 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 0.00
14 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. 6 2,482.00 Each 14,892.00
15 2.1 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required. 0.00
16 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixturesetc. As required. 0.00
6.1.6 15 watt LED lamp 8 250.00 Each 2,000.00
17 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 0.00 0.00
18 A/R Earth digging by horizontal directional drilling (HDD) method for LT cable laying. 1180 1,167.00 p/mtr. 1,377,060.00
19 2.4 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. 0.00
20 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 0.00
2.12.8 40 to 63 amps, Tripole pole and neutral 22 2,329.00 Each 51,238.00
21 3.20 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. 18 2,193.00 Metre 39,474.00
22 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed armoured electrical cable with aluminium conductor for working voltage upto 1.1 KV etc as required. 0.00
23 7.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required but excluding sand cushioning and protective covering. 0.00
24 8.12 Supplying and fixing fabricated feeder pillar of cubical construction floor mounted type fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, bus bar chamber, insulator with 40x40x5 mm angle iron stand and complete in all respect etc and must be CPRI approved panel manufactures .( But without RYB LED lamp, Ammeter, Volt Meter, Inter connection copper conductor cable / solid copper strip , switch gears, PCC work etc.) 68 2,261.00 Sq.ft 153,748.00
25 8.13 Supply & fixing panel mounted digital multi meter ( Volt meter & Ammeter) including CT coil and RYB pilot indicator in the existing cubical panel board including drilling holes in the panel board making connections etc. as required. 3 6,536.00 Each 19,608.00
26 8.22 Supply and erection of 6 meter height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 x 220 x 12 mm, small door opening for junction box mounting including 6A 'C' series SP MCB, connector and suitable size foundation bolts with template as required.( but without pole foundation) 0.00
27 8.1 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. 0.00 0.00
8.1.1 Above 4.5 metre and upto 6.5 metre 30 3,771.00 Each 113,130.00
28 5.14 Supplying and fixing following type LED street light with minimum efficiency 100 lumen/ watt in die cast aluminium housing, toughened glass IP66 protection and complete with electronic driver etc. on pole/building including connection, earthing the body etc as required. 0.00
29 9.6 Excavation for cable trench in hard rock not exceeding 1.5 mtr in width and lift upto 1.5 mtrs including getting out the excavation soil and disposal of excatated soil as directed within a lead of 50 Mtrs. 20 758.00 cu.mtr 15,160.00
30 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required. 0.00
31 2.3 Supplying and fixing TPN sheet steel enclosure on surface/ recess along with 63 amps 415 volts, "C" curve TPN MCB complete with connections, testing and commissioning etc. as required. 10 2,431.00 Each 24,310.00
32 3.21 Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required. 8 16,675.00 Set 133,400.00
33 A/R S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd. 32 871.00 P/Kg 27,872.00
34 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 160 144.00 Metre 23,040.00
35 10.3 Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pollars / Lighting DB's for automatic switching ON & OFF of strret lights at sun set & sun rise of twilight (Auto ON, Auto OFF, Auto) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 0.00 0.00
10.3.3 3 output (1 output per phase) and suitable for three phase supply 2 11,194.00 Each 22,388.00
Total Rs. 5,800,058.00
36 8.22 Supply and erection of 6 metre height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting including 6A 'C' series SP MCB, connector, and suitable size foundation bolts with template as required.(but without pole foundation)
37 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 0.00 0.00
38 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required. 0.00
39 8.1 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. 0.00 0.00
8.1.1 Above 4.5 metre and upto 6.5 metre 19 3,771.00 Each 71,649.00
40 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 0.00
41 3.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 4 6,323.00 Set 25,292.00
42 7.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required but excluding sand cushioning and protective covering. 0.00
43 9.13 Providing , laying and fixing of following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required. 0.00
44 11.1 DSR Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 0.00
45 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 0.00
46 7.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required but excluding sand cushioning and protective covering. 0.00
7.3.2 Above 35 sq. mm and upto 95 sq. mm 225 132.00 Meter 29,700.00
47 11.1 DSR Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 0.00
Total Rs. 2,608,404.00
Elect.Executive Engineer,
Elect. Building Div.No.3,
B.C.Deptt.,Patna.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT 38.pdf
NIT • 0.79 MB
NIT 38-2.pdf
NIT • 0.79 MB
NEWSPAPER PUBLICATION NIT 38.pdf
NIT • 0.79 MB
31191_CHECK LIST AND OTHER DOCUMENTS.pdf
NIT • 14.19 MB
Street light & Driver rest room BOQ.xlsx
NIT • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .