| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.5 LAccepted-AOC AT BACHRA P O BACHRA P S PIPARWAR BACHRA 829201 | BACHRA | CHATRA | JHARKHAND | 829201 | L-1 | Accepted-AOC L-1 bidder and offered rate is reasonable and acceptable | |
| 2 | Rejected-Technical AT MOHAN NAGAR PO DAKRA PS KHALARI DISTT RANCHI JHARKHAND 829201 | CHATRA | JHARKHAND | 829201 | - | Rejected-Technical L-3 bidder, document of L-3 bidder not scrutinised as bid of L-1 bidder found accetable technically and financially | |
| 3 | Rejected-Technical C 233 SECTOR 48 NOIDA GAUTAMBUDH NAGAR | NOIDA | GAUTAMBUDH NAGAR | UTTAR PRADESH | - | Rejected-Technical L-2 bidder, document of L-2 bidder not scrutinised as bid of L-1 bidder found accetable technically and financially |
Tender Value
₹4.4 L
EMD Value
₹5,500
Closing Date
26 Jul 2024, 5:00 pmClosed
Staff Officer(EnM)
Office of the GM, Piparwar Area, Post Bachra, Dist Chatra, Jharkhand
Repairing of electrical wiring along with provision of electrical accessories in (1) R.K.M. Union Office (2) J.M.S. Union Office (3) Community Place situated near 4 No. ground and (4) Community Place situated near PNB, Bachra under GM Unit
2024_CCL_312731_1
SO(EnM)/PPR/eNIT/24-25/22
Open Tender
Electrical and Maintenance Works
Fixed-rate
20 days
GM Unit, Piparwar Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,500
28 Jan 2025
16 Jul 2024
27 Jul 2024
16 Jul 2024
26 Jul 2024
16 Jul 2024
16 Jul 2024 - 22 Jul 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper onductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper onductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper onductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and drawing 2 X 6 sq. mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (For Neutral and Body Earthing of Main Distribution Board).
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (For Neutral and Body Earthing of Main Distribution Board).
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (For foundation of Street Light Bracket).
Supplying and fixing 2+2 way, SPN, single door, MCB DB
Supplying and fixing 2+4 way, SPN, single door, MCB DB
Supplying and fixing 10 watt LED Bulkhead Light Fitting.
Supplying and fixing 09 watt LED Bulb.
Supplying and fixing 20 watt LED Tube Light fitting.
Supplying and fixing 2 X 2 Grid Panel Light 42 watts (Module + Driver) having soft light and glare free symmentrical illumination suitable for Grid Ceiling.
Supplying and fixing 12 Watt slim surface mounted LED panel light fitting with inbuilt driver in PC Body having premium diffuser to ensure glare free & even light distribution.
Total impact of GST for the purpose of CTC
MAA BHAGWATI CONSTRUCTION COMPANY
M/S MAA CONSTRUCTION
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .