Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-AOC 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹48.3 L+₹83,945.75 (1.77%)Rejected-Finance R 512 KEGAON BANDHILWADI TAL URAN DISTRICT RAIGAD NAVI MUMBAI 400 702 | RAIGAD | MAHARASHTRA | 400702 | L2 | Rejected-Finance NOT ADMITTED BEING L2 | |
| 3 | L3₹49.5 L+₹2.0 L (4.30%)Rejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L3 | Rejected-Finance NOT ADMITTED BEING L3 | |
| 4 | L4₹50.6 L+₹3.2 L (6.77%)Rejected-Finance | L4 | Rejected-Finance NOT ADMITTED BEING L4 | |
| 5 | L5₹53.7 L+₹6.2 L (13.2%)Rejected-Finance SHARADA SMRITI H NO 840 VINAYAK KATHE ALI KEGAON ROAD URAN NAVI MUMBAI 400702 | RAIGAD | MAHARASHTRA | 400702 | L5 | Rejected-Finance NOT ADMITTED BEING L5 |
Tender Value
₹48.5 L
EMD Value
₹97,100
Closing Date
29 Dec 2023, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
SPECIAL REPAIRS TO BLDG NO P 555 AND ADDITION ALTERATION TO GROUND FLOOR OF BLDG NO P 430 UNDER AGE BRII AT INS TUNIR NAVAL STATION KARANJA
2023_MES_630614_1
8777/E8
Open Tender
Civil Works
Item Rate
180 days
GE NW KARANJA
D and above a i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹97,100
Yes
25 Jan 2024
1 Dec 2023
1 Jan 2024
1 Dec 2023
29 Dec 2023
15 Dec 2023
Amount
Notes : (i) The work consists of 02 jobs as under:- JOB (A) : SO (K)/07/2023-24/LBW JOB (B) : SO(K)/07/2023-24/SPL REP B/R (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. COMMON B&R ITEMS FOR JOB 'A' & 'B' (for job wise details pls refer Appendix -A to BoQ)
NOTES: The Basic Rate quoted Ser item No 1.02 to 4.16 are deemed to include for the following and nothing extra will be paid for these works: 1. Supplying, erecting and use of scaffolding upto required height (max 25 to 30m) with necessary H-frames, pipes, couplers, buckles, bracing, top platform with support railing at top etc. at all levels of building including carriage of the materials to the location, erecting, fixing the scaffolding and dismembering the same after working and taking away the scaffolding materials etc. complete as per direction of Engineer-in-charge. 2. Supplying, erecting & use of temporary bamboo scaffolding around the building as required. The scaffolding is to be secured properly in position by bracings, ties clamps, etc. complete including providing and erecting working platform at all heights as required, including removal after completion of work all as per direction of Engineer-in-Charge. 3. Supply, fixing & use of dust proof netting with all required accessories/ fixing arrangement so as to cover existing installations and arrest the materials generated during repair work in adjoining areas and to prevent damage or nuisance to the existing structure; including proper provision of netting system before start of work, removal after completion of work, carrying out regular cleaning etc. complete all as specified and directed 4. Supporting the structural components temporarily during repair and streghthening works using heavy duty flat-headed steel pipes vertically in plumb, braced horizontally and diagonallay at centre with each other using suitable heavy steel tubes, and resting on wooden blocks to support the structure provisionally during repairs and maintaining them in position for required duration, complete as directed by Engineer-in-charge.
Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debries AS directed for a distance max upto 500m complete all as specified & directed.
Preparation of new or previously untreated plastered surfaces of walls and M & L for applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern over one coat of primer complete all as specified and as directed
Supply only water proofing liquid compoundcomplete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding & disposal of debris at a distance not exceeding 500m complete all as specified and directed.
M&L for joint free glazed ceramic tiles in vertical surface 350mmx250mm x7mm / 450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the joints over & including 10 mm thick rendering or bedding layer in cement mortar 1:6 complete all as specified and directed.
M&L non skid coloured ceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in floors over & including screed bed or bedding layer of morar 15 mm in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
Chipping , removing carefullly concrete work by low impact hammer ,breakar without damaging the structure & cleaning and disposal of debries out side the premises etc. complete all as specified & directed . Note :- Hard concrete should not be removed by force.
Cleaning existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete and M&L for applying two coats of alkaline rust converting primer (Make : FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr. Fixit Rust removal or ShaliRust of STP Ltd or equivalent as approved by GE) on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry complete all as specified and as directed.
M&L for applying two coats of Epoxy based Zinc primer in a span of four hours over the treated rebars and allow to dry for six hours. The application shall be by brush complete all as specified & directed. (Make : Epoxy primer for steel of make / brand - Corroseal-ZR of Krishna Conchem or Dr. Fixit Epoxy zinc primer or equivalent as approved by GE)
Cleaning all loose laitance on the concrete substrate and M&L for applying one coat of epoxy bonding agent on exposed concrete surface to ensure bond between old concrete & new concrete by brush application complete all as specified & directed. Make : Monobond SBR of Krishna Conchem or Dr. Fixit epoxy bonding agent or Shalicrete URP of STP Ltd or equivalent as approved by GE
M&L for applying ready to mix polymer plaster with high quality polymer additives (Polymer plaster) with 4 MPa compressive strength of required thickness over the entire cleaned surfaces including all tools and tackles, etc. in damaged areas in 40 to 50 mm thickness including leveling profliling etc complete all as specified and directed. (Make:- Krishna Conchem, STP or equivalent as approved by GE)
M&L for applying concrete protection coating on finished structural members exposed to atmosphere complete all as specified and directed (Make: IPNET of Krishna Conchem or New Coat from Dr. Fixit or equivalent as approved by GE)
M&L for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes. Works shall be carried out as under complete all as specified and directed:- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the crack with a liberal application of the epoxy putty.
M&L for Injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers (approved make) & migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency ,Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled complete all as specified and directed. (Make : Dr. Fixit Epoxy injection or EPCO KP-HP-250 of M/s Krishna Conchem or Shaligrout EI of STP Ltd or equivalent as approved by GE.)
M&L for Injecting low viscosity (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, Including,Mixing of materialas:Mixing of material components(part a&b) in the required quantities as per manufacturer's instruction by weigh batching.Grouting:Fill the grouting gun with concrete penetrating corrosion inhibitor EPCO-KP-100/Protectsil CIT or Ferogard 903. Maintain desired pressure in the gun by air compressor; maintain the pressureat exit(2 to 3kg/cm2) by monitoring pressure guage at exit.Grout the material through prefixed nozzles in the structural elements@ 100ml per nozzle. Repeat the process for all the nozzles complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed . Note:-Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel.
S&F additional main steel TMT bar or stirrups of designed diameter in various structural elements like column ,beams and foundations including drilling ,bending, welding and fixing the bars with epoxy putty etc. complete all as specified and directed. (Steel provided on the basis of 1% of volume of concrete).
M&L for jacketing around columns with Micro concrete M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete all as specified and directed. Note: (i) Reinforcement shall be measured and paid separately. (ii) Rates including jacketing, formwork and micro concrete)
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 sqm not exceeding 4.0 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) not exceeding 1.5 sqm each , removing from the site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed.
S&F for aluminium door/window/ventilator/partition, made out of extruded powder coated aluminium sections, with sliding or openable shutters including frame & necessary jointing cleats, glazing clips, powder coated aluminium snap beading,screws etc, complete and also including powder coated aluminium fittings such as stainless steel hinges, tower bolts, hooks & eyes, peg stays and handles, concealed star lock for aluminium window, Mortice lock vertical type size 100mm 04 lever for door, rubber beading suitable for fixing 4mm / 5mm thick glass in aluminium window / doors including connected items,with and making good to the disturbed portion with its original specifications incl taking down existing members/frame any position complete all as specified and directed.
S&F aluminium anodised grill of design DG 104 pattern made out of 10mm dia rod fixed with and including standard aluminium frame of F section of size 23.40mmx15.30mm & 1.4mm thick all as per manufactures instructions complete all as specified & directed.
S&F 4mm thick sheet glass ordinary quality black glass colour, white or multicolour like balck etc and glazing with oil putty in square exc 0.5 Sqm in each pane with glazing pins complete all as specified and as directed .
OTHER THAN COMMON B/R ITEMS FOR JOB 'A'
Dismantling of asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified & directed.
S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws etc complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs / Hangars & scafolding & all arrangement.)
S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in valley gutter, ridge hips etc. fixed with self tapping screws etc complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs / Hangars for scafolding as all arrangement.)
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified & directed.
S&F MS flat iron wind ties and stays for gutter including securing with bolts and all necessary drilling bolting or riveting etc. conforming to Fe 410-0 or FE 310-0 Complete all as specified and directed.
Preparation of new untreated steel and iron surfaces of any description not other wise described over 10 centimetre width or girth and M&L for applying two coats of synthetic enamel paint over a coat of red oxide zinc chromium primer complete all as specified and as directed.(Note:- Item rate shall include for any height of Bldgs / Hangars for scafolding as all arrangement.)
Preparation of old painted surfaces of steel any description over 10 cms width or girth and M&L for applying one finishing coat of synthetic enamel paint on steel surfaces complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs / Hangars & scafolding as all arrangement.)
M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) Fe 410-W (Gde E- 250) quality A complete all as specified and directed.
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick below or above ground level un re-inforced complete all as specified and directed. .
M&L plain cement concrete 1:3:6 type C-2 (using 20 mm graded stone aggregate) in plinth protection, 75 mm thick, finished even and smooth without using extra cement, including making joints 12 mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed.
Demolition of pre-cast concrete block masonary built in cement mortar including all quoins, arches, pillars etc. and pre cast concrete articles complete all as specified and directed.
M&L for pre-cast cement concrete block masonry with solid blocks in 10cm in width in type B1 1:2:4 (20mm graded aggrgate) and setting in cement mortar (1:6) complete all as specified and as directed
M&L for rendering 15mm thick on fair faces of brick/concrete surfaces in CM (1:4), finished even and smooth without using extra cement (WPC to be measured and paid separately) complete all as specfified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces of walls in cement mortar 1:6 finished even and smooth (with out using extra cement) complete all as specified.
Preparing newly plastered surface with sand paper and M&L for applying two coats of oil bounded distemper on walls over& including a coat of primer complete all as specified and as directed.
M&L applying 2 mm thick exterior grade wall care putty on wall/ ceiling (multipurpose mixer shall be used for uniform and mixing of putty) complete all as specified and directed
Preparation of plastered or un plastered old decorated surfaces of walls and ceiling by Vacuum based sanding machine and filling cracks/hole by applying wall putty upto 2mm thick (multipurpose mixer will be used for uniform and proper mixing of putty) and M&L for applying two coats of distemper oil emulsion White or coloured by auto roller complete incl removal of nails etc and grinding where necessarycomplete all as specified & directed Note:- Work will be strictly executed by mechinised means/ tools as required for smart periodical services.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs/ Blankets, any thickness, including cover fillets complete all as specified and directed.
S&F 4 mm thick plain asbestos cement board as in false ceiling fixed with timber or mild steel framed work grid and making to good existing frame without disturbing the other false ceiling complete all as specified & directed. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.)
Taking down ceiling boards (fibre, plub, insulaiton boards, blankets any thickness and refixing in ceiling, flat or sloping as per existing pattern with timber or mild steel framed work grid and making to good existing frame without disturbing the other false ceiling omplete all as specified & directed. Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.
M&L for applying two coats of oil bound distemper over a coat of chalk whitening on asbestos cement board false ceiling omplete all as specified & directed. Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.
Taking down existing bitumen felt roof treatment including cement mortar bedding and cleaning the surface and removal outside the MoD land, complete all as specified and as directed. Note :- 1. Taking down earthing strips incl insulators from roof for treatment and re-fixing of same with existing specification in the same position after laid APP membrance including replacement of broken insulators, PVC rawl plus & screws etc are deemed to be inclusive of rate quoted by the contractor. 2. Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work 3. APP work shall be carried out on RCC PENT roof at 12 -15 mtr height (non accessible roof).
Demolition of cement concrete (unreinforced) as in roof or chajja padding of any description and any position not otherwise specifically provided for complete all as specified and directed.
M&L for PCC (1:2:4) type B-1, using 20 mm graded stone aggregates as in padding to roof to maintain the required slope same like as in chajjas, balconies, canopies, desk slabs and in shelves and finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 10mm thick cement plaster in CM (1:3) on roof top and chajja and concrete surface mixed with WPC as per manufacturer’s instructions @ 3% by weight of cement on concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
M&L water proofing treatment of roof consisting as under complete all as specified & directed. :- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) A layer of 4mm thick APP polymeric membrane of weight not less than 4.5 kg/sqm, reinforced with polyester non-woven fabric, duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions.
M&L for appling two coat Bitumen water proofing aluminium heat resistance paint on the roof as per manufacture instructions complete all as specified and directed
OTHER THAN COMMON B/R ITEMS FOR JOB 'B'
M&L for ready mix plaster rendering 10 mm thick in CM 1:4 on fair faces of brick/concrete surfaces , finished even and smooth without using extra cement complete all as specified and directed. Note:- (i) Item rate shall be include any height of Bldgs for scafolding as all arrangement. (ii) WPC paid and measured seprately
M&L ready mix plaster rendering 15 mm thick of brick work or concrete surfaces in CM 1:6 (Water proofing compund paid separtately) finished even and fair surfaces, complete all as specified and directed. Note:- (i) Item rate shall be include any height of Bldgs for scafolding as all arrangement. (ii) WPC paid and measured seprately
M&L for using ready mix plaster rendering 5 mm thick CM 1:3 on ceiling or concrete surfaces, finished even and smooth without using extra cement complete all as specified. Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.
Preparing of plastered surface and prepare the smooth surface with sand paper and M&L for applying two coats royale luxury emulsion interior paint (a luxurious smooth finish white or coloured ) over & including a coat of approved primer on walls or ceiling complete all as specified and as directed.
M&L for highly glossy dark coloured tiles design in vertical surface 1200x600x8-10mm /900x600x8-10mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with & including 3x7-8 mm thick PVC spacer and l 10 mm thick rendering or bedding layer in cement mortar 1:6 complete all as specified and directed.
M&L for 10-12 mm thick glossy finish heavy duty vitrified tiles for parking/ path etc (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and jointed in white/coloured cement to match over and including 10 mm thick screed bed in cement mortar in 1:4, complete all as specified and as directed.
M&L for stone finish kraft cladding wall tiles 15-20mm thick (Square/ rectangular) area of each tiles n exc 0.36 Sqm etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with & including 20 mm thick rendering or bedding layer in cement mortar 1:3 complete all as specified and directed. Note :- Design, colour and pattern as per approved by Engr-in-Charge.
S&F 10 to 12mm thick plaster of paris sheets fix in ceiling with and including grid made out of angles and tees of 1 mm thick G I sheets fixed at not more than 45cm centre to centre in both directions. Grid secured by vertical tie of GI sheet angle at not more than 1.2m centre to centre in both directions. The veritical tie of GI sheet angle shall be fixed with M S dash through fastners of 8 mm dia. The ceiling is to be provided at different profiles like curved, flat, sunk, tapered edge and or raised mouding, the joints shall be filled with plaster of paries, necessary arrangement/cut outs hole for ceiling light as required as required number complete all as directed. Note:- 1. Items rate shall be include any height of bldgs for scaffolding as all arrangement all as specified and directed by Engr-in-Charge. 2. Rate to be included for all kinds of profiles and cut outs required for light fixtures, Speakers, Smoke detector, trap doors and AC grill in the ceiling no extra cost supported with tees, Angles, etc. suitable fixed all complete as per directed The area of these cutouts which is less than 0.6 sqmt for one unit will not be deducted while measuring the ceiling area. 3.The contractor must co-ordinate with electrical & AC contractor for working out various levels for the false ceiling & make the marking on the walls / columns before starting the false ceiling work.
Preparing of new POP/ false ceiling surfaces and M&L for applying two coats royale luxury emulsion interior paint a luxurious smooth finish white or coloured over a coat of approved primer on walls or ceiling complete all as specified and as directed.
Dismantling of stone slabs & tiles of any description or thickness in floor aprons, cills etc laid bedded & pointed in any mortar complete all as specified and directed.
M&L Granite (of any type) work 20mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platform, verticle surfaces and any position in cement mortar 15 mm thick 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl chamfering and rounding of edges where required complete all as specified and directed.
Complete removal of existing treatment by scrapping with mechanical wall sander (mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc including preparation of old decorated surfaces of walls, cornices, asbestos sheet and roof etc and M&L for applying (multipurpose mixer) wall care putty upto 2 mm thick with & including applying two coats royale luxury emulsion interior paint a luxurious smooth finish white or coloured over a coat of approved primer with the help of fully automatic airless spray machine flow speed of max 6 ltr per minutes with a maximum pressure 3300 PSI by the skilled labour over one coat of primer upto 4th storey including necessary scaffolding complete all as specified and directed.. Note:- 1. Work will be strictly executed by mechinised means/ tools as required for smart periodical services. 2. Allow 6-8 hrs to dry the surface for painting of subsequent coats.
OTHER THAN COMMON E/M ITEMS FOR JOB 'B'
Taking down carefully copper /aluminum point wiring ( light,fan,socket or power) complete, with wiring acessories such as bend boards Elbows only, ceiling fittings etc and removing material to store for safe coustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified & directed.
M & L for point wiring with 1.5 sqmm (nominal area) FRLS PVC insulated and sheathed multistranded copper conductor cable ( using colour code as per IS) 1100 volts grade drawn through and including 20mm dia medium grade rigid PVC conduit (ISI marked) concealed on wall surface including concealed sheet steel terminal / CI box with 3 mm thick hylam / masonite sheet top cover with all accessories including 1.5 sqmm size PVC insulated sheathed copper conductor multistranded cable for continuous earth conductor ( using green colour) to common earth and sunken box mconnecting to earth dolly, including casing capping/round pipe at ceiling of suitable size , for one light / Buzzer point controlled by one switch 5 Amp, SP, one way 240 volts complete all as specified & directed. Note :- (I)Necessary cutting and chasing of wall surafce including making good surface deemed to be included in quoted rates.
All as per BOQ Serial item No4.02 above but One 5 pin socket outlet 5 Amps on same board
All as per BOQ Serial item No4.02 above but One 5 pin socket outlet 5 Amps on independent board
All as per BOQ Serial item No4.02 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board.
M&L for wiring for circuits/sub main wiring with FRLS PVC insulate sheathed 2 x 2.5 sqmm stranded copper conductor cable 1100 volts grade medium grade drawn into concealed PVC conduit with 2.5 sqmm PVC insulated green copper cable for continues earth with suitable dia of PVC pipe with all accessories complete all as specified and directed. Note:- Two run of 2.5 Sqmm, One run of 2.5 Sqmm earth wire & one run of PVC coduit shall be measured as one running meter.
S&F single pole, double door MCB DB 240 volts, 200 Amps rated bus bar, 12 way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection open able, including taking out old unsv MCB DB any size/type complete all as specified and directed.
S&F switch 6 amp ,one way complete all as specified and directed.
S&F socket 5/6 amp one way complete all as specified and directed.
S&F switch socket combination 15/16 amp one way complete all as specified and directed.
S&F ceiling rose, 3 phase/PVC/polycarbonate, isolated body, three terminals complete all as specified and directed.
S&F in replacement MCB SP 240 V, 50 Hz, 10 KA conforming to IS 8828 of rating 5 to 32 Amp, 'C' series complete all as specified and directed.
S & F replacement MCB RCBO 40 Amps 240 V 50 Hz 100 mA, confirming to IS 8828 complete all as specified and directed.
M&L for wiring for circuits/sub main wiring with FRLS PVC insulate sheathed 2 x 1.5 sqmm stranded copper conductor cable 1100 volts grade heavy duty drawn into PVC conduit/casing capping on ceiling /wall with 1.5 sqmm PVC insulated green copper cable for continues earth with suitable dia of medium grade PVC pipe with all accessories complete all as specified and directed. Note :-Two run of 1.5 Sqmm, one run of 1.5 Sqmm earth wire & one run of PVC conduit /casing /capping.
Taking down carefully existingTPN/SPN DB & making including connection for new wiring /DB and refix in existing position including nut ,bolt,wire and all connected accessories complete all specified and directed
S&F LED PANEL LIGHT SQUARE TYPE 2X2 fitting 1X 36 w CRCA housing , white powder coated, with polymer diffuser surface / recess mounting in high efficiancy led driver with high power factor , voltage surge protection approx 2 KVA ,IP 56 water & dust proof protection with die cast aluminum housing with heat resistant toughened glass with led tube light fixtures driver holders, suitable size of wire connected etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all specified and directed.
Pheonix Engineers & Contractors
Sagar Electricals
Shri Krishna Trading Corporation
DIGITAL SERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .