| 1 | L1₹49.5 LAccepted-AOC THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹50.5 L+₹97,842.50 (1.98%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹50.6 L+₹1.1 L (2.29%)Rejected-Finance D 235 ADG P CHENNAI | CHENNAI | TAMIL NADU | 600001 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹52.4 L+₹2.9 L (5.95%)Rejected-Finance NO 2 16 KANGAYAMPALAYAM SULFUR PO COIMBATORE 641 401 | COIMBATORE | COIMBATORE | TAMIL NADU | 641401 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹52.7 L+₹3.3 L (6.57%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
26 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVISION OF SANCTIONED WORKS INCLUDING CERTAIN MINOR WORKS AT DIFFERENT LOCATIONS IN DOMESTIC AND TECHNICAL AREAS AT AF STN SULUR
2022_MES_548843_1
8519/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
13 Oct 2022
1 Sept 2022
27 Sept 2022
1 Sept 2022
26 Sept 2022
19 Sept 2022
1 Sept 2022 - 12 Sept 2022
Amount
SCHEDULE A BOQ
Demolition of brick work masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and as directed.
M&L Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete complete all as specified and directed.
M & L for preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer including 3mm thick wall care putty complete all specified and as directed.
M&L for anodised aluminium sliding doors standard JINDAL or equivalent section size 63.5 x 38x1.60mm for frame and section size 47.62x44.45x1.18mm for vertical style section size 47.62x44.45x1.18mm for top and central rail section size 95.25x44.45x1.16mm for bottom rail, section size 19x17.3x0.80mm for glazing clip for shutter including fabrication to required size and partly panelled with 12mm thk both side prelaminated particle board and partly glazed with 4mm thick plain glass including fitting etc including with necessary channel & wheels at top for sliding door , handle, mortise lock heavy duty complete all as specified &directed by Engr-in-charge.
Note for Item No 5:- Aluminium section size specified above if not available in the market next immediate higher size of same make shall be provided without any extra cost to the Govt..
S & F mild steel framed work such as grills grating etc with ends of bars shouldered and / or riveted or forged into spikes framed guard bars, barrel iron doors ladders framed balusters walk ways railing frame work of water tanks and similar work confirming to Fe-410-O or Fe 310-O all as specified and directed.
M&L Preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Note for item No 8 :- (a) All synthetic enamel paint paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained directly from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
Supply and fixing in repair steel window handles with nuts and bolts or with screws including welding/fixing with nuts complete all as specified and directed by Engr-in-charge.
Taking down of aluminum/ Steel windows carefully and re-fixing in same opening including necessary repairing/cleaning/greasing, weldngs, ,Handles, hinges, rubber beadings, clips etc and make the same fully functional complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and supply and fix 4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and area of glass not exc 0.5 sqm each pane complete all as specified and directed.
M&L Welding exc 2,5 cm but n exc 5 cm in length with thickness of metal to be welded n exc 6 mm all as specified and as directed by Engr-in-charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/loose soil complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Soft/loose soil complete all as specified and as directed.
M&L for PCC, type D-2, 1:4:8, using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L Brick work with old size fly ash bricks, straight or curved on plan to any radius, built in cement mortar 1:4 complete all as specified and as directed
M&L Brick work with old size flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed
M & L Damp proof course 20mm thick in CM 1:2 to horizontal or vertical surfaces including necessary formwork complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed
Removing excavated materials not exceeding 50m distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M & L Precast cement concrete type B-1, 1:2:4 using 20mm graded aggregate as in window or door cills, lintels, including chamfers, weatherings, throating etc. and setting in cement mortar 1:4, complete with joints to match complete all as specified and as directed.
M & L Plain cement concrete type B-1, 1:2:4 using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc complete all as specified and as directed.
S&F High strength corrosion resistant TMTsteel bar of grade Fe-500, 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
M&L High strength corrosion resistant TMTsteel bar of grade Fe-500, 5 mm dia to 10 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips in stirrups , spacers and binders etc complete all as specified and directed.
M&L Rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete wall surfaces and finished even and smooth without using extra cement complete all as specified and directed
M&L Rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed
M&L Rendering 5 mm thick in cement mortar 1:4 on fair faces concrete ceiling surfaces and finished even and smooth without using extra cement complete all as specified and directed
M & L APP based polymeric water proofing membrane minimum weighing 4 Kg/Sqm reinforced with polyster non wove fabric laid on primed surface by forced application complete all as specified below:-
Note for item No 36 :- (a) Cleaning the surface with water and using wire brush including removing debris to out side the MoD land and providing following
(b) Rendering 10mm thick in CM 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 3% by weight of cement.
(c) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried.
(d) After the primed surface has dried, apply a coat of hot blown bitumen of grade 85/25 confirming to IS-702 @ 1.2 Kg/Sqm of the surface.
(e) Providing APP modified water proofing as approved by GE weighing not less than 4kg per sqm unrolled over the bituminous coated surface with 100mm over laps, the overlap shall be sealed by flame as per manufacture instructions complete.
(f) Over the APP membrane, apply evenly a tack coat of hot air blown bitumen of grade 85/25 at the rate of 1.20 kg per sqm including cleaning of surface.
(g) Applying a coat of aluminium paint at the rate of 100 gm per sqm as per manufacture instruuction over bituminous layer complete all as directed.
(h) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
Material and labour for Glazed ceramic coloured tiles 450 x 300 mm x 7/8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado including 10mm thick 1:4 backing coat complete all as specified and directed.
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile of size exc 0.06 Sqm but n exc 0.11 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:6) complete all as directed.
Note for item No 45 & 46 :- The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed.
S&F Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails with MS frame covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and as directed.
Supply and fixing 100mm long Butt hinges medium weight cold rolled stainless steel, and fixed complete all as specified and as directed.
S&F 150 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed
S&F 125mm extruded aluminum alloy handles, fabricated type, anodised complete all as specified and as directed.
Supply and fixing 250mm Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminum alloy and fixed complete all as specified and as directed.
M & L Preparing new surfaces of plastered or unplastered wall and applying three coats of white wash complete all as specified and as directed.
M & L Preparing new surfaces of plastered or unplastered ceilling and applying three coats of white wash complete all as specified and as directed.
M & L Preparing new surfaces of plastered or unplastered wall and applying two coats of cement based paint over one coat of primer complete wash complete all as specified and as directed.
M&L Spreading and leveling the soils in layers not exceeding 25 cm thick each layer including watering and well ramming complete all as specified and directed.
M&L Hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 100 mm thick Plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in sub base, sub floor etc complete all as specified and directed.
M&L 25mm thick Plain cement concrete 1:2:4 type-B-1 (using 20 mm graded stone aggregate) as in floors for receiving tiles complete all as specified and as directed.
M&L 50mm thick, plain cement concrete (1:3:6), type C-1 (using 20 mm graded mechanically crushed stone aggregates), as in plinth protection/path/hardstanding including making joints @ 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cemen complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
M&L PVC (SWR) floor trap (dia of outlet 75mm), plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F 75mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed.
S&F 110mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed.
S&F 75mm dia PVC (SWR) junction single, (single T), with access door equal or unequal complete all as specified and as directed.
S&F 110mm dia PVC (SWR) junction single, (single T), with access door equal or unequal complete all as specified and as directed.
S&F 25mm outer dia of pipe PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed.
S&F 25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20oC) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. complete all as specified and directed. Make : SFMC, KPT, Prince
Note for item No 71 :- (a) The unit rate shall include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(b) Wall thickness of pipes shall be all as per IS : 15801
M&L Stop valves, fancy type, chromium plated cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 15mm bore of iron pipe or for union complete all as specified and directed.
S&F Vitreous china urinals bowl type (black or corner wall type),complete including providing and fixing plugs with and including 60 mm long brass scews pointing around urinal back in cement fixing flushing cistern with brackets flush pipe sgrating and union for discharge pipe (Exclusive of fixing supplyy pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
M&L Vitreous china wash down water closet pan (pedestal pattern), white (exluding fixing bolts,flushing cistren and flushpipe) and including seat cover for pedestal pattern complete fixed all as specified and as directed.
S&F Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F PVC valveless syphonic action type flushinsg cistern,10 Ltr capacity low level white with inlet ball valve, float and handle including brackets complete all as specified and directed.
S&F Vitreous China wash basin, white, flat back, size 550 x 400mm excluding ditto but including brackets complete all as specified and directed.
M&L for 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F 32mm bore low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm for WHB complete all as specified and as directed.
M & L 15 mm bore fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 600 mm including complete all as manufactures and all as specified and directed by Engineer- In - charge.
S&F CP Soap dish CAT Part No-ACN-1131N of jaguar or equivalent make of Parriware /Hindware all as specified and as directed.
S&F CP Hand shower (Health Faucet) with 1M Flexible Tube with 8mm bore wall Hook with N.R.V (Back Flow Preventor) complete all as specified and as directed by Engineer-in-Charge Make:- CAT Part No-S. No-ALD CHR-579 Jaquar equivalent in ESSCO/ Kohler
S&F CP 2 way bib cock with wall flange fancy type screwed down screwed for iron pipe 15mm bore CAT Part No-Sl. No-CQT-23041 Jaquar or equivalent in Parryware ,or as per list of makes complete all as specified and as directed by Engineer-in-Charge
S&F Bib taps, cast copper alloy, fancy type, chromium plated with crutch butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-Charge
S&F Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-Charge
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) Cement concrete in surface channels and drains complete all as specified and as directed by Engineer-in-Charge
M&L Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stopped ends complete all as specified and as directed.
M&L Providing precast cement concrete (PCC 1:2:4 type B-1) using 20mm graded stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and as directed
M & L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm dia pipe complete all as specified and as directed
M&L Salt-glazed stoneware drain pipes, 150mm bore, laid in trenches and jointed as specified, complete all as specified and as directed.
M&L Plain cement concrete (1:3:6) type C2 (using 40 mm graded stone aggregate) as concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of size 150 mm bore of pipe, complete all as specified and as directed.
S&F Tubular towel rail brass cromium plated, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm widE with chromium plated bracket guard and railing 60cm long complete all as specified and as directed.
S&F aluminium anodised ventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members and half portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass incl necessary channel frame work, including rubber gasket and aluminium beading complete all as specified and as directed.
M & L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M & L treating the soil along with external perimeter of building using anti termite treatment emulsion @ 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M&L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick machine pressed set jointed and pointed in neat cement slurry and cut and polished using mixture of white & grey cement in equal proportions & pigment, over screed bed or bedding layer of mortar 15mm thick for laying floor fnishes in cement mortar (1:6) complete all as specified and as directed by Engineer-in Charge.
M&L stainless steel work of Gde 304 for stairs (framed) including stringers, treads, landing balusters, hand rail etc., including cleats, brackets etc,. complete all as specified and directed.
Surface dressing not exc 15 cm deep in soft/loose soil all as specified and as directed.
S & F LLDPE septic tank with upflow filter including filter media designed to carry sewage and sludge water and including excavation in any type of soil , PCC 1:4:8 below foundation, filling of aggregates/chips of sizes 20mm graded around tank, vent shaft , connection etc including removal of existing damaged LLDPE septic tank complete for Capacity suitable for 20 users complete all as specified and as directed.
Note for Item No 104 :- The following shall be considered in unit quoted rate. (i) The advanced septic tank to be manufactured by using Roto moulding process as per IS 10141:1982 using superior quality LLDPE as raw material and black colour, In this connection the contractor has to submit certificate from the manufacturer before commencement of work/ at the time of sample approval.
(ii) The advanced septic tank should have flexible inlet and outlet. Tank must have two compartment with provision of sediment collection in Ist compartment and only water should enter in to the 2nd compartment. The 2nd compartment must have polymeric superior quality ball ring media placed in such way it should enter neither Ist compartment nor the outlet pipe. Tank should have heavy duty design to withstand the loaded sand even if it buried few meter below the ground level
(iii) Tank should have designed tree root and other element should not enter into the tank.
(iv) The man cover of the tank should be strong and airtight during usage. The performance of the advanced septic tank must be BOD reduction upto 70% in usage.
(v) The advanced septic tank should be durable, light weight, 100% ECO friendly, rust proof, leak proof and easy to install.
Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil, complete all as specified and as directed.
Excavating over areas, exc 1.5 m but not exc 3 m depth in hard/dense soil, complete all as specified and as directed.
M&L Reinforced Cement Concrete 1:1 1/2:3, type A1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and as directed.
M&L for loose filling with broken bricks of gauge 40 to 80mm in soakage pits, soakage wells complete all as specified and as directed.
M&L form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work: not exceeding 200mm thick (Horizontal or sloping) fair finished flat surfaces of concrete complete all as specified and as directed.
M&L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete complete all as specified and as directed.
Supply and fix RCCB Four pole, residual current rating 300mA, capacity 63 Amp , 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete after checking of complete wiring of the Qtr and carried out any minor rectification in wiring before installation of RCCB including takingdown existing MCB all as specified and directed.
Note for Item No 116 :- Old MCB deposit to E/M store yard.
Supply and fix RCCB Double pole, residual current rating 300mA, capacity 40 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete after checking of complete wiring of the Qtr and carried out any minor rectification in wiring before installation of RCCB including takingdown existing MCB all as specified and directed.
Note for Item No 118 : Old MCB deposit to E/M store yard.
M & L Point Wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade,FRLS cable and incl non metalic PVC Conduit with accessories in wall etc incl modular terminal boxes fabricated with 1.6mm MS/GI sheet concealed to walls etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for the following:-
One light/fan point controlled by one switch
All as per item No. 120 here in before but for One 3 pin socket out 5 amp on the same board
S&F modular switch 1 way 6 Amps, 1 module complete all as specified and as directed.
S&F modular socket outlet multipurpose 2/3 pin 6 amps, 2 module complete all as specified and as directed.
S&F white cover plate with frame, 1 Module complete all as specified and as directed.
S&F white cover plate with frame, 8 Module complete all as specified and as directed.
S&F metal flush box 1/2 module complete all as specified and as directed.
S&F metal flush box 8 module complete all as specified and as directed.
S&F ceiling rose, surface type Bakelite 65x55mm 3 terminal complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed..
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and as directed.
Supply and fixing factory made powder coated distribution board SPN 4 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and directed
S&F MCB SPN 32 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.
Supply and fixing single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600x600x 6mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate,earth work in any type of soil, all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion .
Note for Item 137 :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
(e)Rates inclusive of necessary earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth wire upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard/Dense soil complete all as specified and as directed.
M&L Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :-The rate is deemed to be included for in case sufficient sand not obtained from excavation, the required additional qty obtain from out side MD land as directed.
Supply and lay Bricks common burnt clay old size bricks, sub-class ‘B’ of size 23x11.5 x7.5cm for cable protection cover complete all as specified and as directed..
S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 6 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, complete all as specified and directed. Make : KEI/ Polycab/Havells
Note for Item No 146 :- Excavation and earth work, cable protection cover and sand cushion shall be measured and paid seperately.
M&L Rotational moulded polythene water storage tank of 500 Ltrs capacity cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I complete all as specified and directed.
M & L for Making connection of PP-R distribution branch with PP-R main of following sizes Bore of pipes in 16 to 40 mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed..
S&F 32 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20oC) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. complete all as specified and directed. Make : SFMC, KPT, Prince
Note for item No 150 :- (a) The unit rate shall include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(b) Wall thickness of pipes shall be all as per IS : 15801
S&F 32mm outer dia of pipe PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down old fitting all as specified and directed. Make : Luker cat pat No. LFL 100 or Equivalent of Havells/Wipro.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old fitting all as specified and directed.
M & L Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade,FRLS cable and incl Stove enemelled steel conduit with accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with plastic laminated top cover 2.8mm fixed with cadmium plated iron screws etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for the following:-
One light point/fan/bell point controlled by one switch
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V Make:- M/s Sudhir, Baliga or equivalent
S&F Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specified and directed.
S&F flame proof exhaust fan 300 mm sweep 230 volts, with all accessories fixed on wall/ceiling complete all as specified and directed. Make of sudhir or equivalent, Bajaj, Philips, Baliga
M & L Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade,FRLS cable and incl PVC Casing Capping with accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with modular white plate cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for the following:-
One switch socket outlet 3 pin 5 Amps on independent board
S&F white cover plate with frame, 3 Module complete all as specified and directed.
S&F metal flush box 3 module complete all as specified and directed.
M&L for wall mounted fan 400 mm sweep, power input 55 watt ,1380 RPM, air delivery-75 CMM, single phase 230 volts high performance motor with over heat protection world class styling & finish, facility to control wind & nature mode, aerodynamically designed balanced AS blades including fixing arrangement on wall complete all as specified and directed. Make:- Havells Model -Sameera/ Usha - Maxx Air Super/ Crompton Greeves.
Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed/ Surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. Make:- Luker Model -LKM2240/ Philips/ Havells
Supply and fixing of convetional type garden light fitting with LED bulb of 9 Watt CASTOR Antique fixture with E 27 holder and IP 54 protection inlcuding fixing arrangement with suitable flange base and PCC foundation fixed on ground all as specified and directed. Make /cat part No. Luker cat no.LBF012E27 AG/BK or equivalent make CG/Philips.
Supply and fix Supply only PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed.
Supply and fix non-matallic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, Tee and accessories complete all as specified and as directed. Make : Prince/ Supreme/ Diplast
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed. Make : Luker cat pat No. LFL 100 or Equivalent of Havells/Wipro.
Supply and fixing ALCOR LED flood light, 50 watts RGB colour changing light, 240 Volt, with high quality lenses & reflector, High grade aluminium pressure Die-Cast Housing with toughened glass cover, IP-66 class of protection, complete with control gear and all accessories including necessory PCC foundation for placing of flood light all as specified and directed. Make : Luker cat pat No. LFLR 50 or Equivalent of Havells/Wipro.
S&F cast iron work with articles n.exc 5kg grade FG 150, machined as in gully traps, gratings, manhole covers and similar articles complete all as specified and as directed.
A.GOVINDARAJ
T C KARUNANITHI
KSR AND COMPANY
NAVEEN ENTERPRISES
M/s Shana Constructions
devan enterprises
D.R ASSOCIATES
KRISHNA ENTERPRISES
Neptune Engineers and Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .