The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less ; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Similar nature of work means- Panel Work Outdoor + Indoor Or RRI Work Indoor Or RRI Work Outdoor + Indoor Or EI/SSI Work Indoor Or EI/SSI Work Outdoor + Indoor
Tenderer should submit relevant document regarding completion and execution of any of the work mentioned in para 1.1 above for fulfilling Technical Eligibility Criteria of Similar Nature of Work.
30 conditions · 5 needing a document upload
GST Registration details should be attached
Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017(CGST)/ Integrated Goods and Services Tax Act, 2017(IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also,as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding.Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates.
The successful tenderer who is liable to be registered under GST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/ UTGST/ SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority.
In case the successful tenderer is not liable to be registered under GST/IGST/UTGST/ SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
JPO to prevent the damages of underground utilities :- The contractor shall conform to JOINT PROCEDURE ORDER in connection to procedure for undertaking digging work in vicinity of underground utility of various departments viz Signalling, Telecom and Electrical cables - preventive and post cable cut measures (Ref:- RB Letter No. 2021/Tele/5(2)/3-Part (1) (3425647) dtd. 12.06.2023 ). The biddder is requested to go through the same (copy attached) before quoting their offer. The stipulations of the JOINT PROCEDURE ORDER in connection to procedure for undertaking digging work in vicinity of underground utility of various departments viz Signalling, Telecom and Electrical cables - preventive and post cable cut measures are to be strictly followed till the currency of the contract.
Submission of Drawing and Design:- Drawing clauses as stipulated in PCSTE/SER's letter no. S&T/S/322/Pt. XI dtd. 11.03.2024 (Copy attached as File Name -----> DrawingClauseNIT) is to be adhered by. Prospective bidders are instructed to go through the same before quoting offer.
Provision of DC Track circuit for dual detection (Medha make EI) in various station yards of Kharagpur division.
ST-OT-DC-TRACK-MEDHA-26
ST-OT-DC-TRACK-MEDHA-26
Open
Works - General
15 Months
Paschim Medinipur, West Bengal
₹0
₹31.9 L
30 Jun 2026
8 Jun 2026
16 Jun 2026
83 items across 2 schedules · ₹15,95,80,726.6 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Up to 5 line yard. | Station | 5.00 | 38,738 | 1,93,690 |
| 2 | Up to 6 to 10 line yard. | Station | 3.00 | 58,106 | 1,74,318 |
| 3 | Preparation of Station Working Rules (SWR) in English on the basis of station working rule diagram and gate working rule diagram to be supplied by the contractor. Submission of two draft copy to railway for checking and resubmission of draft in three copies for approval of division after making corrections. Editable Soft copy to be supplied in pen drive. | Set | 8.00 | 13,595 | 1,08,760 |
| 4 | Preparation of Station Working Rules (SWR) in Hindi/Regional Language of that station on the basis of station working rule diagram and gate working rule diagram to be supplied by the contractor. Submission of two draft copy to railway for checking and resubmission of draft in three copies for approval of division after making corrections. Editable Soft copy to be supplied in pen drive. | Set | 8.00 | 13,595 | 1,08,760 |
| 5 | Depth 1.0 meter, Width 0.3 meter. | Kilometre | 17.00 | 79,869 | 13,57,773 |
| 6 | Depth 0.8 meter, Width 0.3 meter. | Kilometre | 14.00 | 70,930 | 9,93,020 |
| 7 | Excavation of trenches including clearing of roots of trees etc. in hard/rocky soil by chiselling up to a depth of 0.5 meter to 0.8 meter and width 0.3 meter at the bottom. Supply & placing split RCC pipes with collar (for jointing pipes) of 100 mm nominal diameter to Spec. No. IS: 10262- 2019 or latest and IS-456-2000 as per SEM Drawing No. 15- D3 (Sheet-2) on sieved soil of 30 mm over cable and concreting(1:2:3) throughout the length upto a layer of 75mm approximately, then back filling the trench by digging and carrying earth from a distance of maximum 30 meters and then ramming of soil after cable laying. This also includes supply of collar and all the materials for concreting by the contractor. | Metre | 800.00 | 589 | 4,71,200 |
| 8 | Excavation of trench in all kinds of soils including soft rocky area and clearing of roots of trees, rocks etc. to a depth of 1 metre and width 0.3 mtr. Track/ Pucca road/Platform crossing/ Level crossing as per SEM Drawing No.15-D5 including supply, transportation and laying of DWC pipes (full) with collar(for jointing pipes) Inner diameter/Outer diameter:103mm/120mm to Specification No.14830 (Part-2):2001 as per SEM Drawing No. 15-D4 and drawing of cable through DWC pipes with collar(for jointing pipes) including back filling and ramming after cable laying as specified in Tech. Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER for S&T Cables or any latest guidelines. This includes repairing and plastering of Platform/Pucca road after cable laying. | Metre | 3840.00 | 691 | 26,53,440 |
| 9 | Cutting and smoothening of inside surface of sizes 80 mm deep and 170 mm width for single/multiple cable chase in concrete or hard rocks or platform or cemented floor. This work includes laying and covering of cable laid in the chase with standard sizes Second class/Fly Ash brick placed and embedded longitudinally and plastered on the top of the bricks and curing 72 hrs. as per Drawing No. Con/SK/T/1 Note: Sundries materials such as Bricks, sand, cement etc., shall be supplied by the contractor at site and to be inspected by Railway Site Engineer before placing in the chase. Note: In case, chase cutting & smoothening are other than prescribed depth & width, Proportionate payment shall be released. | Metre | 750.00 | 256 | 1,92,000 |
| 10 | Horizontal Drilling by using manual pushing method (also called moling) at minimum depth of 1.5 meter below the formation level of earth as per decision of Engineer in charge. Boring diameter should be atleast 110mm. The ground level shall be considered ignoring the bank height of the bank of the road. Note: DWC/HDPE/GI Pipe Supply is covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after laying of the cables into DWC/HDPE/GI pipe. | Metre | 750.00 | 1,023 | 7,67,250 |
| 11 | 1 HDPE pipe | Metre | 800.00 | 1,376 | 11,00,800 |
| 12 | 4 HDPE pipe | Metre | 1000.00 | 1,964 | 19,64,000 |
| 13 | Physical tracing and opening/locating of existing working cables by precision digging for diversion of cables in connection with cable clearance for engineering earth work or for utility shifting without interfering the circuits as per the advice of Railway site engineer. | Metre | 900.00 | 257 | 2,31,300 |
| 14 | Supply, transportation and fixing of Galvanised Iron Pipe (make: TATA/Jindal or better) with threaded collars (for jointing pipe) of 100 mm nominal bore Specification No. IS: 1239, Pt-1, 2004 thickness 3.6 mm medium grade, on bridges, culverts, drain or at places as per instruction of the site Engineer including supply and transportation of materials required for fixing the pipe as per SEM Drawing No.15-D7 on culverts and others including drawing of cables inside the pipe with masonry work at bridge entry and exit of the culvert and curing for 72 hours and pipes are to be clamped at max. 2 meter apart with drilling of holes on the pipe at 10 cm apart for S&T Cables. Note: This also includes dismantling of released GI Pipe/Trough and released material should be returned at concerned store. | Metre | 600.00 | 1,128 | 6,76,800 |
| 15 | Transportation of cables in rolls with or without wooden drums (S&T Cables) from concerned store to the site of works. Note: The unit Drum-KM indicates Drum X length of cable in that drum. It doesn't have any significance over the distance it has to be carried for execution of the work. | Drum-Km | 160.00 | 2,328 | 3,72,480 |
| 16 | Supply & laying of 300 mm X 300 mm pre-cast/cast in -situ RCC cable ducts including top cover as per RDSO drawing No. SDO/S&T/RCC DUCT/1018/1 & 2, dated 29.5.23 or latest. Note- The rate is inclusive of all type of transportation including labour till it is placed into trenches. The laying of cables shall be paid separately fulfilling the laying procedure as per above drawings. | Metre | 6928.00 | 3,503 | 2,42,68,784 |
| 17 | Laying of S&T Cables (Signal/Quad/Power) in the excavated trench to Drawing No. CON/SK/T/5 or latest. Supply and transportation of 'U' clamps, anchoring of cable at every 10 metres interval with 'U' clamp on trench to Drawing No. CSTE/CON /CABLES/81 or latest. Supply, transportation, and placing of cable demarcating led belt to Drawing No. CON/SK/T/6 or latest punched at an interval of 30 metres and wrapped round each cable throughout the cable route and also at every track/Road/ platform crossing as above specified in Technical Circular No. 2/1988 & 01/2010 issued by CSTE/SER or as per latest guidelines and guarding the cables. Collecting empty drums with left over cable and to be returned to the stores of stock holder. Note: Cables will be meggered before & after its laying by contractor under supervision of Railway representative & Contractor will submit their reports. | Kilometre | 160.00 | 20,239 | 32,38,240 |
| 18 | Hiring of JCB/Hydra/Poclain machine in good working condition for earth cutting, levelling, dressing etc., of ground/dismantling structures including disposal of debris through dumpers/Shifting the location box or signal post with foundation etc. with contractor's labour including machine operator, fuel etc. Payment shall be made for actual working hours at site & proportionate payment to be made in case less than hours. Note: Vehicle shall not be more than 3 years old. | Hour | 48.00 | 995 | 47,760 |
| 19 | Removal of normally 13m Rail in the way of cable route trench, signal/location box foundation, track crossing etc. In case of less or more than 13 m, proportionate payment to be done. These obstructions will be removed by the contractor for ensuring proper execution of related works. | Numbers | 400.00 | 117 | 46,800 |
| 20 | Removal of PSC/Wooden/Steel sleeper in the way of cable route trench, signal/location box foundation, track crossing etc. These obstructions will be removed by the contractor for ensuring proper execution of related works. Note: In case of broken sleepers, proportionate payment will be made. | Numbers | 400.00 | 118 | 47,200 |
| 21 | Supply & installation of RFID based Electronic/Pipe route marker for S&T cable with programmable memory for saving the user specific data which can be buried at a depth range 1.5 meter. Make - Stanly/3M or similar Note: 80% payment can be done after supply of item & rest 20% after execution along with final cable route plan including GIS mapping on the web page based/own server. | Numbers | 400.00 | 2,228 | 8,91,200 |
| 22 | Supply of Steel Apparatus case Full height as per Drawing No. SK/Drg./OL/SER /198 or latest with E type lock . E-type lock & their key ward No. will be decided by site engineer as per Specification No. IRS: S-10/78 with Rev. 8 or latest. Supply of Hylam sheets is not covered under this scope. This includes supply of one key & handle for each four Apparatus Case or minimum one. | Numbers | 378.00 | 17,430 | 65,88,540 |
| 23 | Execution of Full Apparatus Case with earth excavation for pit, concrete foundation, surrounding earth work, erection and installation as per Drawing No. Con/SK/T/8 or latest and wiring to be done as per SEM Drawing No.19-D8 or as per direction of site engineer. Supply and fixing of Hylam sheet strip of appropriate size of 3 mm or 6 mm as required with hole for fixing of terminals, fuse blocks, relay and other accessories for signal/track circuit, termination of cable with number embossed ferrules, bunching of cables with PVC tape, proper soldering of cable armour with earth catenary wire, earthing of cable armour as required. Writing & terminal description including Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anticorrosive paint and subsequent two coats of Aluminium paint outside and red oxide inside and lettering etc. This also includes transportation of 25 mm/12mm Hylam sheet for shelf or as required and also includes minor modification in L/Boxes as per site requirement. The contractor shall supply 4 no. of foundation nuts & bolts of size 22 mm dia. x 450 mm long with 2 flat spring washers, with each nut & bolts, sand for filling up cable pit inside the apparatus case including plaster and bolts, nuts, screws, MS Clamps for fixing equipment/cable. Note: - Part payment shall be released after completion of- (i) Foundation- 40%, (ii) Erection - 10%, (iii) Wiring, earthing, testing - 20%, (iv) Painting, writings - 10%, (v) Plastering, sand filling & etc. - 10%, (vi) Commissioning - 10%. | Numbers | 378.00 | 9,147 | 34,57,566 |
| 24 | Supply of 25 mm thick Hylam Sheet of size 955mm x 400mm per specification no. IS 2036 of 1995 or latest. Note:- In case the requirements are different from the above, proportionate payment will be done. | Numbers | 189.00 | 1,198 | 2,26,422 |
| 25 | Supply of 25 mm 6 Way PBT Terminal block as per Specification No. IRS:S- 75/2006 Rev. 2.0 or latest as per IRS Drg. No. SA-23756 Alt-3 or its latest amendments. | Numbers | 900.00 | 322 | 2,89,800 |
| 26 | ND Fuse Cylindrical Type 2 Amp. | Numbers | 800.00 | 48 | 38,400 |
| 27 | ND Fuse Cylindrical Type 4/6 Amp. | Numbers | 800.00 | 55 | 44,000 |
| 28 | ND Fuse Cylindrical Type 10 Amp. | Numbers | 400.00 | 55 | 22,000 |
| 29 | Supply of PBT fuse base block as per Specification No. IRS:S-75/2006 Rev. 2.0 or latest as per IRS drawing No. . SA: 23748 with alt 4 or its latest amendments. | Numbers | 800.00 | 109 | 87,200 |
| 30 | Supply of Polymeric Positive Temperature co-efficient self-Restoring Type fuse (PPTC) of 24-110V, 2-3 Amps capacity Fuse should have an insulating coating of flame retardant epoxy to meet UL-94, V0 requirement working temperature range 40 Degree Celsius to 85 Degree Celsius and leads to be tin platted copper. | Numbers | 1600.00 | 12 | 19,200 |
| 31 | Modification/Upgradation, wiring, validation & alteration of Data Logger/RTU of Digital & Analog Input including NMDL software etc. as per site engineer. The necessary wire from relay to tag block & from tag block to data logger, tag block, terminal, wiring material etc. required for this work to be supplied by contractor. Wire to be procured from RDSO approved firms. | Set | 8.00 | 46,855 | 3,74,840 |
| 32 | Supply of PVC insulated Single core Multi strand Copper conductor of size 1x2.5 sq.mm suitable on Working Voltage upto 750V as per IS: 694: 2010 latest. Wire Colours shall be decided by engineer-in- Charge. | Metre | 3800.00 | 28 | 1,06,400 |
| 33 | Supply of PVC insulated Single core Multi-strands Copper conductor of size 1 x 4 Sq.mm suitable on Working Voltage upto 750V as per IS: 694: 2010 latest. Wire Colours shall be decided by engineer-in-Charge. | Metre | 3800.00 | 40 | 1,52,000 |
| 34 | Supply of PVC Insulated Single core Multistrand, unsheathed with plain annealed/tinned copper conductor 16/0.2 mm diameter as per Specification No. IRS:S-76/89 or latest. Wire Colours shall be decided by engineer-in-Charge. Note: The requirement of plain/tinned copper to be decided by the Engineer in charge. | Kilometre | 40.00 | 7,832 | 3,13,280 |
| 35 | Supply of PVC Insulated single core cable multistrand, unsheathed with plain annealed/tinned copper conductor 3/0.75 mm diameter as per Specification No. IRS:S-76/89 or latest. Wire Colours shall be decided by engineer-in-Charge. Note: The requirement of plain/tinned copper to be decided by the Engineer in charge. | Kilometre | 39.00 | 21,278 | 8,29,842 |
| 36 | Supply of PVC Insulated single core cable multistrand, unsheathed with plain annealed/tinned copper conductor 7/0.75 mm diameter as per Specification No. IRS:S-76/89 or latest. Wire Colours shall be decided by engineer-in-Charge. Note: The requirement of plain/tinned copper to be decided by the Engineer in charge. | Kilometre | 8.00 | 43,745 | 3,49,960 |
| 37 | Supply & transportation of Large SMPS based Integrated Power Supply System (Large IPS scheme 5A-IPS) as per Specification No. RDSO/SPN/165/2023 Ver. 4.0, Amdt.1 or latest and conforming to SE Railway Drawing No. SK/DRG/OL/SER/253, dated 23.01.19 along with 2V/200 AH Low maintenance Lead Acid (LMLA) Battery Bank with complete accessories required for installation of IPS. This also includes supply of i) cables between IPS System to ASM Panel-12 Core x 1.5 sq.mm = 35 meter, ii) System to Battery Bank-16 sq. mm =25 meter. NB: a) In West Goomty, 110V DC bus bar connection for DC-DC Converters "INT" and "EXT" similar to that for East Goomty is also required to be supplied by the firm. b) Cable between Central Relay Room and Goomties will be provided and laid by Railway. Tools & Spare: It is to be supplied as per Annexure I & IV of RDSO specification. | Set | 1.00 | 12,25,273 | 12,25,273 |
| 38 | Transportation, grouting and laddering of Integrated Power Supply (IPS) System including laying & termination of power & signalling cables through ladder on Hylam sheet, fixed on MS angle, by contractor on wall in panel/IPS room of adequate size, painting & lettering. Note: Transportation of batteries, electrolyte, bolts & nuts, screws, trough etc. and other sundry materials required for the above work shall be supplied by the contractor as required. The IPS to be commissioned by the OEM. | Set | 1.00 | 43,881 | 43,881 |
| 39 | Supply of DC-DC converter 110/(24 - 32 V, 10A) as per Specification No. RDSO/SPN/165/2023 Ver. 4.0, Amdt.1 or latest. It should be compatible with existing system as specified by Railway in charge. | Numbers | 48.00 | 17,022 | 8,17,056 |
| 40 | Supply of SMR Module (110 V/20 Amp) as per Specification No. RDSO/SPN/165/2012 Ver. 3.0 or latest. It should be compatible with existing system as specified by Railway in charge. | Numbers | 22.00 | 65,240 | 14,35,280 |
| 41 | Supply of CVT 2 KVA as per Specification No. RDSO/SPN/165/2012 Ver. 3.0 or latest. It should be compatible with existing system as specified by Railway in charge. | Numbers | 22.00 | 82,921 | 18,24,262 |
| 42 | 2 Volt 80AH | Numbers | 1203.00 | 405 | 4,87,215 |
| 43 | Supply, installation and commissioning of Capacity 05 litre Distilled Water Plant (heavy metal type/industrial grade). | Numbers | 8.00 | 6,045 | 48,360 |
| 44 | Supply of Track lead Junction Box (TLJB) made of fibre reinforced plastic as per RDSO drawing No. SA 20101/M (IRS) or SI-10272 (FRP) and as per Specification No. RDSO/SPN/151/1997 or latest with bush & ARA terminals conforming to IRS: S-75/91 or latest. 1 way 60mm PBT terminals, 18" GI pipe of adequate size & MS angles 1500x50x50 mm3 are also to be supplied by the contractor. | Numbers | 1604.00 | 1,430 | 22,93,720 |
| 45 | Supply of 110V AC, 50 Hz, 10A Track Feed Battery Charger as per Specification No. IRS: S-89/2013 Ver.1.0 or latest to charge lead acid cell battery for 1/2/3/4 cells of 80 AH. | Numbers | 401.00 | 3,614 | 14,49,214 |
| 46 | Supply of "B" Type Choke Coil for single rail track circuits on 25 KV 50 Hz AC electrified sections as per Specification No. IRS: S-65/83 (Amdt 3) or latest. | Numbers | 802.00 | 1,938 | 15,54,276 |
| 47 | Supply of disc type fixed Track Feed Resistance (Porcelain Base, Phenolic, Moulding Base) 0-30 Ohm (with tapping at 2, 4, 8 & 16 Ohm) as per RDSO Drawing No. SA-20161-66 or latest and Specification No: IRS:S-23 or latest. | Numbers | 401.00 | 342 | 1,37,142 |
| 48 | Supply of 8 SWG (4.064mm Diameter) GI wire for Track Circuit Bonding or for other application as per Specification No.IS:279/81 or latest. | Kg | 4010.00 | 89 | 3,56,890 |
| 49 | Supply of 30 mm length Channel Pins, single groove for bonding Track Circuiting wires of 7mm dia. for 4mm dia. bond wire to RDSO Drawing No. S-69/M or latest as per Specification No. IRS: S17-75 Rev 3 & IS: 1573-70 or latest. | Numbers | 8020.00 | 2 | 16,040 |
| 50 | Supply of Insulated galvanized flexible stranded wire rope 7x7 construction, 19 mm circumference, Tensile Strength 125- 140 Kg per square mm as per Specification No. IRS:S-3/61 or latest wrapped with Extruded jacket of PVC, thickness 2 mm. Wire colour will be decided by Engineer in charge. | Kg | 6015.00 | 207 | 12,45,105 |
| 51 | Installation, wiring, testing and commissioning of track circuit on Straight Portion of Track (without involving points and crossings) as per Drawing No. SK/DRG/OL/27 or latest and track bonding plan. The work includes drilling of 9/32" hole on Rails, provision of bonding, fixing and painting of Track Lead Junction Boxes, termination of tail cables, termination of Track lead wires, double Jumper wires, Installation & wiring of track feed set (Track Charger, Adjustable Resistance, choke coil, fuses, battery, relays etc.), testing of Glued/Block Joints and also lettering/numbering of track lead junction boxes, block joints and track circuits. This also includes transportation of all materials required for the above installation. Note: Track feed set, bonding wires, TLJB, channel pin, tail cable to be supplied by Railway. | Set | 218.00 | 7,932 | 17,29,176 |
| 52 | Installation, testing and commissioning of track circuit on Point & Crossings as per Drawing No. SK/DRG/OL/27 or latest and track bonding plan. The work includes drilling of 9/32" hole on Rails, provision of bonding, fixing and painting of Track Lead Junction Boxes, termination of tail cables, termination of Track lead wires, double Jumper wires, Installation & wiring of track feed set (Track Charger, Adjustable Resistance, choke coil, fuses, battery, relays etc.), testing of Glued/Block Joints and also lettering/numbering of track lead junction boxes, block joints and track circuits. This also includes transportation of all materials required for the above installation. Note: Track feed set, bonding wires, TLJB, channel pin, tail cable to be supplied by Railway. | Set | 183.00 | 8,108 | 14,83,764 |
| 53 | Supply of Earth Electrode as per Drawing No. 19-D6 of SEM-2021 or latest. GI pipe confirming to IS:1239 or latest of 3.17 mm thickness, minimum 2.5 m long, 50.8 mm diameter, 4.76 mm diameter drilled holes staggered at distance of 152.4 mm. | Set | 378.00 | 2,712 | 10,25,136 |
| 54 | Excavation of earth pit, placing & fixing of Earth electrode with construction of cement enclosure to SEM Drawing No. 19-D6 and drawl of 6 SWG GI/Copper c a b l e from earth electrode to goomties/relay room/cabin/station, etc. and drawl of MS flat 35mm x 6mm for signal post/Location box shall be used as the case may be, including fixing at both ends of the wire/MS flat. This includes transportation of materials. Note: Materials such as charcoals, salt, sal ammoniac, 6 SWG GI wire, copper lugs with Steel bolts & nuts etc. shall be supplied by the contractor. MS flat 35mm x 6mm/Copper cable shall be supplied by Railway. | Numbers | 378.00 | 1,791 | 6,76,998 |
| 55 | Supply of 35 mm x 6 mm thick MS Flat Plate Strip as per IS: 226-1975 or latest for earth connection to Signal post, L/Box etc. | Metre | 1890.00 | 166 | 3,13,740 |
| 56 | Supply of 25mm x 2 mm bare copper strips or 8mm round solid copper in the equipment room. | Metre | 120.00 | 1,258 | 1,50,960 |
| 57 | Routing and termination of 25 mm X 2 mm copper tape/8 mm solid copper round conductor which is to be fixed inside the equipment room with 60 mm, 6KVA insulation studs including supply of insulation studs. The separation of the two successive insulation studs should be 600mm apart. | Metre | 120.00 | 90 | 10,800 |
| 58 | Supply and Installation of class A type Lightening Protection System as per following specification are as under, (i) Lightening arrester technology: Advance Early Steamer Emission. Material: High current discharge stainless steel. International standards: NFC 17- 102 or latest., (ii) Mast material: minimum 2 meter FRP pipe and minimum 3 meter high-grade aluminium/steel. Dimension: 50mm., (iii) Down conduct cable: 50 Sq. mm PVC insulated copper cable having 75m length, (iv) Lightning strike counter: 6 digits counter, Current sensitivity: 1KA to 200 KA, 8/20 & 10/350 micro/Sec. induction Shunt: 0.5 micro. (v) Two (02) No. of maintenance Free Earth with all required accessories as per Specification No. RDSO/SPN/197/ 2016 Ver 1.0 or latest such as copper cables, strips etc. | Set | 6.00 | 1,43,762 | 8,62,572 |
| 59 | Supply of Class C, Type 2 Protection for 24-60V AC/DC supply as per clause No.3.11.2 of Specification No. RDSO/SPN/165/2023 Ver 4.0 or latest. The Class C shall be with pluggable type, with indication and potential free contact. The supplier should submit OEM certificate, KEMA, UL Certificate with the material, for connection between L1-L2, L1-E & L2-E. | Numbers | 401.00 | 893 | 3,58,093 |
| 60 | Supply of Earth Leakage Detector (ELD) - 8 channels as per Specification No. RDSO/SPN/ 256/2002 or latest. | Set | 22.00 | 95,718 | 21,05,796 |
| 61 | Fabrication of stand/rack, installation, testing & commissioning of Earth Leakage Detector (ELD)- 8 channels as per Specification No. RDSO/SPN/ 256/2002 or latest. | Set | 22.00 | 5,947 | 1,30,834 |
| 62 | Up to 200 Routes | Station | 6.00 | 1,16,634 | 6,99,804 |
| 63 | More than 200 Routes | Station | 2.00 | 1,55,512 | 3,11,024 |
| 64 | Up to 200 Route | Station | 6.00 | 61,037 | 3,66,222 |
| 65 | More than 200 Routes | Station | 2.00 | 91,555 | 1,83,110 |
| 66 | Cement Concrete of proportion 1:3:6 (Cement: Sand: Stone chips of 25mm nominal size) for miscellaneous works. It includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture (aggregate will not exceed beyond 3.8 cm). Note: All materials required for foundation are to be supplied by the contractor. | cum | 24.00 | 3,647 | 87,528 |
| 67 | Chase cutting in floor/wall and restoring of floor/wall with plaster for concealing of 50 mm./25mm conduit pipe (covered separately) in floor/wall then painting with matching colour as per existing colour of the floor/wall. | Metre | 400.00 | 68 | 27,200 |
| Schedule total | ₹7,62,61,496 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
IRGCC April 2022
ATTACHMENT
BankMandateForm.pdf
ATTACHMENT
BankGuarantee-converted.pdf
ATTACHMENT
LCform.pdf
ATTACHMENT
EngagementofretiredRlyEmpCertificate.pdf
ATTACHMENT
InspectionMEDHAUpdated.pdf
ATTACHMENT
MedhaEItermsandconditions.pdf
ATTACHMENT
ListofLocationMedha.pdf
ATTACHMENT
AnnexureVIB.pdf
ATTACHMENT
AnnexureVA.pdf
ATTACHMENT
DrawingClauseNIT.pdf
ATTACHMENT
JPOCableCut19FEB2024.pdf
ATTACHMENT
RlyBoardsLetter2021Tele523part13425647.pdf Rly Bd Letter for Digging Work
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
RlyBoardsLetter2021Tele523part13425647.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .