| 1 | L1₹38.5 LAccepted-AOC AT VINDHANE POST DIGHODE TAL PANVEL DIST RAIGAD | RAIGAD | MAHARASHTRA | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹42.1 L+₹3.3 L (8.44%)Rejected-Finance | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹43.8 L+₹5.0 L (12.8%)Rejected-Finance | L3 | Rejected-Finance HIGHER | |
| 4 | L4₹44.4 L+₹5.6 L (14.4%)Rejected-Finance | L4 | Rejected-Finance HIGHER | |
| 5 | L5₹47.8 L+₹8.9 L (23.0%)Rejected-Finance | L5 | Rejected-Finance HIGHER |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
22 Aug 2022, 6:00 pmClosed
GE Amritsar
GE Amritsar PIN-143001
SPECIAL REPAIR AND ADDITION/ALTERATION TO CERTAIN BUILDINGS , PROVN OF BOUNDRY WALL AND BASE FOR GD POST AT OLD AMRITSAR CANTT
2022_MES_540769_1
GE/ASR-34/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE Amritsar
Class D, category ai
8 documents required · 8 mandatory
₹500
GE Amritsar
₹92,000
Yes
12 Dec 2022
25 Jul 2022
23 Aug 2022
25 Jul 2022
22 Aug 2022
9 Aug 2022
Amount
Taking down cement plaster of any description on brick walls, etc including raking out joints, hacking for key scrubbing down with water etc ; Complete all as specified and as directed by the Engineer-In-Charge.
Demolition of brickwork, built in cement mortar including all quoins, arches, pillars, etc. ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:6 ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius, in half brick thick walls and built in CM 1:4 ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:6 finishing even and smooth without using extra cement ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:4 finishing even and smooth without using extra cement ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for rendering 10 mm thick on fair faces of brick work or concrete surfaces on ceiling in CM 1:3 finishing even and smooth without using extra cement ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for applying two coats of whitewash on wall including preperation of newly plastered/old decorated surfaces ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for applying two coats of whitewash on ceiling including preperation of newly plastered/old decorated surfaces ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 Kilogram/10 sqm) including preparation of new surfaces ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for applying plaster of paris putty of 1 mm thickness over new plastered /old plastered surface to prepare the surface even and smooth ; Complete all as specified and as directed by the Engineer-In-Charge.
Dismantling brick tiles or terracing tiles single layer in roof ; Complete all as specified and as directed by the Engineer-In-Charge.
Demolition of cement concrete of any description or in any position and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in flooring Finishing fair and even ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for cleaning of dust & dirt , Removal of all loose existing bituminous material or with chipper & applying heat torch gun to get smooth plain finished surface. Repair all joints & cracks with Highly Elastic bituminous Cold applied Putty-Tarplast- having penetration after setting upto 8mm & confirming to IS 1580:1991. Any annular space between drain pipe and concrete should be filled with mortar admixed with ShaliSBR latex of STP Ltd. Making necessary Gola 75x75 mm with rich cement mortar admixed with ShaliSBR latex of STP Ltd at the interface of horizontal & Vertical junctions ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Slightly damp the surface, avoid standing Water. Prime the surface with Tarfelt LM mixed with potable water in the ratio 1:1 and apply @ 400gm/sqm (as per surface condition). Allow the primer to touch dry in tacky position in open atmosphere. Thenafter apply 1st coat of Tarfelt LM (Liiquid membrane) having elongation 200% confirming to ASTM-C-412 & bridging of 8mm confirming to ASTM-C-836 with tensile strength after 7 days 0.5mm confirmin to ASTM-C-412 with no diluation of water on primed surface is still tacky with consumption of 0.7 Kilogram/sqm. lay Geotex of 45 GSM/Fibre mesh simultaneously and paste it properly with overlap of 50mm. Allow the first coat to dry for 10-12Hrs. Apply 2nd coat of cured first coat with consumption @ 0.7Kilogram/sqm in opposite dierction of first coat by Brush or roller. Sprinkle sand @ 200Gm P/Sqm while the coating is stick to facilitate plastering for protection screed. Allow it to dry for 10-12 hrs . Apply 3rd coat if required as per site reqirement. Providing & Laying minimum 50mm PCC in slope with welded wire mesh 1.5 mm as reinforcement and PCC admixed with Shallplast LW+ of STP Ltd (Integral Waterproofing compound) @200 ml per bag of cement on horizontal surface for mechanical protection over a separation layer of ShallGeo Textile 120 gsm in client Scope ; Complete all as specified and as directed by the Engineer-In-Charge.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in concrete, brickwork or masonry and making good disturbed ground ; Complete all as specified and as directed by the Engineer-In-Charge.
Excavating in post holes (or similar holes) each hole not exceeding 0.5 Cubic Metre, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and remvoing surplus soil to a distance not exceeding 50m and making good surfaces in soft/loose soil complete all as specified & directed by the Engineer-in-Charge.
Material and Labour for Cement concrete type B2, 1:2:4 (40mm graded aggregate) in foundations, filling and mass concrete ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for apply two coats of synthetic enamel paint over a coat of primer including preparation of new steel surfaces ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing 2mm thick Fibre glass reinforced translucent plain sheeting with side lap fixed with coach screw and washer in wall etc ; Complete all as specified and as directed by the Engineer-In-Charge.
Dismantling Fibre glass reinforced translucent plain sheeting in wall covering ; Complete all as specified and as directed by the Engineer-In-Charge.
Dismantling boarding , any description , fixed in any position with screws ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and labour for preparation of newly surface of Ceiling and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing hollow PVC Wall Lining consisting of Plain colour PVC sheet inclusive of solvent cement, PVC frame and all necessary items for fixing at site ; Complete all as specified and as directed by the Engineer-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Vitrified ceramic dark shade tiles 10mm thick (Square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of cement mortar(1:6) 15mm thick for laying floor finishes ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Vitrified ceramic dark shade tiles 10mm thick (Square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm on vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of cement mortar(1:3) 10mm thick for laying on vertical surfaces ; Complete all as specified and as directed by the Engineer-In-Charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.Laid, bedded and pointed in any mortar ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Machine cut Kota stone slab flooring 20-25 mm thick (size not less than 0.5 sqm each) over cement screed base of 15mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Machine cut Kota stone as Skirting/dado 20-25 mm thick (size not less than 0.5 sqm each) over cement screed base of 10mm thick in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour Granite (of any type) work (table rubbed and polished) 20mm thick in steps , jambs, pillars, window cills, cooking plateforms and like in cemnet mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM 1:4 ; Complete all as specified and as directed by the Engineer-In-Charge.
Taking down Chowkats or frames from the opening of size exceeding 1.5 sqm and not eceeding 4 sqm each with shutters ( without taking off shutters from the frames) ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for providing and fixing toughned glass 12mm thick as in hinged door, partitions automatic doors and similar work including cutting to shape, drilling holes and all necessary items as required; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 150mm ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Brass mortice lock, 4 levers, verticle type, size 100 mm, ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Brass mortice lock, 2 levers, verticle type, size 100 mm, ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing 450mm long Brass handles, cast type ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for frosted to toughned glass of any thickness ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Embossed any type of emblem of size 0.45x0.45M on frosted glass door ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Providing and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) (A) Area not exceeding 2.00 sqm each ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Providing and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) (B) Area exceeding 2.00 sqm each ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing 10mm thick toughned glass as in hinged door, partiotions automatic doors and similar work including cutting to shape, drilling holes as required ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Solar control film 50 micron reflective type sticked to glass panes as per instructions of manufacturers ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Wire netting of stainless steel wire 1.4mm dia and size of mesh in 12mm fixed with tinned tacks of stainless steel wire staples ; Complete all as specified and as directed by the Engineer-In-Charge.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing 08mm thick toughned glass as in hinged door, partiotions automatic doors and similar work including cutting to shape, drilling holes as required ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing in reapair 25mm dia stainless steel Curtain rods/ rails with Brass brackets, stops, rollers, finials, 1 pair of Brass decorative knobs for each curtain rod etc ; Complete all as specified and as directed by the Engineer-In-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing 110mm PVC (SWR) bends ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing 18 mm thick PVC board as in shelves for kitchen cabinets etc ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing 5 mm thick PVC board as in back side of for kitchen cabinets etc ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing 18 mm thick PVC shutters one side prelaminated of any shade for kitchen cabinets etc ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and fixing stainless steel rolling drawer pull type suitable for kitchen cabinets with all fixing arrangement area of each drawer n exc 0.30 sqm of vertical face having depth 450mm to 600mm ; Complete all as specified and as directed by the Engineer-In-Charge. Note:- Net area of front finished surface will be measured.
Supply and Fixing 40mm long self closing type hydraulic steel hinges ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing 75 to 80 mm long brass handle ; Complete all as specified and as directed by the Engineer-In-Charge.
Dismantling water tanks and Supply & Fixing rotational moulded polythene water storage tanks of 1000 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-1 including Ball valves high pressure PTMT with epoxy coated Aluminium rod & High density plastic ball screwed for iron pipe and fixed to GI pipe of 20mm bore ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing 20mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing 25mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Finishing walls with textured interior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of interior primer applied @ 2.20Kilogram/10 sqm ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for surface dressing n exc 15 cm deep soft/loose soil ; Complete all as specified and as directed by the Engineer-In-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft soil ; Complete all as specified and as directed by the Engineer-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm ; Complete all as specified and as directed by the Engineer-In-Charge.
Removing excavated material n.exc 50 m and depositing where directed ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existingwork, ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for Cement concrete type D2, 1:4:8 (40 mm graded aggregate) in foundations, filling and mass concrete ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for RCC (Design Mix) M-25 (20mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for RCC(Design Mix) M-25 (20mm graded aggregate) in column, pillars, piers, post and struts ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for RCC (Design Mix) M-25 (20 mm graded aggregate) as in Beams, canatilivers, bressummers, lintels over 1.5m span etc ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for RCC(Design Mix) M-25 (20mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of rough finished surfaces of concrete in foundation and plinth beams; and similar work; vertical or to batter ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Formwork to sides of pillars, posts, struts, piers, columns and stanchions of rough finished surfaces of concrete ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) of fair finished surfaces of concrete ; Complete all as specified and as directed by the Engineer-In-Charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour TMT Mild steel bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour TMT Mild steel bars 5mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips including 10mm dia in stirrups, spacers and binders ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and labour for preparation of newly plastered surface of wall and applying three coats of white wash on ceiling surface ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for 40 mm thk Damp Proof course (1;2;4) on vertical or horizental surface including form work ; Complete all as specified and as directed by the Engineer-In-Charge.
Material and Labour for preparation of newly plastered/unplatered surface of brick wall or concrete surfaces and applying two coats cement base paint over a coat of alkali resistant primer ; Complete all as specified and as directed by the Engineer-In-Charge.
Supply and Fixing Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 ; Complete all as specified and as directed by the Engineer-In-Charge.
Taking down carefully copper/aluminium point wiring light, fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc. removing materials to store for keeping in safe costudy or for taking credit and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
Material & labour for Point wiring for one light point / fan point / bell point / 5 Amp socket outlet point (independent point), controlled by one, one way switch with 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing specifications) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) as in earth wire (using green colour) and connected to common earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge.
All as per item No 92.00 above but one 5 Amp 3 pin socket outlet on the same board with other switches complete.
All as per item No 92.00 above but one 5 Amp 3 pin socket outlet on the Independent board complete.
Material & labour for Point wiring for one 16 Amp socket outlet point (independent point), controlled by one, one way switch with 2.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of 2.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) as in earth wire (using green colour) and connected to common earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge.
Supply & fixing for Modular plate switch 6 amps single pole one way one module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for Modular plate switch 16 amps single pole one way one module with indicator complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for modular plate socket 6 Amps 2 in 1, 5 pin combined shuttered type two module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for modular plate socket 16 Amps 2 in 1, 5 pin combined shuttered type two module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for modular fan regulator step type 120 Watt two module complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for Ceiling rose surface bakelite 65 mm x 50mm, two to three terminals with back plate of 3mm thick bakelite laminated hylem sheet of suitable size ; complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for lamp holder PVC/ polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs of ding dong bell AC 230 V single pole fixed over and including and suitable size sunk cast iron or pressed steel terminal boxes covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs sheet metal enclosure single pole and neutral with two pin and earth plug and socket with & including one single pole 415 volts MCB 20 amps 10KA ; complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB single pole 240 Volts, 50Hz,vrupturing capacity 10 kA, C curve , conforming to IS 8828 of rating 6 to 32 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB double pole 240 Volts, 50Hz,vrupturing capacity 10 kA, C curve , conforming to IS 8828 of rating 40 to 63 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB double pole 240 Volts, 50Hz,vrupturing capacity 10 kA, C curve , conforming to IS 8828 of rating 100 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs factory made Sheet metal Enclouser Distribution Board single pole and neutral , 8 way 240 volt with double door, IP - 43 & IK-09 protection system with having 200 Amps 2 Nos bus bar for neutral bar and earth bus bar, DBs fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCCB Incomer distribution board double door vertical type made out of CRCA MS sheet surface with insulated material like polyester or with epoxy powder coating surface mounting TPN 4 way, 415 volts with copper bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB and IP 43 - IK 09 protection with and including 100 Amp 36 KA 4 pole MCCB with thermal - magnetic setting and Icu = Ics = 100% , including suitable type MCb with blank plate complete all as specified. Note :- The cost of removing old wooden/steel any type box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quoted rate)
Material and labour in repairs submain wiring with two single core PVC insulated multi stranded copper conductor cable FR of size 6 Sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 25 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling, with one 6 Sqmm single core multi stranded copper conductor FR as earth continuity to common earth doly as earth wire (Green colour) complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire with PVC conduit shall be measured and paid as one length.
Material and labour in repairs submain wiring with two single core PVC insulated multi stranded copper conductor cable FR of size 10 Sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 25 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling, with one 10 Sqmm single core multi stranded copper conductor FR as earth continuity to common earth doly as earth wire (Green colour) complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire with PVC conduit shall be measured and paid as one length.
Supply & Fixing in repair wall /ceiling mounting LED 18 Watt tube light fitting complete with all acessories 1x18 Watt LED , with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz, and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection complete all as specified and directed by the Engr-in-Charge.
Supply & Fixing in repairs decorative Gate light fitting made up of high grade unbreakable polycarbonate material suitable for 15Watt LED lamp (B-22 base) with & including one LED bulb 15Watt with accessories ; complete all as specified and directed by the Engr-in-Charge.
Supply & Fixing in repairs energy saving new generation 10 watt LED built up, 6000k bulk head luminaire with opal diffuser light fitting complete with all acessories and connection complete all as specified and directed by the Engr-in-Charge.
Supply & Fixing in repairs of security light fitting LED 25 Watt aluminum pressure dia cast housing with touched glass cover IP-66 protection Including suitable size and accessories complete mounted including connection with & including 3 core PVC insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.5 Sq mm from celing rose to fitting terminal complete all as specified and directed by the Engr-in-Charge.
Material & Labour in repairs earthing complete with galvanised earth plate electrode 600mm X 600mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 metres below ground level) with top edge of earth plate not less than 1.5metres below normal ground level, connected to galvanised earth lead wire 4mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No.3 of MES SSR 2009 , Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge,50mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150mm both ways center to center with suitable lifting handle to cover, earth pit made of PCC 1:3:6 type C-1, GI protection pipe light grade 15 mm bore up to 7.5metres length from earth electrode & engraving of earth marking on nearby building with cement mortar (1:4) plate size 200mm X 150mm X 15mm & painting of earth result etc. including testing ; complete all as specified and directed by the Engineer-in-Charge. Note : - (i) Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately. (ii) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
Supply and fixing in repairs ceiling mounting fitting LED type 36 Watt fitted in 2 X 2 ceiling including PVC wire upto 1.5 mtr from ceiling rose to fitting complete all as specified and directed by Engineer in Charge.
Supply and fixing in repairs 1100 volt grade heavy duty electric power cable 10 sqmm twin core PVC insulated Aluminium solid conductor screwed with inner seathing of PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1metre apart including 4 mm suspension wirewith & including drawn through 25mm dia PVC conduit heavy duty , fixed to walls / pols complete all as specified and directed by Engineer in Charge. complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs post top lantern LED fitting 15 Watt including LED bulb high grade unbreakable polycarbonate suitable for LED bulb including connection with PVC wire ; complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs bell push, Modular type, single pole 5 amps , one module ; complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Decorative Ceiling Fan with LED light , 1400mm sweep BEE Star Rated complete with down rod including fitting and fixture as per site requirement and complete accessories 230 volts single phase 50 Hz AC and connecting up with and including two core PVC insulated PVC sheathed copper conductor cable of required size & length complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repair ceiling mounting Round type LED 18 Watt light fitting complete with all acessories 1x18 Watt LED , with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz, and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection complete all as specified and directed by the Engr-in-Charge.
Supply and fixing for Storage water heater (Geyser) of 25 litres capacity 230V AC, 50HZ having element of 2 KW of COPPER/INCOLOY alloy , Rust proof outer body, high density PUF insulation, BEE 5 Star Rated , Inner tank of stainless steel 304 which can sustain pressure of minimum 8 Bar working pressure and having multifunction safety valve, making electric and water connection complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing Supply, installation, testing and commissioning of 2.00 ton Capacity , Air Conditioner, split type ( Indoor & outdoor unit complete with remote ), single phase, rotary compressor and condenser coil of copper having cooling capacity 4500 K Cal per hour , BEE 5 star rated, refregirent type R410A/R32 with cordless remote control unit , including copper pipe , fitting and fixture & complete accessories as per site requirement complete all as specified and directed by the Engineer in Charge.
Supply, Laying, Testing and Commissioning in trenches or drawn through pipe or fixed on wall / poles LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 70 Sqmm 3.5 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor , including disconnecting, dismantling and taking down/out old unserviceable cable ; complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in trenches or drawn through pipe or fixed on wall / poles LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 10 Sqmm 4 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor , including disconnecting, dismantling and taking down/out old unserviceable cable ; complete all as specified and directed by Engineer-in-Charge.
Supply ,Installing, commissioning and testing LT panel board, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 3.15 mm thick CRCA sheet , and inner partition made of 2mm thick CRCA sheet and angle iron frame of size 50mm x 50mm x 5mm inside depth not less than 50 cm and size suitable to accommodate the following & including following accessories, with insulated alluminium busbar 600amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories complete , and embedded in PCC plinth made of PCC 1:4:8 type D1 , including dismantling and taking down the old unserviceable LT Panel complete all as specified and directed by the Engineer in Charge :- (a) MCCB 250 Amp four pole with breaking Cap 25 KA-01 No (Incoming) (b) MCCB TPN 160 Amps with breaking cap 10KA - 03 Nos (Out Going) (c) MCCB 100 Amps (TP) with breaking capacity 25 KA -02 Nos (Out Going) (d) Volt Meter (digital Type (0 T0 600 Volts)-01 No (e ) Ammeter (digital type) with Cts 0-300Amps)-01 No (f) Phase indication lamps LED type with holder-01 Set(Set of Three) Notes :- (i) The Panel Shall be of approved CPRI make. (ii) The rates Quoted shall include for earth work and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board.
Supply & fixing in repairs on load change over switch of cap 200 Amps complete all as specified and directed by Engineer-in-Charge.
RAJ KAMAL BUILDERS
ESS KAY BUILDER
GEE EMM ASSOCIATES
m/s. gopal krishan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .