Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC 0 MATADIN KAKRAHI KAKRAHI BHARTHANA ETAWA ETAWAH UTTAR PRADESH 206242 | ETAWAH | UTTAR PRADESH | 206242 | L1 | Accepted-AOC Evaluated L1 Bidder | |
| 2 | L2₹17.4 L+₹1.3 L (8.16%)Rejected-Finance | L2 | Rejected-Finance Evaluated L2 Bidder | |
| 3 | L3₹18.0 L+₹1.9 L (11.9%)Rejected-Finance 1 VILLAGE SIRDI BHARMOUR BHARMOUR CHAMBA HIMACHAL PRADESH 176315 | CHAMBA | HIMACHAL PRADESH | 176315 | L3 | Rejected-Finance Evaluated L3 Bidder | |
| 4 | L4₹18.3 L+₹2.2 L (13.8%)Rejected-Finance C O ANU REFRIGERATION WORKS GANDHI CHOWK PATHANKOT GANDHI CHOWK PATHANAKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Evaluated L4 Bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Techno-commercially non-Responsive |
Tender Value
Refer Docs
Closing Date
3 May 2021, 3:00 pmClosed
Sr. Manager (Contracts)
NHPC Ltd., Baira Siul Power Station, Surangani
Electrical Wiring of Executive Field Hostel proposed to be constructed at Surangani
2021_NHPC_625197_1
NH/BSPS/CC/RMU/51/2021-22/06
Open Tender
Electrical Works
Works
450 days
Surangani
Please refer Tender documents.
8 documents required · 8 mandatory
₹590
Yes
NHPC Ltd., Baira Siul Power Station, Surangani
Exempted
23 Jul 2021
3 Apr 2021
7 May 2021
3 Apr 2021
3 May 2021
3 Apr 2021
Amount
“Electrical Wiring of Executive Field Hostel proposed to be constructed at Surangani”
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 Sq mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq mm HRFRLS / PVC insulated single core (flexible) copper conductor cable as required. Group B Point
Wiring for Twin control light point with 1.5 Sq mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with 2-way,5/6 amps piano type switch and earthling the light point with 1.5 Sq mm HRFRLS / PVC insulated single core (flexible) copper conductor cable as required. Group B Point
Wiring for Power plug with 2x4 Sq.mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit, along with 1 No. 4 sq.mm HRFRLS / PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit /sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit, along with 1 No. HRFRLS / PVC insulated single core copper conductor cable of same for earthing as required:2x2.5 sq.mm
Wiring for circuit /sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit, along with 1 No. HRFRLS / PVC insulated single core copper conductor cable of same for earthing as required:2x10 sq.mm
S/F Modular G.I. Boxes with cover plate: Supplying & fixing of G.I. Modular boxes of the following sizes along with modular base and cover plate for modular switches in recess as required: 4 modules (140 mm x 78 mm x 50 mm)
S/F Modular G.I. Boxes with cover plate: Supplying & fixing of G.I. Modular boxes of the following sizes along with modular base and cover plate for modular switches in recess as required: 6 modules (205 mm x 78 mm x 50 mm)
S/F Modular G.I. Boxes with cover plate: Supplying & fixing of G.I. Modular boxes of the following sizes along with modular base and cover plate for modular switches in recess as required: 8 modules (120 mm x 135 mm x 60 mm)
S/F Modular G.I. Boxes with cover plate: Supplying & fixing of G.I. Modular boxes of the following sizes along with modular base and cover plate for modular switches in recess as required: 12 modules (205 mm x 135 mm x 60 mm)
Supplying and fixing following rating Modular switch / socket on the existing switch box / cover plate including connections etc. as required:S.P. 5/6 amps one way switch, Modular Switch
Supplying and fixing following rating Modular switch / socket on the existing switch box / cover plate including connections etc. as required:5 pin, 5/6 amps modular socket outlet
Supplying and fixing following rating Modular switch / socket on the existing switch box / cover plate including connections etc. as required:S.P. 15/16 amps one way modular switch
Supplying and fixing following rating Modular switch / socket on the existing switch box / cover plate including connections etc. as required:6 pin, 15/16 amps modular socket outlet
Supplying and fixing following rating Modular switch / socket on the existing switch box / cover plate including connections etc. as required: TV Socket outlet, modular
Supplying and fixing following rating Modular switch / socket on the existing switch box / cover plate including connections etc. as required: Telephone Socket outlet, modular
Supplying and fixing of following sizes of PVC Conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following way, single pole and neutral sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, wire-set ,neutral link, earth bar, din bar, detachable gland plate, blanking plate, cable, identification labels inter-connections, phosphatized and powder painted, including earthling etc. as required:-(Double door-16 way)
Supplying and fixing Ding-Dong \ Electronic musical beel, suitable for D.C / A.C. single phase, 230 volts complete as required.
Supplying and erection of 6 amps to 32 amps, rating, 10 KA breaking capacity,240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required:-(Single pole, Cat-B)
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity,240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required:-(Double pole, Cat-B)
Installation, testing and commissioning of pre-wired, fluorescent light fitting / compact fluorescent fitting of all types complete with all accessories and tubes etc, directly on ceiling/ wall including connections with 16/0.20 mm twin twisted flexible, cotton breaded, copper cable and earthling etc as required. (22 W LED tube light)
Supply of 22 Watt LED tube light
Installation, testing and commissioning of pre-wired, fluorescent light fitting / compact fluorescent fitting of all types complete with all accessories and tubes etc, directly on ceiling/ wall including connections with 16/0.20 mm twin twisted flexible, cotton breaded, copper cable and earthling etc as required. (18 W LED tube light)
Supply of 18 Watt recessed LED light
Supplying & drawing co-axial TV cable, RG-6 grade, 0.7mm (75 Ohms) copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.
Supplying and drawing following pair of Fire retardent,PVC insulated 0.5 sq.mm (FR-flexible) copper conductor,flat,unarmoured,telephone cable in the existing surface/recessed, steel/PVC conduit as required. - 4 Pairs
Providing , Installation ,testing & commissioning of ceiling fan with regulator, including wiring , the down rods of standard length (up to 30cm) with 16/0.20 mm twin twisted flexible , cotton braided copper cable , including providing & fixing phenolic laminated sheet , cover on the fan box and earthling etc as required. (Ceiling fan 1400mm sweep, category-A)
Providing & Installation of exhaust fan of following sizes in the existing opening , including making the hole to suit the size of the above Fan, making good the damages, connections, testing and commissioning etc as required. (Exhaust fan, Light duty, (Domestic) 300 mm sweep)
Providing & Installation of Stationary storage type electric Water Heater (Geyser) of various sizes by means of expansion bolts with nut and washers, including embedding of expansion bolts in the wall, providing and fixing of Non-return valve, dead weight safety valve, 02 Nos CP connection rods 18 " long making good the damages, electrical connections, safety valve connections, testing and commissioning etc as required. 35 Ltrs capacity water Heater, Cat-A
Installation of stationary storage type electric water heater (geyser) of various sizes by means of expansion bolts with nuts and washers, including embedding of expansion bolts in the wall, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required. (Water heater)
Water heater (Instant) 6 ltr
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubical panel, making connections etc. as required 125 Amp - 16KA
Earthling with copper earth plate 600 mm x 600 mm x 3 mm thick, including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) complete as required.
Extra for using salt and charcoal for G.I. Or copper plate earth electrode complete as required
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for earth connections etc., as required.
Providing and laying earth connections from earth electrode with 6 SWG (4 mm dia) copper wire in 15 mm dia. G.I. Pipe from earth electrode etc. as required
ANIL THAKUR
sonakshi buildtech pvt ltd
Anu Refrigeration works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .