Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 CrAccepted-AOC | L1 | Accepted-AOC Lowest bidders | |
| 2 | L2₹21.5 Cr+₹1.1 Cr (5.40%)Rejected-Finance 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹23.8 Cr+₹3.4 Cr (16.8%)Rejected-Finance UTARLAI KAWAS BARMER RAJASTHAN 344 001 | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹12.8 Cr
EMD Value
₹9.6 L
Closing Date
24 Feb 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVN OF DEFICIENT MD ACCN FOR OFFICERS AT HQ EAC (U) AF UNDER GE (I) (AF) SHILLONG
2024_MES_650025_3
88988/SHL/E8
Open Tender
Civil Works
Lump-sum
700 days
GE(I)(AF) SHILLONG
As per NIT Conditions
8 documents required · 8 mandatory
₹3,000
GE(I)(AF) SHILLONG
₹9.6 L
Yes
31 Jul 2025
24 Dec 2024
3 Mar 2025
24 Dec 2024
24 Feb 2025
10 Feb 2025
Amount
NOTE (Applicable for all Parts/ Items):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
SCHEDULE "A" Part - I (BUILDINGS/STRUCTURES) (Note: This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.)
Construction of One Block of 12 Dus for Offrs (Sqn Ldr and above) in stilt +4 storey configuration with vehicle parking/garages in ground floor, RCC tank on terrace for fire fighting capacity of 25000 litres, RCC framed structure complete all as specified and as shown on drawings here-in after.
Construction of Garbage Bin complete all as specified and as shown on drawings.
SCHEDULE 'A' PART- II SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- III (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- V (ROADS) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- VI ( SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- IX (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- X (LIFT) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- XI (RETAINING WALL) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- XII (FENCING AND STEEL GATE) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- XIII (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- XIV (FIRE FIGHTING AND FIRE ALARM SYSTEM) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
S & F modular metal flush box with modular white cover plate with frame, 8 module complete all as specified and directed .
S & F modular metal flush box with modular white cover plate with frame, 6 module complete all as specified and directed .
S & F modular metal flush box with modular white cover plate with frame, 3 module complete all as specified and directed .
S & F modular metal flush box with modular white cover plate with frame, 1 module complete all as specified and directed .
S & F LED lamp 10 watt fixed to holder complete all as specified and directed.
S&F modular TV coaxial cable socket with modular plate and switch box including connections including modular plate etc as required complete all as specified and directed.
S&F modular Telephone socket with modular plate and switch box including connections including modular plate etc as required complete all as specified and directed.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required complete all as specified and directed.
Supplying and drawing Two pair 0.4 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required complete all as specified and directed.
S&F LED light fittings 4 feet, 1 x 20 W, 220 V AC decorative box type with driver including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED light fittings with high output diffuser 2 feet, 1 x 10 W, 220 V AC decorative type with driver including LED lamp, connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED security light fittings, 1 x 35 watt with integral reflector made of aluminium alloy LM6 with LED driver including LED lamp, surge protector and all accessories, pre-wired, including bracket made of 40mm bore GI tubing, medium grade of 1.5m long, bent to shape with MS clamp, including connecting up with three core PVC insulated sheathed copper conductor cable of suitable size complete all as specified and directed.
S & F LED lights fitting, 1x 9W/10W, bulkhead luminaires, 220V, AC LED light with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F LED wall bracket decorative light fittings,1x 9W/10W, polycarbonate body including LED light with driver, holder and LED Bulb of B22 base and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F modular type MCB protected socket box having metal flush box with PVC cover plate with one single pole MCB 20 Amps and one 20 Amp 3 pin power socket with 3 pin 20 Amp plug Top complete all as specified and as specified.
S&F Exhaust fan, heavy duty, of size 300 mm sweep, metallic steel body, single phase, 900/950RPM, including suitable metallic louver, blades, frame and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete in all respect all as specified and directed.
S&F Exhaust fan sturdy plastic body of size 300 mm sweep, metallic steel body, single phase, 1200RPM, heavy duty typ with suitable plastic louver, blades, frame and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete in all respect all as specified and directed.
S&F electric water heater storage type steel body with stainless steel inner tank and heating element upto 1.5/2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, including PVC connection pipe for hot/ cold water to existing water lines,necessary fixing arrangement by using 50 X 5 mm MS plate and writing MES No and paste the instruction sheet of Do’s and DO NOT complete all as specified and as directed.
S&F concealed sub main distribution box, double door, vertical type, TPN, 415V, 12 way, IP 43 suitable for MCCB of 125 Amps, 4P, 16 kA as incomer and MCCB TP 40/63 Amp as outgoing complete with suitable bus bar, neutral link, earth link complete all as specified and directed. Note : (i) MCCB/MCBs shall be measured and paid separately (ii) Blank space shall be covered with blank plates and cost for the same shall be deemed to be included in the quoted rate.
S&F concealed sub main distribution box, double door, vertical type, TPN, 415V, 8 way, IP 43 suitable for MCCB of 100 Amps, 4P, 16 kA as incomer and MCCB TP 40/63 Amp as outgoing complete with suitable bus bar, neutral link, earth link complete all as specified and directed. Note : (i) MCCB/MCBs shall be measured and paid separately (ii) Blank space shall be covered with blank plates and cost for the same shall be deemed to be included in the quoted rate.
S & F Smart RF/Cellelur/Hybrid (RF + Celluler) Three phase AC Meter Temper Proof, static meter of class 1.00, 415 V, 50 Hz, 10A-60A as per IS -16444 and relevant IEC standards with inbuilt Radio Frequency communication facility with self healing mesh network with default and no demand display, billing data generation facility, anti-temper features, Microprocessor and LED/LCD based circuitary including SMC meter box of minimum size 250 x 250 x 155mm or as suitable for 3 phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and as directed. Meter shall support sending the following data :- (i) 15/30 min instantaneous data for volgtage, current, power, cumulative energy and frequency, monthly billing survey for cumulative energy and max demand to software meter shall have connected/disconnected functionally operateable from mdm/billing software and prepaid features shall be MDM/Billing end as per prevalent IS. Note :- Only meter shall be fixed in this scope of work and meter shall be confirming to IS-16444)
Supply, Fixing and Installation of wall mounted Electric Kitchen Chimney of size 90cm, metal body, compact design suction 1250 m3/hr, Filter less and dry heat clean technology.matt black finish, hassle free and dry heat auto clean technology, thermostatic touch control panel with three speed gesture motion, black metal oil collector, motor with copper winding, black glass clad hood with LED insignia, front panel with black glass, energy saving MED light, metal blower plus metal housing, Noise level- 58 dBA (maximum), 5 years warranty complete with fixing system for smooth running of chimney complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (light grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @150 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (medium grade) testing on completion complete all as specified and directed. [Note : (a) Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate.
S&F 15 mm bore angle cock, cast copper alloy, chromium plated with long shank and cup, fency type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed.
S&F 15 mm bore shower rose, cast copper alloy, chromoum plate with long shank and cup, fency type of length 300mm (minimum) complete all as specified and directed.
M & L for LLDPE septic tank of capacity 5000 litres, with necessary strong basement with concrete as per manufacturer's instructions , complete all as specified and as directed. (Note : Cost of basement including excavation in any type of soil , returning filling in and removal of surplus soil etc shall deemed to be included in the unit rate)
Construction of Soakage well exc. In ordinary soil , foundation in PCC (1:3:6) type C2 (using 40mm graded stone aggregate), wells of honey combed masonry with top ring of RCC M-25 (design mix) using 20mm graded stone aggregate, including intercepting chamber, screen chamber made of brick work in CM 1:4, RCC cover slab in M-25 /SFRC cover, interconnecting pipes of RCC/DWC complete, filled with brick bats, size 1.2m dia x 3.0m deep (effective depth) complete all as specified and as shown on drawings.
M & L for cement concrete (1:3:6) type C-2 (40 mm graded broken aggregate) as in concrete bed to drain pipes for 450 mm bore pipes including packing under and houching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M&L for construction of brick masonry valve pit chamber of internal dimension 900 x 900 x 900 mm depth with sub class 'B', old size, in CM (1:6) and 10mm thick plastering in CM (1:4) ,PCC (1:4:8) type D2 (using 40mm graded broken stone aggregate ) as in foundation lean concrete ,PCC (1:3:6) type C1 (using 20mm graded broken stone aggregate) as in bedding and copping MS frame with 50x50x6mm angle iron 5mm thick MS sheet cover plate with locking system ,hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preperation of surface ,three coats of white wash on plastered suface (exposed to view ) including necessary excavation in soft loose ,soil ,returning filling in and removal of surplus soil to a distance not excedding 50 m complete all as specified and directed.
Supply, installation, testing and commissioning of step down outdoor type copper wound, Oil cooled transformer of capacity 160 KVA (Level-2) complete with standard, fitting HT 11KV, 3 Phase, LT 433 volts, 3 phase 4 wire (Dyn11) with off load Tap changer with range +7.5 to -7.5% in steps of 2.5% on HT side to vary secondary voltage all as per IS 1180 ,complete all as specified and as directed. Technical Details : (a) No load Voltage Ratio (Normal Tap) - 11000/433 V (b) Number of phases : Three (c) Frequency : 50 Hz (d) Type of Cooling : ONAN (e) Winding connections : The primary winding (HV) shall be connected in delta and secondary winding ( LV) shall be connected in star. (f) Vector Group : Windings shall be connected as per Vector symbol : Dyn11 (g) Neutral Earthing : The neutral point of Secondary (LV) winding shall be brought out to a separate insulated terminal and shall be solidly earthed. (h) Off Load Tap Changer of the transformer : Voltage tapping range on H.V. side will be (+7.5%) to (-7.5%) insteps of 2.5%. The tap changing switch shall be located in a convenient position so that it can be operated from ground level. The switch handle shall be provided with a locking arrangement along with tap position, enabling the switch to be locked in position. The tap position marking shall be increased in clockwise direction and there shall be a back stopper in between tap position 1(+7.5%) & 7(-7.5%). (j) The percentage impedance at 75 °C & 50 Hz refer to the (normal) principal Tapping shall be as per BIS BEE rating. (k) Losses : Minimum losses as per BIS BEE rating.
Serial Item No. 15.32 (Contd....) Structural Details : The transformer shall be comprising of the following items :- (a) Transformer tank shall be constructed robust rectangular shape with wall thickness as per IS 1180. (b) Radiators – press fin type. (c) Externally hand operated off-circuit Tap Changer switch with position indicator and locking device. (d) Conservator with Oil gauge, filling Hole with plug and drain hole with plug. (e) Undercarriage with four plain rollers. (f) Oil filling hole cum air release plug. (g) Drain Valve cum sampling valve. (h) Filter valve with Plug (j) Lifting Lugs for Transformers. (k) Lifting lugs for Lid.(l) Earthing Terminals.(m) Thermometer Pocket (n) Silica gel Breather assembly (o) Inspection Cover. (p) Explosion Vent. (q) 6 inches Dial type temperature indicator with Metal Guard (r) HT and LT Bushing (s) Cable box at LT side.(t) Rating Plate and Diagram Plate. NOTE :- (a) All the arrangements for loading unloading and placement on platform shall be made by the contractor. (b) The contractor/manufacturer shall furnish original certificate (paid voucher and test certificate) of the CRGO manufacturer. (c) The manufacturer /contractor shall furnish the diameter of LV and HV copper winding and its total resistance. The stray losses shall be specified in percentage terms. (d) The contractor shall get the approval of GE for the make of the transformer they plan to procure.
Serial Item No. 15.32 & 15.33(Contd....) (e) Prior to manufacturing the general arrangement drawing design details of the transformer shall be got approved by GE. (f) Transformer shall be dispatch only after inspection clearance by inspecting officer detailed bu Accepting Officer. (g) Testing of transformer at various load factors shall be done at site with the help of OEM technician till achieving satisfactory result at site in front of Engineer-in-Charge. (h) All the HT/LT UG cables shall be properly connected it at their respective terminals without any any contact before testing. (j) Transformer shall be provided with robust lifting hook so that it can be easily lifted for transportation and shifting. (k) Transformer shall be mounted on channel and wheel with stopper pin so it can be moved easily. (l) Necessary foundation with plinth shall be provided as per manufacturer's recommendation, quoted rate shall be deemed to be included accordingly. (m) First time Transformer Oil filling shall be deemed to be included in the quoted rate
Supply, installation, testing & commissioning of 11 KV of rating 630 Amps RMU unit outdoor type (IP-54) protection duly painted ,SF-6 gas insulated RMU (Ring main unit) Three way comprising of Two numbers SF6 insulated load break switch as incoming and one number SF6 Circuit Breaker as outgoing inside SF6 gas filled stainless steel (nonferrous and nonmagnetic grade) tank having IP-67 degree of protection with painting as per manufacturer's specification & leak rate of SF-6 gas less than 0.1% , gas refillable at site/factory. RMU shall be provided with Copper Bus bar, one number fault passage indicator, mechanism for interlocking arrangements for powered relay complete with all accessories as under. RMU type installation Outdoor type, arc proof as per IEC: 62271-200 for design, Manufacturing and testing. The RMU shall have the following features/specifications :- (i) Rated Voltage upto -12 KV. (ii) Rated power frequency withstand voltage -28KV. (iii) Rated lightning impulse withstand voltage -shall be minimum 95 KVP. (iv) Rated current for ring main feeder -630A. (v) Rated current for VCB feeder- 630A. (vi) Rated short-time current-21 KA/3 Sec. (vii) Rated short making current -52.5 KA. (viii) Ambient temperature- (-1 degree Celsius to +45 degree Celsius), (ix) Degree of protection against accidental contact and ingress of foreign objects shall be assured as under :- (aa) Main electric circuits : IP-67, (ab) Fuse compartment IP3X, (ac) Operating mechanism -IPXC, (ad) Cable connection compartment -IP2XC with site replaceable cable bushing.
Supply, laying in trenches sub class 'B' bricks locally available of 230 x 115 x 75mm for cable protection complete all as specified and directed.
M&L for Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 20×3mm copper strip as earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. (Copper strip upto 7.5m including testing consider in this item). [Note : (a) Proper earthing pit should be provided with pit cover. (b) The unit rate includes for protection pipe and earth strip upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (c) Excavation/earthwork is deemed to be included in the quoted rate.
Cutting, screwing without taking down existing DI water tubing of size 150 mm bore, for addition/alteration complete all as specified and directed.
S&F for ductile iron pipes fittings both flanged & socket type (socket,bend, nipple, Y & tail piece flange etc) and including all jointing mateials of pipes of size upto 150mm complete all as specified and directed.
Supplying, installation of silent Diesel Engine Driven generating set 415 volt, 3 phase 4 wire 0.8 PF,engine as per IS 10001/10002 and alternator as per IS 13364 complete with relay panel and switch gears for Automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation of capacity 30 KVA Comprising and including of following:- (A) DIESEL ENGINE: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete with following:- (a) Radiator with blower fan or heat exchangar with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter complete with first filling of lub oil (iii) Bypass filter (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type replaceable air cleaners and vacuum indicators. (j) Residential silencers.
Serial Item No. 15.41 (Contd....) (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC 'C' class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class (s) Self starter (t) Electric operated electronic governor. (u) Fuel injection pump. (v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) Battery as per manufacturer recommendation. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500 RPM (v) Engine hours (vi) Frequency. (vii) Voltage. (viii) Safety control (Trip and indication). (ix) High water temperature (x) Low lube oil temperature & (xi) Overspeed stop
Serial Item No. 15.41, 15.42 &15.43 (Contd....) (c) Suitable battery charger connected to load side to charger battery including connecting leads. (Note: AMF Panel shall be installed out side the acoustic enclosure). (E) BASE PLATE: Common fabricated base frame for engine & alternator made from structural Steel channel, jerk proof on PCC 1:2:4 type B1 foundation including adequate number of anti-vibration pads in adequate quantity all as per the recommendation of the manufacturer. (Note:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor). (F) DIESEL STORAGE TANK: Fuel tank of MS sheet of capacity not less than 12 Hrs continuous operation on full load with fuel level guage, drain plug, locking arrengements, etc including connection to Engine through fuel filter/ manual feed pump as per manufacturer recommendation. (G) ACOUSTIC ENCLOSURE: Sheet metal fabricatedcope type silent enclosure manufactured on CNC machines as per CPCB norms and power coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, laveling certification etc as laid down in GSR No.371(E) dt 17 May 2002 or latest. (H) MISC: Tool kit operation, maint cat, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturers standard practice. (j) PCC foundation for DG Set to be provided as per OEM standard foundation drawing and foundation cost shall deemed to be included on the quoted rate. (k) Adequate diesel and load bank for 12 Hrs fall load testing shall be provided by the contractor during testing and commissioning of DG Set.
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m, complete all as specified and directed.
Demolition of brickwork or stone/boulder masonary, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, etc. all as directed.
S&F portable type fire extinguisher of 9 Kg , cylindrical in shape, foam type fixed inside the lift and exit way staircase wall and entrance door of each quarter including complete mounting accessories complete all as specified and as directed.
S & F Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard for keeping 2 Nos hose pipe of length 15 and 30 meter each, branch pipe.nozzle, coupling etc complete all as specified and as directed (Note : Nozzle head should be made up of brass metal heavy grade as per IS grad. Hose box needs to be provided with lock and key facilities
S & F electric motor siren conforming to IS-1941 suitable for three phase 415V with motor not exceeding 3.75 KW power and able to deliver 143 dB noice level complete all as specified and as directed.
S&F emergency exit display board of size 30cm x 10cm, at exit point of each floor made up of acrlylic cover with pre-wired LED lights for illumination at night complete all as specified and as directed. Note: (i) Writing letters shall be displayed in red colour. (ii) Concealed type Point wiring shall be provided with switch control by taping from nearest junction box or nearest point by the contractor.
Supply of automated electro-mechanically operated, organic waste composter machine with carbon Bio-filter and control panel of capacity 30 kgs/day complete all as specified and as directed. (Model- standard (KCST30) or equivalent
Supply of food waste shedder of 3 HP complete all as specified and as directed.
Supply, installation, testing and commissioning of 'Solar Hot Water System' (Flat Plate Collector) based on indirect transfer of heat of capacity 600 lit per day including external heating element complete all as specified and as directed.
S & F CPVC pipe of pressure rating SDR-11, 50mm dia laid in floor/wall/roof with all fittings including nuts, bolts, washers, clamps etc complete all as specified and as directed.
S & F CPVC pipe of pressure rating SDR-11, 25mm dia laid in floor/wall/roof with all fittings including nuts, bolts, washers, clamps etc complete all as specified and as directed.
S & F CPVC pipe of pressure rating SDR-11, 20mm dia laid in floor/wall/roof with all fittings including nuts, bolts, washers, clamps etc complete all as specified and as directed.
S & F thermal foram insulation with glass wool and aluminium covered pipe fir GI pipe self adhesive pipe form thickness 5mm suitable for 25mm CPVC pipe for protection to Hot water pipe complete all as specified and as directed.
S & F gun metal globe or gate valve ISI Marked with wheel head, screwed both ends for CPVC pipes, suitable for 50mm dia pipe complete all as specified and as directed.
S & F gun metal globe or gate valve ISI Marked with wheel head, screwed both ends for CPVC pipes, suitable for 25mm dia pipe complete all as specified and as directed.
S & F gun metal globe or gate valve ISI Marked with wheel head, screwed both ends for CPVC pipes, suitable for 20mm dia pipe complete all as specified and as directed.
S & F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410 -W (Gde E 250) quality- A including cutting, weling, grinding sharp corners, fabrication works for ladders for UG sump and OH tanks including two coats of black paint over a coat of red oxide primer complete all as specified and as directed.
S & F EV DC charger point of capacity 30 KW Model CCS2 SP-ST-EV30DC, charging gun as per CCS2 standard one output for charging port, input voltage rating 3 phase 415V, input frequency 50 Hz, one No MCCB input in charger, input supply failure battery back up minimum for 15 minutes, output current 100A per gun maximum, ambient temperature range suitable for Indian climate -20 degree cent to 55 degree cent, user authentication RFID/QR code Scan OCPP 1.6J, connectivity -GSM/Ethernet/Wifi complete all as specified and as directed.
S & F 500 litres capacity rotational moulded polyethylene (HDPE) water storage tanks (Cylindrical vertical with closed top), ISI Marked, conforming to IS 12701-1989 having triple layers wall construction with manhole threaded lid and suitable locking arrangement including making holes for inlet, outlet and over flow pipes,hoisted and fixed in position complete all as specified and directed.
M & L for PCC (1:3:6) , type C-1 (using 20 mm graded crushed stone aggregate) in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including formwork if required , complete all as specified and as directed
Comrehensive maintenace of 02 Nos electrically operated 13 passenger lift suitable for G+4 floors with electric power operated doors , auto electric levelling device completewith ARD facility installed at Provn of deficient married accn for offrs at HQ EAC(U) for a period of 12 months (1st year after expiry of defect liability period of Phase-I). Repairs/Replacement of defective / unserviceable part like LCD display,electromechanical locks,safety devices of lifts and other accessories of the lift etc and in addition of break down maintenance to the monthly, half yearly and yearly maintenance as per mentioned in company catalouges. Contractor shall carry out break down maintenance also. In case of break down, the contractor's mechanic shall reach at site within on hour whenever any break down is repoted to the contractor or his representative telephonically / through email or any other media of communication. The contractor shall specify their office / residence / work place phone numbers or mobile numbers for lodging break down complaints round the clock i.e. 24x7 Hrs. Note : 1. Activities covered in the above schedule shall not be exhaustive, if any activity required being included later on due to reliability and safety shall be carried out by the contractor without any extra cost. 2. The contractor shall enter into a MOU with the OEM for the provision of the lift and further maintenace. The MOU for the post warranty, Post defect liability period between the contractor and OEM shall be submitted at least six month prioir to the issue of completion certificate of the main contract. 3. Maintenace of lifts shall be maintained through OEM .
All as per item No 15.65 here-in before but for a period of 12 months (Second year after expiry of defect liability period of Phase-I).
All as per item No 15.65 here-in before but for a period of 12 months (Third year after expiry of defect liability period of Phase-I).
NOTE: Schedule of cedit (Sch 'A' Part- XVI) amount of Rs 41,250.00 shall be deducted from the total quoted amount of BOQ.
M/s Gupta Construction (BID ID -3241752)
M/S Tanisha Traders (BID ID -3241642)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .