Loading…
Loading…
Tender Value
₹45.0 L
EMD Value
₹90,000
Closing Date
6 Oct 2026, 6:00 pm
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YE
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
ANNUAL MAINTENANACE OF TROLLEY GATE, SOLAR FENCING, SOLAR POWER PLANT AT ASTE AND COMPREHENSIVE MAINTENANCE OF UPS SYSTEM AND SERVO VOLTAGES STABLIZER AT VARIOUS LOCATION UNDER GE(AF) MARATHAHALLI.
2026_MES_789493_1
GE (AF) MARATHAHALLI / 8872 / E8
Open Tender
Civil Works
Item Rate
365 days
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YE
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YE
₹90,000
Yes
15 Sept 2026
15 Sept 2026
8 Oct 2026
15 Sept 2026
6 Oct 2026
29 Sept 2026
27 Sept 2026 - 6 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive maintenance of UPS 3 KVA (03 Nos) any make at various locations with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carried in a three months all as directed by Engr-in-Charge.
Note :-(i) The report shall be submit to the Engr-in-Charge
(ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint
(iii) The Battery will be measured and paid seperately.
(iv) The rate inclusive of all defects parts.
Note :- 03 Nos UPS of 3 KVA will be measured as one job. | 3 | Each Job | 1.25 | ₹3.75 |
| 2 | Comprehensive maintenance of UPS 4 to 5 KVA (01 No) any make at various locations with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carried in a three months all as directed by Engr-in-Charge.
Note :-
(i) The service report shall be submit to the Engr-in-Charge
(ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint
(iii) The Battery will be measured and paid seperately.
(iv) The rate inclusive of all defects parts. | 3 | Each Job | - | - |
| 3 | Comprehensive maintenance of UPS 6 to 8 KVA (01 No) any make at various locations with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carried in a three months all as directed by Engr-in-Charge.
Note :-
(i) The service report shall be submit to the Engr-in-Charge
(ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint
(iii) The Battery will be measured and paid seperately.
(iv) The rate inclusive of all defects parts. | 3 | Each Job | 100 | ₹300 |
| 4 | Comprehensive maintenance of UPS 10 KVA (04 Nos) any make at various location with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carried in a three months all as directed by Engr-in-Charge.
Note :-(i) The service report shall be submit to the Engr-in-Charge
(ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint
(iii) The Battery will be measured and paid seperately.
(iv) The rate inclusive of all defects parts.
Note :- (i) 04 Nos UPS of 10 KVA will be measured as one job. | 3 | Each Job | 53 | ₹159 |
| 5 | Comprehensive maintenance of UPS 15 KVA (01 No) any make at various location with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carried in a three months all as directed by Engr-in-Charge.
Note :-
(i) The service report shall be submit to the Engr-in-Charge
(ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint .
(iii) The Battery will be measured and paid seperately.
(iv) The rate inclusive of all defects parts. | 3 | Each Job | 10 | ₹30 |
| 6 | Comprehensive maintenance of UPS 20 KVA (02 Nos) any make at various locations with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carried in a three months all as directed by Engr-in-Charge.
Note :-
(i) The service report shall be submit to the Engr-in-Charge .
(ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint
(iii) The Battery will be measured and paid seperately.
(iv) The rate inclusive of all defects parts.
Note :- (i) 02 Nos UPS of 20 KVA will be measured as one job. | 3 | Each Job | 11 | ₹33 |
| 7 | Comprehensive maintenance of UPS 30 KVA (02 No) any make at various locations with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carried in a three months all as directed by Engr-in-Charge.
Note :-
(i) Theservice report shall be submit to the Engr-in-Charge
(ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint
(iii) The Battery will be measured and paid seperately.
(iv) The rate inclusive of all defects parts.
Note :- (i) 02 Nos of UPS of 30 KVA will be measured as one job. | 3 | Each Job | 10 | ₹30 |
| 8 | Comprehensive maintenance of UPS 60 KVA (01 No) any make at various locations with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carried in a three months all as directed by Engr-in-Charge.
Note :-(i) The quarterly service report shall be submit to the Engr-in-Charge
(ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint
(iii) The Battery will be measured and paid seperately.
(iv) The rate inclusive of all defects parts. | 3 | Each Job | 22 | ₹66 |
| 9 | Comprehensive maintenance of UPS 80 KVA (01 No) any make at various locations with complete calibration of systems, including all parameter as per manufacurer design servicing rectification of defects replacement of required parts etc servicing carried in a three months all as directed by Engr-in-Charge.
Note :-
(i) The service report shall be submit to the Engr-in-Charge
(ii) The complaint should be attended with in 04 to 06 hrs after giving the complaint.
(iii) The Battery will be measured and paid seperately.
(iv) The rate inclusive of all defects parts. | 3 | Each Job | - | - |
| 10 | Repair and maintenance of servo voltage stabilizer oil cooled/Air cooled 1 KVA to 15 KVA any make at various locations with complete calibration of systems, including all parameter as per manufacturer design servicing rectification of defects replacement of required parts etc the parts measured in relevant schedule all as directed by Engr-in-Charge.
Note : (i) The service report shall be submit to Engr-in-Charge
(ii) Parts to be measured and paid seperately. | 10 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
TENDER8872.pdf
Tender Documents • 0.53 MB
BOQ_885004.xls
BOQ • 0.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .