Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹25.2 L+₹4.4 L (21.0%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-AOC Higher rate | |
| 3 | Rejected-Technical WZ 1391 31 B NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | - | Rejected-Technical Not Recommended being not enlisted in desired category |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
20 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NEW DELHI
GE New Delhi, Rao Tula Ram Marg, Delhi Cantt-10
REPAIR AND MAINTENANCE OF COOLING APPLIANCES, WINDOW TYPE, SPLIT TYPE, CASSETTE TYPE ACS AT HQ IDS, DAIRA, AFC, AFDC, ABH MESS, TPT COY AND NAVAL AREAS UNDER GE NEW DELHI
2021_MES_453725_1
GE/ND-17/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NEW DELHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NEW DELHI
₹66,000
Yes
9 Sept 2021
22 Jun 2021
27 Jul 2021
22 Jun 2021
20 Jul 2021
6 Jul 2021
60 days
Amount
Labour for checking and attending complaints of ACs, water coolers, Refrigerators etc. of any capacity, including rectification of minor defects and making the equipment functional complete all as specified and directed. (Note : 1) Any parts required for replacement shall be measured and paid separately under respective items 2) The contractor should detail minimum one AC Mechanic & one helper to attend complaints in HQ IDS, DAIRA, AFC, AFDC, ABH Mess, TPT coy & Naval Areas 3) The complaint should be attended on same day. 4) If the complaint not attended/not completed on same day, recovery will be done as follows:- a) For first day @ Rs.200/- b) For second day @ Rs.300/- c) For every next day @ Rs.500/-
Servicing of Window type AC 1.5/2 Ton capacity of any make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
All as per item No 2.00 here-in-before but Split type AC of any type and 1.5/2 Ton capacity.
Servicing of three phase cassette type split AC 3.5 to 4.0 Ton capacity of any make/model with indoor and outdoor unit by taking out the AC, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and as directed. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
Supply only starting capacitor 80-100 Mfd suitable for AC 1.5 Ton complete all as specified and as directed. Make : Usha/Epcos/Havells/Tesla
Supply only starting capacitor 100-120 Mfd suitable for AC upto 4.00 Ton complete all as specified and as directed. Make : Usha/Epcos/Havells/Tesla
Supply only Running capacitor 36 mfd 230 volt suitable for AC 1.5 Ton complete all as specified and as directed. Make : Usha/Epcos/Havells/Tesla
Supply only running capacitor 45 mfd 230 volt suitable for AC 2 Ton complete all as specified and as directed. Make : Usha/Epcos/Havells/Tesla
Supply only running capacitor combination 50 mfd + 6 mfd 230 Volt for AC upto 4.00 Ton complete all as specified and as directed. Make : Usha/Epcos/Havells/Tesla
Supply only Running capacitor 6 mfd 230 volt complete all as specified and as directed. Make : Usha/Epcos/Havells/Tesla
Supply only Running capacitor 4 mfd 230 volt complete all as specified and as directed. Make : Usha/Epcos/Havells/Tesla
Supply & charging gas refrigerant R-22/R 410 A/ R-32 or as existing to window type AC up to 2 Ton capacity including removing of leakage if any and testing complete all as specified & directed by Engineer-in-charge. Make- Mafron/Refron/Refromax
All as per item No. 12.00 here-in-before but for Split AC of any type and 1.5/2 Ton capacity.
Supply & charging the gas refrigerant R-22/R 410 A or as existing to cassette type Split AC 3.5 to 4.0 Ton capacity including removing of leakage if any and testing complete all as specified & directed. Make- Mafron/Refron/Refromax
Supply & fix in replacement starting relay suitable for 1.5/2 Ton capacity AC complete all as specified and as directed. Make : Renutrol/Classic/Indfos
Supply & fix in replacement over load protector suitable for 1.5 Ton capacity AC complete all as specified and as directed. Make : Pacific/ranutrol/Hitech
Supply & fix in replacement thermostat switch suitable for 1.5/2 Ton capacity AC complete all as specified and as directed. Make : Pacific/ranutrol/Indfos
Supply & fix against in replacement of unserviceable starting relay suitable for 4.0 Ton capacity AC complete all as specified and as directed. Make : Renutrol/Classic/Indfos
Supply & fix against in replacement of unserviceable over load protector suitable for 4.0 Ton capacity AC complete all as specified and as directed. Make : Pacific/ranutrol/Hitech
Supply & fix against in replacement of unserviceable thermostat switch suitable for 4.0 Ton capacity AC complete all as specified and as directed. Make : Pacific/ranutrol/Hitech
Material and labour for taking down of defective /unserviceable reciprocating compressor of split type AC capacity 1.5 TR and replacing the same with new compressor reciprocating type capacity 1.5 TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/Carrier/Tecumseh/Copeland/ existing make
Material and labour for taking down of defective /unserviceable rotary compressor of split type AC capacity 1.5 TR and replacing the same with new compressor rotary type capacity 1.5 TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/Carrier/Tecumseh/existing make
Material and labour for taking down of defective /unserviceable reciprocating compressor of split type AC capacity 2.0 TR and replacing the same with new compressor reciprocating type capacity 2.0 TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Carrier/Copeland/existing make ACs complete all as specified.
Material and labour for taking down of defective /unserviceable rotary compressor of split type AC capacity 2.0 TR and replacing the same with new compressor rotary type capacity 2.0 TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Carrier/Copeland/existing make ACs complete all as specified.
Supply and fixing in replacement after taking down defective /unserviceable AC reciprocating compressor of capacity 3.5/4.0 TR , refixing new compressor of 3.5/4 Ton including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. of three phase compressor suitable for 3.5 to 4.0 Ton capacity for Cassette Type AC 3.5/4.0 Ton. Make: Kirloskar/Carrier/Daikin/existing make ACs complete all as specified.
Supply & fix in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity window type ACs complete all as specified and as directed.
All as per item No 26.00 here-in-before but for Split type ACs complete all as specified and as directed.
Supply & fix in replacement item of air filter synthetic / nylon type as per existing size and shape suitable for 3.5/4.0 Ton capacity cassette type split ACs complete all as specified and as directed.
Material and labour for taking down existing unserviceable blower motor (Indoor) capacity 1/4,1/5 HP single/double shaft as per existing and refixing with new blower motor in replacement as per existing model on site suitable for Split type ACs 1.5/2 Ton complete all as specified and directed. Make : LG/Career/Voltas/Hitachi.
Material and labour for taking down existing unserviceable outdoor fan motor and fixing of new fan motor capacity 1/4,1/5 HP single/double shaft as per existing model suitable for Split type ACs 1.5/2 Ton complete all as specified and directed. Make : LG/Career/Voltas/Hitachi.
Material and labour for taking down existing unserviceable blower motor capacity 3.5/4.0 Ton and fixing of new fan motor in replacement single/double shaft as per existing model suitable of any make/type complete as per requirement on site all as specified. Make : LG/Career/Voltas/Hitachi.
Material and labour for taking down existing unserviceable outdoor fan motor capacity upto 4 Ton and taking the unserviceable fan motor outdoor type to authorized workshop for rewinding of fan motor suitable for ACs capacity up to 4 Ton capacity with super enameled copper winding wire of same gauge including replacement of insulating material, bushes and shaft all as specified & directed.
Supply & fix in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 70/.0076 (2.5 sqmm) complete all as specified and as directed.
All as per item No 33.00 here-in-before but 4 core.
Supply & fix in replacement condensor fan blade made out of aluminium suitable for upto 2 Ton capacity window type ACs.
All as per item No 35.00 here-in-before but for Split ACs of 1.5/2.0 Ton capacity
Supply & fix in replacement of condensor fan blade made out of aluminium suitable for upto 4.0 Ton capacity cassette type split ACs complete all as specified & directed.
Supply & fix in replacement of evaporating air blower made out of aluminium suitable for upto 2 Ton capacity for window type AC all as specified and directed
All as per item No 38.00 here-in-before but for air blower of Split ACs of 1.5/2 Ton capacity
Supply & fix in replacement of item of evaporating air blower made out of aluminium suitable for upto 4.0 Ton capacity cassette type split ACs complete all as specified & directed.
Supply and fix in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split AC units. Make:- Supreme/Gulf-o-flex/Superlon.
All as per item No 41.00 here-in-before but internal dia 13 mm (1/2")
Material and labour for replacement of front grill suitable for window type ACs upto 2 Ton capacity of any Make as per existing size and shape complete all as specified and as directed.
Material and labour for replacement of reverse valve system suitable to 1.5/2 Ton split/window AC for heating option. (Note: Gas charging shall be paid and measured under respective item)
Supply and fix in replacement copper tubing heavy duty inner dia 6 mm (1/4") for refrigerant for Split type ACs capacity upto 4 Ton. Make-Carrier/ Totalline/Godrej
Supply and fix in replacement of copper tubing heavy duty inner dia 13mm (1/2") for refrigerant for Split Type ACs capacity upto 4 Ton. Make- Carrier/Totalline/Godrej
Material and labour for taking down existing condensing coil by removing it from existing outdoor unit by using LPG blower and fixing of new condensing coil of suitable size/capacity for 1.5/2 Ton split type ACs complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
Material and labour for taking down existing evaporating coil by removing it from existing indoor unit by using LPG blower and fixing of new evaporating coil of suitable size of existing make, capacity for 1.5/2 Ton split type ACs complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil.
Material and labour for taking down existing condensing coil by removing it from existing outdoor unit by using LPG blower and fixing of new condensing coil of suitable size/capacity for 1.5/2 Ton window type ACs in replacement as per existing size/shape and as per existing make complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil.
Material and labour for taking down existing evaporating coil by removing it from existing unit by using LPG blower and fixing of new evaporating coil of suitable size/capacity for 1.5/2 Ton window type ACs in replacement as per existing size/shape and as per existing make. Complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil.
Material and labour for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas R-12/22/134a for water cooler, Split type/Window type AC/ Deep Freezer /Refrigerator any size any capacity as on site complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement brass flare nut/connector heavy duty of size 6 mm/9 mm (1/4", 1/2") as per existing make complete all as specified and as directed.
Material and labour for Repair of control processing board (Remote control kit) with handset including replacement of current transformer, ICs, diodes, resistances, sensors etc complete for 1.5/2 Ton split type ACs of any make & model complete all as specified and as directed.
Material and labour for replacement of unserviceable display along with PCB suitable for Split type AC 1.5/2 TR with new PCB along with display unit. Make-Hitachi/Voltas/Carrier/Daikin
Material and labour for replacement of unserviceable display along with PCB suitable for Cassette Type AC 3.5/4TR with new PCB along with display unit. Make-Hitachi/Voltas/Carrier/Daikin
Material and labour for opening and taking down existing unserviceable PCB along with display unit and fixing of new PCB along with display unit suitable for Indoor unit of Inverter AC of capacity1.5/2 Ton split type AC complete all as specified and directed by Engr-in-Charge.
Material and labour for opening and taking down existing unserviceable PCB and fixing of new PCB suitable for Outdoor unit of 1.5/2 Ton split type inverter AC complete all as specified and directed by Engr-in-Charge.
Material and labour for taking down unserviceable condensor fan motor of outdoor unit inverter type and supply and fix in replacement DC motor 125 W suitable for outdoor unit of Inverter type AC of capacity 1.5/2.0 Ton complete all as specified and as directed by engr-in-Charge
Material and labour for taking down existing unserviceable compressor of Inverter type AC 1.5/2 TR and replacement of same by new hermetically sealed rotary compressor of capacity suitable for Inverter type AC 1.5/2 Ton refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge
Supply and fixing in replacement window AC kit 1.5/2.0 TR with sensor complete with condensing coil, blower and motor suitable to existing model and make AC all as specified and directed. Make:- Carrier, Napolean & Skoda
Supply and fix in replacement split type AC indoor unit kit 1.5 TR capacity complete with cooling coil, blower with motor, PCB and remote complete with fixing plate suitable to existing model and make AC all as specified and directed. Make- Hitachi/Carrier/Daikin.
Supply and fix in replacement split type AC outdoor kit 2.0 TR complete with condensing coil, condensor fan motor suitable to existing model and make iron grill, suitable for outdoor unit and flair nuts for connection of Copper pipe all as specified and directed. Make- Hitachi/Carrier/Daikin
Supply & fix in replacement direction changer louver motor ( swing motor) suitable for split type ACs 1.5/2 capacity as per existing make and model
Supply & fix in replacement cordless Remote for inverter type ACs Hot & cool suitable for 1.5/2 Ton AC as per sample. Make- Hitachi/Voltas/Carrier
Supply & fix in replacement cordless Remote for ACs suitable for 1.5/2 Ton AC as per sample. Make- Hitachi/Voltas/Carrier
Servicing of package type AC 11 Ton capacity complete with blower motor dismantling all parts and refixing after cleaning and replacement of defective parts, dismantling the cover of condensing coil carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water and dry properly including using air blower for cleaning air dust deposited on the equipment and re-fixing the same after repair complete all as specified. Note:- Spare parts shall be measured and paid separately.
Material and labour for taking down existing unserviceable compressor and fixing in replacement new hermetically sealed compressor suitable for 5.5 Ton capacity package type refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Tecumsheh/Copeland/Danfoss/existing make ACs complete all as specified.
Supply & charging the gas refrigerant R-22/R 410 A or as existing to package type AC's of capacity 11 (2x5.5) Ton capacity including removing of leakage if any and testing complete all as specified & directed.
Supply and fix in replacement of HP cut-out suitable for package type ACs of capacity 11 (2x5.5) Ton complete all as specified.
Supply and fix in replacement of expansion valve suitable for package type ACs of capacity 11 (2x5.5) Ton complete all as specified.
Material and labour for taking down of unserviceable PCB and transporting it to authorized workshop for its repair complete along with necessary accessories like diodes, resistors, capacitors for PCB card suitable for package type AC's of capacity 11 (2x5.5) Ton complete all as specified and as directed by Engr-in-Charge.
Material and labour for Repair/maint and servicing of micro roster based panel of package type AC's of capacity 11 (2x5.5) Ton complete including replacement of faulty diode, resistance, solenoid coil complete all as specified and as directed by Engr-in-Charge.
Material and labour for taking down existing unserviceable fan blade and replacement of new condensor fan blade made out of aluminium/plastic suitable for package type AC's of capacity 11 (2x5.5) Ton complete all as specified and as directed by Engr-in-Charge.
Material and labour for taking down existing unserviceable blower and replacement by new evaporating air blower made out of aluminium/plastic suitable for package type AC's of capacity 11 (2x5.5) Ton complete all as specified and as directed by Engr-in-Charge..
Material and labour for taking down unserviceable fan motor and supply and fix in replacement new fan motor single/double shaft as per existing model suitable for package type AC's of capacity 11 (2x5.5) Ton complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement air filter synthetic / nylon type as per existing size and shape suitable for package type AC's of capacity 11 (2x5.5) Ton complete all as specified and as directed by Engr-in-Charge..
Servicing of Water cooler of 40,60,120,150 ltr capacity of any make / model by cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning, greasing, oiling of fan motor and checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge
Supply & charging the gas refrigerant R-134 or as existing to water coolers up to 150 ltr capacity including removing of leakage if any and testing complete all as specified & directed
Taking down of defective /unserviceable reciprocating compressor of Water Cooler 80 L and replacing the same with new compressor reciprocating type capacity upto 80 Ltrs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make:- LG/Kirloskar/Carrier/Tecumseh/Copeland
Material and labour for taking down existing condensing coil from water cooler any capacity and replacement by new Condensor coil as per existing capacity including brazing and dehydration by creating vacuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system. Complete all as specified and as directed by Engr-in-Charge.
Material and labour for taking down fan motor of water cooler capacity upto 150 Litres and replacement of the same by new fan motor as per existing on site upto capacity 150 litres along with fan blade and along with all mountings complete all as specified and as directed by Engr-in-Charge.
Servicing of Refrigerators of 165 to 310 ltr capacity single door of any make / model by cleaning of condensing coil with wire & brush to remove dust including checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge.
Material and labour for taking down existing unserviceable condensing coil from Refrigerators of any capacity and replacement by new Condensor coil as per existing capacity upto 310 Ltrs including brazing and dehydration by creating vacuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system. Complete all as specified and as directed by Engr-in-Charge.
Material and labour for taking down unserviceable fan motor of refrigerators of any capacity upto 310 Litres and replacement of the same by new fan motor as per existing on site upto capacity 310 litres along with fan blade and along with all mountings complete all as specified and as directed by Engr-in-Charge.
Material and labour for Taking down of defective /unserviceable reciprocating compressor of Refrigerator capacity upto 310 Ltrs and replacing the same with new compressor reciprocating type capacity 310 Ltrs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/LG/Tecumseh
Supply & charging the gas refrigerant R-134a or as existing to Refrigerators up to 310 ltr capacity including removing of leakage if any and testing complete all as specified & directed
Supply & fix in replacement of unserviceable starting relay suitable for 165 to 310 ltr capacity Refrigerator
Supply & fix in replacement of unserviceable over load protector suitable for Refrigerator capacity upto 310 ltrs
Supply & fix in replacement thermostat switch suitable for Refrigerator capacity upto 310 L
Material and labour for Servicing of Deep fridger 310 ltr capacity 2/3 door of any make / model by cleaning of condensing coil with wire & brush to remove dust including checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge
Supply & charging the gas refrigerant R-134a or as existing to Deep Freezers up to 310 ltr capacity including removing of leakage if any and testing complete all as specified & directed
Material and labour for taking down existing unserviceable condensing coil from Deep freezers of any capacity and replacement by new Condensor coil as per existing capacity upto 492 Ltrs including brazing and dehydration by creating vacuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system. Complete all as specified and as directed by Engr-in-Charge
Material and labour for taking down unserviceable fan motor of deep freezer of any capacity upto 380 Litres and replacement of the same by new fan motor as per existing on site upto capacity 380 litres along with fan blade and along with all mountings complete all as specified and as directed by Engr-in-Charge
Material and labour for Taking down of defective /unserviceable reciprocating compressor of Deep freezers of capacity upto 380 Ltrs and replacing the same with new compressor reciprocating type capacity upto 380 Ltrs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge Make : Kirloskar/LG/Tecumseh/Copeland
Supply & fix in replacement of unserviceable starting relay suitable for 165 to 492 ltr capacity Deep freezer
Supply & fix in replacement of unserviceable over load protector suitable for Deep freezer capacity upto 492 L
Supply & fix in replacement thermostat switch suitable for Deep Freezer upto 492 L
Collecting the U/S single phase voltage stabilizer of capacity from 02 KVA to 05 KVA from MES complaint cell to local workshop/in-situ for repair and open the stabilizer taking out u/s spare parts incl replacement of the same with new one, incl testing complete all as specified and directed. (Note: Replacement of spare parts will be measured and paid seperately. )
Supply only relay for voltage stabilizer suitable for 2 KVA to 5 KVA capacity stabilizer
Supply only for printed circuit board ( PCB) suitable for 2 KVA capacity stabilizer
Supply only for printed circuit board ( PCB) suitable for 3 KVA capacity stabilizer
Supply only for printed circuit board ( PCB) suitable for 5 KVA capacity stabilizer
Supply only for main transformer suitable for 2 KVA capacity stabilizer
Supply only for main transformer suitable for 3 KVA capacity stabilizer
Supply only for main transformer suitable for 5 KVA capacity stabilizer
Supply only for voltmeter analog type 0 to 300 volts (as per sample) complete all as specified.
Supply only for ammeter analog type 0 to 30 Amps (as per sample) complete all as specified.
Supply & Fix in replacement of connector block porcelain 4 way suitable for 30 Amps capacity complete all as specified.
Supply and fix only for plug top 3 pin, 15 Amps, 230 volts, 50 Hz AC complete all as specified.
Material and labour in replacement Metal Clad Plug & socket board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz , with MCB SP 20-32 Amps complete all as specified and as directed by Engr-in-Charge. Make- Havells Cat part No- DHDPUSN020/DHDPUDP020 or equivalent in Legrand ABB, Schneider
Supply and fix in replacement of PVC insulated and PVC sheathed, flexible copper conductor cable 3 core, 1100 volts grade, multi stranded type of size 6.0 sqmm complete all as specified.
Material and labour for taking down of desert cooler and Servicing of Desert cooler of any type/ capacity cleaning of tank, painting with black paint after cleaning including checking of electric circuit for smooth functioning of desert cooler complete all as specified and directed.
Supply and fix in replacement of desert cooler pad (in set of three) suitable for cooler of Size as required at site complete all as specified & directed.
Material & labour taking down of desert cooler fan motor and transporting the unserviceable motor to workshop for rewinding of desert cooler fan motor with supper enameled copper winding wire of same gauge including replacement of insulating material, bushes, bearing and shaft after taking out burnt wire including transportation to civil workshop complete all as specified & directed.
Supply & fix in replacement ON/OFF switch of desert cooler complete all as specified.
Supply & fix in replacement of step type desert cooler regulator complete all as specified.
Supply & fix in replacement of drain pipe PVC flexible, spring type of size 15 mm dia as per site requirement complete all as specified.
M & L for repair, servicing/periodical maintenance to RO Plant of capacity 50/150 LPH including replacement of minor spares, Pump repair, refixing the plant after repair, testing complete all as specified and directed of entire satisfactory level by Engr-in charge. Note: Spares required shall be measured and paid under relevant items
Supply only Membrane suitable for 150 LPH RO Plant
Supply only Filter heavy Grade for 150 LPH RO Plant
Supply only Electrical accessories ,Solenoid valve, for 150 LPH RO Plant
Supply only Membrane for 50 LPH RO Plant
Supply only activated carbon Filter heavy Grade for 50 LPH RO Plant
Supply only Electrical accessories Solenoid valve for 50 LPH RO Plant
Supply & fix in replacement HDPE pipe 3/8"dia suitable for inlet & outlet of RO plant all as specified
S & F in replacement of booster pump for 50 LPH RO Plant
S & F in replacement of booster pump for 150 LPH RO Plant
Material and labour for Shifting to new location, window type ACs 1.5 /2.0 TR capacity including removing of connected accessories all as directed by Engr -in- charge
Material and labour for Shifting of Split type Acs 1.5 /2.0 TR capacity to new location including removing of indoor unit, out door unit and connected accessories all as directed by Engr -in- charge
RUCHIKA ENGG.WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .