| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.0 CrAccepted-AOC | ₹4.0 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹4.0 Cr+₹2.4 L (0.61%)Rejected-AOC | ₹4.0 Cr+₹2.4 L (0.61%) | 2 | Rejected-AOC L2 |
| 3 | 3₹4.0 Cr+₹4.3 L (1.08%)Rejected-AOC HARIHAR NIWAS BESANT STREET SANTACRUZ W MUMBAI | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | ₹4.0 Cr+₹4.3 L (1.08%) | 3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹4.9 L
Closing Date
28 Oct 2024, 4:00 pmClosed
EEMech(EI)Const.
Office of Chief Engineer (Mechanical Electrical), Engineering Hub Building, Dr. E. Moses Road, Worli Naka, Worli, Mumbai 400 018.
Design and up-gradation of Burns Care Unit with multifarious work in City Area.
2024_MCGM_1111232_1
Ch.Eng./MnE/4139 dt.10.10.2024
Open Tender
Electrical Works
Item Rate
270 days
Kasturba Hospital
please refer tender documents
3 documents required · 3 mandatory
₹19,470
₹4.9 L
ch.eng. (MnE) Office
24 Jan 2025
11 Oct 2024
29 Oct 2024
11 Oct 2024
28 Oct 2024
11 Oct 2024
25 Oct 2024
Amount
Light /Fan / Ex. fan Points
2/3 Pin Independent Plug (IP)
15 / 5 A / 6 A Combined Power Plug Socket Point with Fuse and Indicating Lamp, One 15 Amp SP Switch
5A/6A - 3/5 Pin Plug On Board
INDOOR LED FIXTURES - -LED Square Recessed Downlighter- 45W (600x600)
IP 42 Wall/column Mounted distribution board with one Nos of DP 16/32A MCB as incomer and 8 Noss 6A/10A SP MCB as outgoing (12 way SPN DB)
IP 42 Wall/column Mounted distribution board with one Nos of 63A 4P MCB as incomer and 4 Noss 16A TP MCB as outgoing (4 way TPN DB)
1st category Cu armoured cables FRLSZ outer sheathed- 3C x 6 Sq.mm
1st category Cu armoured cables FRLSZ outer sheathed- 4C x 25 Sq.mm
Earthing Continuity Conductors -Bare Copper Conductor size 10 SWG
600 X 600 X 3.15 mm Copper Plate, 3000mm dip with suitable size cu strip earth pit as per IS 3043. The earth pit shall be provided with watering pipe (Class B) with wire messed funnel, 25X3 cu strip / 2X8SWG Cu.wire up to chamber, disconnecting links with 600 x 600 mm (clear) RCC chamber & 3mm thick heavy duty CI chequered plate cover with hinge. Bentonite shall be provided for earth pits. Excavation, back filling, removal of excess soil is included in the scope
Earthing Continuity Conductors -25 x 3mm Tinned copper
LED Spot Light
Conference Controller shall have 50 Watt Central Mixer Amplifier minimum 64)
Delegate unit Microphone
6W/100V. PA Ceiling Speaker
Wiring for speakers with 24/0.2 multicore twin twisted flexible copper.
PVC Telephone Cable -2 pair
Cat 6 Gigabyte
Supply & laying of PVC conduit for speaker wiring
Supply of 1 mm thick Wall Sheets ( Size of 9 X 4 Ft. )
Wall Surface leveling with wall putti and protective base coat
Supply & Installation of Metal Stainless Steel Strips with allid work
supply & inst of PVC Corner Guard with allied accessories.
Supply & Int. 2mm Non- Electrocunductive Vinyl Flooring with addhesive chemical Required.
Floor Surface Leveling with Self Levelling Compound
Supply & Insallation of Fully Motorised ICU Bed, IV Pole, Mattress, Bedside Locker and Bedside Table
Supply & Insallation of Crash Cart Imported
Supply & Insallation of Stretcher Trolley
SITC OF Two Plate X-Ray Viewing Screen designed to provide a high level of control luminance without flicker. Size- 950 X 650 X 115 mm
SITC OF 2- Bay Scrub Sink, with Infrared Photo sensor, Digital Timer with user defined Time interval 1,3,5 and 10minutes,1 no. mixture valve and 1 nos. solenoid valves along with Manual Option Foot Operated mechanism/ Foot switch. Anti-splash metal body construction made of Stainless Steel Grade 304 polished finished. The Scrub Sink is provided with front access panel for ease of maintenance and repairs. 1 – Position size 1600 mm long
SITC OF Hermetically Sealing type of Manual Sliding /Swing Door having thickness of 40-48mm of size 1500 X2100 mm single / dual leaf with PUF core sandwiched between Antimicrobial High Pressure laminates (HPL), with viewing window of size 300 X 300 mm. The door leafs hung on extruded heavy duty aluminium alloy extrusion Doorframe for single side swing Doors, Sliding Door leafs runs on (nylon wheels) within an extruded heavy duty aluminium alloy extrusion track / frames, for smooth effortless sliding with the help of handle.
SITC OF Writing Board (Size 950 mm x 650 mm) Flush mounted with wall panel surface
Supply & Insallation of Staorage Unit (3.5 H X 2 D X 15 W)
Supply & Insallation of Shoe Rack (4 H X 1.5 D X 4 W)
Supply & Insallation of Nursing Station with Back Storage
Providing and supplying center pivot, revolving, Mid back chair Depth-45cm, width-50cm, height- 105cm to 115cm & seat height- 45cm to 55cm. (+/- 2cm ) with five legged metal / moulded nylon base with push back arrangement. Chairs shall have high density moulded, 360 revolving on suitable base, gas lift , heavy duty twin wheel castors to take min 80 kg/castor with two - pneumatic height adjustment one piece moulded type polypropylene armrest etc. complete. The chair shall be provided with approved tapestry upto Rs 300/m with necessary beading wherever required. All metal work shall be Epoxy Polyster Powder Coated and as directed by Architect in charge. The over all appearance of the product shall be as per photograph. All metal work shall be Epoxy Polyster Powder Coated and as directed by Architect in charge.
Supply & Insallation of Signages
Design & Planning of main enterence area with allied ACP work
Supply & Inst of Main Board with provision LED Light
SITC of Medical Isolation Panel
Supply & inst of Modular Curtain track system with Fire retardent Curtain Set
SITC of Medical Grade Copper Tube/Pipes including all type of accessories Like,Tee, Elbow, Valves, etc. complete_Copper Pipes of 12mm OD x 0.7mm thk
SITC of Medical Grade Copper Tube/Pipes including all type of accessories Like,Tee, Elbow, Valves, etc. complete_Copper Pipes of 15mm OD x 1.0mm thk
SITC of Medical Grade Copper Tube/Pipes including all type of accessories Like,Tee, Elbow, Valves, etc. complete_Copper Pipes of 22mm OD x 1.0mm thk
SITC of Medical Grade Copper Tube/Pipes including all type of accessories Like,Tee, Elbow, Valves, etc. complete_Copper Pipes of 28mm OD x 1.0mm thk
SITC of Medical Grade Copper Tube/Pipes including all type of accessories Like,Tee, Elbow, Valves, etc. complete_Copper Pipes of 54mm OD x 1.2mm thk
SITC of Medical Gas Terminal Units (Gas Outlets) for Oxygen : It should fully complies and meets with the requirements of the UK DOH Health Technical Memorandum 02-01 (HTM 02-01) standards only. It shall be duly CE marked to the Medical Device Directive 93/42/EEC under the auspices of notified body no. and under this directive, med gas products are classified as Class IIb Medical Devices.
SITC of Medical Gas Terminal Units (Gas Outlets) for MA4 Air 4 Bar :It should fully complies and meets with the requirements of the UK DOH Health Technical Memorandum 02-01 (HTM 02 01) standards only. It shall be duly CE marked to the Medical Device Directive 93/42/EEC under the auspices of notified body no. and under this directive, med gas products are classified as Class IIb Medical Devices.
SITC of Medical Gas Terminal Units (Gas Outlets) for Vacuum :It should fully complies and meets with the requirements of the UK DOH Health Technical Memorandum 02-01 (HTM 02-01) standards only. It shall be duly CE marked to the Medical Device Directive 93/42/EEC under the auspices of notified body no. and under this directive, med gas products are classified as Class IIb Medical Devices.
SITC of Oxygen Flow Meter 0-15lpm :It shall fully comply and meets with active medical device of class IIa and in compliance with the EN ISO 15002: 2008 standard. It should be duly CE marked and comply with 93/42/EEC Medical Devices: General. It shall be CE marked with the notified body number specified. The flow meters should be of 0-15 LPM range for oxygen and with inlet pressure 50-60psi. (4.5 bar).
SITC of Humidifier Bottle : Polypropleyene or Polysulphone 250cc Humidifier bottle should be unbreakable, reusable to disinfectants and complements.
SITC of Polysulphone Vacuum Collection Jar 1000ml with lid
SITC of Adaptor for connecting with oxygen flow meter
SITC of Stainless Steel Ventilator Probe for Medical Air/ Surgical Air
SITC of adapter for connecting with vacuum regulator
SITC of 2 Gases Valve Box with pressure guage only for Oxygen & Vacuum. It Should fully complies with NFPA-99 standards or CGA standards. It should have zone valve box shall consist of the following components: A steel valve box which can house two to seven shut-off ball valves with tube extensions, an aluminum frame and a pull-out removable window. Pressure Gauges are included. The window shall be marked to prohibit unauthorized persons from tampering with the valves with the following silk-screen caution: “MEDICAL GAS CONTROL VALVES CLOSE ONLY IN EMERGENCY”
SITC of 3 Gases Valve Box with pressure guage only for Oxygen, MA4 & Vacuum. It Should fully complies with NFPA-99 standards or CGA standards. It should have zone valve box shall consist of the following components: A steel valve box which can house two to seven shut-off ball valves with tube extensions, an aluminum frame and a pull-out removable window. Pressure Gauges are included. The window shall be marked to prohibit unauthorized persons from tampering with the valves with the following silk-screen caution: “MEDICAL GAS CONTROL VALVES CLOSE ONLY IN EMERGENCY”
SITC of 15 mm Single Port Ball Valve with Pipe line assembly (pre piped) : It should comply with NFPA 99 standards. Pre Piped Degreased Ball Valve with pipe extension. It should be full-port design.It should be blow-out proof stem. It should be lockable valve.
SITC of 22mm Single Port Ball Valve with Pipe line assembly (pre piped) : It should comply with NFPA 99 standards. Pre Piped Degreased Ball Valve with pipe extension. It should be full-port design.It should be blow-out proof stem. It should be lockable valve.
SITC of 28mm Single Port Ball Valve with Pipe line assembly (pre piped) : It should comply with NFPA 99 standards. Pre Piped Degreased Ball Valve with pipe extension. It should be full-port design.It should be blow-out proof stem. It should be lockable valve.
SITC of Digital Area Alarm (2 Services : Oxygen and Vacuum) with pressure sensor : It should fully comply and meet with NFPA-99 and It must be UL Listed with UL certificate must be submitted. Medical Gas LCD Alarm : It should comply with NFPA 99, CSA Z7396.1 and CSA Z305.1. It should be UL or ETL Listed. The LCD alarm shall be microprocessor based with a 10" (25.4 cm) screen and capable of monitoring medical gases.
SITC of Digital Area Alarm (3 Services : Oxygen, MA4 Air and Vacuum) with pressure sensor : It should fully comply and meet with NFPA-99 and It must be UL Listed with UL certificate must be submitted. Medical Gas LCD Alarm : It should comply with NFPA 99, CSA Z7396.1 and CSA Z305.1. It should be UL or ETL Listed. The LCD alarm shall be microprocessor based with a 10" (25.4 cm) screen and capable of monitoring medical gases.
SITC of Medical Gas Rubber tubing color coded throughout their length. All hoses shall incorporate an anti- static inner core (For All Gases)
SITC of Double duct Bed Head Horizontal Wall Panel 600 mm. Separete duct for gas outet and seperate duct for electricals. (made up from Aluminum powder coated profiles) with double duct. Separate duct for electrical sockets and separate duct for gas outlet points. Each bed head panel should be pre piped and pre wired. It should have pre wired 4 nos. electrical sockets in separate duct ( 2 nos. 5 A sockets and 2 nos. 15 A sockets). Gas outlet points 2nos. pre piped to be fitted in the bed head panel. Gas outlet points cost not to be included in the bed head panel cost since it is separate line item. It should have provision for RJ45 connector and Nurse call system bedside switch with partition between LV and ELV system.
SITC of double duct Bed Vertical wall Head panel (Approx Size1200 mm ).
Supply & Inst of Panel mounted vesa type monitor stand
Supply & Inst of SS 304 Basket with mounting bracket as per specification
Supply & Inst of Vacuum unit mounting bracket
Supply & Inst of Panel mounted IV Hanger unit with multiple hook
Supply & Inst of File holder for patient Bed
SITC of Vacuum Pump. : It should be oil lubricated rotary vane vacuum pump, having each vacuum pump capacity of 3000lpm with IEC Motor rating of minimum 10 HP @ 50 Hz or above. Vacuum pump shall comprise of air cooled, oil lubricated vacuum pumps suitable for both continuous and frequent start / stop operation at inlet vacuum vessels between 525mm Hg and 700 mm Hg. The ultimate vacuum of pump shall be 0.1 mbar with gas ballast valve closed.
SITC of Vacuum Filter (Bacteria Filter) of 50scfm to 60scfm – 3” Filter housing with drain flask: It fully complies and meets with requirements of UK HTM medical standards. It should have BS 3928 sodium flame test certificate based on requirements of HTM standards.The bacteria filter should be designed for critical application involving removal of dry and wet dust, particulars, oil aerosol and water droplets, high efficiency glass fiber, fieece media from suction side of vacuum pump system. It should have efficiency of at least 99.995% when tested by sodium flame test and that should be according to BS 3928:1969.
SITC of Vacuum Receiver Tank of 1500 Litres water capacity
SITC of Electrical Control Panel for Vacuum pumps with time totalizer and phase preveneter and cascading
SITC of Electrical wiring inside plant room only for interconnection of vacuum pumps and air compressors (*Hospital will provide 3 phase & single phase power supply with cable inside the gas manifold and plant room. Hospital will provide DG back up and phase preventer + Isolation Transformer. Hospital will provide all electrical fixtures like exahust fan, light, power sockets inside gas manifold and plant room)
SITC of Oil Free Rotary screw/Scroll/Reciprocating Air Compressor : Oil free Rotary Screw/scroll/Reciprocating air compressor.It should be 50Hz, 3 Phase, 440volts. 11 Bar, 116 Psig. 50/60cfm or more at 11 Bar. 11 Kw & 15 Hp. The 30/40 cfm flow capacity for each compressor unit having suitable motor rating of Rotary Screw/scroll air cooled compressor. Compressors shall be oil free Rotary Screw/scroll/Reciprocating compressors suitable for both continuous and frequent start/stop operation at a nominal outlet pressure of 800 kPa (8compressors suitable for both continuous and frequentcompressors suitable for both continuous and frequent bar). The air quality shall be 100% oil free, certified ISO8573-1.The compressor shall have a sound insulating enclosure.
SITC of 100cfm Heatless Air Dryer : 100cfm Heatless Air Dryer : It should have air dryer desiccant type with ½” end BSP connection. It should have pre filter and post filter. It should be designed for ISO:7183- 1986 (E) standards. It should have dryer quality class -ISO 8573-1 standards. It should be made of aluminum construction. It should have purge loss 15+/- 1%. Active and Regenerative tower
SITC of Coarse coalescing filter 1" of 50scfm to 60 scfm filter . It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have particle removal 1 micron. It should have maximum particle size class 2 micron as per ISO 8573-1: 2010 .
SITC of Activated Carbon Filter 1" of 50scfm to 60 scfm Filter. It should comply with air quality standard ISO 8573-1: 2010. It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have maximum particle size class 1 micron as per ISO 8573-1: 2010 . It should have maximum oil content 1 micron ISO 8573-1: 2010.
SITC of Fine Dust Filter 1" of 50scfm to 60 scfm. It should comply with air quality standard ISO 8573-1: 2010. It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have pipe size connection 1” = 105scfm and 144nm3/hr.It should have particle removal 0.01 micron. (Maximum tolearance allowed will be only 15%).
SITC of Air Receiver Tank of 1500 Litres water capacity
SITC of Pressure Reducing Station from 11 bar to 4 bar (for MA4 Air) and 7 bar (for SA7 air)
SITC of Electrical Control Panel for Air Compressors with time totalizer and phase preveneter and cascading
SITC of Internal Electrical Work, Fan Tube Light Exaust fan Etc And Main Cable form Panel
PCC work 700 Sq ft
Core cutting of the slab for allowing pipe to lay with PVC guard pipe on each floor for Slab
Re-Installation of weather shed along with MS structure
MS structure for AC works
Supply, Installation, testing & commissioning of addressable 2 loop main fire alarm electronic control panel, expendable up to 4 loop & having maximum 250 devices (any combination detectors plus devices) per loop & Audio/ Visual alarm complete as per IS: 2189 specification - modular type front operated with interlocking door arrangement totally enclosed dust and vermin proof for indoor type applications.
Supply, Installation, testing & commissioning of expandable Loop card for main fire alarm electronic control panel, shall support 254 devices both detectors and modules and shall support both class 'A' & class 'B' wiring.
Supply, Installation, testing & commissioning of Intelligent Photoelectric Smoke Detector along with mounting box & termination glands.
Supply, Installation, testing & commissioning of Addressable Manual call point/ station with mounting back box
Supply, Installation, testing & commissioning of Programmable Electronic Sounders (Hooters):
Supply, Installation, testing & commissioning of remote response indicator
Supply, Installation, testing & commissioning of 2Cx1.5 sq.mm armoured RED color copper FRLS cable with necessary saddles, screws, junction boxes, sleeves, elbows couplings etc. for Fire alarm System
Cable End Termination For Copper Cables – 2C x 1.5 / 2.5 Sq.mm
100mm x 100mm x 50mm size GI Junction box with kNosck out & 10Amp. Connector block /strip
Clean Agent Fire Extinguiser
Attharva Health Tech India Pvt. Ltd. (BID ID -6344042)
Sahora Corporation (BID ID -6343986)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .