| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.4 CrAccepted-AOC | ₹8.4 Cr Quoted ₹8.5 Cr | 1 | Accepted-AOC Being lowest and reasonable |
| 2 | 2₹9.4 Cr+₹86.0 L (10.1%)Rejected-Finance | ₹9.4 Cr+₹86.0 L (10.1%) | 2 | Rejected-Finance Not being lowest |
| 3 | 3₹9.8 Cr+₹1.3 Cr (15.7%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹9.8 Cr+₹1.3 Cr (15.7%) | 3 | Rejected-Finance Not being lowest |
| 4 | 4₹10.5 Cr+₹2.0 Cr (23.7%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹10.5 Cr+₹2.0 Cr (23.7%) | 4 | Rejected-Finance Not being lowest |
| 5 | 5₹11.4 Cr+₹2.9 Cr (34.7%)Rejected-Finance 2ND FLOOR 9 EZRA STREET KOLKATA WEST BENGAL 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹11.4 Cr+₹2.9 Cr (34.7%) | 5 | Rejected-Finance Not being lowest |
Tender Value
₹10.9 Cr
EMD Value
₹8.7 L
Closing Date
2 Jan 2020, 6:00 pmClosed
CE (AF) SHILLONG ZONE
HQ CE (AF) SHILLONG ZONE, ELEPHANT FALLS CAMP, PO-NONGLYER, SHILLONG-793009
AUGMENTATION OF ELECTRICAL SUPPLY TO 33 KV FEEDER ALONGWITH ASSOCIATED INFRASTRUCTURE AT AF STN DINJAN UNDER GE (AF) MOHANBARI
2019_MES_292872_1
88624/DIN/E8
Open Tender
Civil Works
Lump-sum
365 days
Dinjan
As per tender documents
7 documents required · 7 mandatory
₹3,000
GE (AF) Mohanbari
₹8.7 L
Yes
HQ CE (AF) SHILLONG ZONE
30 Apr 2020
25 Oct 2019
7 Jan 2020
25 Oct 2019
2 Jan 2020
2 Dec 2019
28 Oct 2019 - 20 Nov 2019
5 Nov 2019
Amount
SCHEDULE "A" Part - I (BUILDING / STRUCTURE) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.
Construction of Sub Station Building complete all as specified and as shown on drawings
Construction of Shed for DG Set complete all as specified and as shown on drawings.
SCHEDULE "A" PART-II (SITE CLEARANCE, EARTH WORK AND EXCAVATION ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-X (LIGHTENING ARRESTOR / LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XI (FENCING & GATE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (FIRE EXTINGUISHER SHED) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (CABLE DUCT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XIV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' 5 ' signifies this fact only.
Supply & fixing surface/wall mounted light fitting in CRCA powder coated white housing with pre-wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 20 Watt,1200mm Long with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of suitable size complete all as specified and directed. Make - Havells Cat Part No-LHEYBYP70E1W020 or equivalent as approved.
S&F LED lamp 15 Watt all as specified and directed. Make- Havells cat part No-LHLDEBHEMD8Z015 or equivalent as approved.
S&F LED security light fitting 1 X 25 Watt with integral reflector made of alluminium alloy LM6, with LED driver etc and all accessories pre-wired and making connection with three core PVC insulated, sheathed copper conductor cable of suitable size complete with bracket made of 40mm dia light grade pipe 1.2 mtr long, all as specified and directed. Make-Havells Cat Part No-ENDURAPEARLSL25WLED757SASYTOPC or equivalent as approved.
Supply & fixing ceiling fan of size 1200 mm sweep, conforming to IS : 374, 5 Star rated, nominal wattage -50 Watt (± 5 %) , speed - 320 to 380 RPM, Air delivery - 215 to 225 Cu Mtr/Min including accessories complete suitable for operating voltage 230 Volt AC connecting with FR PVC insulated & PVC sheathed round flexible copper conductor wire of size not less than 23/0.0076 in three core of length not more than 0.5 Mtr and marking MES no as directed with super enamelled paint including testing complete in all respect as specified and directed. Model - ES 50 Premium of Havells or equivalent as approved.
Supply & fixing ventilating fan in powder coated metallic body of size 300 mm sweep, speed - 1400 RPM, Air delivery -1850 CuM/Hr, Noise level - 40 to 45 db, rated voltage - 230 Volt AC having double ball bearing with fixing MS louver of suitable size including making connections with short length of PVC insulated, sheathed copper conductor wire of size 0.5 Sqmm complete all as specified and directed. Model No - Ventil Air DB of Havells or equivalent as approved.
S&F Factory made sheet metal enclosure for MCB DBs, Manufactured prewired double door designed, DB's TPN 4 way IP-43, fixed on wall/MS box complete with copper bus bar neutral link din rail suitable for mounting MCB's/MCCB's complete, incl MCCB TPN 125Amp, 16 kA, all as specified and directed. Make: Legrand Cat No-507740 DPX 160+12 or equivalent as approved
S&F Factory made sheet metal enclosure for MCB DBs, Manufactured prewired double door designed, DB's TPN 4 way IP-43, fixed on wall/MS box complete with copper bus bar neutral link din rail suitable for mounting MCB's/MCCB's complete, incl MCCB TPN 63 Amp, 16 kA, all as specified and directed. Make: Legrand Cat No-507740 DPX 160+12 or equivalent as approved
S&F MCB single pole, 6 to 32 amps rating, 240 volts, 'B' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB Triple Pole & Neutral, 63 Amps rating, 440 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
M&L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL, Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover reinforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-I and connected to the earth point and testing complete all as specified and directed.
S&F blanking plate for MCB DB.
Material & Labour 200mm thick (compacted thickness) Wet Mix Macadam (WMM) in two layers each layer 100mm thick compacted separately with crushed stone aggregate of specified grading (63mm to 40mm size), rolled and consolidated using power roller exc 8 tonne but n. exc 12 tonne as specified to required gradient and camber complete all as specified and as directed.
Supply, installation, testing and commissioning transformer outdoor type capacity 2500 KVA, 3 phase 50 Hz double wound with copper winding in mild steel tank as per IS - 2026, 33 KV /11 KV (Max incoming voltage withstand capacity 36 KV) with tapping (-)10% to (+) 10% in steps of 1.25% (total 17 steps) windings on circuit, vector group DYN-11 mounted on PCC plate form with on load tap changers, tapping terminal arrangement, initial filling of transformer oil and making connection from cable end box both side at 11KV with 8 SWG copper wire covered with PVC sleeves including under mentioned accessories including all control cables & panels complete all as specified and directed :- (Transformer for Main Receiving Station) (a) HT Bushing 33 KV side (b) Cable box LV (11KV) side. (c) Lifting lungs (d) Oil conservator tank(1+1=2 Nos) one for OLTC) (e) Top filter vale. (f) Silica gel breather- 1 Nos (g) Drain valve- 1 No (h) Marshalling box. (j) Buchholtz relay with one set of contracts for alarm and trip and two shut off valve for OLTC (k) Double float bucchotlz relay with alarm/trip contracts for main tank-1 No including control cable copper conductor of suitable size and length from relay to VCB. (l) Explosion ventilator-1 No (m) Earthing terminals- 2 Nos (n) Air release plug -01 No (o) Base channels (p) Plain oil level gauge.
Srl Item No. 13.13 (Contd...) (q) Dial type oil temperature indicator with one set of contacts for alarm and trip. (r) Dial type winding temperature with one set of contacts for alarm and trip (s) RTCC panel with AVR and oil surge relay with master following logic. (t) ON load tap changer complete with control panel control cable from tap changer to remote panel of required length and size. (u) No load HV volt-33000 (v) No load LV volt-11000 (w) Full load current HV-43.74 A (x) Full load current LV-131.2 A (y) Type of cooling-ONAN (z) Impendence voltage-6.56% (aa) Connection-Delta (bb) Insulation level L I-170 AC-70/Li-75 Ac-28 or as per OEM specifications. (cc) Max Temp rise in oil 50° C by resistance (dd) Turn ratio +5% to 15% @1.25% (ee) Plinth of Size 3.5X3.5X1.0m above GL & 0.6 m below the GL for installation of transformer & the rates of plinth including in the rate of transformer. (ff) Suitable control cables from yard to transformer control panel.
Supply, install, Factory testing and commissioning of transformer step down for MRS, copper wounded having primary side for HT Three Phase 33 KV & secondary for 3 phase 433 Volts, 4 wire 50 hertzs capacity of 100 KVA as per IS-1180 Part-I, Level-III with the following specification :- (i) No load voltage ratio-33/.433 KV, (ii) Nos of phase-three (iii) Type of cooling- ONAN, (iv) Frequency-50 Hz (v) Vector group-DYN 11, (vi) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing (vii) Oil level gauge indicating oil level minimum and maximum (viii) Lifting lugs (ix) Rating and terminal marking plates (x) Dehydrating breathing device which would not permit ingress of moisture, rain water and insects (xi) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug (xii) Thermometer pocket (for transformers of rating above 25 KVA) (xiii) Oil filling hole( 1-1/4" Nominal size thread) with cover (transformers with conservator) (xiv) Connection-Delta/Star (xv) Temperature rise in oil-45 deg celcius (xvi) Temperature rise in windings- 55 deg Celsius (xvii) Material winding-Copper wound (xviii) High voltage/low voltage both with cable box (xix) Service-Outdoor type (xx) Neutral- Internally connected with earthing lead and bush (xxi) On load tap changing (+- 7.5% in step of +- 2.5%) (xxii) Transformer losses as mention Energy conservation building code (ECBC-2008) all as specified (xxiii) Suitable platform of 2.0x2.0mx1.0m above GL & 0.6 m below ground level for installation of transformer. (Rates of plinth including in the rate of transformer) (Station Transformer)
Supply, install, Factory testing and commissioning of outdoor type transformer step down for Substation-C, copper wounded having primary side for HT Three Phase 11 KV & secondary for 3 phase 433 Volts, 4 wire 50 hertz capacity of 630 KVA as per IS-1180 Part-I Level-III with the following specification :- (i) No load voltage ratio-11/.433 KV, (ii) Nos of phase-three (iii) Type of cooling- ONAN, (iv) Frequency-50 Hz (v) Vector group-DYN 11, (vi) Two earthing terminals for body earthing and two additional for neutral (vii) Oil level gauge indicating oil level minimum and maximum (viii) Lifting lugs (ix) Rating and terminal marking plates (x) Dehydrating breathing device which would not permit ingress of moisture, rain water and insects (xi) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug (xii) Thermometer pocket (for transformers of rating above 25 KVA) (xiii) Oil filling hole( 1-1/4" Nominal size thread) with cover (transformers with conservator) (xiv) Connection-Delta/Star (xv) Temperature rise in oil-40 deg Celsius (xvi) Temperature rise in windings- 45 deg Celsius (xvii) Material winding-Copper wound (xviii) HT side HT bushing, LT side with cable box. (xix) Service outdoor type (xx) Neutral- Internally connected with earthing lead and bush (xxi) On load tap changer (+5% in step of -15%) with 16 steps/7 positions. (xxii) Suitable platform of size 2.0x2.0mx1.0m above GL & 0.6 m below ground level. Rate quoted shall be inclusive of suitable size of plinth for transformer. (NOTE :- Qty-01 Transformer of 630 KVA for SUB STATION 'C' considered in place of existing 250 KVA at s/s 'C'. The 250 KVA transformer to be reused as spare to AF Dinjan STN.
Material and labour for fabrication of trolley of 3.10mX2.3mX1.8m with suitable rubber tyre 04 Nos heavy duty for moving anywhere 250 KVA Electric Transformer as standby and tow chain arrangement to accommodate one existing 250 KVA transformer ( S/S 'C) using MS channel of size 100 x 50 mm and angle iron 50 x 50 x 6 mm and MS flat wherever required including base of MS sheet 10 gauge fixed properly welded on chassis including fencing all around with MS angle iron 40 x 40 x 6 mm and MS flat 40 x 6 mm with XPM mesh, cage not less than 1.80 mtr high cage. Transformer to be fixed on trolley with suitable size of nut & bolts.
Supply, laying & testing of HT Cable of size 240 Sqmm 3 Core XLPE insulated galvanised steel strip armoured electric power cable (earthed) with aluminium conductor 33000 volt complete all as specified and directed.
Supply and fix HT cable jointing kit for 33 KV grade cable for outdoor end termination type cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size of 240 Sqmm complete all as specified and directed.
Supply and fix HT cable jointing kit for 33 KV grade cable for indoor end termination type cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size of 240 Sqmm complete all as specified and directed.
Supply and fix HT 33 KV outdoor horizontal gang operated air-break off load isolating switch, triple pole, each pole consisting galvanized steel base, HT insulators as per B.S.S/I.S having non ferrous knife and spring loaded contacts, arcing horns of adequate section to break magnetizing current of the transformer, phase separation, adequate length of GI pipe for operation of ground level and operating handle complete in both OFF and on position.
Supply and fix outdoor expulsion type drop out fuse with double stack of insulators mounted on channel base for 33 KV Line.
Supply, installation, testing and commissioning lighting arrester HT 33 KV (RMS) of rating 65 KA of station class.
Supply, installation, testing and commissioning lighting arrester HT 11 KV (RMS) of rating 65 KA of station class.
Supply, installation, testing and commissioning 33 KV Current Transformer oil cooled outdoor single phase of ratio 100/5-5Amps class 1.0-5P10,burdon 15VA insulation level 70KV/170KV including all accessories with suitable copper control cable.
Supply, installation, testing and commissioning 33 KV single phase outdoor Potential Transformer oil cooled 33KV/rt 3/110Vrt 3/rt 3Classo.5-3,Burdon 50 VA-50VA. Insulation level 28/75KV,voltage factor 1.2 Cont and 1.9 for 30 Sec, conforming to IS-3156 including all accessories with suitable copper control cable.
Supplying, installation, testing and commissioning of RMU 4 way extendible HT 11 KV outdoor type 21KA for 3 sec, rated voltage-12V, operation voltage 11 KV, rated lightening withstand voltage-75KV, rated frequency 50Hz, 630 amp copper bus bar, SF6 insulated compact switch gear, welded stainless steel enclosure with minimum 2.5 mm thickness, totally enclosed Ring Main Unit IP-67 protection for SF6 Tank and IP 55 protection for outdoor enclosure with self powered microprocessor based complete numerical over current & earth fault relay with specification/equipment with power backup 24 volts DC complete with all accessories comprising of following (VVCC+M configuration of ABB or equivalent as specified in PS):- (a) Fixed motorised Vacuum circuit breaker (VCB) , SF6 gas insulated- 02 (two) No Vacuum circuit breaker unit insulated in SF6 media as per latest IEC 62271-200 shall be comprising of the following for each set:- (i) Assembly of VCB interrupter complete with epoxy support insulator and self aligning isolating contacts with rating 11 KV, 630 Amp, 21 KA for 3 sec, 50 Hz. (ii) Manual charged and manual operated independent closing/tripping, trip free operating mechanism and breaker closed/open spring charged/discharge indication. (iii) Mechanical operation counter- 01 No (iv) One bus bar chamber including a set of 3 phase 630 Amps copper bus bar. (v) Strip heater 230 volts AC single phase 80 watt. (vi) 3 0/C + 1 E/F self powered numerical protection relay with low and high set for over current and earth fault. Relay should have facility to display the maximum loaded phase current also. Relay shall record minimum 5 fault record with time stamping. (vii) One No potential transformer (PT) three phase, dry type(resin cast) draw out type 11 KV/110 volts, 25 VA burden, accuracy class 0.5 with HT & LT HRC fuses for primary and secondary complete as per conforming to IS-3156-01. (viii) Current transformer chamber comprising of 3 Nos single phase resin cast CTs of 100-50/5 and accuracy class 0.5 for metering and class 5P 10 for protection, burden 2.5 VA in VCB feeder- set of 3. (ix) Digital SCADA compatible(for future integration) intelligent panel meter indicating line/phase current, line/phase voltage, power factor, KVAR, KVA, frequency etc with accuracy class 0.5 – 1 No. (b) Fixed motorised load break switches (LBS)- 02 (two) Nos (Loc- At Proposed ATC & Substation-D)
Supplying, installation, testing and commissioning of RMU 4 way extendible HT 11 KV outdoor type 21KA for 3 sec, rated voltage-12V, operation voltage 11 KV, rated lightening withstand voltage-75KV, rated frequency 50Hz, 630 amp copper bus bar, SF6 insulated compact switch gear, welded stainless steel enclosure with minimum 2.5 mm thickness, totally enclosed Ring Main Unit IP-67 protection for SF6 Tank and IP 55 protection for outdoor enclosure with self powered microprocessor based complete numerical over current & earth fault relay with specification/equipment with power backup 24 volts DC complete with all accessories comprising of following (VVCC+M configuration of ABB or equivalent as specified in PS):- (a) Fixed motorised load break switches (LBS)- 02 (two) Nos, (b) Fixed fuse module - 02 (Two) Nos. consisting of switch fuse combination modules 12KV , 200 A within three position load break switch and earthing switch, fuse canister, fuse tripping, busbar, interlocking, bushing for cable connection in front , earth bar and stored spring energy.(Fuse rating shall be as per transformer capacity) (Loc : Existing P-3,P-6,P-8,P-10, 34 Airmen mess)
Supply, fixing, connecting hollow aluminium bus tube of 40 mm nominal dia for 33 KV operating voltage and of current carrying capacity 400 Amps including necessary connections with electrical equipment/ system by means of bolts, nuts, check nuts, washers clamps , expansion joints and painting with insulated paint of R.Y.B colour coding etc and testing complete.
Supply, fixing, hot dip galvanised, cross arms, bracings, supports, clamps and back plates, fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint including all fixing accessories (Note : for making structure Pole CTs, PTs, VCBs at proposed MRS or as required at site.)
Supply, fixing and testing post top insulator in three series including necessary connection with 33 KV distribution system complete all as specified. Note : Each insulator of 3 series shall be of 33 KV rating.
Supply, fixing and testing disc type insulator in three series including necessary connection with 33 KV distribution system complete all as specified. Note : Each insulator of 3 series shall be of 33 KV rating.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized strip of 32X6 mm earth lead by means of nuts bolts check nuts GI washers protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR part 1 including testing on completion all as specified and directed. incl demolition to existing one complete.
Material and labour for earthing complete with copper plate electrodes of size 600mm x 600mm x 3.15 mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to Copper strip of 30X6 mm earth lead by means of nuts bolts check nuts copper washers protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR part 1 including testing on completion all as specified and directed. incl demolition to existing one complete.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized earth lead wire of 4 mm dia earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSr part 1 including testing on completion all as specified and directed. incl demolition to existing one complete.
Supply & fixing Flood light fitting LED type capacity 70 W pressure die-cast aluminium housing with IP-66 degree of protection with innovative thermal management.
Supply & fixing Flood light fitting LED type capacity 200 W pressure die-cast aluminium housing with IP-66 degree of protection with innovative thermal management.
Supply and fix LED post top lantern light fitting for 25 Watt complete With all accessories.
Supply , install, testing and commissioning of floor mounted LT indoor panel board AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accommodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type, suitable for indoor use, with bottom cable entry with suitable cable glands structure made out of 2.00 mm thick with CRCA steel sheet of suitable size with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete all as specified and directed :- (For MRS Bldg & Yard Lighting) BUSBAR :- (i) Aluminium bus bar 300 Amps, supported on non hygroscopic fibres and brass screws for mounting -04 Nos INCOMER (a) Supply and fixing MCCB 4 pole 415 Volts with microprocessor controller of breaking capacity of 50 KA of 200 Amps with Fixed thermal and Fixed magnetic setting- 01 Nos INDICATING DEVICES (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos (b ) Supply and fixing Digital Ampere Meter of size 100mmX100mm for 0-300 A display , incl CT having CTR 200/5 - 01 Nos & Digital Voltmeter 0-500 Volts , SIF 96 - 01 Nos OUTGOING FEEDERS (a) Supply and fixing MCCB of 4 pole , 415volts of capacity 125 amps with breaking capacity of 16 KA Fixed thermal and fixed magnetic setting - 01 No (For MRS Bldg. ) (b) Supply and fixing MCCB of 4 pole , 415volts of capacity 63 amps with breaking capacity of 16 KA Fixed thermal and fixed magnetic setting - 01 No (For security light ) (c) Supply and fixing MCCB of 4 pole , 415volts of capacity 63 amps with breaking capacity of 16 KA Fixed thermal and fixed magnetic setting - 01 No (For High Mast light ) (c) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure - 02 No
Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 80 KW (100 KVA), water cooled, 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB-II guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection ,multi cylinders ,four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving 50 BHP to drive Alternator capable of delivering 100 KVA(80 KW) at , 12 volt 180 Ah battery for auto start(as per manufacturer recommendations) complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system with electronic governor and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc and self starting system incl batteries etc complete. (ii)Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 100 KVA/ 80 KW, Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through dynamically balanced flexible coupling with and to match the above engine. (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications. (v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M (vi) Diesel storage tank of capacity 180 Ltrs for storage of diesel for 12 hours operation of Gen Set. (vii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.
Supply only MS fire bucket 13 Litre capacity, painted red, filled with sand, with carrying handle in bottom of bucket confirming to IS : 2546 complete as specified and directed.
M&L for the following items:- (a)Mechanical foam Extinguisher of capacity 9.0 Ltrs complete all as per (IS :15683)-02 Nos (b) Light weight Squeeze grip type CO2 Fire extinguisher 3KG capacity all as per(IS:16018)- 02 Nos (c ) Dry powder(ABC) type fire extinguisher of capacity 6.0 Kgs all as per (IS:15683)-02 Nos. complete.
Boring of holes suitable for insert 250 mm dia Hume Pipe under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine.
Dismantling existing HT Steel/Iron Poles from any place/area and any height including connected items like gang operating device, DO fuse, channels and all other accessories complete. (NOTE :- Quoted rate is inclusive of all earthwork required for dismantling of the poles and making good surface.)
Dismantling existing HT RCC Poles from any place/area and any height including connected items like gang operating device, DO fuse, channels and all other accessories complete. (NOTE :- Quoted rate is inclusive of all earthwork required for dismantling of the poles. and making good surface.)
Dismantling existing 11 KV VCB Qty-01 Set (at S/S 'B') having 3 VCBs Panel alongwith its connected equipments Complete. (NOTE :- Quoted rate is inclusive of all earthwork required for dismantling of the and making good surface.)
Dismantling existing 11 KV RMU SF6 Qty-01 Set (at S/S 'E') Panel alongwith its connected equipments Complete. (NOTE :- Quoted rate is of all earthwork required for dismantling of the and making good surface.)
Taking down/out unserviceable or serviceable existing LT/HT UG cables of any cross sectional area, 3 core and connections including Bricks, GI Pipes etc of any descriptions, laid in trenches and/or fixing with walls/poles including segregating of serviceable materials viz bricks/PCC cable, cables, GI Pipes etc, complete all as specified and as directed. (NOTE : quoted rate deemed tobe included all earth work as excavation, removal and returning/filling).
Supply and fix cable route indicator for HT cables made out of mild steel of any size .
Supply, fixing and testing of Early Streamer Emission (ESE) type lightening arrestor Level 4 having Radius of Protection 89 mtrs with wheather proof encloser as per NFC 17-102- 2011 having base plate and GI mast of 4.5 mtrs, ESE Flange and Lightning Arrester Accessories, copper strip of 20 mm X 3 mm about 10 m length and Copper Bonded Rod 17.2 mm Dia 2 mtrs long with U Bolt Clamp, Earthing Compound Carbolite 25 Kg Bag, Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber - 3 Ton Capacity.
S&F 15 mm bore angle stop cock brass CP high pressure with capstan head, long shank screwed down complete all as specified and directed.
S&F Elastomer electric insulating mat (Non skid type) class 'B' 2.50mm thick suitable for 11KV rating installations all as per IS: 15652-2006. Make: JB/Safe Volt/Jyoti.
Manning & Operation of 33/11 KV main receiving installation comprising of HT control relay panel 33 & 11 KV, HT VCB Panel alongwith Transformer 2500 KVA - 02 Nos, GOD & DO fuse, CT, PT, Station Transformer, DG Set, LT Panel etc., fixing of burnt out HT/LT Fuse, all cables & joints alongwith all connected accessories including entering and maintenance of electrical reading of main incoming & outgoing feeder voltage, Ampere, power factor details etc. on hourly basis, ASEB breakdowns/load shedding/shutdown, MES breakdown/load shedding/shutdown in Register/documents, lodging electric complaint on phone and cleaning of complete yard/installation in all respects round the clock for 24 hours 3 shift per day including sunday and holiday, complete all as specified and directed by Engineer-in-Charge from time to time. (01 Skilled Electrician and 01 Helpers for each shift). Note :- 1. Manning and operation shall be operative for 24 months from certified date of completion of main work. 2. Funds for manning shall be met from maintenance Code Head (52/761/05). 3. Final bill shall be processed only after completion of Manning & Operation work.
SCHEDULE "A" PART-XV (SCHEDULE OF CREDIT) Note :- Amount of Rs. 819735.00 indicated in Tender as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
M/s JAIMAA ASSOCIATES
FRIZO INDIA PVT LTD
Sant Construction Co.
surendra infrastructure pvt ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .