Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹46.7 L+₹28,068.33 (0.60%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹48.8 L+₹2.4 L (5.10%)Rejected-AOC FLAT NO 703 7TH FLOOR PARVATI ENCLAVE PLOT NO 180 SECTOR 2 TOLOJA PANCHANANDTAL TALOJA MAJKUR DISTT RAIGAD MAHARASHTRA 410208 | RAIGAD | MAHARASHTRA | 410208 | L3 | Rejected-AOC REJECTED |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
27 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW)BHNADUP
GE(NW)BHNADUP,MUMBAI
ADDN ALTN AND IMPROVEMENT TO CONFRENCE HALL, PLASTER TO NS-118 AT NSV, SPECIAL REPAIR TO SEWAGE LINE AT MOORA, ADDN/ALTN TO NS-42 AT NAVAL PARK, PROVN OF CLOTHING LINE, ADDN/ALTN TO DOORS AT NS 17, NS 97 AND PROVN OF HARD STANDING NEAR A ROAD AT MO M
2020_MES_408220_1
8898/B
Open Tender
Civil Works
Item Rate
180 days
GHATKOPAR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(NW)BHNADUP
₹98,000
Yes
11 May 2021
30 Dec 2020
28 Jan 2021
30 Dec 2020
27 Jan 2021
13 Jan 2021
60 days
Amount
M&L for Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and directed.
M&L for Plain Cement Concrete type D2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete.
M&L for RCC 1:2:4 (20 mm graded aggregate) as foundation, footing, plinth beam and base of column etc complete all as specified and directed.
M&L for RCC 1:2:4 (20 mm graded aggregate) as columns, pillars, piers, posts and struts etc complete all as specified and directed.
M&L for RCC 1:2:4 (20 mm graded aggregate) as beams, catilevers, lintels etc complete all as specified and directed.
M&L for RCC 1:2:4 (20 mm graded aggregate) as as wall and like any thickness, etc complete all as specified and directed.
M&L for RCC 1:2:4 (20 mm graded aggregate) as in slabs supported on walls,beams and chajjas etc complete all as specified and directed.
M&L for TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips,complete all as specified and directed.
M&L for TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as specified and directed.
M&L for Form work to side of concrete as in foundation,footing base of column and plinth beam rough finished of surfaces complete all as specified and directed complete all as specified and directed.
M&L for Form work to side of concrete as in pillars, posts, struts, piers, columns etc for fair finished of surfaces complete all as specified and directed complete all as specified and directed.
M&L for Form work to side of concrete as in roof beams, lintels cantilevers, shelves etc for fair finished of surfaces complete all as specified and directed.
M&L for Form work to soffits of suspended slab anding etc for fair finished of surfaces complete all as specified and directed.
M&L for Form work to edges of concrete as in windows cills, lintel etc for fair finished of surfaces complete all as specified and directed.
M&L for Form work to face of wall , parapet etc for fair finished of surfaces complete all as specified and directed.
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specifed and directed
M&L for rendering 10 mm thick in CM 1:6 on brick walls, RCC pillars, beams, purlins etc and finishing the surface even and smooth complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth complete all as specified and directed.
M/L for 15mm thick rendering in CM 1:4 in two coats (10+5) with water proofing compound incl. finishing the surface even and smooth without using extra cement. (WPC shall be measured and paid seperately)
Supply only integral water proofing compound.
M&L for applying two coats of distemper oil emulsion on wall over a coat of priming paint including preparation of new plastered or un-plastered surfaces of walls, complete all as specified and directed.
M&L for applying two coats of distemper oil emulsion on ceiling over a coat of priming paint including preparation of new plastered or un-plastered surfaces of ceiling, complete all as specified and directed.
M&L for preparation of surfaces of walls/ceiling including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots, washing down with water, filling of cracks with Dr fixit crack filler or equivalent make/ preparation of new plastered surface and applying two coats of Dr fixit rain coat paint over a coat of rain coat primerof approved shade ,including necessary scaffolding work etc complete all as specified and directed.
Returning filling in including spreading watering and well ramming in layer n.exc 25cm thick complete all as specified and directed.
Removal of surplus soil not exceeding 50 mtr from staring point and depositing to a point including spreading watering and well ramming in layer n.exc 15cm thick as directed.
Removing excavated soil to a distance exc 1.50 Km but n. exc 5.00 Km and depositing outside MD land complete all as specified and as directed by Engineer-in-Charge.
M&L for moorum/red bajri filling in floors or pavings laid in layers n exc 15cm thick spread levelled and blinded with earth and rammed incl watrering complete all as specified.
M&L for Hardcore of guage n exc 63mm of broken stone, deposited spread & leveled in layers n exc 15cm thk, watered & rammed to a true surface complete all as specified and directed.
M&L PCC 1:3:6 C-2 (using 20mm graded crushed stone aggregate) as in plinth protection, sub base of floor ( 75mm thick ) finished even and fair all as specified.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.06 sqm n exc 0.11 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 laying floor finished complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300x200mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:3 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
M&L for vitrified ceramic tiles 10mm (light shade of square/ rectangular) polished, area of each tiles not exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
S&F standard aluminium section powder coded in partition / frame and door shutter, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed (Aluminum section shall be of make Jindal / Hindalco / Indalco). Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment. Cost of other consumables required for the item shall be deemed to be included in the quoted rate. However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper only will be measured and paid separately under respective items as supply only. Fixing by element of these items shall be deemed to be included in quoted rate.
Supply only 4.80mm thick sheet plain glass, and glazing with beading or rubber casket not exceeding 0.5 Sqm in each pane etc complete all as specified and directed
Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
S&F 100 mm stainless steel butt hinges,complete all as specified and directed
S&F 150mm length aluminium anodised barrel tower bolt of extruded section complete all as specified and directed
S&F 150 mm length extruded aluminium alloy handles,fabricated type, anodised complete all as specified and directed
S&F alluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alluminium alloy and fixed of length of bolt 300 mm complete all as specified and directed.
M & L for false ceiling of galvanised iron frame work of angle section of 15 x 15 x 28 gauge for support and main U section of 40 x 20 x 26 Gauge and supporting U clip of 32 x 18 x 26 Gauge and gypsum board of 12.5 mm thick in panels fixed to GI frame work including cutting, bolting, welding etc of GI frame work and providing POP finish to the ceiling and applying two coat of OBD complete all as to the satisfaction of Engr - in - Charge
S&F double action floor spring hydraulically regulated made up of minimum alloy sheet foundation box main body with stainless steel cover , governing pivot made of brass ,other parts made of mild steel heavy duty and fixed all as spd and directed.
S&F mortice aluminium door lock 100 mm with aluminium 4 levers with all fittings all as spd and directed
S&F aluminium (extruded section) body hydrualic door closer designation No 1 universal type suitable for door shutter up to 700 mm in width and of weight not more than 35 kg and fixed.
S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S&F CI floor traps with grating complete 100mm bore outlet including jointing to waste pipe fixed in cement mortar type B1 1:2:4.
Cutting and grooving of wall for fixing of GI pipe lines and after fixing of GI pipe line and making good of all cutting surfaces
S&F 15mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
M/L for 25 mm thick green marble (table rubbed, and polished) in steps, jambs, pillars, windows-cill, cooking platform , jambs, urinal partition,wash basin platform and like in cement mortar 1:4 including pointing in white / coloured cement 1:2 using marble dust with admixture of pigment to match including one side full round edging including backing coat of 10 mm thick in CM 1:3 etc complete all as specified and directed.
S&F in repairs CP long nose bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&F aluminum anodised grill DG- 202 ( 10 mm x 5.2mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed. Note : (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
Supply only for 6mm thick bakelite sheet prelaminated both side with decorative choice laminations with aluminium frame cuboard shutter work complete all as specified and directed.
M&L for 20 to 25mm thick machine cut and machine polished cudappa stone slab for kitchen plateform jointed and set in CM 1:3 and fi fixed including rounding to edge of stone slabs one side edge etc complete all as specified and as directed
S&F stainles steel sink with drainage board , 1 mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers including CI cantilever bracket, connecting union etc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm including supply and fixing bib tap CP with long body screwed for iron pipe complete all as specified and directed. Make : Nirali, Bule star ISI marked.
Taking down cement plaster on brick or stone walls, concrete surfaces as in drain etc. including racking out joint, hacking for key, scrubbing with water, etc.
M&L for rendering 10mm thick using factory manufactured pre mix/ready mix plaster of 'Roofit Mix' of M/s Premier Floor to Roof Materials Pvt Ltd/'Easy plast' of M/s Walplast Products Pvt Ltd/'Readiplast' of M/s Ultratech Cement Ltd' / Soundp last PMC-1 of M/s Sound buildcare Pvt Ltd/or other approved equivalent make, having minimum composition of C:S : 1:6 using fully treated dry, well graded natural sand confirming to IS 383 suitable for plastering, having low rebound properties, low water demand for curing properties mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over masonry and concrete surfaces , including cleaning the surfaces, curing etc. complete all as specified & directed by Engineer-in-Charge
M&L for rendering 5 mm thick on ceiling using factory manufactured pre mix/ready mix plaster of 'Roofit Mix' of M/s Premier Floor to Roof Materials Pvt Ltd/'Easy plast' of M/s Walplast Products Pvt Ltd/'Readiplast' of M/s Ultratech Cement Ltd' / Soundp last PMC-1 of M/s Sound build care Pvt Ltd/or other approved equivalent make, having minimum composition of C:S : 1:3 using fully treated dry, well graded natural sand confirming to IS 383 suitable for plastering in ceiling, having low rebound properties, low water demand for curing properties mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over concrete surfaces , including cleaning the surfaces, curing etc. complete all as specified & directed by Engineer-in-Charge .
M & L for cement plaster 15 mm thick in CM 1:4, two coats using factory manufactured pre mix/ready mix of 'Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd/ 'Easy plast' of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd/'Soundplast PMC-1' of M/s Sound buildcare pvt.Ltd/ or other approved equivalent make, having minimum composition of C:S :: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnIcal mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces with base coat of 10 mm thick and finishing coat of 5 mm thick final rendering,including using richer mix for making corners if necessary, including water proffing powder at 3 % of cement at all floors and level, including making grooves of existing size wherever required, including cleaning the surfaces, curing etc. complete all as per specifications & as directed by the EIC note: water proofing powder will be measured and paid seperately
M&L for preparation of new plastered suface of wall and applying two coat of oil emulsion distemper over one coat of alkali resistent primer including Birla wall care putty complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of old distempered surface of wall including complete removal existing treatment and applying two coat of oil emulsion distemper over a coat of primer including Birla wall care putty complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of newly plastered wall sufaces of ceiling and applying 3 coats of white wash including Birla wall care putty complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of old plastered or unplastered decorated surfaces on ceiling complete all as specified and as directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc out side MD land complete all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in vertical surface etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles.complete all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.11 sqm n exc 0.18 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350x250mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:3 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
Chipping, removing carefully loose/damaged concrete including plastering (total thickness exceeding 40mm but not exceeding 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hour between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for carry out application of ‘Bi-polar migratory corrosion inhibitor' [Make : M/s. Krishna Conchem (EPCO KP-100) / BASF (MasterProtect®8000Cl)] on RCC surfaces, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for providing Polymer Bonding Agent of Make M/s. Krishna Conchem (MONOBOND) OR Fosroc (NITOBOND-SBR) OR equivalent brand of Dr. Fixit,as approved by the GE followed by flexible polymer based putty ( 1cement: 1.2 finesand :20% polymer by weight of cement : water as required ) on cracks after cutting the cracks to a 'V' shaped groove upto 10 mm wide and 10 mm deep in structural RCC members , finished with spatula etc. complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressedRCC members (exceeding 60mm in thikness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
M&L for building up the profile of structural members using polymer modified mortar from M/s. Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar from M/s Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr. Fixit, exceeding 20mm thick and not exceeding 40mm thick in two layers, each of equal thickness including levelling, profilling etc, complete all as specified and directed.
M&L for special treatment for sunken portion of WCs/ Bath & toilet executed in following stages:- Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debris outside MD land etc Complete. Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantity all as per Manufacture's instructions. Stage 3:- Apply Dr Fixit Primeseal primer or Equivalent of STP Ltd (and allow to dry for 8 hours) all as per Manufacture's instructions. Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per Manufacturer's instructions. Stage 5:- Rendering 10mm thick in CM 1:3 mixed with Integral water proofing chemical Dr Fixit Pidicrete URP or plaster seal of STP Ltd all as per Manufacture's instructions. Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP all as per Manufacture's instruction. Stage 7:- Making holes in wall and fixing 600mm long 40mm dia medium grade GI spout for draining the surplus water if any Stage 8:- Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion.water tightness of repaired sunken portion and filling of sunken portion for cement concrete Type E2 1:5:10 using 40 mm graded aggregate as in lean concrete complete all as specified and directed. Note :- (a) Only plan area shall be measured and accorded for payment under this item. (b) Depth of sunken portion of WC's/Baths shall be upto 35cm, which is to be taken into account while quoting the rate against this item. (c) Rate quoted by Contractor shall be deemed to be included for all the horizontal and verticale treated surfaces of sunken portions of WC & Bath.
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
S&F in repairs CP concealed stop cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 40mm complete all as specified and directed.
S&F 20mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
All as per item No 86 above but 25 mm bore etc, complete all as specified and directed.
All as per item No 86 above but 15 mm bore etc, complete all as specified and directed.
All as per item No 86 above but 40 mm bore etc, complete all as specified and directed.
Dismantling cast iron of any description etc complete all as specified and directed
S&F in repair 75mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F in repair 110mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F in repair 75mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F in repair 110mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F in repair 75mm bore PVC (SWR) branch piece, single (single Y ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F in repair 75mm bore PVC (SWR) branch piece, double Y equal or unequal with access doors etc, complete all as specified and as directed.
S&F in repair 110mm bore PVC (SWR) branch piece, single (single Y ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F in repair 110mm bore PVC (SWR) branch piece, double Y equal or unequal with access doors etc, complete all as specified and as directed.
S&F in repair 75mm bore PVC (SWR) junction single (single T ) equal or unequal with access doors etc, complete all as specified and as directed.
S&Fin repair PVC floor trap 75mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
S&F in repair PVC floor trap 100mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
M & L for demolition of RCC of any description and in any position , at any floor all incl. manhole covers as directed by Engr-in-Charge
S&F pre-coloured corrugated galvalume (55% aluminium + 43.5% Zinc+ 1.5% Silicon) steel sheets as in roofing/wall cladding, 0.50mm thick (Total coated thickness), 0.45 mm ( base metal thickness )conforming to AS-1397/ASTM A-792 and having yield strength minimum 550 MPA fixed with hot dip galvanised, self drilling and self tapping screws neoprene and EPDM washers and fixed as per manufacturers instructions complete all as specified and directed.
S&F pre-coloured plain galvalume (55% aluminium + 43.5% Zinc+ 1.5% Silicon) steel sheets, 0.50mm thick (Total coated thickness), 0.45 mm ( base metal thickness ) conforming to AS-1397/ASTM A-792 and having yield strength minimum 550 MPA fixed with hot dip galvanised, self drilling and self tapping screws neoprene and EPDM washers and fixed as per manufacturers instructions complete all as specified and directed.
M & L for framed brackets od angles or tees with web and flanges cut to shape , drilled and countersunk for screw, including bending and welding angles, as necessary gusset plates, riveting, etc. all as directed by Engr-in-Charge.
M&L for preparation of old / newly plasteded surface of wall including complete removal of existing surface and applying two coat of Acrylic weather proof coat 100% exterior grade paint over one coat of Acrylic primer complete all as per manufacturer's instructions and complete all as specified and as directed by Engineer-in-Charge.
Systematically cleaning of the sewage lines including gully traps by passing ropes, Knots, bamboo/wire/kandi rotary cleaner etc for dia of sewage pipe 100 mm complete all as specified and as directed by Engineer-in-Charge.
All as per item No 104 above but dia of sewage pipe 150 mm. complete all as specified and as directed by Engineer-in-Charge.
All as per item No 104 above but dia of sewage pipe 200 mm. complete all as specified and as directed by Engineer-in-Charge.
Cleaning of manholes of any size, shape and depth not exc 1.50m including pumping out liquid waste if any, removing all solid waste materials such as stones, bricks, pipes, plastic etc, pluggings / diverting of flow if required and removing the debries outside MD land etc including all precautionary and saftey measures complete all as specified and as directed by Engineer-in-Charge. (Note : Volume of sludge will only be measured for the purpose of payment and contractor's quoted rate shall be deemed to be included for de-watering.)
Cleaning of drain by mud of any size, shape and depth and removing the debries outside MD land etc incl all precautionary and safty measures all as directed by Engr-in-charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as directed by Engr-in- charge
Demolition of brick work built in cement mortar including PCC coping etc and removing the rubbish out side MD land complete all as specified and as directed by Engineer-in-Charge.
M&L rendering 15mm thick plaster on concrete/brick masonry surfaces in CM(1:6) finished even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M &L for Rendering 15mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:6, including finishing with 3 mm wall care putty, even& smooth without using extra cement.
M&L 5mm thick plaster in CM (1:3) on concrete surfaces of ceilings incl Sagol finish complete all as specified and directed by Engr-in-charge.
Demolition and breaking of drain AC / PVC / SWG / RCC pipes set in cement mortor for 100 mm bore pipe
All as per item No 112 above but dia of sewage pipe 150 mm
All as per item No 112 above but dia of sewage pipe 200 mm
All as per item No 112 above but dia of sewage pipe 300 mm
M&L for Concrete bed in PCC 1:3:6 type C2 to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 100 mm dia pipe
M&L 100 mm dia, Salt glazed stoneware drain pipe laid in trenches and jointed complete as specified
M&L for Concrete bed in PCC 1:3:6 type D2 to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 150 mm dia pipe
M&L for Concrete bed in PCC 1:3:6 type D2 to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 200 mm dia pipe
M&L for Concrete bed in PCC 1:3:6 type D2 to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 300 mm dia pipe
M&L RCC pipes 150 mm bore class NP-2 laid and jointed complete with spigot & socket joint
All as per item No 118 above but dia of 200 mm
All as per item No 118 above but dia of 300 mm
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specfified and as directed by Engineer-in-Charge.
Cutting into existing man holes for 100 mm dia pipe for connecting new drains , making good to piep and rendering , cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished and forming branching as required.
All as per item No 120 above but dia of 150 mm
All as per item No 120 above but dia of 200 mm
M&L for precast cement concrete (1:2:4) type B-1 (20mm graded aggr) for cover slab of Manhole setting in CM (1:6) complete all as specified and directed.
M&L cement concrete (1:2:4) type B-2 using 40mm graded aggregate as in surface channel and drain, benching for manhole & drain, foundations filling complete all as specified and as directed.
S&Fin repair wash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device (excluding flushing cistern ) etc complete all as specified and directed.
S&F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
S&F in repairs CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&Fin repair 15mm size PVC connection with PTMT nuts 450mm length.complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in kitchen platform and similar work laid, bedded and pointed in cement mortar and removal of rubbish/ demolished materials out of MD land complete all as specified and directed
M&L for 18-20mm thick granite(of any type) work table rubbed and polished as in steps, jambs, pillars, windows-cill, cooking platform , jambs and the like in cement mortar (1:4) including pointing in white / coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting , moulding etc over and including 10mm thick rendering / screed in CM 1:4 on fair faces of brick/concrete surfaces complete all as specified and directed.
Excavation in post holes (or similar holes)each n exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing soil to a distance n exc 50m and making good finish all as specified by Engr-in-Charge
M & L for joist, channel, angles or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lenghts, ) Fe 410-W (Gde-E- 250) quality-A all as directed by Engr-in-charge
M & L for compound girder and stanchions lattice girders, aerial masts, staging for water tanks and the like including caps, bases splices etc. Built up from two or more beam or channel sections or angles with plates, including all latice bars, stiffeners, gusset plates Fe 410-W (Gde-E- 250) quality-A all as directed by Engr-in-charge.
M & L for plates (plain) channel, square or cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W (Gde-E- 250) quality-A all as directed by Engr-in-charge
M&L for preparation of new surfaces of steel, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M & L for Rotational moulded polyethylene water storage tanks 1000 ltr (cylindrical vertical with closed top) hoisted and fixed, all as directed by Engr-in-charge
M & L for Rotational moulded polyethylene water storage tanks 500 ltr (cylindrical vertical with closed top) hoisted and fixed, all as directed by Engr-in-charge
S&F in for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 25 mm bore complete all as specified and directed.
S & F ball brass vlave high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed all as directed by Engr-in-charge
M & L for dismatling water tanks alongwith old pipe lines and removing to store,all as directed by Engr-in-charge
S&F pully system aluminium cloth hanger consisting of aluminium pipe of outer dia 22mm, inner dia 19.8 mm and channel pair of length 24"( delrin) with rope guide locking system to hide the rope knot .channel mounted with self taping screws. Rope will be HDPE double core of 4mm dia fixing to ceiling etc. complete all as spd and directed by Engr in charge Make : Easydry or equivalent as approved by GE. Note: minimum wt of pipe shall not be less than 0.70Kg/m and min wt of pipe in one unit not be less than 2 kg. (2) Minimum wt of rope shall not be less than 550 gms per unit.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 23855.00 (Minus) as listed in Schedule of Credit Note: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
vikas construction
DWARKESH STRUCT-CON
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .