| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.0 L+₹1.5 L (8.62%)Rejected-Finance ANGALAMMAN KOVIL STREET ULIYANALLORE POST PANAPAKKAM VIA ARAKKONAM TK VELLORE DIST TN 631 052 | ARAKKONAM | VELLORE | TAMIL NADU | 631052 | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹19.4 L+₹1.9 L (10.9%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹19.8 L+₹2.3 L (12.9%)Rejected-Finance 1 28 NORTH STREET SOUTH VILAYANARAYANAM NANGUNERI TALUK TIRUNELVELI DIST 627 118 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627118 | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹20.1 L+₹2.6 L (14.6%)Rejected-Finance CHENNAI | L5 | Rejected-Finance L1 being accepted |
Tender Value
Refer Docs
EMD Value
₹33,000
Closing Date
24 Dec 2020, 6:00 pmClosed
GE Tirunelveli
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAM TIRUNELVELI
REPAIR/MAINT OF LT LINES, LT PANELS AND UG CABLES AND ITS CONNECTED WORK AND REPAIR/MAINTENANCE OF STREET LIGHTS AT PARUNDU UNDER GE TIRUNELVELI
2020_MES_399252_1
GE/TVL/8132
Open Tender
Miscellaneous Works
Item Rate
180 days
Ramnad
As per NIT/ Tender documents
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹33,000
Yes
1 Apr 2021
28 Nov 2020
26 Dec 2020
28 Nov 2020
24 Dec 2020
12 Dec 2020
28 Nov 2020 - 7 Dec 2020
Amount
SCHEDULE 'A' PART-I [ E/M WORKS]
Excavation in trenches n.exc 1.5 M wide and n. exc 1.5 M depth and getting out in hard/dense soil for removing / taking out burnt cables complete all specified and as directed.
Returning, filling in incl spreading leveling, watering and well ramming in layers n.exc.25cm thick complete all specified and as directed.
Removing excavated material to a distance n.exc 50 M and depositing where directed at a level n.exc 1.5 M above the starting point complete all specified and as directed.
Supply and spread river sand in trenches for cable cushioning complete all as specified and directed. Note:- (Punned thickness only will be measured)
Supply and lay burnt bricks of old size sub-class B for cable protection all as directed & as specified.
S & F in replacement pole mounting type FRP cable looping box of outside dimension 230x170x105mm with connector , MCB SP 6 Amps with 40 x 6mm flat iron including suitable brass gland, lugs etc and terminal box to be fixed on pole with suitable fixing arrangement all as specified and as directed.
Supply and fix 40 mm dia light grade GI tube bracket of length 1.5 metre bend to required shape including MS clamp made out of 40 mm x 6 mm MS flat iron and fix on steel tubular poles with necessary GI bolts, nuts and washers - 2 sets for each fittings including taking down the existing GI tube bracket complete set all as specified and directed.
Cutting the existing bituminous road / cement concrete surface to the required width and depth for laying pipe lines and returning filling in, removal of surplus material complete all as specified. Note: PCC for making good the top level to match raod surface shall be measured and paid separately.
Demolition of cement concrete in ground floor and pavings not exc 15 cm thick below or above GL complete all as specified and as directed.
M & L for 75 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed.
Taking down street light pole / post top lantern / building security light/Hanger luminaires periemeter light from pole/wall/bldg/gate/hanger, of any type / capacity and repair the fittings by removing unserviceable parts and replacing with new parts as mentioned below to make the fitting operational and fixing back in original position after repair complete all as specfied and directed. Notes :-Spares parts required to making the fittings serviceable will be measured and paid separatly under relevant items here in after .
Supply only the following Spare parts/items to incorporate in street light fittings included vide item No.12 here-in-before . Make- Philips/Crompton greaves/Bajaj/Surya
Supply only Copper wound Ballast suitable for Metal Halide lamp 70 Watt.
Supply only Ignitor suitable for Metal Halide lamp 70 Watt.
Supply only Metal Halide Lamp 70 Watt.
Supply only lamp holder Metal Halide Lamp 70 Watt.
Supply only Copper wound Ballast suitable for Metal Halide lamp 150 Watt.
Supply only Ignitor suitable for Metal Halide lamp 150 Watt.
Supply only Metal Halide Lamp 150 Watt.
Supply only lamp holder Metal Halide Lamp 150 Watt.
Supply only Copper wound Ballast suitable for Metal Halide lamp 250 Watt.
Supply only Ignitor suitable for Metal Halide lamp 250 Watt.
Supply only Metal Halide Lamp 250 Watt.
Supply only lamp holder Metal Halide Lamp 250 Watt.
Supply only Copper wound Ballast suitable for Metal Halide lamp 400 Watt.
Supply only Ignitor suitable for Metal Halide lamp 400 Watt.
Supply only Metal Halide Lamp 400 Watt.
Supply only lamp holder Metal Halide Lamp 400 Watt.
S&F in repairs energy saving LED street light fittings, 30 Watts or nearest higher wattage, with in-built electronic driver, IP 66 class of protection with versatile pressure die-cast aluminium body, toughened glass cover with silicon gaskets and energy efficient LED and connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Make:Crompton LSTS-30-CDL/NL-M (ASTRA NEO)or equivalent in Philips/Bajaj/ Wipro
S&F in repairs energy saving LED street light fittings, 45 Watts or nearest higher wattage, with in-built electronic driver, IP 65 class of protection with versatile pressure die-cast aluminium housing parts, pure polyester powder coated dark gray housing, toughened glass cover with silicon gaskets and energy efficient LED and connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Make: Crompton LSTS-45-CDL-M (FREEDOM NEO) or equivalent in Philips/Bajaj/ Wipro
S&F in repairs energy saving LED street light fittings,72 Watts or nearest higher wattage, with 10kV SPD and in-built electronic driver, IP 66 class of protection with versatile pressure die-cast aluminium housing parts, pure polyester powder coated dark gray housing, toughened glass cover with silicon gaskets and energy efficient LED and connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Make: Crompton LSTP-72-CDL-M (NEXUS NEO) or equivalent in Philips/Bajaj/ Wipro
S&F in repairs energy saving LED flood light fittings with in-built electronic driver, 60 Watts or nearest higher wattage , , with 10 kV SPD, IP 66 ,with pressure die-cast aluminium body including high power LEDs and connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Make: Crompton LFL-60-CDL/60-M (PROFILE+ NEO) or equivalent in Philips/Bajaj/ Wipro
S&F in repairs LED flood light fittings with in-built electronic driver, 120 Watts or nearest higher wattage, with 10 kV SPD , IP 66 class of protection with pressure die-cast aluminium body including LED 120W and connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Make:Crompton LFLN-120-CDL/60-M (PLUTO NEO ) or equivalent in Philips/Bajaj/ Wipro
S&F in repairs LED flood light fittings with in-built electronic driver, 150 Watts or nearest higher wattage, with 10 kV SPD , IP 66 class of protection with pressure die-cast aluminium body including LED 150W and connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Make: Crompton LFLN-150-CDL/60-M (PLUTO NEO ) or equivalent in Philips/Bajaj/ Wipro
Labour only for taking down LED street light fittings from pole /LED building security light fitting and replacement of LED light driver and making the fitting serviceable and refixing in same/ new position or location after testing and dismantling of old unserviceable driver for taking into credit complete all as specified and as directed. The driver should be compatible to the existing LED light of any make. Note: 1. The make of driver should match with make of LED fitting. 2. Electronic driver shall be measured and paid separatly under relevant items here in after .
Supply only electronic driver, suitable for 20/25 Watts LED or nearest higher capacity street light fittings all as specified and as directed. Make: Bajaj/Wipro/Crompton/Phillips.
Supply only electronic driver, suitable for 35/40Watts LED or nearest higher capacity street light fittings all as specified and as directed. Make: Bajaj/Wipro/Crompton/Phillips.
Supply only electronic driver, suitable for 60/75 Watts LED or nearest higher capacity street light fittings /flood light fitting all as specified and as directed. Make: Bajaj/Wipro/Crompton/Phillips.
Supply only electronic driver, suitable for 120/150 Watts LED or nearest higher capacity street light fittings /flood light fitting all as specified and as directed. Make: Bajaj/Wipro/Crompton/Phillips.
S&F in repairs decorative 40 watts or nearest higher wattage LED post top lantern , with IP 65 protection with accessoriesand connecting up light fitting with copper conductor cable of suitable size from junction box to connector block and dismantling of old unserviceable fitting for taking into credit complete all as specified and directed. Make :- Cat No. LPTO-40/CDL-M MAPLE OF CROMPTON or equivalent in Bajaj/ Wipro/ Phillips
Supply and fix PVC insulated two single core 1.5 sqmm FRLS copper conductor and one run of 1.5 sqmm multistranded copper conductor as earth continuity conductor drawn through and including 20mm dia heavy duty non metallic rigid PVC conduit and accessories complete all as specified and as directed. Note : (i)Two run 1.5 Sqmm of single core, one run of 1.5 sqmm earth conductor and PVC conduit will be measured as one RM.
Supply and fix PVC insulated two single core 2.5 sqmm FRLS copper conductor and one run of 2.5 sqmm multistranded copper conductor as earth continuity conductor drawn through and including 20mm dia heavy duty non metallic rigid PVC conduit and accessories complete all as specified and as directed. Note : (i)Two run 2.5Sqmm of single core, one run of 2.5 sqmm earth conductor and PVC conduit will be measured as one RM
S&F LED Aviation/ Obstruction light 10 W or higher wattage installed on the roof of overhead reservoir or on roof top of high rise building/ hanger with taking down old unserviceable complete all as specified and directed. Make: Bajaj BGAV 302 LED or equivalent make of Philips/ Wipro/ Crompton
Material and labour for Triming of tree branches from the tree near the street light pole / building security light / periemeter light / solar light to provide all around clearance of 2 meter including cleaning of bushes around the pole and site clearance all as directed and as specified by Engr-in-charge. Note : 1. Shut down of HT/LT O/H line will be given on working days in between 1000 hrs to 1600 hrs. 2. Tools for branch cutting & Transport for carrying wastage of brances to be provided by contractor.
Supply and fix in repairs lamp holder bayonet pin base type PVC/Polycorbonate for LED bulb ,isolated body including taking down unserviceable lamp holders and removing the material for taking credit complete all as specified and directed
Supply and fix in repair LED bulb 18 watts bayonet pin base type including taking down old unserviceable item complete all as specified and directed.
S&F in replacement Phase indicator lamp assembly LED type (Set of three R,Y,B) complete with indicator lamp including making connections with 2.5 Sq mm copper conductor PVC insulated and PVC sheathed single core cable complete all as specified and as directed by Engineer-in-charge.
Supply and lay LT under ground cable 1100 volts grade Cross linked Polyethylene (XLPE) insulated PVC Sheathed Cables: armoured multistranded heavy duty electric cable with aluminium conductor 4 Core 16 Sqmm laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board, testing and commissioning etc including taking out existing unserviceable cables complete all as directed & as specified and as directed by Engineer-in-charge.
Description all as per item No 49 but 4 core 25 Sqmm size complete all specified and as directed.
Description all as per item No 49 but 3.5 core 35 Sqmm size complete all specified and as directed.
Description all as per item No 49 but 3.5 core 50 Sqmm size complete all specified and as directed.
Description all as per item No 49 but 3.5 core 70 Sqmm size complete all specified and as directed.
Description all as per item No 49 but 3.5 core 95 Sqmm size complete all specified and as directed.
Description all as per item No 49 but 3.5 core 120 Sqmm size complete all specified and as directed.
Description all as per item No 49 but 3.5 core 150 Sqmm size complete all specified and as directed.
Description all as per item No 49 but 3.5 core 185 Sqmm size complete all specified and as directed.
Supply and connect submersible PVC insulated cable 1100 V grade 3 core 4 sqmm with flexible copper conductor water resistant quality ISI marked including taking down old cable complete all as specified and directed.
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion including taking down of old all as specified and as directed. Note :1. The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia medium grade GI protection pipe for earth lead etc., complete. 2. Earthing strip upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately.
Supply and lay earth continuity conductor or main earting lead fixed to wall on batten or recess or burried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth strip of size 32 X 6mm including taking down old unserviceable earth strip complete for taking into credit complete all as specified and as directed by the Engineer-in-Charge
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth Lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.5 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on including taking down of old completion all as specified and as directed. Note :1. The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia medium grade GI protection pipe for earth lead etc., complete. 2. Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately.
Supply and lay earth continuity conductor or main earting lead fixed to wall on batten or recess or burried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth wire 4mm dia including taking down old unserviceable GI earth wire complete all as specified and as directed.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 63 amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 100 amps, with rupturing capacity 25 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 125 amps, with rupturing capacity 25 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 160 Amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 200 Amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 250 Amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
Servicing & overhauling of Air Circuit Breaker (ACB) of any capacity by taking out from existing LT panel, cleaning all parts internally and externally, checking of the proper tension of the springs mechanical mechanism, tightening of connection of moving, fixing contact, floating contacts, servicing of motor & charging system incl replacement of faulty parts/spares and re-fixing it on its original position and testing complete all as directed.
M & L for repair/overhauling of old LT panel board of any size/type incl cleaning with compressed air, tightening of all electric connections to bus bar & switchgears, re-fixing of door (front & backside) with proper fixing & replacement of butt hinges/ Lock with key, replacement of bus bar ,replacement of wornout lugs, nut, bolts, proper connection to main earth lead, glands to be provided/replaced as required at cable entries, fixing of door front & back side with proper locking arrangement, repair to PCC foundation as required at site and spray painting with powder coated paint with smoke grey paint in outer/inner side of panel after cleaning and preparing surface complete all as directed. Note : Aluminium Bar shall be measured and paid under respective item.
Supply and fix only Aluminum bus bar of required size and design after careful inspection at site including removing the old burnt unserviceable bus bar and making necessary connections as per standard procedure including taking down old unserviceable busbar all as specified and as directed.
Dismantling & taking out defective LT PVC/XLPE cable from trenches cutting and removing defective parts and supply and fixing straight through joint heat shrink kit complete including jointing material and making connection of LT cables size 2 core 10 to 16 sqmm complete all as specified and directed. Note :- Excavation, returning filling in removing, sand cushioning, brick etc shall be measured and paid separately under respective items of work.
Description all as per item No 72 but 3/ 3.5/ 4 core 10 to 16 sqmm size complete all specified and as directed.
Description all as per item No 72 but 3/ 3.5/ 4 core 25 to 50 sqmm size complete all specified and as directed.
Description all as per item No 72 but 3 /3.5/ 4 core 70 to 150 sqmm size complete all specified and as directed.
Description all as per item No 72 but 3 /3.5/ 4 core 185 to 300 sqmm size complete all specified and as directed.
Supply and fix in repairON Load Change over switch 415V 4 pole 100Amps in sheet metal enclosures with auxillary switch and spreader links as applicable to to frame size including taking down old unserviceable ON Load Change over switch for taking into credit complete all specified and as directed.
Supply and fix in repair ON Load Change over switch 415V 4 pole 125 Amps in sheet metal enclosures with cabe gland,auxillary switch and spreader links as applicable to to frame size including taking down old unserviceable ON Load Change over switch for taking into credit complete all specified and as directed.
Supply and fix in repair ON Load Change over switch 415V 4 pole 160 Amps in sheet metal enclosures with cabe gland, auxillary switch and spreader links as applicable to to frame size including taking down old unserviceable ON Load Change over switch for taking into credit.
Supply and fix in repair ON Load Change over switch 415V 4 pole 200 Amps in sheet metal enclosures with cabe gland, auxillary switch and spreader links as applicable to to frame size including taking down old unserviceable ON Load Change over switch for taking into credit complete all specified and as directed.
Supply and fix in repair ON Load Change over switch 415V 4 pole 250 Amps in sheet metal enclosures with cabe gland, auxillary switch and spreader links as applicable to to frame size including taking down old unserviceable ON Load Change over switch for taking into credit complete all specified and as directed.
Supply and fix in repair ON Load Change over switch 415V 4 pole 200 Amps in open execution suitable for fixing in LT Panel with cabe gland, auxillary switch and spreader links as applicable to to frame size including taking down old unserviceable ON Load Change over switch for taking into credit complete all specified and as directed.
Writing letters (Block.Roman, Italic or Indian) with thick paint ,stand out boldly and solidly without showing signs of brush marks, if necessary, repainted until the desired result is obtained , 10 to 15 cm height and painting with contrasting colour in the background of letter complete as directed. NOTE:Colour of paint shall be decided by the Engg-in-charge.
Taking down old unserviceable old damaged GI pipe and Supply and fix new GI pipe light grade of size 50mm dia for protection of UG cable on walls/under floors/road crossings/in trenches including taking down old unserviceable earthing GI pipe for taking into credit complete all as specified and as directed by the Engineer-in-Charge complete.
Taking down old unserviceable old damaged GI pipe and Supply and fix new GI pipe light grade of size 80mm dia for protection of UG cable on walls/under floors/road crossings/in trenches including taking down old unserviceable earthing GI pipe for taking into credit complete all as specified and as directed by the Engineer-in-Charge complete.
Supply and fix danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, , complete all as specified and as directed by the Engineer-in-Charge
Supply and fix Synthetic Insulating Mat of size 2m x 1m x 19mm and removing old unserviceable mat from the site all as specified and directed by Engineer-in-charge.
Laying only for LT under ground cable 1100 volts grade PVC /XLPE sheathed armoured multistranded heavy duty electric cable with aluminium conductor laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board, testing and commissioning etc including taking out existing unserviceable cables of following sizes complete all as directed & as specified:-
(a) 3.5 core 16 sqmm /25 sqmm /35 Sqmm
(b) 3.5 core 50 sqmm/ 70 sq mm / 95 sq mm
(c) 3.5 core 120 sqmm/ 150 sq mm / 185 sq mm Note for Item No. 88 :- LT UG cable for Item No. 88.01 to 88.03 shall be issued under Schedule 'B' under free for fixing/laying only.
Supply and fix flame proof brass double compression cable gland duly nickel plated suitable for following cable sizes
(a) Cable Outer Diameter 23 mm to 25 mm Nipple ET thread size 1 " suitable for 3.5 core 25 sqmm to 35 sq mm
(b) Cable Outer Diameter 26 mm to 30 mm Nipple ET thread size 1 1/4 " suitable for 3.5 core 50 sqmm to 70 sq mm
(c) Cable Outer Diameter 33 mm to 36 mm Nipple ET thread size 1 1/2 " suitable for 3.5 core 70 sqmm to 95 sq mm
(d) Cable Outer Diameter 37 mm to 41 mm Nipple ET thread size 2 " suitable for 3.5 core 120 sqmm to 150 sq mm
(e) Cable Outer Diameter 46 mm to 52 mm Nipple ET thread size 2 1/2 " suitable for 3.5 core 185 sqmm to 240 sq mm
Supply and fix copper lugs heavy duty suitable for XLPE LT cables of following size complete all as specified and directed :-
(a) Size 25 sq.mm
(b) Size 35 sq.mm
(c) Size 50 sq.mm
(d) Size 70 sq.mm
(e) Size 95 sq.mm
(f) Size 120 sq.mm
(g) Size 150 sq.mm
(h) Size 185 sq.mm
Dismantling & taking out HT/LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/in trenches/along pole/ panel/feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete all as specified and directed.
Supply and Fix cast iron oval shaped water supply pipeline / HT & LT cable route / cable joint / cable loop indicator of size 150 mm x 150 mm x 6 mm thick with letters embossed and fixed with 750 mm long MS angle iron 25 x 25 x 5mm and 'T' base of 25x25x5mm, 200mm long with welding and painting, including connected earth work and excavation as in post holes in any type of soil providing PCC 1:3:6 type C1 of size 660x600x250 mm (using 20mm graded stone aggregate)to hold the angle iron (by putting the split end of angle iron in to the concrete) up to ground level and painting the exposed iron surface with grey colour over a coat of primer etc complete after tracing the route of burried water supply pipe line / cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Three Phase Submersible Pump Controllers for motor 3-5 HP with DOL starter, Single Phase Preventer, with contactors and relay for ON/OFF operation and overload protection of the pump set, single-phasing prevention, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment for delayed operation of pump set including taking down old unserviceable Starter all as specified and as directed.
Supply and fix Three Phase Submersible Pump Controllers for motor 7.5 HP with DOL starter, Single Phase Preventer, with contactors and relay for ON/OFF operation and overload protection of the pump set, single-phasing prevention, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment for delayed operation of pump set including taking down old unserviceable Starter all as specified and as directed.
Supply and fix DOL Starter suitable for motor capacity 2 HP - 7.5 HP including taking down old unserviceable Starter all as specified and as directed.
Supply and fix in replacement of Heavy duty Capacitor for power factor correction 3 Phase, 415Volt (AC), 50 HZ of cap 2 KVAR including making connections complete all as specified and as directed by Engineer in charge.. Make - L& T / Siemens / Crompton/Indo Asia/ABB
Supply and fix in replacement of Heavy duty Capacitor for power factor correction 3 Phase, 415Volt (AC), 50 HZ of cap 5 KVAR including making connections complete all as specified and as directed by Engineer in charge. Make - L& T / Siemens / Crompton/Indo Asia/ABB
Supply and fix in replacement of Heavy duty Capacitor for power factor correction 3 Phase, 415Volt (AC), 50 HZ of cap 7.5 KVAR including making connections complete all as specified and as directed by Engineer in charge. Make - L& T / Siemens / Crompton/Indo Asia/ABB
Supply and fix in replacement of Heavy duty Capacitor for power factor correction 3 Phase, 415Volt (AC), 50 HZ of cap 10 KVAR including making connections complete all as specified and as directed by Engineer in charge. Make - L& T / Siemens / Crompton/Indo Asia/ABB
Supply and fix in replacement of Heavy duty Capacitor for power factor correction 3 Phase, 415Volt (AC), 50 HZ of cap 20 KVAR including making connections complete all as specified and as directed by Engineer in charge. Make - L& T / Siemens / Crompton/Indo Asia/ABB
Supply and fix in replacement of Heavy duty Capacitor for power factor correction 3 Phase, 415Volt (AC), 50 HZ of cap 25 KVAR including making connections complete all as specified and as directed by Engineer in charge.. Make -L& T / Siemens / Crompton/Indo Asia/ABB
S&F in repairs energy saving LED street light fittings,70 Watts or nearest higher wattage, with 10kV SPD and in-built electronic driver, IP 66 class of protection with versatile pressure die-cast aluminium housing parts, pure polyester powder coated dark gray housing, toughened glass cover with silicon gaskets and energy efficient LED and connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Make: Crompton LST-70-CDL-M (ORION NEO) or equivalent in Philips/Bajaj/ Wipro
JR ENTERPRISES
MURUKAN BUILDERS
sri manikandan enterprises
VVM CONSTRUCTIONS
Vinayaga constructions
S KUMARAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .