Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.3 L+₹2.0 L (18.1%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹13.9 L+₹2.6 L (23.5%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹17.3 L+₹6.0 L (53.4%)Rejected-Finance PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹17.3 L+₹6.0 L (53.5%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
10 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Delhi Cantt-10
GE South Delhi Cantt-10
REPAIR/REPLACEMENT OF E/M NATURE OF WORKS AT VARIOUS MD AND OTM ACCN AT BANA SINGH, YOGENDER VIHAR, 180 MAHIPALPUR, 35 INF BDE, 227 FD WKSP, 18 MADRAS AND 5/11 GR UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2023_MES_595336_1
GE/DS-16/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹84,000
Yes
28 Jun 2023
13 May 2023
12 Jun 2023
13 May 2023
10 Jun 2023
27 May 2023
Amount
Attending complaints for checking the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc., Attending minor repair(s) such as testing, connections, fittings, nut, bolts screws, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/ internal circuits of existing electrical system of main building/block and making continuous electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, earthing wire as required at site complete all as specified and as directed.
Note :- (i) Minium one electrician and one Mate electrician shall be provided by the contractor for attending daily complaints on working days including holidays/sunday shall report to MES complaint cell at 8:30 hrs and One electrician shall be provided by the contractor for attending night duty complaints daily including holidays/sunday. (ii) Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. (iii) The MES Department is not responsible for the payment of electrician, as all the items of CA are to be supply and fixed by the contractor. (iv) The Contractor will ensure that the team of electricians with necessory tools bag shall always remain present at complaint cell to attend the complaints. (v) A recovery of Rs 50/- per complaint shall be recovered from the contractor for non attending the complaint on same day. (vi) All the complaint slip,register & other connected document will be provided by the contractor without any extra cost. (vii) Proper record (date wise) of complaints received & rectified by the contractor of trademen shall be maintained and shall be produce for verification at the time of payment of each RAR/Bill. (viii) These tradesman shall not be utilised for the undermentioned items where item catered as 'S&F' and 'M&L'.
S&F in repair switch piano flush type 6 Amps SP one way complete all as specified and as directed.
S&F in repair switch piano flush type 6 Amps SP 2-way complete all as specified and as directed.
S&F in repair bell push, flush type 6 Amps complete all as specified and as directed.
S&F in repair socket outlet 6 Amps flush mounted piano type 5 pin multi purpose complete all as specified and as directed.
S&F in repair switch piano type 16 Amps SP one way complete all as specified and as directed.
S&F in repair socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type complete all as specified and as directed.
S&F in repair lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
S&F in repair ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and as directed.
S&F in repair fan regulator electronic, stepped type, Switch type, suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed.
S&F in repair switch socket combination 2-in-1, 6 Amps flush type complete all as specified and as directed.
S&F in repair switch socket combination 2-in-1 6 & 16 Amps flush type complete all as specified and as directed.
S&F in repair old unserviceable plug top 15/16 Amps complete all as specified and as directed.
S&F in repair PVC casing caping of size 20 x 12mm of ISI Mark or as per manufacturer design with all accessories for surface wiring complete all as specified and as directed.
S&F in repair bell Ding dong type 230 volts single phase complete all as specified and as directed.
S&F in repair LED 10 watt white Bulk head in engineering plastic housing with clear prismatic including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and as directed.
S&F in repair LED Batten fitting 20 watt LED White, indoor decorative PVC extruded LED battern -integrated type complete all as specified and as directed.
S&F in repair LED Integrated Batten T5 10 watt - 2FT White, indoor decorative aluminum extruded T5 LED battern -integrated type complete with including fliexble wire complete all as specified and as directed.
S&F in repair Surface mounting round/square shaped LED downlighter 6 Watt LED lamp type from ceiling of stairs/common areas complete all as specified and as directed.
S&F in repair old unserviceable wall light fixture any type with, Decorative wall light fixture made up of Polycarbonate,base including 12 Watt LED Bulb of 6.5K complete all as specified and as directed.
S&F in repair Recessed/surface mounting 36 watt 2' x 2' flat LED panel fitting with soft light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in replacement of existing old unserviceable CFL fitting any type from ceiling of common areas and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and as directed.
S&F in repair LED Building security light fitting 30W on existing bracket in replacement of old unsv existing security light fitting any type complete all as specified and as directed.
S&F in repair Circuler Hylam/PVC Sheet 4 to 10 Cm dia (for using as Junction box Cover) including screws and cup washer complete all as specified and as directed.
S&F in repair PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement in Red/Blue/Yellow&Black&green colour complete all as specified and as directed.
S&F in repair PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and in green colour complete all as specified and as directed.
S&F in repair PVC insulated FRLS 3 core with stranded copper cable of size 2.5 Sqmm for any type of wiring as per site requirement complete all as specified and as directed.
S&F in repair clamp with rubber real for hanging ceiling fans of 1200/1400mm sweep as per sample complete all as specified and as directed.
S&F in repair MCCB 3 pole, 415V, Adjustable type,125 amps with breaking capacity 16KA complete all as specified and as directed.
S&F in repair MCCB 3 pole 160 Amps 36 KA 415 Volts with breaking capacity 16 KA, in replacement complete all as specified and as directed.
S&F in repair MCB SP 06 to 32 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and as directed.
S&F in repair MCB SPN 40 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement and complete all as specified and as directed.
S&F in repair MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement and complete all as specified and as directed.
S&F in repair MCB TPN from 63 Amps 415 volts, 'C' Series 10 KA as per site requirement and complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete wiring only,. removing materials to store for keeping in safe custody for credit and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L point wiring for one light/fan/bell point conrolled by one switch SP, one way 230 volts complete with stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) and making good to disturbed surface of walls including necessary touch up with thw adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and as directed. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
All as per Srl item No.35 above, but one 3 pin socket outlet 5/6 Amps on same board.
All as per Srl item No.35 above, but one socket outlet 5/6 Amps on independent board.
All as per Srl item No.35 here-in-before, but one power socket 15/16 Amp but with cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm.
Supply only in replacement MS fastner bolt 8mm dia and 100mm (Min.) long for fixing geyser/ Exhaust fan/Bldg security light etc with nut and washer complete all as specified and as directed.
M&L in repairs submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit complete all as specified and as directed. Notes:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
M&L in repairs submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit complete all as specified and as directed. Notes:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
M&L in reparis earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing complete all as specified and as directed.
Note :- The contract sum shall be after deducting the amount of Credit shown in Sch of Credit of this Tender.
M/S Malik Construction Corporation
verma enterprises
M/S Parmod Johar
ramveer Singh
J V ENGINEERS / JAI SINGH
RAJDHANI ENTERPRISES
Vijeta Solutions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .