| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 LAccepted-AOC 1 1 MEREDITH STREET KOLKATA 700072 INDIA | KOLKATA | WEST BENGAL | 700072 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹49.9 L+₹4.7 L (10.5%)Rejected-Finance | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹50.3 L+₹5.1 L (11.4%)Rejected-Finance 34 C R AVENUE JABAKUSUM HOUSE 3RD FLOOR ROOM NO 312 KOLKATA 700 012 | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹50.9 L+₹5.7 L (12.7%)Rejected-Finance 53 TOLLYGUNGE CIRCULAR ROAD KOLKATA 700 053 | KOLKATA | WEST BENGAL | 700053 | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹52.4 L+₹7.2 L (16.0%)Rejected-Finance | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
24 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8984/E8
2021_MES_474521_2
GE/ALP (8984) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
240 days
GE ALIPORE KOLKATA
Class D and Category a (i)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹84,000
Yes
11 Jan 2022
5 Oct 2021
25 Nov 2021
5 Oct 2021
24 Nov 2021
17 Nov 2021
60 days
Amount
Job No : BSA/KOL/AMWP/09/2020-21 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavating in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and as directed.
Material and labour for anti termite treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
Material and labour for anti termite treatment treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
Material and labour for anti termite treatment treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
Material and labour for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed.
Material and labour for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) for foundation, filling and mass concrete complete all as specified and as directed.
Material and labour for RCC M-25 design mix (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
Material and labour for RCC M-25 design mix (using 20 mm graded stone aggregate) as in Chajja complete all as specified and as directed.
Material and labour for RCC M-25 design mix (using 20 mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span ccomplete all as specified and as directed.
Material and labour for RCC M-25 design mix (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
Material and labour for RCC M-25 design mix (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Material and labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per item No 13 here-in-before but 6 to 8mm dia complete all as specified and as directed.
All as per item No 13 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
Material and labour for use and waste of formwork flat, rough finished to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.
Material and labour for use and waste of formwork flat, rough finished surfaces to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
Material and labour for use and waste of formwork square, rectangular or plougonal rough finished surfaces to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
Material and labour for use and waste of formwork to soffits of flat suspended slabs such as roof slabs, floor slabs, landings and similar work n.exc 200mm thick complete all as specified and as directed.
Material and labour for 40mm thick damp proof course to horizontal or vertical surfaces in cement concrete (1:2:4), type B0 including necessary formwork complete all as specified and as directed.
Material and labour for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Material and labour for brickwork with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortor (1:4) complete all as specified and as directed.
Material and labour for rendering 15 mm thick on surface other than fair face of brickwork or concrete surfaces in cement mortar (1:6), finished surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for rendering 15 mm thick on brick work or concrete surfaces in cement mortar (1:4) finished surfaces even and smooth without using extra cement including necessary scaffolding upto 4 storey bldg complete all as specified and as directed.
Supply only Liquid water proofing compound complete all as specified and as directed.
Material and labour for rendering 10 mm thick in cement mortar (1:3) as in ceiling finishing even and smooth (with out using extra cement) complete all as specified and as direcetd
Preparing of new surfaces of walls and applying two coats of cement base paint, complete all as specified and as directed.
Material and labour for preparation of new plaster surface and applying three coats of white wash on ceiling complete all as specified and as directed.
Preparing new plastered surfaces of wall and applying three coats of white wash on walls complete all as specified and as directed.
Hardcore of gauge n exc. 63 mm, (except material retreived from item 1) deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Material and labour for silver sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
Material and labour for 50mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and as directed.
Material and labour for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Material and labour for 75mm thick PCC (1:3:6), type C-1 (using 20 mm graded stone aggregate) as in plinth protection complete all as specified and as directed.
Supply and fixing wash basins, Vitreous China (flat back or angle back type) any size 550x400mm including taps cutting for and pinning in ends of brackets or erecting stand including fixing of supply and waste pipe, waste couplingof 32mm dia etc complete all as specified and as directed.
Supply and fixing 15 mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.
Supply and fixing PTMT tubular towel rail 600mm long, with and incl CP brass screws and wooden/plastic cleats, wt not less than 190 gms complete, fixed in wall complete all as specified and as directed.
Supplying and laying of CPVC pipes 20mm outer diameter SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed.
Supply and fixing 15 mm dia PVC connection 450 mm long, complete all as specified and as directed.
Supply and fixing 15 mm bore stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
Material and labour for 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
Supply and fixing PVC SWR bend of 75 mm bore complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated material exc 1.5 km but n.exc 5 KM and depositing where directed at a level n exc 1.5 mtr above the starting point in soft/loose soil complete all as specified and as directed.
Supply and fixing Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded upto 4 storey of bldg complete all as specfied and as diected.
All as per item No 46 but without glazing bar complete all as specified and as directed.
Supply and fixing for Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 (Height of bldg upto 4 storey) complete all as specified and as directed.
Supply and fixing for steel rolling shutters of 1.25 mm thickness laths with ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete push & pull & gear operated type with bevel gear box and crank handle. complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red-oxide zinc chrome primer complete all as specified and as directed.
Supply and fixing 4.00 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.50 Sqm in each pane complete all as specfied and diected.
Supply and fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specfied and directed.
Material and labour for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foot path complete all as specified and as directed.
Material and labour for 100mm thick cement concrete (1:2:4), type B2 (using 40mm graded stone aggregate) as in floor, hard standing and like complete all as speficied and as directed.
Material and labour for providing cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in coping and the like including weathering slightly rounded or chamferred angles and throating complete all as specified and as directed.
Material and labour for for PCC (1:2:4) type B-2 (using 40mm graded stone aggrgate) as in surface channels and drains complete all as specified and as directed.
Material and labour for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and as directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm over item No 57 complete all as specified and as directed.
Supply and fixing for 1000 ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical /vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
Demolition of brick work built in cement mortar complete all as specified and as directed.
Demolition of RCC in ground floors and pavings exc 15 cm thickness ( below or above the ground level) and removing old rubbish/broken material outside MOD land complete all as specified and as directed.
Material and labour for Mild Steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290(Gde E-165) complete all as specified and as directed.
Supply and fixing for 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including necessary scaffolding complete all as specified and as direcetd
Supply and fixing for 110 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal including necessary scaffolding complete all as specified and as direcetd
Supply and fixing for 100 mm bore PVC (SWR) bends any radius including necessary scaffolding complete all as specified and as direcetd
Supply and fixing for 110mm bore PVC (SWR) vent cowl, including necessay scaffolding complete all as specified and directed.
Material and labour for APP based polymeric membrane minimum weighing 3.6kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface with surface finish of white mineral by using buten torch application method and sealing all joints etc of minimum over lap 100mm on longitudinal direction and 150mm over lap on the transverse direction as per Para 11.44.4 of SSR Part-I 2009 and applying evenly a coat of bitumen primer on roof, @ 0.40 Ltr/Sqm by the same membrane manufacturer of density at 25 degree Celcies, 0.87 to 0.89 Kg/Ltr and viscosity 70-160 cps over 20mm thick screed bed or bedding layer of cement mortar (1:3) mixed with water proofing compound as per Para 11.44.2 of SSR Part-I 2009 including cleaning of existing roof surface complete all as specified and as directed.
Material and labour for point wiring with 1.5 sqmm PVC insulated unsheathed copper cable (FRLSH) multistrand conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC insulated unsheathed copper cable (FRLSH) multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC concealed conduit with all accessories and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick plastic laminated sheet cover for one light/fan point complete all as specified and directed.
All as per item No 68 here in before but for 3 pin 6Amp socket outlet on same board with 1.5 sqmm cable complete all as specified and as directed.
All as per item No 68 here in before but for 3 pin 6Amp switch socket combination on independent board with 1.5 sqmm cable complete all as specified and as directed.
All as per item No 68 here in before but for 3 pin 6/15 Amp switch socket combination on independent board with 2.5 sqmm cable complete all as specified and as directed.
Material and labour for switch socket combination 2 in 1, 5 pin 5 amp,240 v flush type complete all as specified and as directed.
Supply and fixing switch socket combination 2 in 1,5/15 Amps, 230 Volts, flush/Box type universal complete all as specified and as directed. .
Supply and fixing in socket outlet 2 in 1, 5 pin 5 Amp,230 Volts flush type. complete all as specified and as directed.
Material and labour for for switch flush type 6 Amps 230 volts single pole one way complete all as specified and as directed.
Supply and fixing ceiling rose surface bakelite three terminal complete all as specified and as directed.
Supply and fixing MCB, single pole, 240 Volts, of capacity (6-32 Amps) 'C' series as ordered breaking capacity 10 KA. complete all as specified and as directed.
Material and labour for MCB SPN, 63 Amps, 240 Volts ,'C' series of breaking capacity 10KA complete all as specified and as directed.
Material and labour for MCB SPN, 32 Amps, 240 Volts ,'C' series of breaking capacity 10KA complete all as specified and as directed.
Supply and fixing as MCB DB SPN (double door) 12 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.
Material and labour for bldg lighting of LED 25 watts high efficient lighting solution anodised confiming to IP65 with heat resistance with accessories provided including necessary electric connection with all accessories required for fixing/mounting with nut bolt washer & clamp support on GI pipe including taking down old unsv and make good the disturbed surface complete all as specified and as directed. crompton Cat No: LSTS-25-CDLor equivalent make specified in P.S.
Supply and fixing main stream battens fitting LED 20 watt tube aluminium body out put lux 100 lux /watt, 4 feet long fixing on PVC/wooden round block complete with all accessories, prewired and flexible wire twin core from ceiling rose to terminal block complete all as specified and as directed.
Supply and fixing exhaust fan of size 300m sweep, ingle phase with Louver Shutter suitable for the same exhaust fan and all accessories i.e. nut bolts washers etc.including making circular exhaust hole make good by cement work/plastering and matching connecting/testing complete all as specified and as directed.
Supply and fixing Lamp Holder PVC/Polycarbonated typewith back platesuitable for batten fittings complete all as specified and as directed.
Supply and fixing LED Lamp14/15watt direct fit type 230 V Complete all as Specified and as directed.
Supply and fixing LED Bulk Head 12 Watt with PDC aluminium housing and milky diffusiercomplete all as specified and as directed.
Supply and fixing 1200 mm sweep ceiling fan with double ball bearing, white colour including suitable hanging arrangement hook,clamp pipe of suitable size and length and connecting with 0.75 Sqmm, 3 Core flexible copper wire from ceiling rose to fan complete all as specified and as directed. Make :Havells Cat No.XP-390 or equivelent make specified in P.S.
Supply and fixing stepped type electronic fan regulator flush type on existing switch board as reqd for fan regulator 100 watt rotary step type AC 220 Volt complete all as specified and as directed.
Material and labour for sub main wiring for main DBs to sub DBs with standard copper conductor 1100 volts grade of size 6 sqmm two run of multistrand unsheathed PVC insulated cable (Red colour cable used for live connection & Black colour cable used for neutral connection) and 6 sqmm copper multistrand conductor 1100 volts grade multistrand unsheathed PVC insulated (Green colour cable used) cable for earth continuity wire connected from main earth through including PVC concelead conduit as required for surface/concilled including of all accessories complete all as specified and as directed. Note : Three runs of 6sqmm copper conductor and 1 run of PVC conduit shall be measured as one unit.
Material and labour for sub main wiring for main DBs to Sub DBs with standard copper conductor 1100 volts grade of size 4 sqmm two runs of multistrand unsheathed PVC insulated cable (Red colour cable used for live connection & Black colour cable used for neutral connection) and 4 sqmm copper multistrand conductor 1100 volts grade multistrand unsheathed PVC insulated (Green colour cable used) cable for earth continuity wire connected from main earth through including PVC concelead conduit as required for surface/concilled including of all accessories complete all as specified and as directed. Note : Three runs of 4sqmm copper conductor and one run of PVC conduit shall be measured as one unit.
Material and labour for power unit 20 A ,230V complete all as specified and as directed. Make Havells Cat No.AHLO202504 or equivakent make specified in P.S.
Material and labour for XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 volts grade,cross-sectional area 25 sqmm 2 Core complete all as specified and as directed.
Excavating in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth, and getting out for laying of cable in soft/loose soil complete all as specified and directed.
Material and labour for sand cushioning for protection of underground cable, consolidated and compacted with clean dry sand all as specified in SSR Part-I complete all as specified and as directed.
Material and labour for returning, filling in, including spreading levelling wtering and well ramming complete all as specified and as directed.
Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point in soft/loose soil complete all as specified and as directed.
Material and labour for laying of bricks common burnt clay building bricks, sub-class ‘B’ for protection of electric cable complete all as specified and as directed.
Material and labour for laying of GI tube 32 mm bore "medium grade" complete all as specified and as directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on complete all as specified and as directed.
Job No : BSA/KOL/SR(BLDG)/12/2021-22 Taking down Steel window and Ventilators of any size including Grill/Guard Bars etc complete all as specified and as directed by Engineer-in-charge.
Taking down door exc 1 Sqm and n exc 2 Sqm each etc complete all as specified and as directed
Demolition of brickwork including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles built in cement mortar. complete all as specified and as directed
Taking up or down 15mm dia steel water tubing and connections, and set aside for re-use or removal complete all as specified and as directed
Taking up or down 20mm steel tubing and connections, and set aside for re-use or removal. complete all as specified and as directed
Taking down existing flushing cistern any capacity and refixing the same at same place including replacement of flush pipe complete all as specified and as directed. (Note:- Rate to be qouted for taking down and refixing of cistern.)
Supplying and fixing 10 litres capacity PVC valveless, syphonic action type, flushing cistern, white colour, low level, white with inlet, ball valve, float and handle including brackets duly painted, 32mm dia PVC flush pipe complete all as specified and as directed by Engineer-in-charge.
Dismantling water tank capacity exc 500Ltrs but n. exc 1000Ltrs and removing from the site etc. complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed
Material and labour for Non-skid coloured ceramic floor tiles 7 to 8 mm thick area of each tile exc .11 sqm but n exc 0.18 sqm in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles .complete all as specified and as directed by Engineer-in-charge. (Note:- Screed bed shall be measured and paid Seperately under respective items of Sch "A')
Material and labour for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4) as in floors for laying of tiles complete all as specified and as directed by Engineer-in-charge.
Material and labour for Glazed ceramic coloured wall tiles of size 450X300X7mm to 8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles .complete all as specified and as directed by Engineer-in-charge. (Note:- Screed bed shall be measured and paid Seperately under respective items of Sch "A')
Material and labour backing coat/Screed bed or bedding layer of mortar 10 mm thick in cement mortar (1:3) as in dado/skirting complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class 'B' bricks built in cement mortar (1:6) straight or curved on plan exceeding 6 mtr mean radius and all as directed.
Material and labour for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4). complete all as specified and as directed
Material and labour for Rendering 15mm thick in cement mortar (1:6) on fair face of brick work or concrete surfaces and finished the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and labour for Rendering 15mm thick in cement mortar (1:4) on fair face of brick work or concrete surfaces and finished the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and labour for Rendering 5mm thick in cement mortar (1:3) on fair face of brick work or concrete surfaces as on ceiling and finished the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Supply and fixing for CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings as in walls, ceiling, floor, etc. complete all as specified and as directed.
Supply and fixing for CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings as in walls, ceiling, floor. etc complete all as specified and as directed.
Supply and fixing for 25mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair 15mm bore Brass CP bibcock fancy type with crutch or butterfly handle complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair 15mm bore Brass CP angular stopcock concealed type with crutch or butterfly handle complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair PVC connection 15 mm size pipe with PTMT nut of Length 600mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair vitreoues china wash hand basin, white, size 560mm x 410mm oval type counter type for bathroom, super white colour including provision and fixing of bolts, bottle Trap, CP Pillar tap 15mm fency type, connector pipe PTMT 15mm bore and 450mm long, 32mm PVC waste pipe, CP waste coupling complete all as specified and as directed.
Supply and fixing CP Towel Rail 600mm long fixed with and including Chromium plated brass screws and wooden/plastic cleats complete, fixed in wall complete all as specified and as directed by Engineer-in-charge.
Material and labour for Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket, guard and railing 60cm long etc. complete all as specified and directed.
Supply and fixing vitreous china white wash down water closet pan (Pedestal pattern) including PVC white seat close pattern flat bottom and with aluminium or CP hinging device (including fixing bolts but excluding flushing cistern and flush pipe) complete and making all necessary connections complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair CI Nahani trap with steel grating of 100mm dia, including jointing to waste pipe fixed in cement concrete, (1:2:4), type B1 (using 20 mm graded crushed stone aggregate). .complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Solid PVC plain colour frame of size 50mm x 47mm made out of 5mm Moulded/printed PVC sheet reinforced with M.S. Square tube, fixing in opening as per specification & drawing complete all as specified and as directed by Engineer-in-charge.
Supply and fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails MS frame shall be covered with heat molded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for top rail and bottom rail on either side and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/seated to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame at site as per specification and drawing. Complete all as specified and as directed.
Supply and fixing 150 mm long Aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 150 mm long Aluminium handles, cast type, anodised complete all as specified and as directed by Engineer-in-charge.
Supply and fixing as in repair 100 mm long aluminium butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and as directed by Engineer-in-charge.
Supply and fixing fixed type partly glazed, partly gauged. Solid PVC ventilator including 3mm thick frosted glass pane, 0.36mm dia & 1.4mm aperture stainless steel wire net, glazing clip, fastener etc complete all as specified and directed by Engineer-in-charge.
Supply and fixing for Powder coated aluminium sliding windows for three track with 5mm thick plain/ coloured glass fixed with powder coated aluminium standard beads/glazing clips having weight not less than 300gm per RM,locking arrangement etc and aluminium frame of size 64mmX45mmX1.55mm and shutter of section 20mm X40mm X1.55mm including taking down old steel windows with necessary all fittings complete all as per manufacturer's instructions and complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing 3.0 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with SS wire staples complete,all as specified and directed. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Mild Steel framed work such as grills, gratings, etc. with ends of bars shouldered and or riveted, or forged into spikes, framed guard bars, barred iron doors, railings and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-charge.
Material & labour preparation of new steel and iron surfaces of any description exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and as directed by Engineer-in-charge.
Material and labour for vitreous china bowl urinal flat back, size of 465 x 355 x 265mm white (minimum), with grating and union for discharge pipe including waste coupling and waste pipe etc complete all as specified and directed.
Supply and fixing in repair CP hand shower (faucet) fency type with one meter CP flexible tube with wall hook complete all as specified and as directed.
Supplying and laying of CPVC 80mm pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and as directed.
Material and labour for Rotational moulded polyethylene (three layer) water storage tank capacity 1000 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
Material and labour for preparation new plaster surfaces of brick or concrete surfaces and applying three coats of white wash on wall etc. complete all as specified and as directed.
Material and labour for one coat of white wash on old decorated surface of wall including preparation and necessary arrangement for working platform complete all as specified and as directed.
Material and labour for preparation new plaster concrete surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
Supply and fixing in repair 100 mm bore cast iron centrifugally cast (Spun) iron, spigot and socketed conform to IS-3989-1984 soil waste and vent pipes, in any length without ears with cement joints to walls after fixing on the wall with GI hook and including taking up/down of existing old pipe lines including fittings at any height complete all as specified and directed.
Supply and fixing 100 mm bore CI (Spun) branch pieces single (equal or unequal) ordinary or inverted or with parallel braches conform to IS-3989-1984 fitted with oval access doors complete all as specified and as directed.
Supply and fixing cast iron cowls, bore of pipe 100mm complete all as specified and as directed.
Material and labour for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like over and including 15mm thick cement mortar bedding (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engr-in-Charge.
Material and labour for concealed point wiring for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed multistranded copper conductor cable 1100 volts grade controlled by one No. one way switch including 1.5 sqmm PVC insulated (FR-LSH) unsheathed multistranded copper conductor cable 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit with all accessories and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting switch, socket and fan regulator, etc on 3mm thick hylum laminated/bakalite sheet cover after and including taking down of old existing point wiring including fixtures and fitting such as switch, ceiling rose, holders, socket, etc and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No 153 here-in-before but for one 5 pin 6/16 Amps switch socket combination on independent board with 2.5 Sqmm PVC insulated (FR-LSH) unsheathed copper cable 1100 volts grade and 2.5 sqmm PVC insulated (FR-LSH) copper cable as earth continuity conductor complete all as specified and directed.
Supply and fixing switch flush type 6 amps 230 volt single pole one way complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing 6/16 Amp switch socket combination multipurpose 2 in 1,5 pin, 230 volt flush type complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing ceiling rose surface bakelite three terminal 65 x 50mm complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing Exhaust fan AC single phase 230/ 240 V of size 300 mm sweep with blades, frame and louver including connection with suitable size flexible copper wire from fan to ceiling rose complete all as specified and directed.
Taking down of exhaust fan ,depositing the same to store for reuse and refixing the same after completion of false ceiling work including provision of cable from ceiling rose to fan complete all as specified and directed by the Engr - in - charge.
Supply and fix new generation LED batten fitting (4 ft) 20 W with extruded aluminium body, PC diffuser and inbuilt driver including necessary electric connection from ceiling rose to light fitting fitted complete all as specified and as directed by the Engr-in-Charge.
Rounaq Enterprise
Tirupati Buildcon Pvt. Ltd.
S.S.ENTERPRISE
DILIP CONSTRUCTION
M/S J S ENTERPRISES
BHARUKA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .