| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC H NO 66 DAKHINGAON PO KAHILIPARA PS DISPUR GUWAHATI 781019 | KAMRUP METRO | ASSAM | 781019 | ₹1.1 Cr | L1 | Accepted-AOC L1 |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 3 | Not Admitted-Fee/PreQual/Technical NOWAPARA PO PS CHHAYAGAON DIST KAMRUP ASSAM | KAMRUP | ASSAM | 781030 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
6 Feb 2020, 2:00 pmClosed
Commissioner, ASHB
Office of the Commissioner,ASHB
Construction and Renovation works of Haji Anfor Ali College, Hojai
2020_UDD_15962_1
ASHB/Tech/1165/2019
Open Tender
Civil Works
Works
365 days
Principal Haji Anfar Ali College, Doboka
Class I
3 documents required · 3 mandatory
₹5,000
Yes
Commissioner, Assam State Housing Board
₹2.4 L
Yes
Guwahati
3 Aug 2020
21 Jan 2020
10 Feb 2020
21 Jan 2020
6 Feb 2020
22 Jan 2020
24 Jan 2020
Amount
Construction of Classroom (Ground Floor) at Haji Anfar Ali College
Earth work in excavation for foundation trenches of walls, retain -ing walls, footings of columns, steps, septic tanks etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified.
I) Upto a depth of 2m below the existing ground level .
a) In ordinary soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.
(b) With hill sand obtained by truck carriage loading and unloading, and carriage to the site of work.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete.
b) 50mm thick
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.
(b) Using 25mm thick plank
Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
(ii) Using 25mm thick plank
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
(ii) Using 25mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.
(a) Floors etc. upto 200mm in thickness.
(ii) Using 25mm thick plank
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
(a).Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.
(I) In Sub-structure upto plinth level including dewatering if necessary
(b) In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)
(A) 112mm thick brick wall
(b) In cement mortar in proportion 1:5. (1 cement:5 sand)
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make
ii) Of size 600mmx600mm and above
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
c) In cement mortar 1:5
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(a) With sal wood
Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately )
B) With 1st class local wood (Gamari/Hollock/Bonsum )
(i) 40 mm thick.
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.
I . Plain grill
(c) Fixed to Brickwork/P.C.C/R.C.C.
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.
(a)2 Track sliding window
(i)6mm clear glass
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed.
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting.
(b). With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i) Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )
a) Sliding door bolts
i) 300mm x 16mm
b) Tower bolts
ii) 250mm x 12mm
c) Door handles
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
Providing and laying plain/reinforced cement concrete works using cement, coarse sand & 20mm down graded stone aggregate with cost of necessary form work including dewatering if necessary, and curing for reinforced cement concrete work complete as directed (Reinforcement will be measured and paid separately)
I) Using mixture machine
(A) In sub - structure up to plinth level
N) Without using admixture, plasticiser
(b) M20 or Prop. 1:11/2:3
iii) Suspended floor (Slab, balcony, staircase etc)
N) Without using admixture, plasticiser
(b) M20 or Prop. 1:11/2:3
Construction of Computer Centre (First Floor) at Haji Anfar Ali College
25 mm thick cement concrete topping 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 12 mm nominal size) finished with a floating coat of neat cement finish to be laid in panels including curing complete as directed.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
(ii) Using 25mm thick plank
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
(ii) Using 25mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.
(a) Floors etc. upto 200mm in thickness.
(ii) Using 25mm thick plank
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
Extra for each subsequent 1.0M height or part thereof beyond the initial height of 4.0M as mentioned in item no. 3.1.1
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)
(A) 112mm thick brick wall
(c) In cement mortar in proportion 1:6. (1 cement:6 sand)
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level.
(b) 75 mm thick brick/ R.B wall
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make
ii) Of size 400mmx400mm and above
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
c) In cement mortar 1:6
Extra over item no 6.2.1 to 6.2.3 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed.
ii) 15 mm thick plaster
c) In cement mortar 1:6
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(b) With 1st class Timber (Bonsun/ Sundi)
Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately )
B) With 1st class local wood (Gamari/Hollock/Bonsum )
(ii) 35 mm thick.
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.
I . Plain grill
(c) Fixed to Brickwork/P.C.C/R.C.C.
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.
(a)2 Track sliding window
(i)6mm clear glass
b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
c) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on old wall surface (one coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose or softened paint.
Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed.
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting.
(c). With ready mixed paint , Aluminium primer
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i).Surfaces over 100mm in width or girth.
a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )
a) Sliding door bolts
i) 300mm x 16mm
b) Tower bolts
ii) 250mm x 12mm
c) Door handles
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
Extra over item 18.1.1(a,b,c) for each subsequent floor or part thereof above first floor level.
Providing and laying plain/reinforced cement concrete works using cement, coarse sand & 20mm down graded stone aggregate with cost of necessary form work including dewatering if necessary, and curing for reinforced cement concrete work complete as directed (Reinforcement will be measured and paid separately)
I) Using mixture machine
B) In super structure up to 1st floor level
iii) Suspended floor (Slab, balcony, staircase etc)
N) Without using admixture, plasticiser
(b) M20 or Prop. 1:11/2:3
Extra for every subsequent floor above 1st floor on item no 32.1.(I)
Renovation of Library Building (Extension) at Haji Anfar Ali College
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00m below the existing ground level.
(a) In ordinary soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.
(b) With hill sand obtained by truck carriage loading and unloading, and carriage to the site of work.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete.
b) 50mm thick
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.
(b) Using 25mm thick plank
Columns, Pillars, Posts & Strut
(ii) Using 25mm thick plank
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
(a).Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.
(I) In Sub-structure upto plinth level including dewatering if necessary
(b) In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)
(A) 112mm thick brick wall
(b) In cement mortar in proportion 1:5. (1 cement:5 sand)
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make
ii) Of size 600mmx600mm and above
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
c) In cement mortar 1:5
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) pre-coated G.I. angle size 24mmx24mmx80mm thick fixed to the brick wall/ partition at the perimeter of ceiling with nylon sleeves and screws, at 610mm c/c. Then suspending main 'T' section (bottom pre-coated) size 24mmx38mmx0.70mm and 3600mm long from the soffit in one direction with the help of metal Rawl Plug. Soffit cleat and G.I. Rod 4mm diameter with galvanised level clip 1220mm c/c G.I. cross.
BPB Grid ceiling system with plain Gypboard Tiles 12.5mm thick.
Providing Iron Plastic Laminated corrugated coloured sheet Roofing at all levels including fitting and fixing galvanised J or L hooks, bolts and nuts of 8 mm diameter with Bitumen washer 35 mm x 35 mm x 3 mm and G.I. Diamond washer 40 mm x 40 mm x 3 mm complete excluding cost of roof truss, purlins etc. (Roof trusses, Purlins etc. to be measured and paid separately).
(b) 0.55 mm thick
Providing Colour Coated (Iron Plastic Laminated Sheet) Ridging including supplying and fixing necessary galvanised screws / washer etc. complete as specified and directed.
(B) 0.55 mm thick
(ii) 230 mm lapping
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(a) With sal wood
Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete.
Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately )
B) With 1st class local wood (Gamari/Hollock/Bonsum )
(i) 40 mm thick.
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.
I . Plain grill
(c) Fixed to Brickwork/P.C.C/R.C.C.
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.
(a)2 Track sliding window
(i)6mm clear glass
f) Distempering with dry distemper of approved brand and manufacture(two coats)and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after throughly brushing the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth.
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed.
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting.
(a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
f) Distempering with dry distemper of approved brand and manufacture(two coats)and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after throughly brushing the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth.
Painting one coat (excluding priming coat) on old wood and wood based surfaces with enamel paint to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping.
(i).Surfaces over 100mm in width or girth.
a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )
a) Sliding door bolts
i) 300mm x 16mm
b) Tower bolts
ii) 250mm x 12mm
c) Door handles
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.
a) TATA make Circular Hollow section- CHS of Grade YST-310 conforming to I.S. Specification : 1161-1998
Providing and laying plain/reinforced cement concrete works using cement, coarse sand & 20mm down graded stone aggregate with cost of necessary form work including dewatering if necessary, and curing for reinforced cement concrete work complete as directed (Reinforcement will be measured and paid separately)
I) Using mixture machine
(A) In sub - structure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
N) Without using admixture, plasticiser
(b) M20 or Prop. 1:1.5:3
B) In super structure up to 1st floor level
i) Vertical members like column, pillars, post, struts etc
N) Without using admixture, plasticiser
(b) M20 or Prop. 1:11/2:3
Renovation_Campus Development A) Boundary Wall at Haji Anfar Ali College
EARTHWORK IN EXCAVATION:
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00m below the existing ground level.
(b) In hard/ dense soil
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(I) Using Mixer Machine
(A) In substructure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
N) Without using admixture, plasticiser
a) M15 grade concrete or Prop. 1:2:4
(B) In super structure from plinth level up to 1st floor level.
i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc.
N) Without using admixture, plasticiser
a) M15 grade concrete or Prop. 1:2:4
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.
(b) Using 25mm thick plank
Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
(ii) Using 25mm thick plank
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.
(I) In Sub-structure upto plinth level including dewatering if necessary
(b) In proportion 1:4.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
(a).Brick on flat soling.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)
(A) 112mm thick brick wall
(a) In cement mortar in proportion 1:4. (1 cement:4 sand)
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
b) In cement mortar 1:4
Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats).
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
Campus Development B) Pond Protection Works at Haji Anfar Ali College
POND PROTECTION WORK
Dewatering of Pond
Dewatering of pond by using mechanical pump and discharge the pond water at drain complete as directed.
(As per market analysis)
Excavation for Structures
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Construction of Subgrade and Earthen Shoulders
Construction of subgrade and earthen shoulders with a pproved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1
(I) Private land 1x1x144.00x1.50x1.75 = 378.00
Granular Sub-base with Well Graded Material (Table 400.1)
(A) By mix in place method construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Tecnical Specification Clause 401.
(i) For Grading I Material
Bed 1x1x144.00x1.40x0.12 = 24.19
Plain / Reinforced cement concrete, inopen foundation complete as per drawing and technical specification including steel shuttering framework
A. PCC Grade M15
MASONRY WORK
Providing and laying cutain walls complete as per drawing and technical specification Clause 1304
i) Brick masonry in cement mortar (1:4)
Average width 1.20+0.30/2 = 0.75 m
CLASSROOM : HAJI ANFAR ALI COLLEGE
A. INTERNAL WIRING
Wiring for light/fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system, complete.
Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.
Short point up to 3.00 metre. length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in flat 19 mm ISI marked casing 'n' capping system.
200 mm x 250 mm x 60 mm deep (Nominal size
Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.
SWITCH SOCKETS
Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.
8 module type Metal
18 module type Metal
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.
8 module
18 module
Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
100 watt electronic modular 4 step speed control 2 - module type
FITTING AND FIXTURES
DISTRIBUTION
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make)
6 way SPN double door
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
B Series (ABB, Schneider MG, legrand, Hager make)
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
B Series (Schneider MG, legrand, Hager make)
EARTHING
Supply and drawing of earth continuity with 1.50 SQ mm single core flame retardant low smoke PVC insulated multistrand twisted copper cable (Green colour in the existing PVC conduits including making necessary connection as approved, specified and directed by the deptt.
COMPUTER CENTRE AT FIRST FLOOR : HAJI ANFAR ALI COLLEGE
INTERNAL WIRING
Wiring for light/fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system, complete.
Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.
Short point up to 3.00 metre. length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in flat 19 mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.
With 4 x 4 sq. mm. + earth continuity with 2x2.5 sq. mm. cable in 25 mm. ISI marked casing 'n' capping system.
With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in flat 32 mm ISI marked casing 'n' capping system.
Supplying and fixing 18 S.W.G sheet steel metal boxes of the following sizes in surface Wiring system with suitable size of 3 mm thickness phenolic laminated sheet cover on the front face of the boxes including painting etc. as required and specified by the department.
200 mm x 250 mm x 60 mm deep (Nominal size
Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.
SWITCH SOCKETS
Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.
1-2 module type Metal
8 module type Metal
18 module type Metal
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.
2 module
8 module
18 module
Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
100 watt electronic modular 4 step speed control 2 - module type
Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)
Energy efficient 5-star 1200 mm sweep Fusion 5 star (Havells or equivalent make)
DISTRIBUTION
Supplying including fitting and fixing bus bar chamber ( HPL/ GECO / or equivalent make) with 4 strips bus bar of length 350/450/600/900 mm made of aluminium alloy or wrought aluminium suitable for 100 amp capacity complete with all accessories including connection etc. as required complete
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
30mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make)
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make)
4 way TPN (4+12) double door
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt.
25 KA 415V 50 Hz 3P MCCB (Schneider, legrand, Siemens make)
Supplying with fitting and fixing TPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
B Series (Schneider neo break, C&S, Havells, Indo Asian, HPL, V-Guard or equivalent make as approved by the Deptt.)
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
B Series (Schneider MG, legrand, Hager make)
C Series (Schneider MG, legrand, Hager make)
EARTHING
Supply with installation & commissioning of readymade maintenance free CPRI approved technology G.I. CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 K and Advance Earth Pit cover (PV including excavation of earth pit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supply and drawing of earth continuity with 1.50 SQ mm single core flame retardant low smoke PVC insulated multistrand twisted copper cable (Green colour in the existing PVC conduits including making necessary connection as approved, specified and directed by the deptt.
UNDERGROUND CABLING AND TERMINATIONS
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .
25.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
SUPPLYING FITTING AND FIXING OF (DOWELLS/ COMET make) DOUBLE compression BRASS GLANDS WITH NICKEL - PLATED
FLAMEPROOF (CBF) Size: 20.5 - 23, 1 "
RENOVATION OF LIBRARY BUILDING (Extension): HAJI ANFAR ALI COLLEGE,
INTERNAL WIRING
Wiring for light/fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system, complete.
Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.
Short point up to 3.00 metre. length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in flat 19 mm ISI marked casing 'n' capping system.
Supplying and fixing 18 S.W.G sheet steel metal boxes of the following sizes in surface Wiring system with suitable size of 3 mm thickness phenolic laminated sheet cover on the front face of the boxes including painting etc. as required and specified by the department.
200 mm x 250 mm x 60 mm deep (Nominal size
Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.
SWITCH SOCKETS
Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.
18 module type Metal
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.
18 module
FITTING AND FIXTURES
DISTRIBUTION
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make)
6 way SPN double door
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
B Series (ABB, Schneider MG, legrand, Hager make)
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
B Series (Schneider MG, legrand, Hager make)
EARTHING
Supply and drawing of earth continuity with 1.50 SQ mm single core flame retardant low smoke PVC insulated multistrand twisted copper cable (Green colour in the existing PVC conduits including making necessary connection as approved, specified and directed by the deptt.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .