Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 CrAccepted-AOC | ₹19.7 Cr Quoted ₹21.7 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹24.3 CrRejected-Finance AT SEEPZ GATE NO 3 ANDHERI EAST IN K EAST WARD | MUMBAI | MAHARASHTRA | 400010 | ₹24.3 Cr | L2 | Rejected-Finance L2 |
Tender Value
₹19.7 Cr
EMD Value
₹9.8 L
Closing Date
18 Jul 2023, 4:00 pmClosed
Sanjay Kadam
VartakNagar Prabhag Samiti Thane Mahanagar P
Construction of Sangeet Vidyalay (Gurukul) of Bharat Ratna Lata Dinanath Mangeshkar in Vartaknagar Area of Thane Municipal Corporation.
2023_TMC_921504_1
TMC/PRO/PWD-HO/317/2023-24
Open Tender
Civil Works
730 days
VartakNagar Prabhag Samiti Thane Mahanagar P
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,900
₹9.8 L
City Engineer, Thane Municipal Corporation, 3rd Fl
24 Nov 2023
1 Jul 2023
20 Jul 2023
1 Jul 2023
18 Jul 2023
1 Jul 2023
10 Jul 2023
Amount
Trimming of grass, shurbs and weeds from the shoulders/berms and disposing off the same to suitable locations etc. complete
Cutting down trees including trunks and branches with girths above 60cm to 90cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
Excavation for foundation in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking or spreading as directed, dewaterin, preparing the bed for the foundation and necessary back filling, ramming, watering, including shoring and strutting as necessary complete. ( Spec.No. : Bd.A.1Page no 259/ CSR Page No.150
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means
Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 3.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary)
Providing soling using 80 mm size granite / quartzite / gneiss / trap metal in 15 cm. layer including hand packing filling voids with sand / grit, ramming, watering complete. (Spec. No. : As directed by Engineer-in-charge /Page No. 154)
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite / quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing cast in situ/ ready mix M20 grade cement concrete for head walls of CD work /retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer /concrete batch mix plant (pan mixer) with SCADA
Providing and laying in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying /pumping cover blocks,compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layersincluding watering and compacting etc. complete.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Lift Column
Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap /granite /quartzite /gneiss metal for R.C.C. beams and as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying /pumping, compaction and roughening the surface if special finishish to be provided and curing etc. complete. (Excluding reinforcement and structural steel). withfully automatic microprocessor based PLC with SCADA enable dreversible Drum Type mixer /concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Lift Beam
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and laying Cast in situ /Ready Mix cement concrete in M-25 of trap /quartzite /granite /gneiss metal for R.C.C. Waistslab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steelprops, laying /pumping, compaction, finishing uneven and honey combed surface with C.M. 1:3 of sufficient minimum thickness to give as mooth and even surface or roughening the surface if special finishish to be provided and curing etc. complete. (Excludinge in forcement, in cluding cover block). (Newly laid concrete shall be covered by gunny bag, plastic, tarpaulinetc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Typemixer /concrete Batchmixplant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
1st Floor to 2nd Floor
2nd Floor to 3rd Floor
3rd Floor to 4th Floor
4th Floor to Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast insitu/Ready Mix cement concrete in M-25 of trap /granite /quartzite /gneiss metal for R.C.C. Pardi of required thickness including steel entering, formwork, coverblocks, laying /pumping, compacting and rough ening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Panmixer) etc.complete.With fine aggregate (Crushedsand VSI Grade)
Providing and fixing in position HCRM /CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules .including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providingand laying in -situ M30 Grade unreinforced plaincement concrete pavement over aprepared sub base with 43 grade cement, coarse and fine aggregate (natural sand / VSI grade finely washed crushed sand) conforming to IS383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant / non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound / by providing cement vata in cement Mortar 1:8 @ 0.6 m X 0.6 m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75 mm and maintaining the same through out curing period by any other method approved by Engineer-in-charge. with fully automatic micro process or based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete.
Providing expansion joints in R.C.C. framed structure (atfloorlevel) with premoulded filler 25 mm thick and 3mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed.
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part3) -1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including strikingjoints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part3) -1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc.Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing internal cement plaster 12mm. Thick in Single coats in cement mortar 1:3 with out neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing internal cement plaster 6mm thick in a single coat in cement mortar 1:3 with out neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and applying gypsum plaster (with Gypsum materia l) with finishing with gypsum material in 10 to 13 milli meter thickness to previously plastered surface /or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc.complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kg. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
Providing and fixing 20 to 25 mm thick rough shahabad boxtype waterproofing treatment to vertical out side faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with waterproofing liquid Algae proof or other a like with one tile lift method, brushing the joints horizontally with cement slurry mixed with waterproofing liquid for width 30 to 35 mm and sloping coping over top most tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)
Providing and applying a base coat comprising of 1 Kilogram Polydee - MC and 1 Kilogram fresh cement after wetting the surface followed by drying the surface for 2days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2A : 1B)) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete.
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8to10 milli meter thickness (on a existing flooring) with bonding chemical and confirming to IS15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints, curing and clearing etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8to10 milli meter thickness (on a existing skirting) with bonding chemical and confirming to IS15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints, curing and clearing etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to10 mm thicknes sand confirming to IS.15622 -2006 (GroupBla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to10mm thickness and confirming to IS.15622 -2006 (GroupBla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram / Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand)
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Catbarybrown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and laying telephone black /Amba White / Cadburybrown / Rubyred / Ocean Brown granite stone of 18 to 20 mm thick for door frame / dado / window boxing etc. On C.M. 1:6 including filling joints with polymer base filler no sing / moulding the sharp edges wherever necessary, curing, etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Catbary brown / RBI red / Ocean Brown granite stone for tread sand risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing machine cut mirror polished 18mm to 20mm thick telephone black/AmbaWhite/Catbarybrown/RBIred/OceanBrown granite stone partition with full moulding the edges etc.complete. One side polish
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15mm (5 mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5 mm x 2) thick x 30 mm width on other style and bottom rails. Theinner panels laminated with 2 mm thick termiteproof, waterproof and fire resistant moulded PVC sheet with 2, 4, 6 design in different plain and / or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and / or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer incharge and manufacturers specification and drawing etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick (Toilet) as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teakwood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing in position U.P.V.C. (Unplasticized Poly Vinyl Chloride) having multi-chambered outer frame section (73 x 50) mm with an outer wall thickness of 2 mm & steel reinforcement, multi-chambered slider frame (73 x 60) mm with steel reinforcement, multi-chambered slider sash (46 x 82) mm with steel reinforcement designed to give optimum strength, 5mm thick tough ened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets, silicon sealent, sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Chargeetc. complete.
a) Supplying and fixing in position Aluminium four track sliding windows with outer frame made from section of over all size 122 mm x 45 mm, bottom section with drain section track weighing 1.83 Kilogram per metre and top and side section of size 122 x 31.75 mm weighing 1.15 Kilogram per One Running Metre with shutter sections made of 18 mm x 40 mm size having average weight of 0.6 Kilogram per One Running Metre (or as required size) with change in proportion ate weight, with 6mm float glass in three equal panels and alluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram /One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing 900 mm high S.S. 304 Grade Stainless steel railing with 40mm diameter and 1.5 mm thick attop, 40 mm diameter and 1.5 mm thick vertical supports space dat 1.5m center to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing 40mm diameter and 1.5mm thick Stainless steel hand railing in S.S.304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing 45 cm wide mildsteel ladder of 40mm x 6mm mildsteel flat stringers and steps of 18 mm dia. Mildsteel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 cm x 30 cm x 30 cm and painting the ladder complete. (AntiCorossive Paint)
Providing and fabricating structural steel work inrolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections with out connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases (NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram / 15l). plaster crack should be filled by Acrylic base Crack seal / Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise on site technical reports from the concerned company technologist.
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and applying Royal eLuxury Emulsion of approved make on internal wall surface as detailed be low Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10% or waterby 15 to 20% allowing to dry for 6 to 8hours After applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity.Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45 % or 65 to 70% by role Applying paints Royal eluxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller. (With prior approval of S.E.)
1st Floor
2nd Floor
3rd Floor
4th Floor
Terrace Floor
Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete.
2nd Floor
3rd Floor
4th Floor
Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings,inletpipe with stop tap,brackets for fixing the cistern,32mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing white glazed earthen ware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing 450 mm x 550 mm size superior type Belgium mirror with 16 mm dia. nickel plated towel rod etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing chromium plated towel rod 16 mm dia and 75cm. In length including all accessories complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing on walls/ ceiling /floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stackingt he same in PWD chowky or as directed etc. Complete
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing on walls/ ceiling /floor 25mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing on walls /ceiling /floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing 15 mm dia. Screw down bib /stop tap of brass including necessary socket union nut complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing 25 mm dia. Screw down bib / stop tap of brass including necessary socket union nut complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing screw down 15 mm dia. Wheeled stop tap of brass including necessary sockets/union nut complete
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing screw down for 25 mm dia. Wheeled stop tap of brass including necessary sockets /union nut complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing screw down for 50 mm dia. Wheeled stop tap of brass including necessary sockets/ union nut complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing push cock (Self closing tap) symet type of 15mm dia.including necessary socket, testing etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing 10 cm PVC nahani trap with grating etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and laying for 150 mm dia salt glazed stoneware pipe including fittings Such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.
Providing and fixing 50 mm dia meter water meter with non-return valve including strainer, sockets /union nut and including water meter box making locking arrangement and lock. [without chamber]
Providing andc onstructing Brick Masonry Inspection Chamber 90cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channel shalf round G.S.W. pipes, Brick Masonry, plastering from inside and air tight with 75 mm thick R.C.C. cover medium duty 140 Kilogram etc. complete.
Providing and fixing ISI1729/2002 grade 100mm dia Cast Iron Soil Pipes With lugs including plug bend necessary fittings such as bends, tees, single junction, double junction, slottedvent, off sets on wall orinto the ground including filling joints with cement mortar 1:2 proportion fixing on wall by means of galvanised Mild Steel bracket of 30x5mm plate and 8mm square rod with Galvanised Iron clamp with wash erasper design, drawing and as directed to keep pipe 50mm away from wall including necessary scaffolding and painting the exposed faces with one coat of red lead oil paint and two coats of white oil paint including removing the existing pipe if necessary and conveying and stacking in PWD Chowky or as directed by Engineer-in-Charge.
RWH - Recharge Pit Providing and constructing recharge pit of 2.0 m deep and 1.0m dia of pre-cast RCC rings with 6.5" diax 25m deep borewell at the floor of recharge pit including installation of combination of solid/ perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick side filling around outside of RCC rings (annul arspace) with 40mm size boulders including filling of recharge pit upto 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washedriver fineaggregate (naturalsand /crushed sand VSI gradefinely washed etc.) including netlonmesh between each gravel/ fine aggregate (naturalsand /crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, man hole frame & cover, PVCrungs, PVCend-caps, fittings etc. including arrange mentfor inlet & outlet pipe excavation & backfilling ass hownin the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge
Providing and fixing 75 mm dia stabiliser pipe /P.V.C. soil vent /waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters
Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes,weight and types and load bearing capacity as per EN-124,equivalent NECO with prior approval of concerned Superitending Engineer.
Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60millimeter thickness of having a strength of 400Kilogram/sq.m of approved quality and shape on a bed of crushed sand of 25to30 millimeter thick including striking joints and cleaning etc.complete. (using 100% crushed sand)
Providing and fixing 90cmx60cm Granite plate engraving 10cm. Height letter,figures including painting the lefters/figures with approved colour and shade complete
Designing, Providing & Installation of Wall mural related to freedom fighter, outside the jail wall. The material for this sculpture is Fibre/FRP . The Length of the mural should be minimum 15m with minimum height of 3 m, Size of the mural shall be in proportionate to the height of the sculpture. Thickness of FRP material should be 5-10mm. Including all cost of design, Making models (if any), making mural, inspection charges, Transportation, Fixing at site, Construction of Foundation in RCC- M20 Grade Concrete including Reinforcement(TMT/FE 500), Pedestal including all material required for fixing the mural, coating the pedestal with Coaltar Epoxy Coating, all Filling material upto the base of mural, polishing and painting of the mural, as directed by Engineer in Charge. (Variation in size off mural shall be +-10% in Length, Width and Height shall be permitted.) Inclusive all taxes Exclulding of GST .etc. Complete.
Conveying excavated material upto lid of 20KM
Providing and applying waterproofing treatment using acrylic polymer modified cement based waterproofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre/ Kilogram with two coat using approved chemicals form asonryandconcrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes,weight and types and load bearing capacity as per EN-124,equivalent NECO with prior approval of concerned Superitending Engineer.
Providing, laying and fixing P.V.C. pipe of 75mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete
BASIC TEST OF CEMENT Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness.
a) Water Absorption, Specific Gravity,Impact Value, Crushing Value.
b) Sieve Analysis.
c) Abrasion Value.
d) Flakiness Index & Elongation Index.
e) Stripping Value. (for Bituminous Work)
f) Soundness
a) Fineness Modulus ( Sieve Analysis ),Silt & Clay Content
b) Chloride & Sulphate Content.
c) Silt Factor.
a) Compressive Strength OF C.C. Cube (Set of 3 cubes)
b) Concrete mix design by Accelerated curing method. (By Accelerated curing method)
WATER PH Value, Sulphate & Chloride Content.
a) Upto 16 mm (Set of 3 Bars)
b) Above 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
SOIL / MURUM Plate Load Bearing Test.(Excluding Transportation)
Providing detailed layout plan of area in scale 1:500 including carrying out contour survey and detailed Engineering plane table Survey with the help of 24 Alidade. The dolomite are a measurement of the plot and structures, trees, over head line and underground service amenities within the area, with triangular method and giving detailesofthestructures,suchastotalarea,typeofbuildinganddistancefromallcornerstakingtrialpit0.5x0.5x2.00m.-2Nos.peracreandcollectionofrecordfromcitysurvey/D.I.L.R.authoritiesandauthentication.Theplanshallbetracedon75micronpolysterfilmandshallbesubmittedalongwiththreeAmoniaprints.Thecontourlevelsshallbemarkedat0.5Meterintervals.Note:-Theitemsincludes-1)Traversingworkwiththeodoliteandsteeltape.2)LevellingGridWorkoftheterrain.3)DetailedEngineeringSurveyandcontouringworkoftheterrain.4)Plottingwork.5)CollectionofRecord.a)upto1Acre
Providing and Fabrication and supplying Glass Porch with Stainless Steel hot dip galvanised brackets of required sizes, Sections, profies along with supplying high performance low E-coated glass DGU made op of 6 mm thick soft coated glass. All glasses to be toughwned soft coated glass to have a U-value range of 1.6 to 1.8 of any colour as approved by Enginner in charge
Providing and Fabrication and supplying Aluminium Movable Fins For potraying image of Bharat ratna Late Lata Dinanath Mangeshkar
Soft-Coated DGU - (14.3.1) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalization & drainage and protection against fire hazard including:(14.3.2) Inclusive of S.V.M. items for supplying of high performance low E coated glass DGU made up of 6mm thk. Soft coated glass +12mm air gap +6mm clear HS. All glasses to be toughned soft coated glass to have a U-Value range of 1.6 to 1.8 of any colour as approved by engineer in charge.
Providing Fabricating Parking Tower for 15 Cars With Electric Source, Voltage 220-440 V, Capacity 1800-2500 Kg/car, Body Material SS,MS, CI etc.
Providing and fixing Modular false ceiling of 600 x 600mm center to center and 13mm thick square mineral fiber board to be fixed on framework of alluminium sections for suspended false ceiling consisting of alluminium T2 ”x 1½” (50mm x 40mm) weighing 0.39 Kilogram / mat60 cms center center and fixed with ½” x ½” (15 x 15mm) flanges weighing 0.19 Kilogram/ msuspended on 6mm dia mild steel rod weighing 0.22 Kilogram/ m, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1½” (50mm x 40mm) weighing 0.39 Kilogram/ metc . ( all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.
Providing & Fixing in position, Acoustical Panelling made from Printed Fabric wrapped Compressed polyester fibre non woven 9mm panels on, 50 x 50 mm sal-wood frame of 600x600 c to c having wooden supports from wall of required length, in front of 1000 gsm synthetic wool 50mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete.SSR - 51.01
Providing & Fixing in position Acoustical Doors along with 150x150 mm teak wood frame, doors made from 50mm Teak wood frame 600 x 600 c to c filled with 1000Gsm synthetic wool 50mm thick and 3mm Tec sound from bothsides, 12mm water proof ply & veneer from both sides, including 150 mm heavy duty SS hinges (Geze/Dormaoreq.) 4no each leaf, with Door-closer (Dorma/Gezeo req.) including cost of required Cut-Outs, decorative mouldings / finishing- items / melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour, finishing etc complete SSR - 51.05
12 Seater Reading Table for Library @ 3600Lx1200Dx750HT Providing and Fixing 12 Seater Reading Table for Liberary @3600Lx1200Dx750HT Top:made from 25mm Prelaminated Particle board .Alledgesare covered by 2mm.Thk .PVC edge bands glued by hot melt glue applied by auto edge banding machine.Gable Ends :made from 25mm Prelaminated Particle board .Alledgesare covered by 2mm .Thk .PVC edgebands glued by hot melt glue applied by auto edge banding machine .Modesty panel:Made from 18 mm both side prelaminated particle boards.Alledges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.
Providing & Fixing Curviliner Workstation @ 1500/ 1500L x 600 /600D x750 HT Providing & Fixing Curviliner Workstation @ 1500 /1500L x600 /600D x750HT, Curvilinear Table Top @1500/ 1500Lx 600/ 600D:TOP tobe made of 25 mm thick Prelaminated particle board with PVC edgeband, GABLEEND tob emade of 25 mm thick Prelaminated particle board with PVC edgeband, KEY BOARD TRAY (WITHOUT MOUSE TRAY) :- Metal Powder Coated-Black Color, CPUTROLLEY :- Metal Powder Coated-Black Color, alongwith 3DRAWERPEDESTALUNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,
Acrylic tactile audio map Design, supply, fabrication and fixing of acrylic, nonglare, tactile audio pictorial building layout as per the approved size, design and make, having 6mm thick acrylic non glare base plate of the approved colour and non glare acrylic cut out symbol and uppercase Sans Serif letters of 12mm height ,raised 3mm above base plate and Grade 2/ Grade1 Braille to be integral with the sign face and be raised 0.5mm above base plate .The map to bei nstalled at the specified location as per accessibility standards, shall be oriented to the position of the viewer and to be installe data height of 800mm from the finished ground/ floor level and using the necessary hard ware specified by the manufacturer and to be installed up to the satisfaction of the engineer in charge
Directional signage Design, supply, fabrication and fixing acrylic multil ingual Braille (raiseddots) directional sign boards of size 6"x9"designed as per accessibility standards and having 4 mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letter s of height 15 mm raised not less than 0.8 mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15 mm rised not less than 0.8 mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each sign board to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the engineer in charge.
Floor Directories Providing and fixing acrylic multilingual Braille (raiseddots) ADA compliant modular floor directories system on all floors of size1.5' x 2' , showing the floor plan and the list of rooms on that floor, to be installed one ach floor near the staircase, designed as per standards and having 4mm thick blue acrylic base plate with Upper Case San Serif words and symbols made of white acrylic non glare cut out letter sof height 20mm raised not less than 0.8 mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare imported acrylic letters of height 15mm raised not less than 0.8 mm above base plate. Grade2/ Grade 1 Braille to be integral with the sign face and be raised 0.5 mm above base plate. Each directory to be fixed as per manufacturers specifications on the wall at the approved location at a height of 1200 mm from FFL and as per the directions by the engineer in charge.
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
Point wiring in PVC trunking (casing-capping) with 1.0 sqm FR grade copper wire with flush type switchand required accessaries as per specification No: WG-PW/SW
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and drawing of 2x1.5 sq.mm. FRLSH grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes and terminating on modular accessories in box for point wiring for independent plug as per specification No WG-PW/SW
Supplying and erecting modular type 5 pin socket with safety shutters 3 module socket 6A 240V AC supply, duly erected on provided plate and box with wiring connections complete duly erected.
Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting PVC slotted box trunking of size 100x100 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Providing and back filling ground enhancing compound 25 kg bag complete
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and laying rigid steel conduit 16 SWG 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No: WGMA/CC.
Supplying and erecting bulk head LED fitting max. 10W (including 10W LED)with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Supplying and erecting PVC box trunking of size 75x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX.
Supplying and erecting PVC box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX.
Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 18 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting regular/ standard model ceiling fan of 1400mm. Sweep complete erected in position as per specification no. FG-FN/CF
Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/1200/ 1400 mm. sweep, complete erected on provided switch board.
Supplying and erecting fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM with speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin 5A. plug top complete with moisture proof treatment and ‘E’ class insulation.
Supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM with speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 Volts single phase, 50 cycles A.C. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation
Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 70 to 120 sq mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 240 to 300 sq mm., with necessary material as per specification no. CB-JT/LT
Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m octagonal / conical GI pole).
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mmdia. G.l. Rod complete with all materials as per specification no. EAEP
SITC of Flood Light LED 120 Watt
Supply and erection of Hot dip galvanized Ring for installation of mini high mast suitable for 4 Nos of LED Flood lights. The outer dia of ring shall be 600 mm. The ring shall be of 50 mm dia B class pipe with three supports to Sleeve, the sleeve shall be of 500 mm length and 4 mm thick duly provision of 4 nos bols and shall be suitable to fit on Octagonal pole of 70 mm AF.
Providing PU paint to Octogonal poles as required of desired colour duly finished in an approved manner for 7 mtrs octogonal pole
Providing PU paint / Powder coating as required of desired colour duly finished in an approved manner for 600 mm dia mini high mast ring.
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
SITC of Street Light LED 60 Watt
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. APWCR/WC
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system.
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
Supplying and erecting midget type 3.0 litres instant type water heater of rustproof & shockproof ABS plastic body, high grade SS inner tank & 3kW heating element with corrosion & hard water protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, function valve) complete with 6.5 bar pressure withstanding capacity 230/250V, 50Hz, A.C. supply with inlet and outlet, with 3 core PVC flexible copper wire leads duly tested and marking sr. no. and date of erection complete
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 320 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 54.89 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 480 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 250 kVA up to 320 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
Providing & erecting 4 Pole MCCB, 415V, 800A, rated short-circuit breaking capacity 50 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB, 415 V,63/ 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 630A up to 800A MCCB.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying and erecting terminal spreaders suitable for 4 pole, above 630A up to 800A MCCB (Set of 8)
Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 250A MCCB (Set of 8)
Providing and installing of Cu links of 50 sq.mm with copper lugs for connecting the switchgear to Busbars
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
Supplying and erecting 250 kVAr, 3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC
Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 400A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 800A having 100mm (Width) X 5 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 400A having 50mm (Width) X 5 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB
S & E of aluminium strip to provide the support for the connectors
Supplying and erecting enamel iron G.I. sheet 1.25mm (18 gauge) caution board of size 200 x 150 mm. as per I.S. 2551 of 1982 in Marathi and Hindi erected at position.
Providing Required Hardware Like good quality and Various Sizes of Nut , Bolt ,Washer ,Spring washer Etc for Exiting Electrical panels for connecting Cables Etc.
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel/distribution boards / pipe as per specification no. CBLT/ CU
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying and erecting SS enclosure for MCCB suitable for up to 100A MCCB.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 10 Passenger/680Kg · Floors :- G+4 floor (5 Stops/5 Landings) · Travel :- 3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of 1100 mm wide x 1400 mm deep x 2250mm high · Lift shaft available having clear size of 2000 mm wide x 1800mm deep. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
Supply, Installation, Testing and Commissioning of 8 Zone Microprocessor base conventional type fire alarm control panel includes power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. Main product Make of Agni/ Apollo/Ravel / or Equivalent
Supply, Installation, testing & commissioning of conventional type smoke Detector complete . to be installed under / above false ceiling, roof and concealed space, etc. Smoke Detectors with Base Make of Agni/ Apollo/Ravel or Equivalent
Supply, Installation, testing & Commissioning of conventional Hooter Make of Agni/ Apollo/Ravel or Equivalent.
Supply, Installation, testing & commissioning of conventional manual call point complete with push button, enclosed in box with provision for cable or conduit coupling. The unit to be painted fire red outside, Make of Agni/ Apollo/Ravel or Equivalent
Supplying and erecting XLPE armoured cable 2 core 1.5 sq. mm FRLS copper conductor complete erected on wall / celling as per specification
Supply, Installation, testing & ommissioning of multi sensor heat detector with smoke and heat combination (RoR + fix temperature) with base on back box, necessary connections complete as per specification no. FF-FAS/HD
Supply, Installation, Testing and Commissioning of Response indicator
SITC of Power Coated M.S. Junction box for Smoke Detector
Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
Supplying, erecting, testing and commissioning rust free microphone table stand of chrome plating/powder coating or S.S. material, up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete.
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
SITC of 40-Input, 25-Bus Digital Rack Mixer with 32 input channels, 8 aux channels, 8 FX return channels, 16 aux buses, 6 matrices, main LRC 16 Programmable Midas Preamps, USB Audio Interface facility to connect with iPad/iPhone if required, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Compact 40-Input, 25-Bus Digital Mixing Console with 32 input channels, 8 aux channels, 8 FX return channels, 16 aux buses, 6 matrices, main LRC, 16 Programmable Midas Preamps, 17 Motorized Faders,-Channel LCD's, 32-Channel Audio Interface Facility to connect with iPad/iPhone if required, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Stage Box with 8 Remote-Controllable Midas Preamps, 8 Outputs, AES50 Networking and ULTRANET Personal Monitoring Hub,(Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of 2 X 6 Loudspeaker Manegement System, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Premium 12-Input Mic/Line Rack Mixer with XENYX Mic Preamplifiers, British EQ's and Multi-FX Processor,(Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
SITC of Wireless Handheld Microphone: UHF Wireless Cardioid dynamic handheld microphone system with Frequency Response of 100 Hz to 15 kHz (+1 dB, -3 dB), RF Sensitivity 20 dBuV at 60 dBA S/N ratio (50Ω termination), Total Harmonic Distortion <1.0% (at 1 kHz, ±20 kHz deviation) , Dynamic Range > 110dB , on/off switch operating range 100 mtrs , RF Power Output High: 30 mW, Low: 10 mW (switchable) at 50 Ω , Multiple band with 10 channels on each band ; maximum Output level XLR / Balanced: +9 dBV & 6.3 mm (¼"") / Unbalanced: +4 dBV,(Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Wireless Headworn Microphone: UHF Wireless Headworn Microphone Frequency Response of 100 Hz to 15 kHz (+1 dB, -3 dB), RF Sensitivity 20 dBuV at 60 dBA S/N ratio (50Ω termination) , Total Harmonic Distortion <1.0% (at 1 kHz, ±20 kHz deviation) , Dynamic Range > 110dB , on/off switch operating range 100 mtrs , RF Power Output High: 30 mW, Low: 10 mW (switchable) at 50 Ω , Multiple band with 10 channels on each band ; maximum Output level XLR / Balanced: +9 dBV & 6.3 mm (¼"") / Unbalanced: +4 dBV, Equivalent to model no. ATW-2110b + PRO92CW of Make Audio Technica
SITC of Gooseneck Microphone with table stand On Dias : Cardioid Condenser Gooseneck Microphone. with Frequency Response 30-20,000 Hz; Open Circuit Sensitivity: –39 dB (11.2 mV) re 1V at 1 Pa, Impedance 250 ohms or better completew with Foam Windscreen. Output Connector Integral 3-pin XLRM-type, Maximum Input Sound Level 139 dB SPL, 1 kHz at 1% T.H.D.Anti-Shock Microphone Stand with on/off Switch, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Wired Instrument Microphone :Element Dynamic, Polar Pattern Hypercardioid, Frequency Response 80-17,000 Hz, Open Circuit Sensitivity –56 dB (1.5 mV) re 1V at 1 Pa, Output Connector Integral 3-pin XLRM-type. (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Professional Battery/Phantom Powered DI-Box, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of 1100 Watt 2 Way Full Range Powered Loudspeaker with KLARK TEKNIK DSP Technology; 1x12" LF driver, 1 x 1" HF driver, Frequency Response (±3 dB) 50 Hz–18 kHz, Frequency Range (-10 dB) 45 Hz–20 kHz; 90° H x 60° V Dispersion; Maximum SPL 128 dB peak, Equalisation Bass: ±6 dB @ 80 Hz, Treble: ±6 dB @ 12 kHz; 6 x M10 rigging points with Flying arrangement for Loudspeaker, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of 2200 Watt 15" Band pass Powered Subwoofer with KLARK TEKNIK Technology, Frequency Response (±3 dB) 45 Hz–100 Hz; Frequency Range (-10 dB) 35 Hz–150 Hz, Maximum SPL 134 dB peak, constructed from Birch plywood, screwed and glued, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Fill / Stage Monitor : 600 Watt 2 Way Full Range Powered Loudspeaker with KLARK TEKNIK DSP Technology, 1 x 10" LF driver,1 x 1" HF driver, Frequency Response (±3 dB) 55 Hz–18 kHz, Frequency Range (-10 dB) 50 Hz–20 kHz, 90°H x 60°V dispersion, Maximum SPL 126 dB peak,(Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Active 300-Watt 2-Way 8" PA Speaker System with Wireless Option,Ultra-low noise Mic/Line input , 2-band EQ plus integrated sound processor,8" LF, 1" Phelonic driver,Frequency Range(-10dB): 55 Hz to 20 kHz,2.8 kHz Crossover Frequency, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of 8-Channel High-Power Headphones Mixing and Distribution Amplifier,(Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Universal Control Surface with 9 Touch-Sensitive Motor Faders, LCD Scribble Strips and Ethernet/USB/MIDI Interface. 9 fully automated and touch-sensitive 100 mm motorized faders. 8 dynamic LCD Scribble Strips for instant overview of track names and parameters. Built-in 2x2 USB MIDI interface for direct connection to Mac* or PC computers and one external MIDI device. 92 dedicated illuminated buttons for direct access of key functions. 2 dedicated footswitch connectors and one foot controller input for external remote control. 2-port powered multi-TT USB hub for connecting additional controllers, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Professional Studio Monitor Headphones, Closed Back- 40mm Driver, Frequency Response- 15 - 22,000 Hz, Maximum Input Power- 1,300 mW at 1 kHz, Sensitivity- 96dB, Impedance- 47 Ohms, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Professional Studio Monitor Headphones, Closed Back- 45mm Driver, Frequency Response- 15 - 28,000 Hz, Maximum Input Power- 1,600 mW at 1 kHz, Sensitivity- 99dB, Impedance- 38 Ohms, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Cardiod Condensor Microphone: captures the full, expressive character of a sound source, no matter how loud or how soft. Four exquisitely matched ultra-thin diaphragms function together (with outputs proprietarily summed) as Audio-Technica's largest-ever element. Maximum Input Sound Level- 148 dB SPL, Noise- 6 dB SPL, Signal-to-Noise Ratio- 88 dB, 1 kHz at 1 Pa including shockmound & protective carrying case, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Cardioid Condenser Instrument Microphones: two of Audio-Technica’s premier condenser instrument microphones in a stereo pair pack. Maximum Input Sound Level- 149 dB SPL, 1 kHz at 1% T.H.D., Noise- 8 dB, Signal-to-Noise Ratio- 86 dB, 1 kHz at 1 Pa, including clamp, windscreen, & Protective case, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Cardioid Condenser Instrument Microphones: two of Audio-Technica’s premier condenser instrument microphones in a stereo pair pack. Maximum Input Sound Level- 149 dB SPL, 1 kHz at 1% T.H.D., Noise- 8 dB, Signal-to-Noise Ratio- 86 dB, 1 kHz at 1 Pa, including clamp, windscreen, & Protective case,(Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
SITC of Smart Active Monitor System, Minimum Diffraction Coaxial (MDC™) Driver Technology: SPL- 118dB, frequency Response- 30 Hz- 43kHz (-6dB), Amplifier Power- 700 W Bass (Class D) + 150 W Midrange (Class D) + 150 W Treble (Class D), Driver Dimesnsion: 2 x H 5 13/32 x W 10 11/32 in Bass + 5 1/8 in Midrange + 31/32 in Treble (in inches), Equivalent to model no. 8361 of Make Genelec
SITC of Studio Subwoofer: Delivering high SPL and extended LF response, the 7380A offers power, clarity and flexibility in equal measures. Active Crossovers & Bass Management System: SPL- 119dB, Frequency Response- 16Hz-100Hz (-6dB), Driver Dimension- 15" in Bass, Amplifier Power- 800 W Bass (Class D), (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound)
Kit for System Auto Calibration
SITC of 180-Watts Mixing Amplifier,(Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound/EV/Bosch)
SITC of 30-Watts Cabinet Speaker,(Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound/EV/Bosch)
SITC of Wireless Handheld Microphone, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound/EV/Bosch)
SITC of Wireless Head Worn Microphone, (Makes-TOA / Atlona / Biaamp / Behringer / Audiotechnica / Genelec / Midas / Turbosound/EV/Bosch)
Supplying, installing, testing & commissioning cassette type room Air conditioning unit 2.8TR to 3.3TR capacity with refrigerant R32/R410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, dust filter, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing & commissioning cassette type room Air conditioning unit 4TR to 4.4TR capacity with refrigerant R32/410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, minimum dust filter, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete.
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater/AC system
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supply Installation Testing & commissioning Of 4MP Network IR Dome/ Bullet camra ,Smart IR ,Optical glass window with higher light transmittance, 3D DNR (Digital Noise Reduction)ONVIF Conformance,Structure.WDR 120 or Above Wide temperature range: -35°C to 60°C31°F to 140°F)IP66, Lens 3.6mm/4 mm,Angle of view (H): 80.5°Day/Night ,IR Range Up to 30m (98 ft) WDR Digital Max. Resolution 1920×1080,ROI Supported,vedio Compression H.265/MJPEG OSD Up to 8 OSDs, Power12 V DC, or PoE
Supply Installation Testing & commissioning Of Network Video Recorder 32 channel input,Support 2-ch HDMI Up to 12 Megapixels resolution recording, Support RAID 0, 1, 5, 6, 1&,8 SATA HDDs, Up to 8TB for each HDD, Support N+1 Hot spare, Support for 12V Power output, HDMI/VGA Output, Recording Resolution, Resolution 12MP/6MP/5MP/4MP/ 3MP/1080p/960p/720p/D1/2CIF/CIF, Compression H.265/H.264, 8 SATA interfaces,Capacity up to 8TB for each HDDs, Array Type RAID 0, 1, 5, 6, 10.
Supply Installation Testing & commissioning of 43"TV Equivalent to:- LG
Supplying & erecting UPS of 1 KVA capacity complete with standard features, along with necessary SMF batteries for 20 mins. batterv backup
Supplying, erecting, testing and commissioning of 2kVA capacity online pure sine wave, with backup time. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
Supply Installation Testing & commissioning of 8000 GB Hard Disk for video Surveillance Equivalent to:- Western Digital /Seagate
Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete
Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch,10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete.
Supply, Installation, Testing UTP Connector (RJ-45) as per specification No.WG-NAS/UTPC.
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
Second Year Comprehensive Maintenance of all electrical works (5% of Estimate Cost)
Third Year Comprehensive Maintenance of all electrical works (10% rise on Second Year Maintenance Cost)
Fourth Year Comprehensive Maintenance of all electrical works (10% rise on Third Year Maintenance Cost)
Fifth Year Comprehensive Maintenance of all electrical works (10% rise on Forth Year Maintenance Cost)
Spark Civil Infraprojects
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid