| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35 LAccepted-AOC | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹38.7 L+₹2.3 L (6.18%)Rejected-Finance 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹40.3 L+₹3.8 L (10.5%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹40.4 L+₹3.9 L (10.6%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹41.3 L+₹4.8 L (13.1%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
16 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
REPAIRS MAINTENANCE OF LT SUPPLY LINES PANELS AND ALLIED WORKS AT CENTRAL AREA AT AGE EM I UNDER GE CENTRAL KIRKEE
2022_MES_539729_1
8678/E8 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KIRKEE
Class D Category b(i)
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹96,000
Yes
1 Sept 2022
21 Jul 2022
18 Aug 2022
21 Jul 2022
16 Aug 2022
4 Aug 2022
21 Jul 2022 - 3 Aug 2022
60 days
Amount
Excavation in trenches n.exc. 1.5m wide and n.exc. 1.5m in depth for laying of pipe and getting out in soft loose soil complete all as specified and directed.
All as per Sl Item No. 1 above but in soft/disintegrated rock.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc.25cm thick complete all as specified and directed.
Removing of excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed.
Material and labour for plain cement concrete (1:3:6), type C2, using 40mm graded stone aggregate as in foundation for filling in, mass concrete for foundation of pole, transformer, panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and as directed.
Material and labour for plain cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and as directed
Material and labour for stone dust for cousioning of UG cable/ at cable trenches inside substation bulding etc., complete all as specified and as directed
Material and labour for brick protection with sub class 'B' brick for UG cable all as specified and directed.
Dismantling taking out carefully old / unserviceable UG cable of any type, any size from trenches / poles / ducts / LT panels after dismantling ends from over head conductors / MCCBs / joint boxes for relaying / refixing or carrying to store for Sch of Credit complete all as specified and as directed.
Materisl and labour for fixing or passing through pipe, laid in trenches or fixed to pole / wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq.mm 2 core with required aluminium cable lugs complete all as specified and as directed.
All as per Sl Item No. 10 here-in-before but 10 sq.mm 2 core.
All as per Sl Item No. 10 here-in-before but 16sq.mm 2 core.
All as per Sl Item No. 10 here-in-before but 10 sq.mm 4 core.
All as per Sl Item No. 10 here-in-before but 16 sq.mm 4 core.
All as per Sl Item No. 10 here-in-before but 25 sq.mm 3.5 core.
All as per Sl Item No. 10 here-in-before but 50 sq.mm 3.5 core.
All as per Sl Item No. 10 here-in-before but 70 sq.mm 3.5 core.
All as per Sl Item No. 10 here-in-before but 95 sq.mm 3.5 core.
All as per Sl Item No. 10 here-in-before but 120 sq.mm 3.5 core.
Dismantling taking out broken / worn out steel pole of 8.5 to 9.0 mtr long and kepping aside for refixing or carrying to store for credit complete all as specified and as directed.
Material and labour for steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws conforming to IS : 2713 and made out of structural steel tube conforming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified for type 410 SP-31 (9 mtr long) complete all as specified and as directed.
Dismantling and taking down old/un serviceable cross arms, bracing, supports etc complete for reuse at site or carrying to store for sch of credit all as specified and as directed.
Material and labour for rolled mild steel as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
Dismantling and taking down old / un serviceable ACSR conductor of any size complete for reuse at site or carrying to store for Sch of credit all as specified and as directed.
Material and labour ACSR conductor including jointing with existing conductor, straining on LT pole and proper fastening to pin / shackle insulators with aluminium binding wires and required jumpering connection complete all as specified and as directed.
Dismantling and taking down old / un serviceable insulator of any type, any size from pole / stay for reuse at site or carrying to store for sch of credit complete all as specified and as directed.
Material and labour pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade all as specified and as directed.
Material and labour shackle type, porcelain vitreous white, brown or green insulator including galvanised mild steel straps, washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 volts grade complete all as specified and as directed.
Material and labour loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm dia all as specified and as directed.
Material and labour for stay assemby using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I including dismantling un serviceable one all as specified and as directed. NOTE :- Clamps, loop insulator, earth work, PCC shall be measured separately.
Material and labour for stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding including dismantling taking down unserviceable one all as specified and as directed.
Supply and fix cradle hexagonal /rectangular fabricated with galvanised steel wire not less than 4mm dia on pole including dismantling taking out un serviceable cradle guard all as specified and as directed.
Supply and fix earth continuity wire using GI wire not less than 4mm dia on pole including dismantling / taking out un serviceable GI wire all as specified and as directed.
Material and labour for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 6.00 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 6.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 25x4 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC (1:3:6), type C-2 with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI strip 25x4mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in and removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion all as specified and as directed.
Material and labour for restraining of overhead ACSR conductor of any size of 4 wire 35-45 mtr span on pole after disconnecting all jumpering connection and binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and as directed.
Material and labour for restraining of ACSR conductor of any size of 2 wire 35-45 mtr span on pole after disconnecting all jumpering connection and binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and as directed.
Material and labour for restraining of GI cradle guard hexagonal / rectangular of any size 35-45 mtr span on pole after disconnecting all bindings on cross arms and redoing all bindings providing required T&P all as specified and as directed.
Material and labour for restraining of GI earth wire of any size 35-45 mtr span on pole after disconnecting all bindings on cross arms and redoing all bindings including providing required T&P all as specified and as directed.
Cutting / trimming of tree branches around 3.00 mtr distance from conductors of HT over head line of span of 40 to 50 meters including removing of creepers etc from poles all as specified and as directed.
Cutting / trimming of tree branches arround 3.00 mtr distance from conductors of LT over head line of span up to 40 meters including removing of creepers /vegitation etc from poles all as specified and as directed.
Supply and fix sheet steel enclosure of size 400 x 300 x 400mm made out of 3mm thick MS sheet hinged door and locking arrangements, painting (inside and outside) with epoxy powder coated including fixing in position with the following accessories internally pre wired and testing complete all as directed :- (a) Time switch, Maxi Rex 4QT-daily, 240V, AC, base mounting, Legrand 6499-15 – 01 No. (b) 3 pole power contactors, type ML-3 of L&T or equivalent – 01 No. (c) Toggle switch, single pole 2 way - 01 No. (d) Bakelite base brass terminal connector block 8 way 40 Amps capacity-1 No. (e) MCB TPN 40 Amps of Legrand / L&T-1No and fixed to pole / wall with clamp, nuts, bolts washers and testing complete including dismantling / taking down unserviceable switch fuse complete all as specified and as directed.
Material and labour heat shrink end joint indoor/outdoor joint kit, LT 1100 volts grade, 10-16 sq.mm, 2 core, all as per Raychem, Cat No-EPKT0003 or techno commercially equivalent of M-Seal/3M complete all as specified and as directed.
Material and labour heat shrink end joint indoor/outdoor joint kit, LT 1100 volts grade, 25-50 sq.mm, 3.5 core, all as per Raychem Cat No-EPKT0019 or techno commercially equivalent of M-Seal/3M complete all as specified and as directed.
Material and labour heat shrink end joint indoor/outdoor joint kit, LT 1100 volts grade, 70-150 sqmm, 3.5core, all as per Raychem, Cat No-EPKT0035 or techno commercially equivalent of M-Seal/3M complete all as specified and as directed.
Material and labour heat shrink end joint indoor/outdoor joint kit, LT 1100 volts grade, 185-300 sq.mm, 3.5 core, all as per Raychem, Cat No-EPKT0051 or techno commercially equivalent of M-Seal/3M complete all as specified and as directed.
Material and labour heat shrink straight through joint out door type joint kit, LT 1100 volts grade, 10-16 sq.mm, 4 core, all as per Raychem, Cat No-EPKJ0123 or techno commercially equivalent of M-Seal/3M complete all as specified and as directed.
Material and labour heat shrink straight through joint outdoor type joint kit, LT 1100 volts, grade 25-50 sq.mm, 3.5 core, all as per Raychem, Cat No-EPKJ0130 or techno commercially equivalent of M-Seal/3M complete all as specified and as directed.
Material and labour heat shrink straight through joint, outdoor type kit, LT 1100 volts grade, 70-150 sq.mm, 3.5 core, all as per Raychem, Cat No-EPKJ0137 or techno commercially equivalent of M-Seal/3M complete all as specified and as directed.
Material and labour heat shrink straight through joint, outdoor type joint kit, LT 1100 volts grade, 185-300 sq.mm, 3.5 core, all as per-Raychem, Cat No-EPKJ0144 or techno commercially equivalent of M-Seal/3M complete all as specified and as directed.
Material and labour for painting of steel pole any type up to 7.5 mtr height above ground level including cross arms, clamps, stay clamps etc with two coats of aluminium paint after surface preparation all as directed by Engr-In-Charge.
Material and labour for numbering of HT/LT poles serially with letter / number size width and height up to 40 mm in situ with white paint on black back ground complete all as specified and as directed.
Material and labour GI tubing light grade 40mm bore, on pole /wall with necessary clamps, nuts, bolts and washers / under road cross ISI marked, for cable protection including taking out old pipes all as specified and as directed.
Material and labour GI tubing light grade 50mm bore on pole /wall with necessary clamps, nuts, bolts and washers / under road cross ISI marked, for cable protection, including taking out old pipes all as specified and as directed.
Material and labour GI tubing light grade 80mm bore,on pole /wall with necessary clamps,nuts,bolts and washers / under road cross ISI marked, for cable protection including taking out old pipes all as specified and directed.
Material and labour for jumper connections of length up to 1.50 mtr with existing size and guage of ACSR, binding with existing conductors for LT OH lines complete as directed by the Engr-In-Charge.
Material and labour for danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 1100 volts, 25 x 20 cm size including taking out defective danger boards all as specified and as directed.
Material and labour for danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 11000 volts, 25 x 20 cm size including taking out old danger boards all as specified and as directed.
Supply and errect cast Iron HT/LT cable route indicator round shaped 120 mm dia 8 mm thick duly embossed with MES HT/LT Cable fixed on flat iron 25X3 mm thick 300 mm long and grouted in PCC complete all as specified and as directed. NOTE:- PCC shall be measured separately.
Material and labour for rigid PVC line spacer, U-shaped, spriral type, suitable for 2 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade complete all as specified and as directed. MAKE :- Shree Balaji Power Plast/Goyal Power Plast
Material and labour for rigid PVC line spacer, U-shaped, spriral type, suitable for 4 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade complete all as specified and as directed. MAKE:- Shree Balaji Power Plast/Goyal Power Plast
Material and labour for aluminium cable lugs of size 50 sq.mm flat head in aluminium conductor / cable fixing with nuts, bolts & washers to junction point all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints.
Material and labour for aluminium cable lugs of size 70 sq.mm flat head in aluminium conductor / cable fixing with nuts, bolts & washers to junction point all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints.
Material and labour for aluminium cable lugs of size 95 sq.mm flat head in aluminium conductor / cable fixing with nuts, bolts & washers to junction point all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints.
Material and labour for aluminium cable lugs of size 120 sq.mm flat head in aluminium conductor / cable fixing with nuts, bolts & washers to junction point all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints.
Material and labour for aluminium cable lugs of size 150 sq.mm flat head in aluminium conductor / cable fixing with nuts, bolts & washers to junction point all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints.
Material and labour for aluminium cable lugs of size 240 sq.mm flat head in aluminium conductor / cable fixing with nuts, bolts & washers to junction point all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints.
Material and labour for aluminium cable lugs of size 300 sq.mm flat head in aluminium conductor / cable fixing with nuts, bolts & washers to junction point all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints.
Material and labour for MCCB, 4 pole, 36 KA braking capacity, Ics = 100%, Icu as per IEC 60947-2, with thermal magnetic release, 400 Amps, including dismantling / taking down un serviceable one, complete all as specified and as directed.
Material and labour for MCCB, 4 pole, 36 KA braking capacity, Ics = 100%, Icu as per IEC 60947-2, with thermal magnetic release, 200 Amps, including dismantling / taking down un serviceable one, complete all as specified and as directed.
Material and labour for MCCB, 4 pole, 36 KA braking capacity, Ics = 100%, Icu as per IEC 60947-2, with thermal magnetic release, 160 Amps, including dismantling / taking down un serviceable one complete all as specified and as directed.
Material and labour for MCCB, 3 pole, 35 KA braking capacity, Ics = 100%, Icu as per IEC 60947-2, with thermal magnetic release, 200 Amps, including dismantling / taking down un serviceable one complete all as specified and as directed.
Material and labour for MCCB, 3 pole, 35 KA braking capacity, Ics = 100%, Icu as per IEC 60947-2, with thermal magnetic release, 160 Amps, including dismantling taking down un serviceable one, complete all as specified and as directed.
Material and labour for MCCB, 3 pole, 16 KA braking capacity, Ics = 100%, Icu as per IEC 60947-2, with thermal magnetic release, 125 Amps, including dismantling / taking down un serviceable one complete all as specified and as directed.
Material and labour for MCCB, 3 pole, 16 KA braking capacity, Ics = 100%, Icu as per IEC 60947-2, with thermal magnetic release, 100 Amps, including dismantling taking down un serviceable one complete all as specified and as directed.
Material and labour for MCCB, 3 pole, 16 KA braking capacity, Ics = 100%, Icu as per IEC 60947-2, with thermal magnetic release, 63 Amps, including dismantling taking down un serviceable one complete all as specified and as directed.
Material and labour for MCCB, 3 pole, 16 KA braking capacity, Ics = 100%, Icu as per IEC 60947-2, with thermal magnetic release, 40 Amps, including dismantling taking down un serviceable one complete all as specified and as directed.
Material and labour for 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 10 sq.mm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia suspension GI wire from OH conductor to building including dismantling / taking down unserviceable one all as specified and as directed.
All as per Sl Item No. 77 above but size of cable 6 sq.mm
All as per Sl Item No. 77 above but size of cable 4 sq.mm
Labour for finding of fualt in UG cable laying in trenches with fault finding machine, including exacavtion, refilling, returning all as specified and as directed by Engr-in-Charge. NOTE :- Joint kit will be measure separately in appropriate items of this BoQ.
Design, fabricate, supply, testing and commissioning of factory made LT panel board, out door type, fabricated made out of 3 mm thick CRCA steel sheet for outer body double door and 2.00 mm thick CRCA sheet for inner partition walls, independent cabinet with cabinet doors for MCCB's , bus bars, cable trays, metering equipment vertical type, floor mounted, minimum IP-54 protection, suitably grouted to PCC with angle iron base frame 50x50x6mm complete with internal wiring, epoxy powder coated and connection of cable ends with suitable size of cable lugs including providing with the following accessories :- NOTE :- Panel drawings to be got approved from the GE before the order is placed. (a) Aluminium bus bar chamber capacity 400 Amps 3 Phase 4 wire duly insulated with PVC sleeves (As per colour code) incl complete control wiring with suitable size PVC copper conductor cable. Contd.. 82
Supply and fix outdoor distribution panel box, CPRI type tested, fabricated from ISO certified factory of overall size 750 mm (L) x 400 mm (B) x 1500 mm (H) made with 3 mm thick CRCA steel sheet with hinged door front & rear for each cabinet, total 3 cabinets, powder coated by post office red and bottom black after anti-rust treatment of CRCA sheet, top cabinet with incoming 3 ph & N, aluminium busbar of size 40x10mm chamber, middle cabinet for mounting, including MCCB 3 pole 125 Amps - 1 No and for 3 ph & N distribution aluminium busbar of of size 30x6mm and side cabinet for incoming cable tray, 2 Nos earth terminal, door lock for front and rear door with additional external locking arrangements, door handle for each front & rear door, mounting stand made with ISA 40x6mm and 500mm long leg, duly painted with one coat of black bituminous paint , LT danger notice board at front and rear. One MCCB of 25 KA, 125 Amps, 3 pole between incoming and outgoing busbar as mentioned above and 2 sets of aluminium busbar as mentioned above complete all as specified and as directed. Contd.....84
Contd....83 NOTE :- (i) The FPB shall be errected after dismantling / taking out old unserviceable one. (ii) Disconnection of all cables from old FPB and reconnection of all cables to new FPB shall be done and rate shall be deemed to be included in the quoted rate. (iii) Panel shall be CPRI type tested and to be fabricated in ISO certified panel manufacturing factory. MAKE :- Success Engineers, Bhosari or equivalent as specifeid in PS
JP ENTERPRISES
Rama Electricals
ONKAR ELECTRIC AND GENERAL STORE
metro electrical services
Mahindra Electric Stores
M/S. Niksun Electro-Infra Private Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .