Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 CrAccepted-AOC | ₹1.7 Cr | 1 | Accepted-AOC 1st lowest |
| 2 | 2₹1.8 Cr+₹2.5 L (1.45%)Rejected-AOC HOSPITAL ROAD SOLAN TEHSIL SOLAN DISTRICT SOLAN HP | SOLAN | SOLAN | HIMACHAL PRADESH | ₹1.8 Cr+₹2.5 L (1.45%) | 2 | Rejected-AOC 2nd Lowest |
| 3 | 3₹1.8 Cr+₹11.3 L (6.53%)Rejected-AOC | ₹1.8 Cr+₹11.3 L (6.53%) | 3 | Rejected-AOC 3rd Lowest |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
13 Mar 2023, 11:00 amClosed
EE Matiana
JSV Div. Matiana
SH S E of Pumping Machinery for 1st and 2nd stage , P L of Rising main in 1st stage 125mm dia and 2nd stage 100mm dia , C O Anchor block for rising main stage 1st.
2023_HPIPH_69518_1
JSV-DM/13546/4
Open Tender
Civil Works - Water Works
Item Rate
365 days
Kingal Khad
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
Yes
EE Matiana
₹2.1 L
Yes
14 Jul 2023
23 Feb 2023
13 Mar 2023
23 Feb 2023
13 Mar 2023
23 Feb 2023
Amount
Providing, laying, testing & commissioning at site in trenches bevelled ended BIS marked GI pipe confirming to relevent codes IS-3183-2007- & specification its equivalent latest with up to date ammendments of following dia wall thickness & per Rmt weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe's ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable with up to date ammendments (leak proof) in three layers at site of work with welding rods of standard make & all allied accessories whatever required for welding at site, tail pieces, tees, bends & other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions. and cutting of pipes wherever required as per site requirement i/c carriage in all leads & lifts and as directed by Engineer-Incharge.The pipe shall have zinc coating inside and outside confirming to IS -4736-1986 or latest with upto date ammendments & shall be engraved with API 5L Grade as mentioned below. The laying shall confirm to BIS 5822-970 or latest with up to date ammendments to the entire satisfaction of Engineer-In-charge (Earth work & cost of MS flanges after 100 meter length shall be measured & paid for seperately). including all leadslift & carriage of metarials at site and as per direction and to the entire satisaction of the Engineer-in -Charge.
Rising Main Stage-1st 125 mm dia with wall thickness 5.2mm RD 0 to 600 with table 34 Grade L-450 or x 65
125 mm dia with wall thickness 4.80mm RD 600 to 2400 with table 28 Grade L-450 or x 65
125 mm dia with wall thickness 4.80 mm RD 2400 to 2700 with table 17 Grade L-450 or x 65
Rising Main 2nd stage 125 mm dia with wall thickness 4.80 mm RD 0 to 1500 with table 28 Grade L-450 or x 65
Laying & jointing in treches GMS Pipes of 125 mm & 100mm dia (Medium & heavy Grade) jointed with butt welding acording to relevent BIS Standereds code IS:816-1969 including all short pieces of approved specification as per site condition including flushing cleaning & hydrolic testing complete to the best setisfaction of the Engineer-in-charge. The laying laying of pipe should be confirm to BIS:code 5822-1970 with in all leads & lift complete in all respect.
Rising Main Stage-1st 125 mm dia heavy grade RD 2700 to 3000
125 mm dia Medium grade RD 3000 to 3160
Rising Main Stage- 2nd 100 mm dia heavy grade RD 1500 to 2100
101 mm dia Medium grade RD 2100 to 2140
P/F of reflux valve (Stage-1st & 2nd) 125 mm dia ASA-900
100 mm dia ASA-900
P/F of C S Sluice valve (Stage-1st & 2nd) 125 mm dia ASA-900
100 mm dia ASA-900
Providing horizontal spindle horizontal/radial split casing/end section (back pull out arragement) single/double/multistages centrifugal pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt /KSB /Becon weir /Kirloskar / BE /Jyoti or any other approved brand make as per BIS-1520-1980 with upto date ammendments, read with IS -9137-1978 or latest edition suitable for lifting Clear water for under mentioned characterstics with bronze impellers/priming funnels casing ring and shaft sleaves of bronze, shaft of steel grade- with cast iron casing coupled directly through a flexible coupling on a common C.I/Cast steel base plate(base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/ Squarrel cage screen protected drip proof induction motor of standard make such as power required by the pump in the opeation range of (+)10% and (-)Kirloksar /Crompton /Bhel/ NGEF /GEC /SIEMEN / JAYOTI /ABB suitable for operation on 415 (+)/-5% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum 25 % of the duty point head. The motor should be as per IS: 325-1978 with upto date ammendments read with IS 900-1972. It should include cost of bearing nuts,bolts and pointing etc. and should meet the following requirements:-
(a) following requirements:- (I) Discharge (Q) 10.65 LPS or 38.34 Cum/ Hour (ii) Total Dynamic Head: 672.24 Meters. iii) LWL in Sump well 1310.00 Mtrs. (b) Shaft level :- 1275.00 Meters. © Level at discharge point :- 1911 Meters. (d) Suction lift :- 0 Meters. (e) Residual head:- 3.00 Meters. (f) Static head:- 636 Meters. (iii) Rising main (a) Length. 3160 Meters. (b) Dia :- 125 mm. (iv) Pumping hours. 8 hours. (b) Motor =2 Nos. Make: ii) Model iii) Motor rating (KW) iv) Speed. V) Insulation ( C) Coupling 2 Nos. (d) Base Plate 2 Nos.
Providing ICTP Main switch with Change over switch with HRC fuses of Kilburn /L&T /Siemens /Crompton Standard /Havells make and having Capacity 30% extra of the Operational rating as per IS:4064-1978 with upto date ammendments immediatelyafter the power meter of HPSEB.Change over Switch.((i) Make:- .(ii) Type (iii) Capacity Amp. 2 Each
Providing MS .sheet,steel fabricated floor mounted closed(Almirahtype) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, with steel sheet of 16 gaugecomprising, capable of mounting the following accessories withall internal connections: Panel/Switch Board(I) Drawing (ii) Layout plan 1 Each
M.C.B./Oil circuit breaker of Kilburn/L&T/MEI/GECmake & of suitable capacity on incoming feeder with or without initialoil filling as the case may be with neutral linked under voltagereleases as per IS: 2516-1985 with upto date ammendments with. MCB/OCB: i) Make: - ii)Type. iii)Range .(Iv) Capacity Amp. 1 Each
Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/ GEC) as per 2516-1977 with upto date ammendment and of suitable range which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring conditionof the circuit breaker for over current protection. The circuit shouldbe equipped with magnet thermal release with metallic tape etc. Itshould also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. ELCB/ELR:- I)Make :- (CEI approved). ii)Type: iii) Range. 1 Each
The voltage monitor relay three phase with all protection and usual indicator and electric siren against single phasing low voltage,high voltage reverse phasing,over loading and phase voltage difference as per IS:3842(latest edition). VOLTAGE MONITOR RELAY: i)Make:- ii) Type:- iii) Range.380-440 v 1 Each
Power factor meter of standard make as per relevant IS code with upto date ammendments of suitable rating. POWER FACTOR METER: I)Type:- ii) Make:- 1 Each
Frequency meter of standard make as per relevant IS code with upto date ammendments of suitable rating. FREQUENCY METER: I) Type:- ii)Make:- iii) Range: 1 Each
Bus bar chamber having three bars of suitablerating for full length equal to the width of the board for three livephases and suitable for induced current,one copper bar of half therating of full length for neutral phase as per IS:8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments. BUS BAR CHAMBER:- i)Type: - . ii)Make:- iii)Rating 1 Set
ICTP switches with HRC fuses of L&T/Crompton/Kilburn/Siemens/standard/Havells make and of suitable capacity as per IS 4064-1978 with upto dateammendments. ICTP SWITCHES: I) Type : ii)Make:- iii)Capacity Amp. 2 Set
Three phase Indicator lamps complete with toggle switches for individual motors as per IS 3452(P-I&II) with upto date ammendments. THREE PHASE INDICATOR:- i) Type:- ii) Make:- iii) Capacity. 1 Set
Capacitor of Mechneil/Bhel/GEC/ L&T/ make as per IS:2834-1986with upto date ammendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of requiredKVA rating according to HP offered including cablesas per relevant ISI code(of Siemens/Glocter/IEC make) from bus barchamber to capacitor and also including ICTP switches of appropriaterange as per IS: 4064-1978 with upto date ammendments. CAPACITOR:- I)Type:- ii)Make:- iii)Range. KVAR. 2 Each
Providing suitable Oil immersed star delta/direct on line /auto -tran former/starter rotor starter of MEI/Kilburn/Jyoti/L&T/Siemens make as per IS 8544-1979 with upto date ammendments for squirrel cage/slip ring motor mounted on pannel board with magnetic type overload releaseand dashpot, time lag,under voltage release with or without initialoil filling as the case may be with single phase preventor as perIS 1248(P-V)- 1983 with upto date ammendments. STARTER:- I)Type:- ii)Make:- Single Phase Preventor:- i) Type: ii) Make. 2 Each
Providing Hour run meter of recommended make of suitable capacity as per IS:722(Latest edition). HOUR RUN METER:- I) Type:- ii)Make:- iii)Capacity:- Hrs. 2 Each
Providing double flanged cast Iron sluice valve of Leader/Bhel/ Kirloskar/Kilburn/GLED/Fouress/ make and size ond dia above than pump of the delivery line of pump and capable of with standing the normal seat pressure and as per IS-780-1984 with upto date ammendments. SLUICE VALVE: i)Make:- ii) Class:- PN 1.0 iii)Seat Pressure. 10.20 Kg/cm2 iv) Material :- C I 2 Each
Providing double flanged cast Steel sluice valve of Leader/Bhel/ Kirloskar/Kilburn/GLED/Fouress/ make and size ond dia above than pump of the delivery line of pump and capable of with standing the normal seat pressure and as per IS-1414/ API-600 (Class ASA-300 ) with upto date ammendments (Total head i/c water hammer effect = 672.24 Mtrs.) SLUICE VALVE: i)Make:- ii) Class:- ASA 600 iii)Seat Pressure. 52.00 Kg/cm2 iv)Material :- CS 2 Each
Providing double flanged (Swing type) Cast steel Reflux valve of Leader /Bhel /Kirloskar / Kilburn /GLED/ Fouress /Kartar make and of one dia above than pump having bye pass arrangement for delivery line of pump and capable of with standing normal seat pressure as per BS:1868 (P.I) with upto date ammendments. (Total head i/c water hammer effect = 672.24Mtrs.) REFLUX VALVE:- i)Make: Class: ASA600 , Seat Pressure: 52.00 KG/Cm2, Material:- C. S. 2 Each
Providing double flanged (Swing type) Cast steel Non Return valve of Leader /Bhel /Kirloskar / Kilburn /GLED/ Fouress /Kartar make and of one dia above than pump having bye pass arrangement for delivery line of pump and capable of with standing normal seat pressure as per BS:1868 (P.I) with upto date ammendments. (Total head i/c water hammer effect = 506.77 Mtrs.) REFLUX VALVE:- i)Make: Class: ASA600 , Seat Pressure: 52.00 KG/Cm2, Material:- C. S. 1 Each
Providing 100mm dia circular dia pressure gauge of Fiebing/Bourden Prega/precision make complete with all accessories such as stop cock,copper tubing etc. as per IS 3624-1987 with upto date ammendments. PRESSURE GAUGE:- I)Make ii) Range- 0-52 Km/cm2. 2 Each
Installation of all the items appearing at Serial No. 7 to 17 as per the systematic drawing attached with the tender documents(Drg. No.1). 1 Job
Providing and fixing double flanged MS/GMS piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends,tees reducers/increasers with companion flanges matching with the relevant specifications of the accessores as indicated in the drawing No 2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS 1364-1983. The pipes shall be as per relevant IS code and to withstand 1.5 times total head stipulated under item No.1. The size of the various components to be as under:- (I) Suction pipe… 65 mm dia. GI/MS (ii)Delivery pipe…50 mm dia G.I.Heravy MSERW Pipe (iii)Common Header :-65 mm dia. G.I.Heavy MSERW pipe and will extended upto 5 mtrs from the outer wall of the pump house in the direction to be jointed.
SUCTION PIPE:- I)Make:- . ii)Grade. iii) Thickness. iv) Pressure rating. DELIVERY PIPE AND COMMON HEADER:- i)Material ii) Grade. iii) Thickness. iv)Pressure rating. 1 Job
Providing and laying copper PVC insulated armoured power cable(one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS:1554(P-I)1988 or latest with upto date ammendments of Siemens//Gloster/ JEC/ICC/EICO National/Grandlay make including all other accessores such as thimbles, flexible,pipes solder,nuts and bolts,cable glands etc. laid in pipes or trenches under floor. ARMOURED POWER CABLE:- A) Motor side (from switch to starter and starter to motor).i)Size: ii)Make:- iii)Type:- iv)Capacity. v) Core. B) Supply Side: (From meter of HPSEB to Bus Bar and Switch) :-i)Size: ii)Make:- iii)Type:- iv)Capacity. v) Core. 1 Job
Providing and fixing double loop earthing and G.I. plate 600mmx 600mmx 3mm thick electrode complete with material such as thimbles, nuts and bolts,charcoal and common salt,25mmx3mm G.I. strips/as per IS: 3043-1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc.complete in all respect. 1 Job
2nd Stage.
Providing horizontal spindle horizontal/radial split casing/end section (back pull out arragement) single/double/multistages centrifugal pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/KSB//Becon weir/Kirloskar/ BE/Jyoti or any other approved brand make as per BIS-1520-1980 with upto date ammendments, read with IS -9137-1978 or latest edition suitable for lifting Clear water for under mentioned characterstics with bronze impellers/priming funnels casing ring and shaft sleaves of bronze, shaft of steel grade- with cast iron casing coupled directly through a flexible coupling on a common C.I/Cast steel base plate(base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/ Squarrel cage screen protected drip proof induction motor of standard make such as power required by the pump in the opeation range of (+)10% and(-15%)Kirloksar/Crompton/Bhel/NGEF/GEC/SIEMEN/ JAYOTI/ABB or any other approved make suitable for operation on 415(+)/-5% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum 25 % of the duty point head. The motor should be as per IS: 325-1978 with upto date ammendments read with IS 900-1972. It should include cost of bearing nuts,bolts and pointing etc. and should meet the following requirements:-
(a) following requirements:- (I) Discharge (Q) 5.90 LPS or 21.24 Cum/ Hour (ii) Total Dynamic Head: 436.46 Meters. iii) LWL in Sump well 1911.50 Mtrs. (b) Shaft level :- 1911.00 Meters. © Level at discharge point :- 2318.00 Meters. (d) Suction lift :- 0 Meters. (e) Residual head:- 3.00 Meters. (f) Static head:- 407 Meters. (iii) Rising main (a) Length. 2240 Meters. (b) Dia :- 100 mm. (iv) Pumping hours. 8 hours. (b) Motor =2 Nos. Make: ii) Model iii) Motor rating (KW) iv) Speed. V) Insulation ( C) Coupling 2 Nos. (d) Base Plate 2 Nos.
Providing ICTP main switch With Change over switch with HRC fuses of Kilburn/L&T/Siemens/Crompton Standard/Havells make and having Capacity 30% extra of the Operational rating as per IS:4064-1978 with upto date ammendments immediatelyafter the power meter of HPSEB. Change over Switch.((i) Make:- .(ii) Type (iii) Capacity Amp. 1 Each
Providing MS .sheet,steel fabricated floor mounted closed(Almirahtype) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories withall internal connections: Panel/Switch Board(I) Drawing (ii) Layout plan 1 Each
M.C.B./Oil circuit breaker of Kilburn/L&T/MEI/GECmake & of suitable capacity on incoming feeder with or without initialoil filling as the case may be with neutral linked under voltagereleases as per IS: 2516-1985 with upto date ammendments with. MCB/OCB: i) Make: - ii)Type. iii)Range .(Iv) Capacity Amp. 1 Each
Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/ GEC) as per 2516-1977 with upto date ammendment and of suitable range which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring conditionof the circuit breaker for over current protection. The circuit shouldbe equipped with magnet thermal release with metallic tape etc. Itshould also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. ELCB/ELR:- I)Make :- (CEI approved). ii)Type: iii) Range. 1 Each
The voltage monitor relay three phase with all protection and usual indicator and electric siren against single phasing low voltage,high voltage reverse phasing,over loading and phase voltage difference as per IS:3842(latest edition). VOLTAGE MONITOR RELAY: i)Make:- ii) Type:- iii) Range. 1 Each
Power factor meter of standard make as per relevant IS code with upto date ammendments of suitable rating. POWER FACTOR METER: I)Type:- ii) Make:- 1 Each
Frequency meter of standard make as per relevant IS code with upto date ammendments of suitable rating. FREQUENCY METER: I) Type:- ii)Make:- iii) Range: 1 Each
Bus bar chamber having three bars of suitablerating for full length equal to the width of the board for three livephases and suitable for induced current,one copper bar of half therating of full length for neutral phase as per IS:8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments. BUS BAR CHAMBER:- i)Type: - . ii)Make:- iii)Rating 1 Set
ICTP switches with HRC fuses of L&T/Crompton/Kilburn/Siemens/standard/Havells make and of suitable capacity as per IS 4064-1978 with upto dateammendments. ICTP SWITCHES: I) Type : ii)Make:- iii)Capacity Amp. 2 Set
Three phase Indicator lamps complete with toggle switches for individual motors as per IS 3452(P-I&II) with upto date ammendments. THREE PHASE INDICATOR:- i) Type:- ii) Make:- iii) Capacity. 1 Set
Capacitor of Mechneil/Bhel/GEC/ L&T/ make as per IS:2834-1986with upto date ammendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of requiredKVA rating according to HP offered including cablesas per relevant ISI code(of Siemens/Glocter/IEC make) from bus barchamber to capacitor and also including ICTP switches of appropriaterange as per IS: 4064-1978 with upto date ammendments. CAPACITOR:- I)Type:- ii)Make:- iii)Range. KVAR. 2 Each
Providing suitable Oil immersed star delta/direct on line /auto -tran former/starter rotor starter of MEI/Kilburn/Jyoti/L&T/Siemens make as per IS 8544-1979 with upto date ammendments for squirrel cage/slip ring motor mounted on pannel board with magnetic type overload releaseand dashpot, time lag,under voltage release with or without initialoil filling as the case may be with single phase preventor as perIS 1248 (P-V)- 1983 with upto date ammendments. STARTER:- I)Type:- ii)Make:- Single Phase Preventor:- i) Type: ii) Make. 2 Each
Providing Hour run meter of recommended make of suitable capacity as per IS:722(Latest edition). HOUR RUN METER:- I) Type:- ii)Make:- iii)Capacity:- Hrs. 1 Each
Providing double flanged cast Iron sluice valve of Leader/Bhel/ Kirloskar/Kilburn/GLED/Fouress/ make and size ond dia above than pump of the delivery line of pump and capable of with standing the normal seat pressure and as per IS-780-1984 with upto date ammendments. SLUICE VALVE: i)Make:- ii) Class:- PN 1.0, iii)Seat Pressure. 10.20 Kg/cm2, iv) Material:- C I 2 Each
Providing double flanged cast Steel sluice valve of Leader/Bhel/ Kirloskar/Kilburn/GLED/Fouress/ make and size ond dia above than pump of the delivery line of pump and capable of with standing the normal seat pressure and as per IS-1414/ API-600 (Class ASA-300 ) with upto date ammendments (Total head i/c water hammer effect = 436.46 Mtrs.) SLUICE VALVE: i)Make:- ii) Class:- ASA300 iii)Seat Pressure. 52.00 Kg/cm2 iv)Material :- CS 2 Each
Providing double flanged (Swing type) Cast steel Reflux valve of Leader /Bhel /Kirloskar / Kilburn /GLED/ Fouress /Kartar make and of one dia above than pump having bye pass arrangement for delivery line of pump and capable of with standing normal seat pressure as per BS:1868 (P.I) with upto date ammendments. (Total head i/c water hammer effect =436.46 Mtrs.) REFLUX VALVE:- i)Make: Class: ASA300 , Seat Pressure: 52.00 KG/Cm2, Material:- C. S. 2 Each
Providing double flanged (Swing type) Cast steel Non Return valve of Leader /Bhel /Kirloskar / Kilburn /GLED/ Fouress /Kartar make and of one dia above than pump having bye pass arrangement for delivery line of pump and capable of with standing normal seat pressure as per BS:1868 (P.I) with upto date ammendments. (Total head i/c water hammer effect = 436.46 Mtrs.) REFLUX VALVE:- i)Make: Class: ASA300 , Seat Pressure: 52.00 KG/Cm2, Material:- C. S. 1 Each
Providing 100mm dia circular dia pressure gauge of Fiebing/Bourden Prega/precision make complete with all accessories such as stop cock,copper tubing etc. as per IS 3624-1987 with upto date ammendments. PRESSURE GAUGE:- I)Make ii) Range- 0-52 Km/cm2. 2 Each
Installation of all the items appearing at Serial No. 7 to 17 as per the systematic drawing attached with the tender documents (Drg. No.1). Job. 1
Providing and fixing double flanged MS/GMS piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends,tees reducers/increasers with companion flanges matching with the relevant specifications of the accessores as indicated in the drawing No 2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS 1364-1983. The pipes shall be as per relevant IS code and to withstand 1.5 times total head stipulated under item No.1. The size of the various components to be as under:- (I) Suction pipe… 65 mm dia. GI/MS (ii)Delivery pipe…50 mm dia G.I.Heravy MSERW Pipe (iii)Common Header :-65 mm dia. G.I.Heavy MSERW pipe and will extended upto 5 mtrs from the outer wall of the pump house in the direction to be jointed. Job. 1
SUCTION PIPE:- I)Make:- . ii)Grade. iii) Thickness. iv) Pressure rating. DELIVERY PIPE AND COMMON HEADER:- i)Material ii) Grade. iii) Thickness. iv)Pressure rating. Job. 1
Providing and laying copper PVC insulated armoured power cable(one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS:1554(P-I)1988 or latest with upto date ammendments of Siemens//Gloster/ JEC/ICC/EICO National/Grandlay make including all other accessores such as thimbles, flexible,pipes solder,nuts and bolts,cable glands etc. laid in pipes or trenches under floor. ARMOURED POWER CABLE:- A) Motor side (from switch to starter and starter to motor).i)Size: ii)Make:- iii)Type:- iv)Capacity. v) Core. B) Supply Side: (From meter of HPSEB to Bus Bar and Switch) :-i)Size: ii)Make:- iii)Type:- iv)Capacity. v) Core. Job. 1
Providing and fixing double loop earthing and G.I. plate 600mmx 600mmx 3mm thick electrode complete with material such as thimbles, nuts and bolts,charcoal and common salt,25mmx3mm G.I. strips/as per IS: 3043-1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc.complete in all respect. Job. 1
Excavation in drain channel for pipes and pits upto all depths including shoring ,struting and timbering in all kinds of soil such as spade work, pick work, jumper work, blasting work,kankar, mooram singles including decomposed in soft /hard work ,wedging out of hard and soft rocks where blasting is prohibited, in saturated soil including bailing out the watering, by cutting in slopes where ever required, in rocky portion suitable anchorage shall be provided (anchorage will be paid separately) and stacking the excavated materials not more than 3.00 meters clear from the edge of excavation and then returning the stacked soils in 15 cm (fifteen centi meter) layer when required into sides of trenches and above the laid pipes etc. consolidating in each deposited layer by ramming and watering and then disposing of all surplus excavated soil in all leads and lifts . After disposal ,the surface shall be neatly dressed and leveled and shoring to its original shape complete in all respect as per direction and entire satisfaction of Engineer in charge in Pick Jumper work:
Prov. and laying cement concrete 1:4:8 (1cement:4sand:8graded stone agg. 40mm nominal size) and curing complete excluding cost of form work i/c all leads and lifts :-a) Foundation and plinth.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering, strutting , strutting and propping etc. with wooden, battens, and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs.and removal of the same for insitu reinforced concrete and plain concrete work including all leads and lifts in:-
Vertical surfaces such as soffits of suspended floors,roofs,landings and the like including attached pillasters,buttresses, plinth and string courses and the like.
Prov. Mild steel/Tor steel reinforced for RCC work including bending, binding and placing in position complete upto floor two level i/c all leads and lifts complete in all respect. :- a) Tor steel.
Providing and laying cement concrete work 1:2:4(1cement:2sand:4 graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in :-
Columns,pillars,posts & struts upto floor two level up to floor two level.
Surjeet Singh Thakur
puneet angra
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .