| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹26.9 L+₹2.8 L (11.8%)Rejected-Finance | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹28.8 L+₹4.7 L (19.5%)Rejected-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder | |
| 4 | L4₹29.5 L+₹5.4 L (22.4%)Rejected-Finance CHANDPURA TIKAMGARH DIST TIKAMGARH MP | TIKAMGARH | TIKAMGARH | MADHYA PRADESH | L4 | Rejected-Finance Rejected being 4th Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
4 Nov 2020, 6:00 pmClosed
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR-73 OF 2019-20 SPECIAL REPAIRS TO BUILDING NO. P-65 (OR MARRIED ACCOMMODATION) ALONGWITH CONNECTED ITEMS AT MILITARY STATION ABOHAR (2ND CALL)
2020_MES_325791_2
CA NO. CWE SGNR - 73 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
ABOHAR
Class D
Category a(i)
10 documents required · 10 mandatory
₹500
GE ABOHAR
₹62,000
Yes
26 Nov 2020
17 Sept 2020
6 Nov 2020
17 Sept 2020
4 Nov 2020
20 Oct 2020
Amount
Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) in roof , floors (other than ground floor ), beams, staircase, landing,chajjas and similar suspepnded work complete all as specified and directed by Engineer-in-Charge
Demolition of mud in roofs any thickness incl plastering and leeping complete all as specified and directed by Engineer-in-Charge
Dismantling of brick tiles or terracing tiles in roofs single layer complete all as specified and directed by Engineer-in-Charge
M & L for 50mm thick cement concrete type C2 1:3:6 (40mm graded aggregate) as in plinth protection, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-0 as required (superficial area n. exc 150 sq cm) complete all as specified and directed by Engineer-in-Charge
M&L for steel bars for TMT Fe-500D 10mm dia and over, cut to length bent to shape required, incuding cranking, bending spirally for hooping for columns, hooping ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or sceruing with clips complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 7 here-in-before but for 5 mm dia and over up to and including 8 mm dia as in stirrups complete all as specified and directed by Engineer-in-Charge
M&L for Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in as in foundations, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete complete all as specified and directed by Engineer-in-Charge
M&L for Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in Columns, pillars, piers, posts & struts etc. complete all as specified and directed by Engineer-in-Charge Note : Form work & reinforcement measured separately
M&L for Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5 metre span complete all as specified and directed by Engineer-in-Charge Note : Form work & reinforcement measured separately
M&L for Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate in slab supported on walls,beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge Note : Form work & reinforcement measured separately
M&L for Form work to sides of concrete foundation, footings bases of columns and plinth beams and similar works rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge
M&L for Formwork to soffits of suspended slabs, such as roof slabs, floor slabs landing and similar work not exceeding 200mm thick (Horizontal & sloping) fair finished surfaces complete all as specified and directed by Engineer-in-Charge
M&L for From work to edges of concrete flates treads breaks in floors, window cill concrete railing, opening in convert valley floor and roof exc 10 cm but n.exc 20 cm wide and sides RCC/PCC band in walls complete all as specified and directed by Engineer-in-Charge
M&L for Formwork to sides of pillars, posts, struts, piers columns & stanchions : rough finished surface of flat concrete complete all as specified and directed by Engineer-in-Charge
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engineer-in-Charge
S & F in repair galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge
Dismantling of brick work built in cement mortar complete all as specified and directed by Engineer-in-Charge
M&L for Brick work using fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge
All as per Srl item No. 20 here-in-before but for except bricks complete all as specified and directed by Engineer-in-Charge
M & L for brick work in half brick thick wall using fly ash bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge
Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the permices complete all as specified and directed by Engineer-in-Charge
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge
M & L for glazed ceramic coloured tiles of size 450mm x 350mm x 7mm thick in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over 10mm thick cement sand (1:4) as in backing coat complete all as specified and directed by Engineer-in-Charge
M & L for non skid ceramic coloured joint free tiles with matt finish, 7 to 8 mm thick ( square/ rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:6) complete all as specified and directed by Engineer-in-Charge
All as per Srl item No. 26 here-in-before but for as in skirting over 10 mm cement mortar backing ( 1:4) complete all as specified and directed by Engineer-in-Charge
M & L for Machine cut kota stone slab flooring 18 - 20 mm thick over cement screed base laid over and including 15mm thick screed bed in cement mortar 1:6 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge
M & L for Machine cut kota stone slab 18 - 20 mm thick in riser of steps, skirting, dado and pillar over cement screed base laid over and including 10mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge
M&L for Granite 18 - 20mm thick(of any type) works (table rubbed and polished) in step, window cills, cooking platforms and the like in cement mortar (1:4), 20 mm thick including pointing in white cement (1:2) using marble dust with admixture of pigments to match complete all as specified and directed by Engineer-in-Charge
Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each complete all as specified and directed by Engineer-in-Charge
S&F for "fiberways" brand fiber glass reinforced plastic (FRP) Door frame of three legged of cross section 90x45 mm size single nrebate of 32mmx15mm to receive shutter of 30mm thickness. The laminate door frame moulded with two resistant grade unsatratedpolyster plain and chapped mat d or frame laminate shall be 2mm thick and shall be filled with subbish wooden block in all two three legs . the frame shall be covered with fibre glass from all side. MS stay shall be provided at the bottem to steady the frame complete all as specified and directed by Engineer-in-Charge
S&F for "fiberways" brand 30mm thick glass fiber reinforced plastic (FRP) panelled door shutter of required colour are approver brand and manufacture made with fire resistance grade unsatratedpolyster plain moulded to 3mm thick fiber laminate for foming hollow ralliuded styles with wooden frame and suitable blocks of sessoned wood inside at required place for fixing of fiber-cast monolithitically with 5mm thick FRB laminated for panels and conforming to IS-4858-2000 complete all as specified and directed by Engineer-in-Charge
S & F for PVC butt hinges, medium weight 100 mm size fixed with steel screw complete all as specified and directed by Engineer-in-Charge
S & F for tower bolt 150 mm of PTMT all as specified complete all as specified and directed by Engineer-in-Charge
S & F for door handle D type 150 mm of PTMT complete all as specified and directed by Engineer-in-Charge
Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed by Engineer-in-Charge
Taking down shutters refixing in same opening but area exceeding 1.00 Sqm and not exceeding 2.0 Sqm complete all as specified and directed by Engineer-in-Charge
Taking down shutters but area exceeding 1.00 Sqm and not exceeding 2.0 Sqm complete all as specified and directed by Engineer-in-Charge
S & F for Factory made 35mm thick IInd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats complete all as specified and directed by Engineer-in-Charge
S & F for Factory made Plain framed, panelled shutter IInd class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge
S & F for pressed steel door frames of size 105mm x 60mm with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified and directed by Engineer-in-Charge
S & F for pressed steel door frames size of 125X60mm with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified and directed by Engineer-in-Charge
M&L for plain Cement concrete 1:3:6 type C-1 for filling of pressed steel fram and hold fast blocks etc complete all as specified and directed by Engineer-in-Charge
S&F gqalvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm complete all as specified and directed by Engineer-in-Charge.
S & F for aluminium tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm long complete all as specified and directed by Engineer-in-Charge
S & F for aluminium handle cast type anodized, 150 mm long complete all as specified and directed by Engineer-in-Charge
S & F for 250mm long mild steel sliding door, bolts, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including minimum of 6 bolts and nuts four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engineer-in-Charge
S & F for mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified and directed by Engineer-in-Charge
S & F for small fittings such as door stops and like, including all necessary labours articles not exceeding 200 Cucm each of 2nd class hard wood complete all as specified and directed by Engineer-in-Charge
S&F for hasp & staple safety type aluminium anodised with hinges pins incl bolt to hinge plate fixed with screw 125mm complete all as specified and directed by Engineer-in-Charge
S&F for peg set of stainless steel solid body of 125mm to 175 mm having 6 Nos hooks fixed with brass chromium plated screws complete all as specified and directed by Engineer-in-Charge
S& F in repairs Drapory curtain rod of 25 mm dia decorative type with brass coated ends caps including fixing arragements like brackets,stops,rollers etc. complete all as specified and directed by Engineer-in-Charge
S&F Factory made box type steel window/Ventilators with hung shutter both glazed and gauged ,shutter frame 60x25mm ERW hollow 'P' section with wall thickness not less than 1mm fixed to pressed steel frame 120mmx 70mmx1.6mm thick including fixing glazed portion,iron grills 8mm suare MS bar hunges with steel handle and fitting, lugs etc, including one coat of primer complete all as shown in drg No BTD 889 sheet 1/4 to 4/4 complete all as specified and directed by Engineer-in-Charge (Note :- Wire mesh and glass shall be measured and paid separately under relevent items of BoQ)
S & F for 4 mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge
S & F for figured glass 4 mm thick pin head type and glazing with oil putty and securing with glazing pins not exceeding 0.50 Sqm in each pan complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new steel surface over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed by Engineer-in-Charge
S & F for framed work such as grills, cooler stand ,grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming to Fe-290(Grade E-165) complete all as specified and directed by Engineer-in-Charge
S & F for structural steel work rolled mild steel joist, channel,angle,or Tee sections, fixed independently conforming to Fe 410-W (Grade-250) Quality 'B' complete all as specified and directed by Engineer-in-Charge
S & F for exc 12 mm dia & n. exc 20 mm dia of neck mild steel bolts purpose made with hexagonal or square head one and end and screwed to other, or screwed to both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 30 cm long complete all as specified and directed by Engineer-in-Charge
M&L for plates (plain or chequered) channels , square cut or notched (ordinary and counter sunk) forming holes , without any attachment Fe-410-W (Gde-E-250) quality -B complete all as specified and directed by Engineer-in-Charge
S&F stainless steel sink with draining board made out of 1.00mm thick kitchen or laboratory with plugs, washers, waste pipe, cast iron cantilever brackets and connecting union to waste pipe; overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm including taking down existing chinaware sink complete all as specified and directed by Engineer-in-Charge. Make : Prayag Model No 1128, Blue Star Model No BSSBSD-49, Jayana Model No SBSD-05
M & L for 19mm thick prelaminated particle board exterior grade,prelaminated both side with decorative choice laminations, fixed with screws to timber frame work with 6mm thick teak wood lipping fixed with nails as in cup board shutters, shelves including dismantling boarding any deiscription fixed with rails complete all as specified and directed by Engineer-in-Charge.
S & F for tower bolt 100 mm of PTMT complete all as specified and directed by Engineer-in-Charge
S & F for door handle D type 100 mm of PTMT complete all as specified and directed by Engineer-in-Charge
S & F for Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed by Engineer-in-Charge
S&F for Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed by Engineer-in-Charge
Dismantling boarding, any description fixed in any position with nails complete all as specified and directed by Engineer-in-Charge.
M&L for Water proofing treatment to RCC sunken slab (not exceeding 45cm depth of sunken) as specified below and as directed by Engineer-in-Charge. :- (a) Cleaning the surface with wire brush/coir brush, removing loose material like dust particles, dirt etc. (b) applying 15 mm plaster in CM 1:3 with WPC on raised verticle surface (c) Creating fillet coving of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on the horizontal and verticle surface (e) Provision of glass fiber mesh of 2 x 2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) Cement concrete 1:4:8 over the coating as per requirment (h) Joining the sanitary pipes with the water proofing tape having bridging ability of more than 1.5 mm (j) Filling the gap between the wall opening and saintary pipe with non shrink cementatious grout as specified by Manufacturer and complete all as specified and directed by Engineer-in-Charge. Make:- Dr. Fixit / Fosroc / STP Note: (i) The treatment shall be carried out by approved authorised applicator approved by CWE as per the manufacturers instructions and as directed by the Engineer in charge. (ii) The Plan area of floor (sunken) shall be considered for payment . (iii) PCC filling in sunken portion will be measured seperately. (vi) WPC shall be measured and paid separately.
M&L for Providing 100mm plain cement concrete 1:5:10 (Type 'E-2', 40 mm graded stone aggregate as in foundation, filling and mass concrete) complete all as specified and directed by Engineer-in-Charge.
S&F Stainless steel plate rack of size 750mm x 600mm, made out of 1mm thick stainless steel of sheet of 1st quality complete all as specified and directed by Engineer-in-Charge Make:Anupam international model No KPR-311 or Equivalent make and model approved by GE.
S & F repair vitreous china squatting pan Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishing complete all as specified and directed by Engineer-in-Charge
S & F in repairs PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection to WC pan complete all as specified and directed by Engineer-in-Charge
S & F in repairs vitrous china wash hand basin coloured top bowl type of size 380x380mm long screwed shank fly nut flange end including cutting for and pinning in granite slab of hole including 32 mm dia chromium plated waste coupling and bottle trap complete all as specified and directed by Engineer-in-Charge MAKE- Hindware Cat No 91807 range Hi Lites or equivalent in Parryware
S&F in repair 15mm bore bib taps,chromium plated, fancy type, cast copper alloy with crutch or butterfly handle , screwed down, secrewed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge
S & F in repairs 15mm bore stop cock one way fancy type, chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed complete all as specified and directed by Engineer-in-Charge
S&F in repair brass chromium plated central hole basin mixer with regular spout,popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by Engineer-in-Charge Make : ESS ESS Cat Part No.- C-211A
S&F for Sink mixer with swinging spout(wall mounted model)Chromium plated brass with connection and nut complete all as specified and directed by Engineer-in-Charge Make- ESSESS Cat Part No DE-12 or equivalent to Parryware / Nirali / Prayag
S&F for brass chromium plated wall mixer for mixing hot& cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge Make:- ESS ESS Cat Part No.- C-216D
S & F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer-in-Charge
S&F for PVC bathroom cabinet mirror 450 x 350 mm complete all as specified and directed by Engineer-in-Charge Make:-Prayag Cat Part No551 / Polytuf / Shakti / Pearl as approved by GE.
S&F for Swivel shower of any colour with Shower arm 15 mm size, 195mm long with bend of 45 degree with flange of any colour for fixing with 15mm pipe. (Minimum weight 40gms) complete all as specified and directed by Engineer-in-Charge
S&F for Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden / plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engineer-in-Charge
S & F for soap dish fixed as chromium plated brass complete all as specified and directed by Engineer-in-Charge
S&F in repair Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge
S&F for PVC corner shelf with bracket complete all as specified and directed by Engineer-in-Charge
Taking down steel tubing 15mm bore and connections complete all as specified and directed by Engineer-in-Charge
Refixing of GI Tubing 15mm bore to walls and ceiling or in floors etc (GI tubes obtained from taking down of respective item) including provision of new fittings as required complete all as specified and directed by Engineer-in-Charge
S & F 15mm bore medium grade GI Tubing with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge
Taking down steel tubing 20mm bore and connections complete all as specified and directed by Engineer-in-Charge
Refixing of GI Tubing 20mm bore to walls and ceiling or in floors etc (GI tubes obtained from taking down of respective item) including provision of new fittings as required complete all as specified and directed by Engineer-in-Charge
S & F 20mm bore medium grade GI Tubing with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge
S&F in repairs, for rotational moulded polythene three layred white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 500 Ltrs including dismantling of water tank complete all as specified and directed by Engineer-in-Charge.
M&L for Ball valves PTMT 20mm, with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe of following description (Min. wt 20 mm -210 gms) complete all as specified and directed by Engineer-in-Charge
S & F in repairs 15mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
S & F in repairs 20mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
Taking down CI / AC / PVC soil waste and vent pipe any radius including all fittings complete all as specified and directed by Engineer-in-Charge
S & F in repairs PVC (SWR) pipe single socketed with rubber ring joints 110mm dia fixed to wall complete all as specified and directed by Engineer-in-Charge
S & F in repairs PVC (SWR) pipe single socketed with rubber ring joints 75mm dia fixed to wall complete all as specified and directed by Engineer-in-Charge
S&F in repairs cast iron waste and vent pipe in any length with or without ear with cement joints laid in trenches or in floor 100mm dia complete all as specified and directed by Engineer-in-Charge
S&F in repairs cast iron waste and vent pipe in any length with or without ear with cement joints laid in trenches or in floor 75mm dia complete all as specified and directed by Engineer-in-Charge
S&F in repairs 110mm bore PVC (SWR) bends any radious provided with access door complete all as specified and directed by Engineer-in-Charge
S&F in repairs 75mm bore PVC (SWR) bends any radious provided with access door complete all as specified and directed by Engineer-in-Charge
S&F in repairs 75 mm bore PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge
S & F in repairs Grating doom 125 mm dia with waste hole of PTMT (Min wt 40 gm) complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster/dado on brick wall including racking out joints, hacking for keys scrubbing down with water complete all as specified and directed by Engineer-in-Charge
M & L rendering 15mm thick on fair faces or other than fair faces of brick work in CM 1:6 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
M & L rendering 15mm thick on fair faces of brick work in CM 1:4 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
M&L for Rising damp-proof coating system with Single component ready to use damp-proof coating Roff Hydamp complete all as specified and directed by Engineer-in-Charge. : 1. SURFACE PREPARATION: Thoroughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc. All large voids or hollow portions must be removed and re-plastered. Non-moving cracks having width upto 5 mm must be filled with Polymer based crack filler. 2 APPLICATION: Apply the first coat of Roff Hydamp with a paintbrush directly on the prepared surfaces. Allow to dry for a minimum 2-3 hrs. Apply one part of Roff Hydamp and 2 parts of OPC white cement and make the Putty, apply Putty on the entire surface area. Allow it to dry for at least 3-4 hours. Apply the Final coat of Roff Hydamp on the entire surface.
M&L for preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over 3mm thick wall care putty over a coat of clearcolle primer complete all as specified and directed by Engineer-in-Chage.
M&L for complete removal of existing wall surfaces and applying two coats of oil bound distemper over 3mm tick wall care putty over a coat of clearcolle primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of two coats of cement base paint over a coat of alkali resistant primer on newly pastered surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of Old plastered external surfaces of wall by complete removing old treatment and applying two coats of interior grade wall putty( 1mm thick of each coat) manually and making it smooth with sand paper by mechanical method i.e. with hand electric grinder and then applying two coat of weather coat emulsion over one coat of primer including all as specified by mechanical method complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted wood and wood base surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted surfaces of steel and iron work over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new wood and wooden base surface and applying two coats of synthetic enamel paint over a coat of pink primer on wooden surface of any discription not otherwise described over 10cm width of girth complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel and iron surfaces of any discription not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Chage.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.
M&L for Hard core of broken bricks of gauge not exceeding 63mm, deposited,spread and leveled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 75 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base floors complete all as specified and directed by Engineer-in-Charge.
M & L for Machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade over 25 mm thick layer of fine sand complete all as specified and directed by Engineer-in-Charge.
M&L for contineous brick edging with burnt clay brick work with sub class ‘B’ with width equal to width of brick laid dry on end vertically complete all as specified and directed by Engineer-in-Charge.
S&F for Floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge.
Excavation trenches n exc 1.50 wide and n exc 1.50 m depth for foundation etc in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading leveling, watering and well ramming in layers n exc 25 mm thick soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc 250 m and deposited where directed at a level not exc 1.50 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete Type D-2, 1:4:8 (40 mm graded stone aggregate as in foundation, filling and mass concrete) complete all as specified and directed by Engineer-in-Charge.
S&F for cast iron bend ( any radius) dimenshing pieces or tappers ( large bore measured) 100mm bore complete all as specified and directed by Engineer-in-Charge.
S&F for cast iron bend ( any radius) dimenshing pieces or tappers ( large bore measured) 75mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repairs cast iron floor trap 75mm dia incl jointing to waste pipe fixed in cement concrete type B-1 1:2:4) 75mm dia complete all as specified and directed by Engineer-in-Charge.
S & F steel work in rectanguler/square hollow section trusses including special shaped washer etc complete using ERW or incl butt welded tubes confirming to relevant IS Code with one coat of sink chromate primer paint incl preparation of surface complete all as specified and directed by Engineer-in-Charge.
S&F for 50mm thick PUF panel made of Puf insulation in core having density 40+2 Kg/Cum sandwiched betweeen two numbers of polyster coated galvalume steel sheet.these sheets shall be made out of 0.50mm thick (TCT) High tensile steel having min yield strength of 550 Mpa confirm to AZ 150 of AS-1397 wityh hot dip metalic coating of 55% ZN alloy having total coating mass of minimum 150 gms/sqm inclusive of bothside. the material shall be coated with polyster coating paint system of 20 micron over primer of 5 micron (exposed side) & alkyd back coat of 5 micron over primer coat of 5 microns.the material shall be supplied as per drawing (approved by GE),colour and as per instruction complete all as specified and directed by Engineer-in-Charge.
S&F anodized aluminium snap grid frame work for false ceiling size of grid 605mm x 605mm with 6mm dia GI wire hanger (Upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40mm x 3mm size 60mm long complete all as specified and directed by Engineer-in-Charge.
S&F for 8 mm thick exposed metal frame celing with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mmx600mm grid all as per manufacturer's instructions, finish, fixed to aluminium/ CGI frame work with hold down clips in false ceiling complete all as specified and directed by Engineer-in-Charge.
M& L for Pre painted gavalume zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, hip, vally gutter, drips as in wall,fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
M& L for Pre painted gavalume zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverings / cladding to wall,fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Shotcreting 25MM thick in RCC columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characterristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of certering and shuttering at edges and corners etc as directed by Engineer-in-Charge including Chipping of unsound /weak concrete material 25 mm average thickness from slabs,beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@ 6sqm/ltr at DFT of 100microns as per specifications and disposal of debries for all lead and lifts all complete all as specified and directed by Engineer-in-Charge.
S&F for Hard drawn steel wire fabric not exc 4Kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt complete all as specified and directed by Engineer-in-Charge.
M & L for 5mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M& L for plain cement concrete 1:2:4 type B1, using 20 mm graded stone aggregates as in bed blocks ,coping, hold fast blocks etc. complete all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning with dry and clean fine river sand for underground cable 8cm before laying the cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed by Engineer-in-Charge
Supplying and laying well burnt clay bricks old size class 'B' laid dry and flat for protection over the cable with equal to the length of bricks across the route of underground cable, complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing and commissioning of 25 sqmm, 4 core XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-1554 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ.
S & F exhaust fan 300 mm sweep metal body with self closing louver shutter suitable for operation on 230 volts, single phase , AC including cutting of holes on existing wall and makeing the surface and connecting up with 2 core,1.0 sqmm PVC insulated & PVC sheathed copper conductor flexible cable drawn in PVC conduit complete all as specified & directed by Engineer-in-charge.
Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as Switches, sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface complete all as specified and directed by Engineer-in-Charge
M&L for Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core including PVC rigid concealed conduit medium grade of suitable size (not less than 20mm dia) with all accessories such as bend reducers / MS hooks, MS junction boxes 2mm thick galvanized steel pressed sunken terminal boxes of suitable sizes for mounting of switches sockets, fan regulators etc covered with 2.8mm thick plastic laminate (Hylem / Anchor) top cover including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated stranded (Green colour) connected to common earth point dolly for one light point / call bell point / fan point to be controlled by one number one way point switch complete all as specified and directed by Engineer-in-Charge
One light point controlled by two way switch 5 Amp complete all as specified and directed by Engineer-in-Charge.
One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq mm size complete all as specified and directed by Engineer-in-Charge.
One 3 pin socket outlet, 5 Amps on independent board with other switches, with cables 1.5 sq mm size complete all as specified and directed by Engineer-in-Charge.
One 3 pin socket outlet, 15 Amps on independent board with other switches, with cables 2.5 sq mm size complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with PVC FRLS insulated unsheathed multistranded copper conductor of size 1.5 Sqmm, 1100 Volts grade in existing concealed conduit, and one run PVC FRLS insulated unsheathed copper conductor of size 1.5 Sqmm as earth continuity wire and connected to common earth dolly with copper including provision of 1.2mm thick pressed steel sunken terminal boxes 60mm deep suitable length and painted with red oxide primer in place of unserviceable sunken box complete for housing switches, regulator, bell push etc and one light / fan point controlled by one way piano switch 5 Sqmps complete all as specified and directed by Engineer-in-Charge.
One socket point 5 Amps on an independent board complete all as specified and directed by Engineer-in-Charge.
One socket point 5 Amps on same board complete all as specified and directed by Engineer-in-Charge.
One light point wiring controlled by two, two way switches complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with PVC FRLS insulated unsheathed multistranded copper conductor of size 2.5 Sqmm, 1100 Volts grade in existing concealed conduit, and one run PVC FRLS insulated unsheathed copper conductor of size 2.5 Sqmm as earth continuity wire and connected to common earth dolly with copper including provision of 1.2mm thick pressed steel sunken terminal boxes 60mm deep suitable length for 15 Amp, 3 Pin socket outlet and painted with red oxide primer in place of unserviceable sunken box complete all as specified and directed by Engineer-in-Charge.
S & F for switch piano ,flush type single pole, one way 5 amp, complete all as specified and directed by Engineer-in-Charge.
S & F for switch piano flush type single pole one way 15/16 Amp complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs switch piano flush type single pole, two ways 5 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs of socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs of socket outlet 2 in 1, 3 pin 5 Amps and 15 Amps complete all as specified and directed by Engineer-in-Charge.
M & L for celling rose 3 pin / PVC / polycarbonate insulated body complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, of FTL LED type tube rod environmental friendly 1 x 18W / 20W, 230V, 6000K (4') complete all as specified and directed by Engineer-in-Charge.
S&F for LED batten with LED tube light integrated LED channel of capacity 10 Watt white colour complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanized earth turbo GI wire 4mm dia earth lead by means of bolts, nuts and washers of the earth strip galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel & wiremesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. complete all as specified and directed by Engr-in-charge. Notes :- (i) GI wire upto earth test point/ equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1 metre away from the outer edge of PCC chamber.
S & F for sheet metal enclosures for DBs double door type when MCBs to be used single pole & nuteral 8 ways complete all as specified and directed by Engineer-in-Charge.
S&F for MCB SPN 63 Amps, 240 Volts complete all as specified and directed by Engineer-in-Charge
S&F for MCB SP 6 to 40 Amps, 240 Volts complete all as specified and directed by Engineer-in-Charge
S&F in repairs, Sub main wiring with 2 single core 6 Sqmm PVC insulated flame retardant low smoke cable with multistranded copper conductor cable ISI marked in and including suitable size of PVC conduit medium quality conforming to 3537 Part-I & conduit accessories with and including independent PVC insulated one single core 6 Sqmm flame retardant low smoke un-sheathed and multistranded copper earth wire complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Cost of PVC conduit , conduit accessories and earth wire included in sub main wiring. (b) Three lengths of single core 6 Sqmm cable and suitable size of PVC conduit will be measured as one length)
S&F for pressure dia cast aluminium housing LED type street light fitting luminaries 15W / 18W / 20W, not less than 6000K clear transperent acrylic cover with IP 66, grey colour and fixing to wall with 25mm dia GI pipe bracket connected with suitable size of copper conductor complete all as specified and directed by Engineer-in-Charge.
Taking down existing main control board and supply and fixing CRCA steel metal board made out of 2.0mm thick and painting with 2 coats with synthetic enemel paint over a coat of red oxide primer including copper bus bar and fixed on wall for fixing arrangement of existing electronic meter incl internal connection with suitable sizeof copper conductor wire,and acessories, locking arrangementwith opening handle (minimum size of box 100cm x 80cm x 25cm) and adequate depth for the following equipments,internal wiring and termination of external cables, lugs and glands and conduit as required) comprising of following complete all as specified and directed by Engineer-in-Charge :- (a) Incoming 63 Amps 4 pole MCCB 36 KA - 01 No. (adj thermal and Magnetic release) (b) Bus Bar 200 Amps for Phase and neutral and earth bar Outgoing (c) MCB SPN 40 Amps - 04 Nos. (d) Taking down from existing distribution board and re-fixing only existing electronic meter single phase 15 to 40 Amps, 240 Volts on new distribution panel - 04 Nos.
S & F for GI tube light grade size 50 mm with all fitting and fixed to wall / pole or laid in floors for cable protection complete all as specified and directed by Engineer-in-Charge.
S&F for call bell ding-dong type, AC 230 Volts single pole complete all as specified and directed by Engineer-in-Charge.
S&F for bell push flush type 5 Amps complete all as specified and directed by Engineer-in-Charge
S&F for batton holder insulated body with back plate including 9 Watt LED lamp complete all as specified and directed by Engineer-in-Charge. --------------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,51,734.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 49(R) & 50(R)(R) (Schedule of Credit) of Tender document
RANDHIR AND COMPANY
M/s MITTAL CONSTRUCTIONS
POOJA CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .