| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹42.8 LAccepted-AOC | L 1 | Accepted-AOC AOC done | |
| 2 | L 2₹48.1 L+₹5.3 L (12.4%)Rejected-Finance | L 2 | Rejected-Finance L 2 | |
| 3 | L 3₹50.2 L+₹7.4 L (17.4%)Rejected-Finance VILLAGE DINAK P O KANAID TEHSIL SUNDERNAGAR | BILASPUR | HIMACHAL PRADESH | 174001 | L 3 | Rejected-Finance L 3 |
Tender Value
₹51.1 L
EMD Value
₹84,100
Closing Date
25 Jul 2022, 11:00 amClosed
Executive Engineer Electrical HPPWD Division Una
Executive Engineer Electrical HPPWD Division Una
.
2022_PWD_62487_1
TA/No. 2722-44 dated 28.06.2022
Open Tender
Electrical Works
Item Rate
730 days
Una
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
₹84,100
2 Sept 2024
7 Jul 2022
25 Jul 2022
7 Jul 2022
25 Jul 2022
7 Jul 2022
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. FRLS PVC insulated copper conductor single core cable as required. Make:- Legrand(Myrius), L&T(entice), Anchor (Roma classic ) as approved by Engineer-in -charge .
Group C.
Wiring for twin control light point with 1.5 Sq. mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. FRLS PVC insulated copper conductor single core cable as required. Make:- Legrand(Myrius), L&T(entice), Anchor (Roma classic ) as approved by Engineer-in -charge .
Group C.
Supplying and fixing following rating Modular switch /socket on the existing switch box / cover plate including connections but excluding modular complete etc. as required. Make:- Legrand(Myrius), L&T(entice), Anchor (Roma classic ) as approved by Engineer-in -charge .
S.P. 5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
S.P. 15/ 16 Amps one way Modular switch.
6 pin,15/16 Amps Modular socket outlet.
Telephone socket outlet, Modular.
Supplying & fixing following sizes modules, G.I. box along with modular base and cover plate for modular switches in recess ect. as required:-Make:- Legrand(Myrius), L&T(entice), Anchor (Roma classic ) as approved by Engineer-in -charge.Legrand(Myrius), L&T(entice), Anchor (Roma classic ) as approved by Engineer-in -charge .
1 or 2 module (75mmx75mm)
12 modules (200mmx150mm)
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required. Make:- Legrand(Myrius), L&T(entice) , Anchor (Roma classic ) as approved by Engineer-in -charge .
Supplying and fixing suitable G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amp modular socket outlet and 15/16 amps, modular switch, connections etc. as required. Make:- Legrand(Myrius), L&T(entice), Anchor (Roma classic ) as approved by Engineer-in -charge .
Supplying and fixing Computer board comprising metal box 12 module (200 mmx150 mm) for 3 nos each 5 amp modular switches & Sockets , metal box 2 module(75mmX75mm) for one no computer jack (RJ-45)with shutter including connections etc as required. Make:- Legrand(Myrius), L&T(entice), Anchor (Roma classic ) as approved by Engineer-in -charge .
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. Make:- Legrand(Myrius), L&T(entice), Anchor (Roma classic ) as approved by Engineer-in -charge .
Wiring for circuit/sub-main wiring along with earth wire with following size of FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit as required. Make:- KEI, Anchor, Plaza as approved by Engineer -in -charge .
2x2.5 Sq. mm + 1X2.5 sq.mm earth wire
2 x 4 Sq. mm.+ 1X4 sq.mm earth wire
2x10 Sq. mm.+ 1X6 sq.mm earth wire
2x16 Sq. mm.+ 1X6 sq.mm earth wire
4x16 Sq. mm.+ 2X6 sq.mm earth wire
Supplying and drawing following size of FRLS PVC insulated copper conductor single core cable in existing surface / recessed, Steel/medium class PVC conduit as required. Make:- KEI, Anchor, Plaza as approved by Engineer -in -charge.
3x1.5 Sq. mm.
3x2.5 Sq. mm.
3x4.0 Sq. mm.
Wiring for circuit/sub-main wiring along with earth wire with following size of FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit as required. Make:- KEI, Anchor, Plaza as approved by Engineer -in -charge .
2x1.5 Sq. mm + 1x1.5 sq.mm earth wire
Supplying and fixing PVC batten/angle holder including connections etc. as required.
Supplying and fixing call bell suitable for single phase, 230 V, complete as required.
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides, with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form. Make:- EVA/KSB/Power system & Controls or its equivalent as approved by Engineer-in -charge.
300 mm deep (nominal)
450 mm deep (nominal)
Supplying and fixing 4 pole MCCB 63 Amp Ics = 100% icu, 25KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required .Make:-L&T Cat. No. CM91712OOJOOG, Legrand, Hager, ABB or its equivalent as approved by Engineer-in -charge.
Supplying and fixing of 4 pole MCCB 125 Amp Ics = 100% icu, 25KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required. Make:- L&T Cat. No. (CM90642OOLO), Legrand, Hager, ABB or its equivalent as approved by Engineer-in -charge.
Supplying and fixing of 4 pole MCCB 200 Amp Ics = 100% icu, 36 KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required. Make:- L&T Cat. No. (CM90642OONO), Legrand, Hager, ABB or its equivalent as approved by Engineer-in -charge.
Supplying and fixing of 4 pole MCCB 320 Amp Ics = 100% icu, 36 KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required. Make:- L&T Cat. No. (CM98403OOROOG), Legrand, Hager, ABB or its equivalent as approved by Engineer-in -charge.
Supplying and fixing of 4 pole MCCB 400 Amp Ics = 100% icu, 36 KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required. Make:- L&T Cat. No. (CM98403OOROOG), Legrand, Hager, ABB or its equivalent as approved by Engineer-in -charge.
Supplying and fixing 4 pole MCCB 630 AMP Amp Ics = 100% icu, 36 KA & @ 415 volts, 50 Hz with Microprocessor release Mtx2.0 & ITRP3 conforms to IS/IEC 60947-2 complete with connection ,testing and commissioning etc as required. Make:- L&T Cat. No. (CM930070000AG), Legrand, Hager, ABB or its equivalent as approved by Engineer-in -charge.
Providing and fixing 200 Amp, four pole, 415 volts, On-Load change over switch unit, panel mounting, front handle operation, including drilling holes in the cubical, making connections, etc. as required. Make:- L&T (CODE:-CO22000OOOA), Legrand,Hager, ABB or its equivalent as approved by Engineer-in -charge.
Providing and fixing 400 AMP , four pole, 415 volts, On-Load change over switch in cubical panel front handle operation, including drilling holes in the cubical, making connections, etc. as required.Make:-L&T (CODE:-CO4400OOOO), Legrand, Hager, ABB or its equivalent as approved by Engineer-in -charge.
Supplying and fixing copper strip bus-bars suitable for following size & cross sectional area 415 volts capacity 4 No. each in the existing enclosure with all accessories including connections etc. as required:- Make:-EVA/KSB/Power system & Controls or its equivalent as approved by Engineer-in -charge.
Copper Bus Bar 63 Amp (20.4x3.17mm)
Copper Bus Bar 200 Amp (25.4x4.75mm)
Copper Bus Bar 400 Amp (38.10x6.35mm)
Copper Bus Bar 500 Amp (50.80x6.35mm)
Copper Bus Bar 800 Amp (50.80x9.50mm)
S/F indicator set RY &B with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required.
S/F Shock treatment chart on the existing wall etc as required including carriage of material within all leads and lift.
S/F rubber mat 1x2 meter long 12mm thick infront of main panel as required including carriage of material with in all leads and lift.
supplying and fixing CT coil 600/5 amp with burden of VA 15 accuracy class -1 Make:- Automatic Electric Ltd, L&T, Hager & ABB or its equivalent as approved by Engineer-in -charge. .
Providing and fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Supplying and fixing of 4 pole DU 125H/DU100D/DU125D/DNO MCCB Enclosure complete with connection testing and commissiong etcasrequired. Make:-L&T ( cat no-CM9O9960000), Legrand,Hager, ABB or its equivalent as approved by Engineer-in -charge.
Supplying and fixing of Segregated tripple pole and neutral 12 way, sheet steel MCB distribution board 415 Volt on surface /recess with provision to mount MCCB as incomer with provision of 125 amp insulated phase bus bar /neutral bar with shroud/s /earth bar sticking saddles cement spill protector /colour coded interconnected wire set /cable ties/blanking plate and circuit indentification labels .SP/TP MCB as out going , Powder painted including earthing etc as required. Make:- L&T (code-DBPGLOO12DD )/Legrand,Hager, ABB or its equivalent as approved by Engineer-in -charge.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, neutral bus bar, earth bar, din-bar, interconnections, and powder painted, including earthing etc. as required. ( but without MCB/RCCB/Isolator) Make:- L&T, Legrand, Hager, ABB or its equivalent as approved by Engineer-in -charge.
Double door-6 way
Double door-8 way
Double door-12 way
Double door-16 way
Supplying and erection of 5 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:Make L&T Legrand,Hager, ABB or its equivalent as approved by Engineer-in -charge.
Single pole
Supplying and erection of MCB DP 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required. Make:- L&T, Legrand,Hager, ABB or its equivalent as approved by Engineer-in -charge.
Double pole
Triple pole & Neutral
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:- L&T, Legrand,Hager, ABB or its equivalent as approved by Engineer-in -charge.
Supplying and fixing true power make advanced earthing system having copper pipe 3 meter long 50 mm dia with terminal size 50x6 mm ,internal strip size 25x3 with 50 Kg compound including exvation of pit and refiling the same and making earthing pit cover 12 inch dia as required complete in all respect. make :- True power ,Earth plus,Ashloka or its equivalent as per best satisfaction of Engineer-in -charge.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
Providing and fixing 4 mm dia. copper wire on surface or in recess for loop earthing as required.
Providing and fixing of lightning conductor finial, made of 20 mm outer dia. 1.2 mtr long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required. Make:- True power , Earth plus, Ashloka or its equivalent as per best satisfaction of Engineer-in -charge.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:- Make :- KEI, Plaza, Finolex, Havell's or its equivalent as approved by Engineer-in-charge.
Armoured cable 35 sq. mm (3.5 core)
Armoured cable 95 sq. mm (3.5 core)
Armoured cable 150 sq. mm (3.5 core)
Armoured cable 400 sq. mm (3.5 core)
Supplying and fixing LED. Lamp 9 watts E-27 base in the existing batten holder/pendent holder. Make:- Philips, Wipro or its equivalent as approved by Engineer-in -charge.
Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. Make:-Diplast/BEC/Polyfit or its equivalent as approved by Engineer-in -charge.
25 mm. dia
50 mm. dia
Supplying and fixing of PVC PIPE 100 MM dia of size along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- Make:- Diplast/BEC/Polyfit or its equivalent as approved by Engineer-in -charge.
Supplying and fixing of following sizes of steel conduit along with the accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. Make:- BEC/AKG/NIC or its equivalent as approved by Engineer-in -charge.
25 mm. dia
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit as required. Make:- Polycab, Finolex, D-link or its equivalent as approved by Engineer-in -charge.
Supplying and fixing of DLP 105x50 mmPVC adaptable trunking on the exiting wall at required height from lower level for power connection, light connection and net working connection including partition chip flexible cover end cap. Make:- Legrand ,MK or its equivalent as approved by Engineer-in -charge.
Supplying and fixing Surge protection device protection against indirect/direct lighting surges maxiumum dicharge current- I max upto 100 KA/ 3 pole+neutral Type 1+2 .Make :L&T(AUSP 123PN100),Legrand ,Hager, ABB or its equivalent as approved by Engineer-in -charge.
ARUN KUMAR SHARMA
Bhardwaj Electrical Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .