Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC 2 MT
SE EDC 2 MT
TNO.93/EDC2MT/2024-25
2025_PVVNL_1025603_2
TNO.93/EDC2MT/2024-25
Open Tender
Electrical Works
Lump-sum
180 days
EDD HASTINAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE EDC 2 MT
₹5,000
8 May 2025
25 Apr 2025
2 May 2025
25 Apr 2025
2 May 2025
25 Apr 2025
Amount
Cartage of the following material from central store Meerut to J.E. store including loading & unloading at both ends (maximum distance up to 50 km.)
1-P.C.C. Pole 8.5 Mtr. Long.
2-P.C.C./Round Pole/ST Pole 9.5/11 mtr. Long.
3-Line material such as 11 K.V. cross arms/11 KV Pin insulator/conductor/GI Wire/MS angle & MS channel/stay wire/stay rod, disc fitting etc.
Cartage of the following material from store J.E. to site of work including loading & unloading at both ends (maximum distance up to 10 km.) 1-P.C.C. Pole 8.5 Mtr. Long.
2-P.C.C./Round Pole/ST Pole 9.5/11 mtr. Long.
3-Line material such as 11 K.V. cross arms/11 KV Pin insulator/conductor/GI Wire/MS angle & MS channel/stay wire/stay rod, disc fitting etc.
Safe cartage of Transformer from central store Meerut to J.E. store of work including loading & unloading at both ends (maximum distance up to 50 km.) 1-250 KVA
2-63 KVA to 100 KVA
3-10 KVA to 25 KVA
Safe cartage of Transformer from J.E. store to site of work including loading & unloading at both ends (maximum distance up to 15 km.) 1-250 KVA
2-63 KVA to 100 KVA
3-10 KVA to 25 KVA
Erection of Round Pole/P.C.C. Pole 8.5 Mtr. Long including fixing all accessories and fabrication as required after digging a pit of size 1.20X0.75X1.75 Mtrs. 1-PCC Pole8.5 Mtr.Long
2-P.C.C./Round Pole/ST Pole 9.5/11 mtr. Long.
Erection of D/P on PCC/Round Poles after digging of pits of size 1.20X0.75X1.75 Mtrs including fabrication of Structure as per RESPO norms.
Earthing of PCC support with MS Earth rod of 2.5 Mtr. Long including excavation of pit & driving of MS rod up to proper depth & connection the earth electrode with the help of GI wire.
Laying Lifting stringing and sagging of conductor complete in all respects as per RESPO norms. 1-Rabbit Conductor.
2-Weasel Conductor.
Erection fixing & grouting of stay rod size 16X1800mm after digging the pit of size 0.60X0.30X0.30 meter in ratio 1:4:8 including fixing of stay wire clamp and nuzzling at the both ends.
Mounting of 11/0.4 KV T/F on plinth & making connection of PVC Cable & Lead of HT/LT line. 1-250 KVA
2-63 KVA to 100 KVA
3-10 KVA to 25 KVA
Providing & fixing of following clamps for PCC Pole/STP, made of MS flat of size 50X6mm complete in all respect. 1-LT Pin Clamps with nut & bolt.
2-Shackle Insulator with nut & bolt.
3-Double Pole Clamps with nut & bolt.
Providing & fixing of stay clamp for PCC Pole/STP made of MS flat of size 50X6 mm complete in all respect.
Providing & fixing of Stay insulator in stay wire as per site requirement.
Providing & Fixing of F-Clamp for PCC Pole/STP made of MS flat of size 50X6mm with nut & bolt.
Providing & fixing of cross arm holding clamp for PCC Pole/STP made MS flat of size 50X6mm with nut & bolt.
Making section T-off for 11 KV/LT Line.
Cutting & Chopping of tree branches.
Jumpering of 11 KV/LT Line at different places/T points.
Guarding of 11 KV Line as per norms.
Cartage of ABC Cable with junction Box & other store materials related with the work of ABC for each site/Transformer.
Laying Lifting of ABC Cable complete in all respect as per instruction of J.E./SDO.
Fixing of Junction Box & making connection & other related works.
Fixing of metering cubical & making connection & other related works.
Water level Earthing (Neutral/Body) by providing & fixing 30 mtrs 30 mm dia GI Pipe with MS Strip 40x6 mm. lowering the same after boring of earth by 4" dia upto 30 mtr depth/water level.
Providing D-Type loop on each face & neutral.
Providing & fixing of bamboo sticks of required size on LT Line as per instructions of JE concerned.
Laying of 11 KV XLPE Cable between D.P. and metering cubical/Control Pannel including the work of digging of cable trench for laying the cable and filling of earth after covering the cable by bricks & sand around it.
Safe cartage of Weasel/Rebbit/Dog Conduter from site of work to J.E. store to Centarl Store including loading & unloading at both ends (maximum distance up to 50 km.)
Safe cartage of PCC Pole 8.5 mt/ST Pole 11/13 Mtr from site of work to J.E. store to Centarl Store including loading & unloading at both ends (maximum distance up to 50 km.)
Making new Fencing for 250/400 KVA T/F. for installation Sifting T/F. as per RESPO Norms (all the material used shall be Provide by the Contractor).
Making new Plinth for 250/400 KVA T/F. for installation Sifting T/F. as per RESPO Norms (all the material used shall be Provide by the Contractor).
M/s Electrical Engineers (BID ID -5159531)
M/S CAPITAL A B C AND SONS (BID ID -5160759)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .