| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | L1 | Accepted-AOC RATES QUOTED ARE REASONABLE | |
| 2 | L2₹16.0 L+₹65,725 (4.30%)Rejected-Finance 1273 CUTINO ROAD KARWAR 581301 | KARWAR | UTTARA KANNADA | KARNATAKA | 581301 | L2 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 3 | L3₹16.7 L+₹1.4 L (9.04%)Rejected-Finance | L3 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 4 | L4₹17.1 L+₹1.8 L (11.7%)Rejected-Finance | L4 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 5 | L5₹17.7 L+₹2.4 L (15.5%)Rejected-Finance | L5 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Feb 2023, 6:00 pmClosed
GARRISON ENGINEER (SEABIRD) KARWAR
GARISSON ENGINEER (SEABIRD) KARWAR
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION FITTINGS AND FIXTURES, INCLUDING EARTHING OF MARRIED / OTM ACCNS INCLUDING E/M INSTALLATIONS AT AMDALLI TOWNSHIP UNDER GE(SB) KARWAR
2023_MES_576214_1
8972/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GARRISON ENGINEER (SEABIRD) KARWAR
AS PER NIT
7 documents required · 7 mandatory
₹500
GARISSON ENGINEER (SEABIRD) KARWAR
₹50,000
Yes
7 Mar 2023
20 Jan 2023
15 Feb 2023
20 Jan 2023
13 Feb 2023
6 Feb 2023
20 Jan 2023 - 3 Feb 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in existing conduit and making good disturbed surfaces to match with the existing surface for the following point complete all as specified and directed by Engr-in-Charge.
(a) One light/fan point controlled by one switch
(b) One 3/5 pin socket outlet 6 Amp on same board with other switches.
All as per item No.2 above but One 3 pin socket outlet 5 Amp on independent board.
All as per item No.2 above but with cables 2.5 Sqmm for one 3 pin socket outlet 15 Amps on independent board
All as per item No. 2 above but with cables 4 Sqmm for one 3 pin socket outlet 15 Amps on independent board
Supply & fix in repairs MCB TPN, 16 To 32 AMP, 415 Volts, 3 phase, 10 KA Capacity all as specified and directed. MAKE: Havells/L&T/Legrand/ABB/Seimens or as approved by GE.
Supply & fix in repairs MCB TPN, 40 To 100 Amps, 415 Volts, 3 phase, 10 KA Capacity all as specified and directed. MAKE: Havells/L&T/Legrand/ABB/Seimens or as approved by GE.
Supply & fix in repairs MCB SPN, 32 Amps, 'C Series ,230 Volts, Single phase, 10 KA Capacity all as specified and directed. MAKE: Havells/L&T/Legrand/ABB/Seimens or as approved by GE.
Supply & fix in repairs MCB SP, 5 to 32 Amps, 'C' Series,230 Volts, Single phase, 10 KA Capacity all as specified and directed. MAKE:Havells/ L&T/ Legrand/ ABB /Seimens or as approved by GE.
Taking down ceiling fan/exhaust fan of any sweep, dismantling, replacing defective part, overhauling, cleaning, greasing, rewinding, etc and hanging up/fixing back in the original position, connecting up and testing complete all as directed. NOTE: 1. The unit rate quoted shall be deemed to include for minor items viz nuts,bolts split pin and rubber wheel, however capacitor & bearing shall be measured sperately under respective items. 2. Rewinding of fan will be measured and paid for separately under respective items.
Supply and fix in repairs ceiling fan regulator electronic step type 230 Volts single phase all as specified and directed. MAKE: Anchor/Bajaj/Legrand/Havells.
Supply and fix in repairs capacitor of 2.5 mfd for ceiling fan/exhaust fan complete all as specified and directed. Make: Havells/Bajaj/Crompton Greaves/Phillips.
Supply and fix bearing No.6201/6202/6203 for ceiling fan/exhaust fan complete all as directed. Make: SKF/TATA or as approved by GE.
M & L for removing of burnt out copper winding wire from ceiling fan of any make and size of 1200 mm to 1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material, varnishing and drying complete all as specified and directed.
M&L for Painting of ceiling fans complete, in situ/ lying in store with synthetic enamel paint (white colour) by spraying including filling cavities with filler, one coat after cleaning all dust etc
S&F in replacement of cup made of plastic complete with nut bolt for fixing in position suitable for ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
S&F in replacement of blade suitable for 1200mm sweep Ceiling fan complete all as directed.
S&F in replacement of blade suitable for 1400mm sweep Ceiling fan complete all as directed.
S&F in replacement of ceiling fan downrods of length 1-2 ft suitable for 1200/1400mm ceiling fans. The quoted rate should also include for the clamps necessary for the proper fixing of the ceiling fan complete all as specified and directed.
All as per item No 11.00 here in before but exhaust fan of 300 mm sweep complete all as specified and directed.
All as per item No.11.00 here in before but exhaust fan of 450 mm sweep, 3 phase 415 Volt complete all as specified and directed.
Taking down submain wiring cable any number of runs alongwith earth wire from the existing concealed or surfacae conduit and offering credit as per schedule of credit all as directed.
M&L for Wiring circuit/submain wiring alongwith earth wire with 2x6.0 sq. mm +1x6.0 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required In existing steel/conduit, casing/caping, surface/ recessed complete all as specified and directed by Engr-in-Charge.
M&L for Wiring circuit/submain wiring alongwith earth wire with 2x6.0 sq. mm +1x6.0 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required In casing/capping complete all as specified and directed by Engr-in-Charge.
M&L for Wiring circuit/submain wiring alongwith earth wire with 2x4.0 sq. mm +1x4 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required In casing/capping complete all as specified and directed by Engr-in-Charge.
S & F in repairs MCB DB TPN 415 Volt 4 way & single door and factory made complete with bus bar and din channel complete all as directed. MAKE: Havells/ABB/Legrand/Schneider/L&T or as approved by GE.
Supply and fix in repairs switch Piano 6 Amps one way flush type, matching with existing make, ISI marked, complete all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs socket outlet 3/5 pin 6 Amps flush type, matching with existing make ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs switch Piano 15/16/20 Amps one way flush type, matching with existing make ISI marked, complete all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs socket outlet 3/5 pin 15/16 Amps flush type multi purpose, matching with existing make ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs switch socket combination 5 pin 16 Amps flush type multi purpose, matching with existing make ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs 2 way switch piano 5 or 15 Amps flush type single pole ISI marked all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs Calling Bell/Buzzer Ding Dong 230 Volts AC Single pole matching with existing make with ISI marking, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and Fixing in repairs Bell Push flush type 230 Volts 5 Amps comfortable with existing Door bell matching with existing make ISI make, complete all as directed and specified. MAKE: Havells/Anchor/Legrand/Phillips.
Material and labour for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. MAKE: Havells / Anchor / Legrand/Phillips.
S&F in repair Inverter LED 20W light, white colour temperature 6500K along with batten consisting of a Lithium Ion battery with charging time 8-10 hours and back up time upto 4 hours complete with all connected accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells/Bajaj/Philips/ Wipro/ C&S/ Shakti or as approved by GE
Supply &Fxing n repiar 18/20 W LED batten suitable for T8 LED retrofit tube 4' with LED tube rod 18/20W, 230 Volts, complete with all connected accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells/Bajaj/Philips/ Wipro/ C&S/ Shakti or as approved by GE.
S&F in repair T8 LED tube rod 18/20 W, 4 feet length, 6000K complete with all accessories as specified and as directed. Make : Havells/Bajaj/Philips/Wipro/Shakti/C&S or equivalent.
S&F in repair 10 watt LED light fittings 2 feet including making necessary connection complete all as specified and directed. Make : Havells/Philips/C&S/Bajaj/Shakti or equivalent.
S&F in repairs MCB DB SPN, 8 way, 240 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed. Make : Havells/Indo Asian / Legrand or equivalent.
M & L for testing of resistence of earthpits of transformer / panels/ buildings or any other indicated place etc after testing report will be furnished to Engr-in Charge in standard format approved by Engr-in Charge.
M & L for earthing complete with galvanized steel earth electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead by means of nuts, bolts, checknuts and washers of galvanized iron or steel as shown in electrical plate No 3 connected to earthing test point including testing on completion all as specified and directed. NOTE: The unit rate quoted shall be deemed to include for necessary excavation and earth work in any type of soil, PCC 1:3:6 type CI chamber, funnel with GI medium grade watering pipe 15 mm bore, RCC 1:2:4 type B1 in cover slabs 50 mm thick with 8 mm dia TMT bars @ 140 mm c/c both ways etc complete.
M&L for taking down the existing faulty single phase tamper proof Electronic Energy meter with LCD display 230 volts 4 wire system, 10-60 amps, 50 Hz ,replacing the unserviceable chip board complete,making it to serviceable state, including testing, caliberation & refixing the same complete all as specified and directed by Engr-in-Charge.
M/S VERNEKAR AGENCIES
BROTECH
M/S DK Enterprises
SHRI MALLIKARJUN BATTERY AND ELECTRICAL WORKS
Raheel Enterprises
M/S. B G GAONKAR
ANKIT SHIP REPAIRERS AND SUPPLIERS
PEGASOS ENGINEER TRADERS
H S krishna Electricals
SHREE KESHAV NARAYAN ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .