Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | ₹31.3 L Quoted ₹32.1 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹34.6 L+₹2.5 L (7.87%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | ₹34.6 L+₹2.5 L (7.87%) | L2 | Rejected-Finance Rejected being other than L1 |
| 3 | L3₹41.1 L+₹9.0 L (28.2%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | ₹41.1 L+₹9.0 L (28.2%) | L3 | Rejected-Finance Rejected being other than L1 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
20 Apr 2021, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR MAINT OF DG SETS AND CONNECTED WORKS AT SECTOR C AND ADJACENT AREA UNDER GE 865 EWS
2021_MES_432183_1
865/EWS-107/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹90,000
Yes
12 Jun 2021
20 Mar 2021
22 Apr 2021
20 Mar 2021
20 Apr 2021
6 Apr 2021
Amount
Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comparising of Engine/ Alternator/ Control panel) of the following capacity for smoth functioning complete all as per manufacturers instructions and all as directed by Engg - In - Charge A. (a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same (c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tenson properly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance (g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of starter motor battery and charger (i) Checking of cooling system and fuel system (j) checking of all power cables and AVR connections and mounting bolt tightnees of alternator (k) checking the function of AVR genaral checks (l) Checking of control panel meters and gadgets functiong (m) Checking of all control and safety wirings B. (a) Checking of flexible coupling of engine and alternator (b) Cleaning of crank case ventilation pipe (c) Checking of injectors and fuel pump (d) Checking of alternator and carbon brushes of following capacity DG sets NOTE (1) Cost of Spares required will be paid and measured separately (2) Servicing/routine check up carried out through authorised service centre of manufacturer (4) Make of spare recommendation by auth service centre of manufacturer
1010 KVA DG Sets
500 KVA DG Set
380 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
M & L for changing /toping up of best quality of engine oil 20W40 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed. Make: Castrol/Veedol/Valoline
S&F in replacement of Oil filter element as per existing for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge. Make- Kirloskar/Mico/TVS
1010 KVA DG Sets
500 KVA DG Set
380 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement of Air cleaner element (inner and outer) suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Sets
500 KVA DG Set
380 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement of Fuel filter elements(primary & secoundery) for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Sets
500 KVA DG Set
380 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement of 'V' belt for water pump suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Sets
500 KVA DG Set
380 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement of fuel pipe with banjo bolt at both side suitable for following capacity DG sets make: Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Sets
500 KVA DG Set
380 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement of Dynamo Assy for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement of auotmatic voltage regulator(AVR) 240 volt suitable for following capacity of DG Set. Cat Part No F680902000 Make -Kirloskar
500 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement of self starter for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement of water pump assembly for following capacity DG sets make : Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement of Turbo charger assy.for following capacity DG sets make cummins complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement of Fan Hub assembely for following capacity DG set make cummins/Kirloskar/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Sets
500 KVA DG Set
380 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
M&L for disconnecting the U/S DC alternator of following capacity DG Set, 3 phase any make & type from engine, transporting to workshop dismantling it for repairing and rewinding by taking out burnt armature winding aleaning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves, varnishing cotton taping etc reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engr-in-Charge.
500 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
M&L for taking out burnt winding of exciter of following capaicity of DG sets including re-winding copper wire of super quality, of existing size, No of turns, varnishing, heating complete including testing on full load complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
Note for Item Sr. No 14 and 15 here in above -: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.
S&F in replacement of lub oil pump suitable for following Capacity DG Sets,make :Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
140 KVA DG Set
62.5 KVA DG set
S&F in replacement of thermostate valve suitable for following Capacity DG Sets make Kirlosker/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement of Oil seal front and rearsuitable side for following Capacity DG Sets make Kirlosker/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
380 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement Battery 12 Volt 180 AH (Maint free heavy duty with initial charging.Make- Exide/Amron.all as specified and directed by Engr-in-Charge
M &L for Removing the fuel injection pump (FIP) & injectors from following capacity of DG sets and carry out servicing and calibration including S&F in replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning all as directed by Engr-in-Charge. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set.
500 KVA DG Set
380 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
M & L for dismantling the defective radiator assembly and taking it to contractor workshop for cleaning of radiator , finding the leakages by pressure method and providing leak proof treatment to defective radiator assemble by welding/brazing/glazing suitable material for cohesiveness for following capacity DG sets cleaning radiator by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and Re-assembling after painting of the same complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Sets
500 KVA DG Set
380 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
S&F in replacement of battery charger 12 Volt,10 Amp and making all electrical connection testing complete all as directed
S&F in replacement of battery charger 24 Volt, 10 Amp and making all electrical connection testing complete all as directed
S&F in replacement of broken door hinges/handles of acoustic enclosure of 1010 KVA DG Set complete with manufacturer recommended handles/hinges using nut bolts etc as per site requirement of any type and make of DG set all as directed at site.
S&F in replacement of broken door hinges/handles of acoustic enclosure of 380 KVA DG Set complete with manufacturer recommended handles/hinges using nut bolts etc as per site requirement of any type and make of DG set all as directed at site.
Materials and labour for scraping removing and cleaning old rusty paint from body of DG set of following capacity any make by cleaning agents & painting the DG set complete with Polyurethane (PU) paint as specified and directed at site by Engr-in Charge.
500 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
Taking down old rusted unserviceable silencer single/double with exhaust pipe and S&F in replacement new silencer with Exhaust pipe complete bends, coupling etc suitable for following capacity of DG set including fixing arrangements and painting with silver paint and insulating with suitable size and length of asbestos rope complete all as specified and directed by Engr-in-Charge.
500 KVA DG Set
140 KVA DG Set
110 KVA DG Set
62.5 KVA DG set
Supply, fixing in replacement and testing of PCB of digital controller panel of 1010 KVA Cummins DG set having cat part No PCC3300 as per sample complete all as specified and directed by Engr-in-Charge.
Supply, fixing in replacement testing of PCB card controller of type Auxillary 105 suitable for PCC3300 of digital controller panel of 1010 KVA Cummins DG set as per sample complete all as specified and directed by Engr-in-Charge.
Labour, service and calibration charges of PCB card PCC3300 type with DG set digital panel controller card complete and testing on completion showing the working condition of all finger tip control features of the 1010 KVA Cummins DG Set all as specified and directed by Engr-in-Charge.
S&F in replacement and testing of control relays and connected control wirings using suitable size AC/DC cables of sizes for 1010 KVA DG set digital control monitoring panel done by OEM recommended technician/wireman and testing complete all as specified and directed by Egr-in-Charge.
S&F in replacement for wiring harness having cat part No : AO34X423 for suitable size wires to be used for 1010 KVA DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 320 AMP, TPN Cat part No : IHCFFE0320 of Havells equivalent in ABB/Schneider/L&T/Legrand complete all as specified and directed by Engr-in-Charge.
S&F in replacement Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 400 AMP, TPN Cat part No : IHCFFE0400 of Havells equivalent in ABB/Schneider/L&T/Legrand complete all as specified and directed by Engr-in-Charge.
S&F in replacement Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 630 AMP, TPN Cat part No : IHCFFE0630 of Havells equivalent in ABB/Schneider/L&T/Legrand complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Air pipe (Turbo to Radiator) for any capacity of DG Set
S&F in replacement of bty charging alternator (12 volt) with 2 wire system for any capacity of DG Set
S&F in replacement of Digital RPM meter with Hour meter for any capacity of DG Set
S&F in replacement Air cleaner assembly kit for 1010 KVA DG set
S&F in replacement stainless steel, Grey colour anti-vibration support pads for isolating the DG Set engine and alternator from the mounting frame having weighing capacity upto 400 Kgs each for suitable capacity of DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement of battry terminal for DG Sets complete all as specified and directed by Engr-in-Charge.
S&F in replacement battery cable assy. with copper conductor multistranded RED and BLACK colour 2mtr long 21sqmm for connection to self starter unit to Battery unit complete.
Supply & toping up of best quality anti freezing,Inhabitor Corrosion (Coolant ) liquid for DG set at varrious capacity and locations complete all as specified and directed. Make-Castrol/Veedol/Valoline
M & L for changing /toping up of best quality of engine oil 15W40 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed. Make-Castrol/Veedol/Valoline
Note :- Makes of spare parts to be replaced under this work and mentioend in relevant items in this BOQ here-in-before shall be of approved make and as per the manufacturer's recommendation of DG sets and other equipments.
R B TRADERS
EESSI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .