Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹39.3 LAccepted-AOC HAMILTONGANJ NETAJI PALLY NEAR ICE FACTORY DISTT ALIPURDUAR WEST BENGAL 735 214 | ALIPURDUAR | WEST BENGAL | 735214 | 1 | Accepted-AOC L 1 Bidder | |
| 2 | 2₹43.6 L+₹4.0 L (10.2%)Rejected-AOC | 2 | Rejected-AOC Other than L1 Bidder | |
| 3 | 3₹43.9 L+₹4.3 L (10.9%)Rejected-AOC 777 778 SASTRI NAGAR SARAT SARANI SUBHASPALLY BURNPUR BARDHAMAN WEST BENGAL 713325 UDYAM WB 23 0020628 | PASCHIM BARDHAMAN | WEST BENGAL | 713325 | 3 | Rejected-AOC Other than L1 Bidder | |
| 4 | 4₹44.0 L+₹4.4 L (11.2%)Rejected-AOC | 4 | Rejected-AOC Other than L1 Bidder | |
| 5 | 5₹44.2 L+₹4.7 L (11.8%)Rejected-AOC DS COLONY BINNAGURI TG ROAD OPP MILAN SANGH CLUB POST BINNAGURI DISTT JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | 5 | Rejected-AOC Other than L1 Bidder |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
30 Nov 2023, 6:00 pmClosed
GE (SOUTH) BINNAGURI
GE (SOUTH) BINNAGURI, PO - BINNAGURI, DISTT - JALPAIGURI, PIN - 735232
PROVISIONS AND CERTAIN SPL REPAIR WORKS AT HASIMARA AND COOCH BEHAR MIL STN UNDER GE (S) BINNAGURI
2023_MES_626393_1
8618/E8
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) BINNAGURI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (SOUTH) BINNAGURI
₹81,000
Yes
5 Mar 2024
2 Nov 2023
2 Dec 2023
2 Nov 2023
30 Nov 2023
16 Nov 2023
Amount
Surface excavation n exc 30cm deep and average 15cm deep and getting out in soft/ loose soil.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5 m depth in soft /loose soil etc complete all as specified and directed
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil etc complete all as specified and directed
Removal of excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L fly ash Brick work using modular size bricks with sub class 'B' bricks curved on plan with mean radius not exc 6m with bricks roughly cut to radius or bricks with wedge shaped joints built in cement mortar 1:4 complete all as specified and directed.
Demolition of cement concrete reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for RCC (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed . Note - Reinforcement and form work shall be measured and paid separately.
Form work to sides of concrete foundation ,footings, bases of columns, raft and raft beams sides and soffits (if any )of foundation and plinth beams for flat rough finished concrete surface complete all as specified and directed.
M&L for RCC (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregate as in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately.
Form work to sides and soffits of floor or roof beam, beam hauchings, girders, bressummers, lintels, cantilevers, shelves, for flat rough finished concrete surfaces complete all as specified and directed.
M&L for RCC (nominal mix) 1:2 :4 type B using 20 mm graded stone aggregate as in slab supported/Chajjas as in simiar works Note - Reinforcement and form work shall be measured and paid separately.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed
Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild Steel TMT bar 6 to 8 mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild Steel TMT bar 5mm dia and over upto and including 10mm dia as in stirrups, spacers & binders cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:4 complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St -240 and painted one shop coat of zinc chromate primer paint including preparation of surface at contractor workshop before fabrication complete all as specified and directed.
S&F MS steel Hollow section Square/rectangular as in roof truss ,purlin,rail etc etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St -240 and painted one shop coat of zinc chromate primer paint including preparation of surface at contractor workshop before fabrication complete all as specified and directed.
S&F Rolled mild steel in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed.
S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding/ eaves board fixed with selp tapping screw complete all as specified and directed.
Dismantling of wall and ceiling Boards(Fiber,pulp, Insulation etc) or insulation Board/slab/blankets any Thinkness including cover fillets complete all as specified and directed.
M&L for non Asbestos ,fibre reinforced standard cement board as in celiling ,4mm thick designer board (610mm x 610mm ) including hot dip GI heavy duty suspended ceiling grid system T-2420 all as specified and as directed
S&F Anodised aluminium snap grid frame work for false ceiling all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
S & f Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colouredcement to match over 15mm thick screed bed in CM 1:6
S & f Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colouredcement to match over 10mm thick screed bed in CM 1:6 in vertical srface
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges steel peg stay complete all as specified and directed
Dismantling timber scantlings 40 sqcm and over in section as in framed work in any position complete all as specified and directed.
M&L for second class hard wood (SAL) in scantlings clean swan in framed work as in rafter purlines etc complete all as specified and directed.
Taking down chowkats or frames not exc 1.5 Sqm each with shutters ( with out taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames exc 1.5 sqm but not exc 4.0 Sqm each with shutters ( with out taking off shutters from the frames) complete all as specified and directed.
S&F 35 mm thick second class hard wood rail and style plain framed factory made panelled shutter (two panel) with lock rail and panel of 9 mm BWP commerical ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L Second class hard wood 30 mm thick factory made glazed and skeleton shutters, open rebated and prepared to receive glass , gauze etc with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.20 (a) complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F Butt hinges, medium weight, cold rolled mild steel 125mm long complete all as specified and directed.
S&F mild steel barrel tower bolts stove enamelled black with bright bolt 125 mm long complete all as specified and directed.
S&F mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate of 250 mm length of bolt complete all as specified and directed.
S&F Brass handle polished type anodised of 125 mm size complete all as specified and directed.
S & F factory made solid panel PVC door shutter 30 mm thick style consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, S & F in the frame as shown on drawing in section 8 of SSR-2010 Part-II complete all as specified and directed
S & F for solid PVC door frame of size 50x47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, supplied and fixing in opening as specified and shown on drawing made on section 8 of SSR 2010 Part-II complete all as specified and directed
S&F Butt hinges, medium weight, cold rolled mild steel 100 mm long complete all as specified and directed.
S&F aluminium, anodised, barrel tower bolts of extruded section 100 mm long complete all as specified and directed.
S&F aluminium handles cast type anodised of 100 mm size complete all as specified and directed.
S& F in repairs 5mm thick printed colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site complete all as specified and directed.
S&F Powder coated anodised aluminium window sliding type three track aluminium sections weighing not less than 0.55 Kg per mtr (Two glazed shutter & one wire mess shutter) including necessary jointing cleats, glazing cleats, rubber packing anodised aluminium snap gridding, screws, handle, locking arrangement etc complete and 5.5 mm thick plain or tinted glass complete all as specified. (Make : Jindal/Hindalco/Indal).
S&F powder coated anodised aluminum frame of size 100 x 44 x 1.5 mm thick made of square tubler coated alumunium Section for doors with one or more rebates, jointing cleats for fixing etc and provision of alumunium door shutter (Single/Double shutter) incl. jointing cleats, glazing clips, rubber gasket aluminium anodised snap beading, srews hold fast, floor stopper, locking arrangement, handle of size not less than 200mm, 5.5mm thick tinted glass fixed in panels with miniumum 3 nos aluminium hinges 100mm long for one shutter etc complete all as specified. (Make : Jindal/Hindalco/Indal).
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings,frame work of watertanks and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying three coat of white wash complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 15 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings laid in trenches of 20 mm bore of pipe complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75 mm bore with out access door complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or un equal of 110 mm bore of pipe with access door complete all as specified and directed
S&F PVC (SWR) bends any radius of 110 mm bore complete all as specified and directed.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F vitreous china EWC white with 'P' or 'S' trap front or back inlet any pattern excluding flushing cistern & flush pipe but including plastic water closet seat black closed pattern with flat bottom and cover and hinging device complete all as specified and directed.
S&F wash hand basin vitreous China, white, flat back (550x400mm) including cutting for and pinning ends of brackets and waste coupling of Bass CP for basin etc with long screwed shanks and fly nuts, full threaded flage embedded in white cement incl PVC waste pipe required length complete all as specified and directed.
S & F in Vitreous China bowl urinal flat back, size of 430 x 370 x 340 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)
S&F PVC 10 litres capacity valveless ,syphonic action type low level flushing cistern ,white including flush pipe, cantilever brackets ,inlet, ball valve, float and handle, etc complete all as specified and directed.
S & F 15mm size PVC Connection with PTMT nut of length 450mm , complete all as specified and as directed.
Stop cock cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferule of 15 mm bore, complete all as specified and directed.
S&F Bib taps (long body )fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule all complete as specified and as dierected.
S&F sheet glass shelf assembly consisiting of 5.5 mm thick sheet glass shelf 12mm wide with CP brass bracket guard railing 60cm long, complete all as specified.
S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F of PVC (SWR) floor trap, plain with grating including jointing with solvent cement outer dia 75 mm cement concrete (1:2:4), type B1 including complete all as specified and as directed.
S& f plastic water tank 1000 ltr capacity with all neccerry like 20mm boll etc
S&F in repair Harrison rails (curtain), mild steel, chromium plated with fixing brackets stops, rollers etc complete all as specified and directed
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for sand filling under floor or in foundations including watering and consolidation complete all as specified and directed
M&L for 100 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in floor finishes 40 mm thick laid in panels & finished even and smooth without using extra cement complete all as specified and directed. Note- Glass dividing strips shall be measured & paid separately as supply only.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate, 75mm thick in plinth protection and footpath laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed. Note : Joints 12mm wide to the full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provision shall be deemed to be included in the quoted rate for concrete in plinth protection.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 110 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate complete all as specified and directed.
M & L for cement concrete type C2 (1:3:6) (using 40 mm graded stone aggregate) in surface channels,mass concrete drains and manhole foundation etc.
M&L for providing cement concrete type B-0 (1:2:4)(using 20 mm size graded aggregate) in coping set incl weathering, slightly rounded or chamfered angles & thickness.
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) assub base finished concrete surfaces even and rough to receive floor finishes incl necessary form work complete all as specified and directed.
M & L 80 mm thick M-40 grade factory made vibratory compacted cement concrete rubber moulded, interlocking paver block any shape and size confiroming to IS 15658-2006 with grey cement and pigment as approved laid over and incl 25 mm thick consolidated sand cushion and joints filled with sand complete all as specified and directd.
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar (1:6) finished even & fair.
M&L for external rendering 20 mm thick in two layer, first layer shall be of 10 mm thick CM 1:6 and second layer of finishing coat shall be 10 mm thick in CM 1:4 mixed with WPC @3% by weight of cement on brick work or concrete surfaces of wall and finished even and fair complete all as specified and directed. Note-WPC shall be measured and paid seperately.
M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick or concrete surface of wall and finished even and smooth with out using extra cement complete all as specified and directed.
Supply only integral water proofing compound all as specified and directed.
M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for applying two coats of acrylic distemper on newly plastered wall surface including preparation of surface over a coat of 1mm thick Birla wall care putty complete all as specified and directed.
M&L applying two coats of cement base paint of standard quality and make ,over a coat of white primer including preparation of new /old wall surfaces complete all as specified and directed.
M&L applying three coat of white wash including preparation of new wall surfaces
M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed by Engr-in-Charge.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed by Engr-in-Charge.
Supply installation, commissioning and testing of electric water heater, storage vertical type, BEE 5 star rated 50 ltrs capacity 230 volts AC 50 Hz comprising of high wattage heating element for instant heating,non-ferrous pressure plate with and including provision of 04 Nos grouting bolts suitably flush to wall or any other surfaces and connection pipe for hot and cold water supply 50 lts BEE 5 Star rated complete stranded copper conductor cable/ flexible chord complete all as specified and as directed.(Make: Havells, Code.GHWAMGSWH050 or Bajaj ,Crompton or equivalent).
M&L bib taps , cast copper alloy with butterfly handle , screwed down, screwed for iron pipe or for brass ferrule and fixed for bib tap 15 mm dia fancy type all as specified and as directed.
M&L for point wiring complete for one power point for one metal plug & socket for AC or one socket for geyser point on independent board with 4.0 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 4.0 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, including cutting chases of existing wall for conduits and fixing for Metal Plug and socket boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles.
S & F Socket outlet 2 in 1,3 pin 15 Amp, flush type complete all as specified
S & F switch piano type one way, flush type 15 Amp complete all as specified
S&F MCB distribution boards (DBs) with sheet metal enclosure, single door, IP 43 protection, 240 Volts, 2 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, ertth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and as directed.
S&F MCB, Single pole & neutral, 5 to 32 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one as specified and as directed.
Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE : Two runs of 4 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) Note: Excavating & PCC work shall be measured and paid separtley under relevnt item.
M&L for street light bracket, made out of GI pipe 40mm bore medium grade made to shape length not less than 1.2 m including necessary clamp,nuts & bolts and two coats of Aluminium paint over a coat of Red oxide primer all as specified & directed.
S & F cable Junction box of size 155×210×92 mm for street light pole with GI clamps to fix on steel tubular pole with cable entry of 10-16 sq mm with suitable size of terminals, complete all as directed. Make:Hensel or equivalent ISI marked make
Materials and labour XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- sectional area 10 sqmm 4 core.Note : Excavation and earth work will be measured and paid separately (Make :KEI/ HAVELLS / NICCO / POLYCAB)
S & F GI tubing light grade 40mm dia for protection of cable passing through duct/road crossing/on pole/on wall etc incl all fittings and fixing arng like clamp made out of 40mm x 3mm flat iron and nut bolts all as specified and as directed
M & L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A'.
M&L point wiring complete with FRLSH PVC insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including 20mm dia 'Medium grade' PVC concealed conduits and fittings, including cutting chasing in brick wall n.exc 10cm width or girth(excluding ceiling surface), pressed steel concealed terminal switch boxes not less than 1.2mm thick of reqd size factory made duly painted inside and outside with two coats of black bituminous paint over one coat red oxide primer, 3mm thick plastic laminated sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including making good disturbed surfaces with CM(1:4) with treating the surfaces as per existing finishes, One light point controlled by one way switch 5/6 amps. complete all as specified and directed.
All as per item no. 114 but One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps, complete all as specified and directed..
All as per item no. 114 but, One socket out let 5/6 amps point on the independent board, complete all as specified and directed..
All as per item no. 114 but,One Socket out let 5/6 amps point on the Same board boardcomplete all as specified and directed..
All as per item No 114 above but wiring with 4sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed.
S&F switch piano flush type 5/6 amps single pole one way all as specified.
S&F socket 2 in 1, 5 Pin, 5/6 amps, flash type complete all as specified and directed.
S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type 15/16 amps single pole one way complete all as specified and directed.
S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S&F wall mounted slim LED batten 20W(4' feet), with extruded aluminium housing, with polycarbonate diffuser and integrated LED driver complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm and provision of 3 core flexible multistranded copper conductorof size 0.75 Sqmm from ceiling rose to fan all as specified and directed.
Supply and Fixing MCB DB double door, powder coated sheet metal enclosure, 4 way 240 volts grade single pole and neutral with 200 amps rated bus bar,IP 20 protection fixed to wall using nuts & bolts and washer of suitable dia and grouted to wall using suitable gutties complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 amp and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 to 32 amp and current carrying capacity in the MCB DB complete with connection testing and commissioning.
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type B0 using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
M&L sub main wiring concealed type with two run single core cable PVC insulated cable with 4.0 Sq mm(Nominal area) multi stranded copper conductor FRLS cable1100 volts gde earth continuity conductor using PVC insulated cable of standed copper conductorof size 4.0 Sq mm connectedto common earth dolly and drawing into rigid PVC casing-capping of 25 mm dia medium grade size,making good the disturbed surface complete. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
Supply,laying and testing cable XLPE insulated,screened,PVC bedded,galvanizedsteel strip or wire armoured heavy duty electric cable 1100v grade with stranded aluminium conductor of size 16 sq mm 4 core all fixing and connecting accessories such as cable lugs,cable glands,nut,bolts, complete all as specified and as directed.
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm directed by Engineer-in-charge.
Supply and fix Gun metal ,globe Gate Valves with iron wheel head of 25 mm dia bore complete with all accessories all as specified and directed by Engineer-in-charge.
M& L for cutting existing GI pipe alteration or addition of 40/50 mm dia bore for inerstion of reducer Tee complete with all accessories all as specified and directed by Engineer-in-charge.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc.
Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
All as per item No 137 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed.
S&F bell/buzzer push, 5/6 amps, white ivory finish flush type complete all as specified and directed.
S&F call bell ding dong type AC single pole 220 volt surface type complete all as specified and directed.
M & L for lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S&F fan regulator, 5 step(rotary stepped), electronic type, single phase,120/180 V, 400 watt, socket size incl connection complete complete all as specified & directed.
S&f LED recessed mounted light (2'×2'),36 w suitable for indoor space including provision of three core PVC cable of copper conductor of size 23/.0076 and making connection complete all as specified and directed Make :Philips Cat No.RC380B LED 36S - 6500 G5 L60W60PSU OD SG, Havells,Bajaj or equivalent.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc.
Supply and Fixing sheet metal enclosure, 8 way Distribution Boards (DB's) double door,240 volts grade single pole and neutral with 200 amps rated bus bar,IP 20 protection fixed to wall using nuts & bolts and washer of suitable dia and grouted to wall using suitable gutties complete all as specified and as directed.
S&F MCB Triple pole & neutral, 40 amps amp, 415 volts, 'C' series, 10 KA breaking capacity & making connection complete including taking down the old one all as specified and directed by Engr-in-Charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
M/S. JOGINDER KUMAR GOYAL
M/S RELIABLE CONSTRUCTION CO.
M/s Sohini Construction
M/S RATNESH KUMAR SINGH
M/S ASHOK ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .