Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹79,100
Closing Date
22 Sept 2025, 9:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Bengaluru Water Supply And Sewerage Board
Suhas H P
Tender for the Work of Providing/Supplying of Spare Materials to 220KV/66KV/11KV/6.6KV Substations at Harohalli and Tataguni 220KV receiving stations coming Under EE K-O&M-2 Division Harohalli (Emergency and Essential Work)
BWSSB/2023-24/IND0031/CALL-4
BWSSB/2023-24/IND0031/CALL-4
Open
Two Tender Document System(Two Cover)
BWSSB Executive Engineer Kaveri Operation and Maintenance Two
12 documents required · 10 mandatory · 2 optional
Item-by-item commentary on the Purchaser's Technical Specifications demonstrating substantial responsiveness of the goods and services to those specifications or a statement of deviations and exceptions to the provisions of the Technical Specifications.
Past Experiance
The tenderer should be a manufacturer who must have manufactured, tested and supplied equipment(s) similar to the type specified in Schedule Requirements up to 80% of (40% with respect to Micro and Small Enterprises in any one of the last 2 years) the quantity required in any one of the last 3 Years (2 Years for Micro and Small Enterprises) The equipments offered for supply must be of the most recent series models incorporating the latest improvements in design. The models should have been in satisfactory operation for 12months as on date of tender opening
In case of authorized representative/dealer of a manufacturer - The manufacturer furnishes authorization in the prescribed format assuring full guarantee and warranty obligations as per General Conditions of Contract and Special Conditions of Contract. Manufacturers Authorization Form to be provided as per Section XIII of Tender Document.
Tenderer, as authorized representative has supplied, installed and commissioned satisfactorily at least 30% of quantity similar to the type specified in the specified in the price schedule of requirements in any one of the last 3years which must be in satisfactory operation for at least 12 months on the date of tender opening
Details of experience and past performance of the tenderer on equipment offered and on those of similar nature within the past three/five years2 and details of current contracts in hand and other commitments.
GST Certficate
Registration Certificate as Electrical Contractor
The average annual financial turnover of the tenderer should be more than Rs.39,16,000/- (it will be Rs.19,58,000/- with respect to Micro and small enterprises) during the last 3 preceding financial years (last 2 preceding financial year with respect to micro and small enterprises) ending on the relevant financial year
ITR
The tenderer should furnish the information on all past supplies and satisfactory performance for both (a) and (b) above, in proforma under section XII.
The legal status, place of registration and principal place of business of the company or firm or partnership.
A detailed description of the essential technical and performance characteristics of the goods.
A list giving full particulars, including available sources and current prices, of spare parts, special tools, etc., necessary for the proper and continuing functioning of the goods for a period of two years, following commencement of the use of the goods by the Purchaser.
₹500
₹79,100
8 Sept 2025
8 Sept 2025
23 Sept 2025
18 Sept 2025
Phase Plates (Set of 6 per tower)
Number Plates/Circuit Plates
Danger Plates/Caution Plates (1 no. per tower)
Anticlimbing Device GI Barbed wire (12 Mtr/Kg)
Telescopic Ladder aluminium 6 m height (Approved Make)
Hydraulic crimping tool upto 1000 Sq mm (Approved Make)
Line live tester
Rubber hand gloves 15 kV tested
Insulation Tester Digital type (Megger) 2.5 kV - 5 kV (Approved Make)
SF6 gas leak detector (Approved Make)
Multimeter electronic type (Approved Make)
Rubber shoes knee height
Grounding sticks extendable upto 18 ft - 3 nos. of each 6 ft Sticks of 3 phase R, Y, B (3 nos. of 1 set)
Manilla rope 1INCH (One bundle of 100 m)
Safety belts With accessories (Approved Make)
Safety helmet with rachet
Hydraulic Bolt Cutter/Wire Cutter upto Drake ACSR conductor with bits for cuttings (Approved Make)
LT Line Spacer For 4 Wire
Insulated GOS Operating Handle/Rod for Redesigned & Modified GOS
Tubular Telescopic Tree Pruner Comprising of 2 Sticks Weight Less than 3 Kgs Blade Length 16inch, Thickness 1.5 mm Length of the Blade and Rod 6.5 Mtr Circumference of the Rod 120mm Rod Material FRP or Aluminum. Insulation shall be provided if Aluminum material is used for rod.
LDPE Safety Cone with (BWSSB) LogO
C-Type Wedge Connectors Drake to Drake ACSR Conductor
CT Clamp For Single Drake
Drake 4 Hole Paddle ACSR conductor 895A
P.G. Clamps For Drake
Pad Clamps For Drake
SF6 gas filling KIT/adapter
Bamboo Ladder (Hight of 10mtr)
Bamboo Ladder (Hight of 06mtr)
Arc flash suit, 40Kal, 3layer (Approved Make)
Voltage Transformer 220KV Rating, Single phase, oil filled, outdoor type VT with terminal connector suitable for Al. tube/conductor with marshalling box etc., complete as per technical specification. (Approved Make) Voltage Ratio 220 kV/3 / 110 V/3 - 110 V/3 accuracy class 0.2, Insulation Level 460/1050Kv, Creepage GREATER THAN 6125
CURRENT TRANSFORMERS Oil filled Current Transformer 0.2s class with terminal connector suitable for Al. tube/conductor with marshalling box etc., complete as per technical specifications, (Approved Make) 220 kV Class 1200-800-400-300/1-1-1 A plus 2 cores of 1200/1 A
Voltage Transformer 66KV Rating, Single phase, oil filled, outdoor type VT with terminal connector suitable for Al. tube/conductor with marshalling box etc., complete as per technical specification. (Approved Make) Voltage Ratio 66 kV/3 / 110 V/3 - 110 V/3 - 110 V/3
CURRENT TRANSFORMERS Oil filled Current Transformer 0.2s class with terminal connector suitable for Al. tube/conductor with marshalling box etc., complete as per technical specifications, (Approved Make) 66 kV Class CT ratio 400-200 / 1-1-1 A (For Line 1and 2) (II AND III stage Supply)
Lightning (Surge) Arrestor 198 kV Metal Oxide with surge counter Arrestor class Station Medium Duty (SM) - Discharge Class 3 - for Overhead Line, Transformer UG Cable
Lightning (Surge) Arrestor 60 kV Metal Oxide with surge counter Arrestor class Discharge Class 3 (Station Medium Duty (SM) - for Transformer & UG Cable
Solid Core Bus Post Insulator 220 kV
Solid Core Bus Post Insulator 66 kV
a 220 kV, 120 kN Tension Type Porcelain Long Rod Insulators with sectional length - 2175/2320 mm
a 66 kV, 120 kN Tension Type Porcelain Long Rod Insulators with sectional length - 725 mm
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
220KV Requirments DTP.docx
Tender Document • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .