Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹38.2 CrAccepted-AOC PLOT NO F AND G RAKBA DARAKHERA PROFESSOR COLONY NAGARPARISAD THANESAR KURUKSHETRA 136118 | KURUKSHETRA | KURUKSHETRA | HARYANA | 136118 | 1 | Accepted-AOC L1 | |
| 2 | 2₹45.1 Cr+₹6.9 Cr (18.1%)Rejected-Finance | 2 | Rejected-Finance L2 | |
| 3 | 3₹46.9 Cr+₹8.7 Cr (22.7%)Rejected-Finance D 40 OKHLA PHASE 1 NEW DELHI 110 020 | 3 | Rejected-Finance L3 | |
| 4 | 4₹48.4 Cr+₹10.2 Cr (26.8%)Rejected-Finance 86 SECTOR 07 URBAN ESTATE KURUKSHETRA | 4 | Rejected-Finance L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Disqualified |
Tender Value
₹40.7 Cr
EMD Value
₹89.1 L
Closing Date
29 Apr 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Rahul Poonia
Municipal Corporation Panipat
Construction of Indoor Stadium in MC Panipat under CM Announcement
2024_HRY_368012_1
2024AC300FE6 8997 4040 A27B 88FF75CB6109286ULB
Open Tender
Civil Works
Works
365 days
Panipat
2 documents required · 2 mandatory
₹20,000
₹89.1 L
Yes
Municipal Corporation Panipat
16 Aug 2024
13 Mar 2024
30 Apr 2024
13 Mar 2024
29 Apr 2024
13 Mar 2024
21 Mar 2024
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and installation of tested Vetrotech Saint-Gobain VDS® fully glazed fire-rated Latched double leaf door system with 120 minutes of integrity and radiation control (EW 120) with symmetrical (bi-directional) fire protection through a VDS Certified Installer. The frames shall be made of imported cold rolled profiles. The door frames are cold rolled from 1.5 mm steel sheet to form a profile of 50 mm x 50 mm on all sides. The door shutter would have the top rail, side rail and bottom rail dimensions of 50 mm x 50 mm. The overall door opening shall be as per tested evidence and tested as per EN 1634-1 in an accredited international laboratory. The glass shall be CONTRAFLAM LITE (14mm) clear, non-wired, toughened, interlayered, 120 minutes fire-rated glass for integrity and radiation control (EW 120) and insulation (I 20) with a light transmission of 86% and a sound reduction of 38 dB and manufactured in UL and TUV audited facility and including UL-EU Certification (File number R38101) and compliant to class 1(B)1 category of Impact Resistance as per EN 12600. The glass shall be tested for 5000 hours of UV resistance as per EN ISO 12543-4. The glass shall be EPD (Environmental Production Declaration) verified in accordance to EN 15804 and ISO 14025 in which its life cycle assessment is performed considering Cradle to Gate system boundaries. The glass must produce a recycled content declaration committing to a pre-consumer cullet of up to 11% and post-consumer cullet less than 1%. The glass shall provide bi-directional (symmetrical) fire protection. The shutters should be fixed to the frame using weld-on hinges of dimensions 179mm X 20mm. The profiles shall have grooves to incorporate fire-resistant gaskets. The doors shall incorporate drop down seal at the bottom. The glass should be held in its place with the help of 1.5 mm cold rolled steel beading and Kerafix 2000 ceramic tape with cross section of 4 x 15 mm as per the test evidence. The beading shall be clipped on using stainless steel self-tapping screws fixed at a distance of 70 mm from the edges and 150 mm c/c henceforth. The glass panes are to be supported on non-combustible 5 mm thick calcium silicate setting blocks. The door should be fitted with panic bar (Dorma PHA 2000) and door closer of Dorma (TS 73V, TS 83V, TS93V), Geze (TS 2000NV) or equivalent. The inactive leaf should be fixed to the frame using a tower bolt at meeting edge at top or as per the tested evidence. The doors shall be manufactured in a TUV audited facility. | 15.12 | Sqm | - | - |
| 2 | BUTTERFLY VALVE WITH ON/OFF TYPE MOTORIZED ACTUATOR Single phase 220V with limit switches, C I body and PN 1.6 pressure rating SS Disc and shaft of Feedback, BMS Compatible for overhead tank filling as specified duly insulated of following sizes as per specification and drawings. Cost should include necessary control wire (minimum size 1.5 sq.mm) for 32 mm dia | 1 | Each | - | - |
| 3 | Providing, fixing, joints and testing in position the following UPVC Pipe confirming to IS:4985 of 6kg /sqcm for garden irrigation system cut to required length pipe to be laid below level in trenches up to required depth, including excavation in all kind of soil (hard rock) dewatering, refilling, watering, ramming and removing the surplus excavated material and putting 100 m sand all-around and making good the same. for 63 mm dia | 160 | Metre | - | - |
| 4 | Providing, fixing, joints and testing in position the following UPVC Pipe confirming to IS:4985 of 6kg /sqcm for garden irrigation system cut to required length pipe to be laid below level in trenches up to required depth, including excavation in all kind of soil (hard rock) dewatering, refilling, watering, ramming and removing the surplus excavated material and putting 100 m sand all-around and making good the same. 50 mm dia | 20 | Metre | - | - |
| 5 | Providing, fixing, joints and testing in position the following UPVC Pipe confirming to IS:4985 of 6kg /sqcm for garden irrigation system cut to required length pipe to be laid below level in trenches up to required depth, including excavation in all kind of soil (hard rock) dewatering, refilling, watering, ramming and removing the surplus excavated material and putting 100 m sand all-around and making good the same. 40 mm outer dia | 20 | Metre | - | - |
| 6 | Providing and fixing in position 25 mm dia lawn hydrants consisting of 25 mm dia Ball valve, GI nipple and threaded hose receiver complete as required. | 10 | Each | - | - |
| 7 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design: | 150 | Rmt. | - | - |
| 8 | Constructing Silt trap of size 1000mm x 2000mm x 1000mm effective deepth in brick masonry with bricks of class designation 7.5 in cement mortar 1:6 (1 cement: 6 coarse sand) including necessary excavation and foundation concrete 150mm thick in 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate of 40mm nominal size), inside plaster 12mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating coat of neat cement, C.C. floor, RCC slab in mix 1:2:4 and RCC baffle wall including reinforcement, centering and shuttering etc. and SFRC manhole cover and frame 610 x 455 mm heavy duty HD 10 conforming to IS: 12592 complete in all respects as per drawing and direction of Engineer in charge . | 1 | Each | - | - |
| 9 | Constructing Brick masonry percolation pit 3m dia and 5m deep with bricks of class designation 7.5 in cement mortar 1:6, base concrete 1:3:6 below the brick wall, including cost of necessary excavation in any type of soil, back filling as required in 20cm thick layers, dewatering if any, shuttering and shoring and disposal of surplus excavated material within the plot. 2 nos. 300mm dia borings to a depth of 50 metre (to be measured from the bottom of the percolation pit), provisioning and fixing 160 O.D. PVC pipes, tested to 6kg/sqcm, in each bore and upto the height of 300mm above the RCC top slab. The PVC pipe shall be slotted except 3.0 metres at the top and 3.0 metres below from the bottom of the percolation pit, which shall be blind. Top of the PVC pipe shall be covered with PVC Socket and plug. Each bore around the PVC pipe shall be filled with pea gravels. The percolation pit shall be filled with river stone/pebbles as per drawing and direction of Engineer in charge. | 1 | Each | - | - |
| 10 | Providing and fixing in position CI grating over surface drain complete as required for the following sizes :- for 30 cm wide drain sleeve size 75cm x 60cm and 7cm thick | 90 | Metre | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_443751.xls
BOQ • 0.79 MB
141853293.pdf
Tender Documents • 3.84 MB
141853295.html
Tender Documents • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .