Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC PLOT NO 8 5179 SAILASHREE VIHAR CHANDRASEKHARPUR BHUBANESWAR DIST KHURDA ODISHA 751 021 | KHORDHA | ODISHA | 751021 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹8.7 L+₹20,558.10 (2.41%)Rejected-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L2 | Rejected-Finance Being L2 bidder | |
| 3 | L3₹9.0 L+₹46,023.60 (5.40%)Rejected-Finance INDEX NO D 381 HQ CE EC KOLKATA CAMP INS CHILKA PO NB CHILKA DIST KHORDHA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Being L3 bidder | |
| 4 | L4₹9.0 L+₹48,081.60 (5.64%)Rejected-Finance 309 VINAYAK TOWER CUTTACK PURI ROAD BHUBANESWAR 751 006 | KHORDHA | ODISHA | 751006 | L4 | Rejected-Finance Being L4 bidder | |
| 5 | L5₹9.7 L+₹1.2 L (13.8%)Rejected-Finance | L5 | Rejected-Finance Being L5 bidder |
| Sl No | Description | Qty | Unit | Shree Mahavir Associates L4 | M/S SRI SAI SRINIVASA CONSTRUCTIONS L3 | SWAIN ENGINEARING L7 | PABITRA MOHAN PARIDA L6 | Atish Builders LLP L8 | M/S SOMANATH ENTERPRISES L2 | SMART ENERGY SOLUTIONS L1 | ODRA NIRMAN L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation or taking up / down electrical cables / pipe. and getting out in soft/loose soil concrete complete all as specified and directed. | 27 | Cum | 233 ₹6,291 Lowest | 249 ₹6,723 | 300 ₹8,100 | 300 ₹8,100 | 360 ₹9,720 | 320 ₹8,640 | 280 ₹7,560 | 320 ₹8,640 |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed. | 17.51 | Cum | 5 ₹87.55 Lowest | 95 ₹1,663.45 | 60 ₹1,050.6 | 100 ₹1,751 | 108 ₹1,891.08 | 100 ₹1,751 | 60 ₹1,050.6 | 100 ₹1,751 |
| 3.00 | Removing excavated spoil to a distance n.exc. 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. | 9.49 | Cum | 55 ₹521.95 Lowest | 125 ₹1,186.25 | 60 ₹569.4 | 100 ₹949 | 108 ₹1,024.92 | 150 ₹1,423.5 | 120 ₹1,138.8 | 240 ₹2,277.6 |
| 4.00 | M&L for sand cushion for under ground cable protection and consolidated and compacted with clean dry river sand complete all as specified and directed. Note- Punned thickness will be measured at the time of measurement and payment. | 8 | Cum | 777 ₹6,216 | 880 ₹7,040 | 1,200 ₹9,600 | 1,100 ₹8,800 | 1,800 ₹14,400 | 1,250 ₹10,000 | 700 ₹5,600 Lowest | 1,500 ₹12,000 |
| 5.00 | M&L bricks fly ash bricks locally available of size 230mm x 115mm x 75mm best quality laid in trenches over sand cushioning for cable protection complete all as specified and directed. | 750 | Each | 8 ₹6,000 | 5.5 ₹4,125 | 8 ₹6,000 | 6 ₹4,500 | 9 ₹6,750 | 10 ₹7,500 | 6 ₹4,500 | 5 ₹3,750 Lowest |
| 6.00 | Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq mm 3.5 core, including taking down old UNSV cable complete all as specified and directed. | 100 | RM | 1,233 ₹1,23,300 | 570 ₹57,000 Lowest | 580 ₹58,000 | 670 ₹67,000 | 1,225 ₹1,22,500 | 650 ₹65,000 | 690 ₹69,000 | 630 ₹63,000 |
| 7.00 | Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq mm 3.5 core, including taking down old UNSV cable complete all as specified and directed. | 110 | RM | 321 ₹35,310 | 205 ₹22,550 Lowest | 320 ₹35,200 | 270 ₹29,700 | 603 ₹66,330 | 250 ₹27,500 | 290 ₹31,900 | 280 ₹30,800 |
| 8.00 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 core nominal cross section in service connections complete all as specified and directed. | 100 | RM | 123 ₹12,300 | 195 ₹19,500 | 160 ₹16,000 | 140 ₹14,000 | 270 ₹27,000 | 100 ₹10,000 Lowest | 130 ₹13,000 | 193 ₹19,300 |
| 9.00 | Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq mm 4 core, including taking down old UNSV cable complete all as specified and directed. | 120 | RM | 234 ₹28,080 | 250 ₹30,000 | 235 ₹28,200 | 230 ₹27,600 | 360 ₹43,200 | 200 ₹24,000 Lowest | 250 ₹30,000 | 230 ₹27,600 |
| 10.00 | S&F in replacement bracket for street light made out of 1.5 Mtr long, 40 mm bore GI tubing, medium grade bent to required angle/ shape with and including necessary clamps, nuts, bolts, & washers of suitable size, including taking down old UNSV bracket complete all as specified and directed . | 20 | Each | 344 ₹6,880 Lowest | 500 ₹10,000 | 670 ₹13,400 | 900 ₹18,000 | 630 ₹12,600 | 650 ₹13,000 | 550 ₹11,000 | 650 ₹13,000 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
18 Oct 2025, 6:00 pmClosed
Shri Himanshu IDSE EE
GE (I)(CG) Bhubaneswar, Military Engineer Services, Near School Integral Education, Campus-2, Coast Guard Complex, Pallaspalli, Bhubaneswar-751 020 (Odisha)
REPAIR AND MAINTENANCE OF BOLLARD LIGHT FITTING STREET LIGHT SOLAR STREET LIGHTS BOREWELL PUMP MOTORS UG CABLES AND CONNECTED WORKS AT CGRA COMPLEX AND OTM AT ICGS GOPALPUR
2025_MES_728471_3
8593/BBSR/04/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GOPALPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (I) (CG) Bhubaneswar
₹24,000
Yes
1 Dec 2025
29 Sept 2025
20 Oct 2025
29 Sept 2025
18 Oct 2025
6 Oct 2025
Amount
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation or taking up / down electrical cables / pipe. and getting out in soft/loose soil concrete complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated spoil to a distance n.exc. 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for sand cushion for under ground cable protection and consolidated and compacted with clean dry river sand complete all as specified and directed. Note- Punned thickness will be measured at the time of measurement and payment.
M&L bricks fly ash bricks locally available of size 230mm x 115mm x 75mm best quality laid in trenches over sand cushioning for cable protection complete all as specified and directed.
Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq mm 3.5 core, including taking down old UNSV cable complete all as specified and directed.
Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq mm 3.5 core, including taking down old UNSV cable complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 core nominal cross section in service connections complete all as specified and directed.
Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq mm 4 core, including taking down old UNSV cable complete all as specified and directed.
S&F in replacement bracket for street light made out of 1.5 Mtr long, 40 mm bore GI tubing, medium grade bent to required angle/ shape with and including necessary clamps, nuts, bolts, & washers of suitable size, including taking down old UNSV bracket complete all as specified and directed .
Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete complete all as specified and directed.
Supply & fixing in repair Building security light fitting,new compact designed IP 66, Aluminium PDC housing with toughen glass cover high power LED street light/Building Security light of capacity 25 watt.including provn of necessary connection complete all as specified and directed. (Make/ Model:- Crompton(ASTRA NEO), Cat No . LSTS-25-CDL-M or equivalent make of Phillips/Havells/ Bajaj/Wipro)
S&F, PVC insulated 3 core 1.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting, testing and commissioning complete all as specified and directed.
Supply and fixing in replacement of SMC junction box of size 270mm x 225 mm x 135 mm hinged type door 4 Nos terminal with 6-20 Amp MCB fixing on pole with necessary fixing arrangement such as jointing material, nuts, bolts, washers and clamps etc including taking down old UNSV complete all as specified and directed.
Labour for Repair/ maintenance of street lights/ yard lights/ high mast fitting/Bollard /garden luminaire of any size/ type fixed on poles/bldgs/tower including taking down as required at a height exc. 8m from the ground level including dismantling all the defective components, checking its serviceability circuit board, driver units and carried out necessary minor repairs/soldering of worn out circuits /connections, replacement of unserviceable parts and refixing the same after repair including connecting and testing the same, replacing the fused lamps, burnt out wiring, ballast and igniter, capacitor and reassembling and fixing the fitting to original position complete, testing and commissioningcomplete all as specified and directed . Replacement of fused wire is deemed to be included and other items will be measured and paid separately under relevant items, however securing wiring/ tapeing/refixing is deemed to be included in Job. Note: (a) Irrespective of fittings/ components replaced, the measurement shall be made for one pole as one unit. (b) Attending through necessary ladder arrangement on vehicle or ladders etc shall be arranged by the contractor. (c) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor. (d) Contractor is completely responsible for the safety of manpower employed by him.
Supply only the following for fixing the defective componets under relevant Item No 15
(a) Driver unit suitable for LED street light fittings of 45/60 watts
(b) MCPCB unit suitable for LED street light fittings of 45/60 watts
(c) Surge protection suitable for LED street light fittings of 45/60 watts
(d) Driver unit suitable for LED bollard light fittings of 10/12 watts
(e) MCPCB unit suitable for LED bollard light fittings of 10/12 watts
(f) Surge protection suitable for LED bollard light fittings of 10/12 watts
Labour for Repair/maintainace of LT cable faults by disconnecting and taking out old existing LT cable of any sizes, in any position from trench/duct/panel and removing/excavating the outer surface of cable, examining cable and joints for defects and ascertaining suitability of cable for reuse, meggering, cutting out the defective portion of cable/joint, including taking out old serviceble PCC cable covers/Bricks or GI pipe of any type/size and relaying the cable with old serviceable bricks/PCC cable covers after repair/replacement of cable / jointing kit of any make or size of existing then make good the excavated area by returning/filling the same complete all as specified & directed. Note: (a) Using of new GI pipe or new jointing kit will be paid separately in concerned items (b) Excavation, refilling and sand/cable covers as used will be paid separately. (c) Irrespective of nature of complaint fault identification and necessary minor accessories as tape/lugs/nuts bolts/testing through test lamp or meggering for any fault identification and securing cables or connected switch gear after defect rectification is deemed to be included in the scope. (d) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor. (e) The fuse of call/breakdown and defect identification to be attended immediately within 2 hrs and process for proper defect identification should be completed in continuation alongwith any further workmen or equipment required as defect rectification being essential service in nature and the cost is deemed to be included in scope of work and also as directed. (f) Contractor is completely responsible for the safety of manpower employed by him.(g) The contactor need to arrange necessary skilled manpower immediately to restore the essential electrical services.
Dismantling and taking out old un-serviceable Non-integral light fittings from 16 mtr High mast tower with checking its connection and unserviceable parts ,such as Drivers,LED lamps ,LED Fittings etc and replace the same and refitting in its position including servicing the double drum winch and greasing the 5 mm dia steel wire rope, wheels,operating handles with all parts and equipments of existing High mast Tower ,fitting ,Allignment upto length, testing complete in all respect after the high mast tower mounted all as specified and directed. Note: The Lights fittings to be replaced shall be measured seperately under this schedule of item.
S&F in replacement MCCB 4 pole with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 63 Amps complete all as specified and directed.
Supply and fixing in replacement of MCCB 4 pole , 100 amp rating of 16 KA Fixed type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed.
Supply and fixing in replacement of MCCB 4 pole , 160 amp rating of 36 KA Fixed type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed.
M & L for cable fault finding of any size at any location complete with rectification duly joined by suitable jointing kit above 25 Sqmm cable complete all as specified and directed.
S&F in replacement of on load change over switch with enclosure 3 phase 415 volt 50 Hz 160Amp to be fixed in existing panel complete all as specified and directed.
S&F in replacement of on load change over switch with enclosure 3 phase 415 volt 50 Hz 63 Amp to be fixed in existing panel complete all as specified and directed.
M&L for Cutting Bituminous road in,making good with facing where required and pointing exc.30 cm. but not exc.1.0 mtr. girth to ends oredge steps, cills, sunshades, shelves, lintels, etc.and cutting chases for concealed water tubing or concealed conduit wiring,laying of cables and making good with old shape and size complete all as specified and directed.
Supply and fixing of neon light (RYB) complete on existing LT panel board including dismantling and taking out of old items complete with connected wiring for Phase indication complete all as specified and directed.
Supply and fixing of Amperemeter digital (0-100)Amp, along with CT's complete on existing LT panel board including dismantling and taking out of old items complete all as specified and directed.
Supply and fixing Voltmeter digital type with of (0-440) Volt on existing LT panel board including dismantling and taking out itms complete with connected wiring for Phase indication complete all as specified and directed.
S&F in replacement of air break gang operated switches vertical/horizontal type such as repair/ replacement of broken/worn out components & insulators and greasing the moveble parts ( Male/female parts) for smoth functioning complete all as specified and directed.
S&F in replacrment of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11KV greasing the moveble parts ( Male female parts) for smoth functioning complete all as spcified and directed.
Supply and fixing in replacement Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
Supply, heating and topping up transformer insulating oil EHV grade having dielectric strength not less than 60 KV (R.M.S) at 2.5 mm gap high viscosity confirming to IS – 335 of 1983 complete for replacement of unserviceable transformer oil or for toping up complete all as specified and directed.
M & L for painting of two pole structure (11 meter height) with aluminium paint after removing old paint from pole & other steel section such as angle, bracket & support clamps etc and inclusive of one over coart and one finishing coat of aluminium paint complete all as specified and directed.
M & L for painting of 9 metre height Street light pole with aluminium paint after removing old paint from steel pole & other steel section such as angle, bracket & support clamps etc and inclusive of one over coart and one finishing coat of aluminium paint complete with numbering of pole complete all as specified and directed.
Supply & fixing in replacement of breather Assembly for upto 250 KVA Transformer complete all as specified and directed. Make : MB Supplier/Pooja industries/Goyal electric works.
S & F in replacement of .LT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for upto 250 KVA Transformer complete all as specified and directed.
Supply & fixing in replacement of breather Assembly for upto 200 KVA Transformer complete all as specified and directed. Make : MB Supplier/Pooja industries/Goyal electric works.
S & F in replacement of .LT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for upto 200 KVA Transformer complete all as specified and directed.
M&L for Filtration and Dehydration of transformer oil of Transformers at different location of CGRA/CGAE with filtration cum dehydration machine to achieve desired level of di electric strength of transformer oil including testing complete all as specified and directed. Note- The quoted rate shall deem to incl for the cost of centrifuging the transformer oil by means of electrical operated centrifuging machine . (ii) The contrator shall test the di electric strength of oil of each transformer before dehydration & filtration and after completion of dehydration and filtration process he shall submit record of the same. Each sample of oil shall be tested with a transformer oil test machine at site in presence of concerned JE/ Engr- in- Charge. The contractor will have to arrange correctly calibrated Transformer Oil Test machine. for this purpose. (iii) The dielectric strength should not be less than 45 KV.
Supply and fixing in replacement MS tubing medium grade of 50 mm dia with all fitting including welding and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in replacement CI Foot Valve suitable for 50 mm dia Tubing conforming to IS 4038 complete all as specified and directed.
Supply and fixing in replacement of brass gun metal gate valve with iron wheel head screwed both ends for iron pipes including taking out old unserviceable valves for 50 mm dia pipe complete all as specified and directed.
M&L for Cleaning ,servicing ,painting ,writing SM.MES No including minor repair work if required and greasing of all moving parts i.e pump impeller , stainless steel shaft, bearing etc for smooth running and replacement of packing gaskets, shaft sleeve, gland packing, neck ringnut bolts and washers etc, with necessary oiling and greassing of pump up to 10 HP complete all as specified and directed.
Dismantling and taking down of motor from pump after disconnection of mechanical tyre coupling and unbolting from foundation base plate,discconecting of electric connection from terminal loading/unloading the motor to vehicle and transportation of the motor to workshop, cutting the burnt winding and clean the rotor & stator with CTC or other cleaning matterial and rewinding of stator winding with supper enameled copper wire as per existing the size/gauge wire and turn of the previous winding, insulating the leads with insulating tubes and varnishing the stator with good quality of insulating varnish . Afterward heating the stator in heat chamber for continous 2 days for better insulation resistance reassembling the stator & rotor carefully after replacement of worn out bearings, transportation of motor from workshop to its original location, unloading the motor and placing it on base frame, connection of motor with pump with tyre coupling and fixing to the base frame after checking up the alignment, testing of motor with megger for checking of insulation resistances, electric connection of motor to the control panel, testing on load for continous running for 3 hrs of capacity up to 10 HP Induction motor complete all as specified and directed.
M&L for repair, cleaning and servicing of automatic star delta starter of capacity 10 HP fixed in existing LT panel including tightening of all loose coonection and replacement of minor defective parts such as cable lugs, nut bolts PVC copper connection wire etc to make the starter serviceable complete all as specified and directed. (Major defective parts will be measured and paid seperetely under relevent item as supply only)
Cleaning and removing all scales and deposited materials in under ground water sump of capacity up to 2.5 lakhs ltr by drain out the ludge/wate at bottom of the tank by mannualy or using non cloging pump sets and applying bleaching powder , brushes for removing deposited materials and removal the same from sump and deposited the same where as directed (not more than 50 mtr) , including cleaning the sourrounding area of under ground sump complete all as specified and directed. Note :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud utside the premises shall be deemed to include in the above item rate.
Cleaning and removing all scales and deposited materials in over head tank 50000 liters capacity by applying bleaching powder , brushes for removing deposited materials, including jungle cleaning to sourrounding area including draining out existing water complete all as specified and directed. Note :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud utside the premises shall be deemed to include in the above item rate.
M&L in replacement of Ball brass valves, high pressure, with polythene float and flynut complete, screwed for 50 mm dia iron pipe or brass ferrule and fixed complete all as specified and directed.
Disconnection of electric connection of 05 HP submercible pump from panel and remove GI pipe from bore well and taking out submersible pump and motor from bore well carefully & check the motor and carry the motor to work shop for repair. Then repair the motor including winding of the motor, Motor brush and key and clamp & nut and bolts etc. anf fixing 5 HP submersible pump and motor after repair inside the bore will carefully and fixing GI pipe 50 mm dia in same bore well and connect electric supply to motor and function satisfactory complete all as specified and directed.
S&F rubber coupling F50 size to the pump motor shafts at pump house including connected nut bolts etc complete all as specified and directed.
Dismantling and taking down old un-serviceable all in one solar light fittings of any capacity and any make from existing pole and checking its connection and unserviceable parts ,such as lithium ferro phosphate battery, Charge controller, solar plate, Driver,LED and refitting after changing defective parts in its position including painting of solar light fitting and pole on which light is fitted with aluminium paint after removing old paint from pole & other steel section such as angle, bracket & support clamps etc and inclusive of one over coart and one finishing coat of aluminium paint , testing complete in all respect after the refixing complete all as specified and directed. Note: The lithium ferro phosphate battery, Charge controller, solar plate, Driver,LED to be replaced shall be measured seperately under this schedule of item.
Supply only the following for fixing the defective componets under relevant Item No 51
(a) Driver unit suitable for solar all in one LED street light fittings of 30/40 watts
(b) Lithium ferro phosphate battery 12.8V , 36 Ah suitable for solar all in one LED street light fittings of 30/40 watts
(c) Charge controller, 12V, 6A suitable for solar all in one LED street light fittings of 30/40 watts
(d) LED Panel ( 140- 150 lumens / W) suitable for solar all in one LED street light fittings of 30/40 watts
Disconnecting and removing existing unserviceable battery and S & F maintenance free battery 12 V 100AH with minium 2 years warrenty complete all as specified and directed. ( Make : Exide/Amco/ Amaron/Luminus)
Disconnecting and removing existing unserviceable battery and S & F maintenance free battery 12 V 90AH with minium 2 years warrenty complete all as specified and directed. ( Make : Exide/Amco/ Amron/Luminus)
M & L for replacement of battery lead set of 2 Nos 1.5m long copper lead of 35 Sqmm size including GM Materials at one end and copper lug at other and complete all as specified and directed.
M&L for repair to RO Water purifier of capacity 40 litre/hour fully Automatic installed at OTM Matikhalo including replacement of Filters and other defective membrane parts and making good to function properly complete all as specified and directed.
Supply & Replacement of RO water purifier circulating motor suitable for capacity 40 litre/hour / make including taking down complete all as specified and directed.
Supply & replacement of RO water purifier connection pipe of size 1/4'' include taking down complete all as specified and directed.
Material and labour for carrying out Maintenance/Servcing for the following DG set including cleaning of air filter using pressure air, O ring, Gaskets, screws etc, checking of engine oil level & draining out old engine oil from oil chamber and removing deposited material including applying grease, cleaning with CRC of all moving parts and draining out water from radiator assembly, checking of coolant level in radiator and refill new after mixing with coolant, including tightening all inlet and outlet connections and replacing minor items such as hose clamp, screws, washers etc. Check Air piping and vibration damper, filling with new coolant, Inspection of alternator and starter, Checking of V-belt condition & tension(Adjust/ replaced if required), Battery health check up and lead connection including top up of distilled water, cleaning of exhaust silencer, checking of filter kit such as fuel filter, Lub oil filter air filter etc and replacement of parts as required,lubricate ball joints of the throttle linkage of Hyd Governor and change of fuel tank breather complete all as specified and directed. Note : (i) The scope includes attending service/ complaints to DG sets after initial maintenance/service/ for a period of six months .. : (iii). Spare/parts required to be replaced as and when required shall be measured and paid for separately. (iv). The check will be carried out by authorised technician from DG set manufacturer complete (V) The scope includes provision of authorised technician for any functional check/test required as and called upon by department .
(a) 40 KVA DG Set (at OTM Matikhalo)
Supply and fixing in replacement Lub Oil Filter for DG sets of following capacity complete all as specified and directed.
(a) 40 KVA DG Set (at OTM Matikhalo)
Supply and fixing in replacement Diesel Filter for DG sets of following capacity complete all as specified and directed.
(a) 40 KVA DG Set (at OTM Matikhalo)
Supply and fixing in replacement Air Filter (Outer & Inner) for DG sets of following capacity complete all as specified and directed.
(a) 40 KVA DG Set (at OTM Matikhalo)
Material and labour for changing/topping up of engine oil 15W 40 type for various type/capacity DG sets including removing of old burnt engine oil from DG sets complete all as specified and directed. Make:- Servo/BP/HP/Valoline
Supply and topping up antifreezing, inhabitor corrison (coolant) liquid for DG sets of various capacity complete all as specified and directed. Make:- Servo/BP/HP/Valoline/Veedol.
Supply and fixing in replacement of fan belt for DG set of capacity 40 KVA complete all as specified and directed.
Material and labour for carrying out Maintenance/Servcing for the following DG set including cleaning of air filter using pressure air, O ring, Gaskets, screws etc, checking of engine oil level & draining out old engine oil from oil chamber and removing deposited material including applying grease, cleaning with CRC of all moving parts and draining out water from radiator assembly, checking of coolant level in radiator and refill new after mixing with coolant, including tightening all inlet and outlet connections and replacing minor items such as hose clamp, screws, washers etc. Check Air piping and vibration damper, filling with new coolant, Inspection of alternator and starter, Checking of V-belt condition & tension(Adjust/ replaced if required), Battery health check up and lead connection including top up of distilled water, cleaning of exhaust silencer, checking of filter kit such as fuel filter, Lub oil filter air filter etc and replacement of parts as required,lubricate ball joints of the throttle linkage of Hyd Governor and change of fuel tank breather complete all as specified and directed. Note : (i) The scope includes attending service/ complaints to DG sets after initial maintenance/service/ for a period of six months (iii). Spare/parts required to be replaced as and when required shall be measured and paid for separately.(iv). The check will be carried out by authorised technician from DG set manufacturer complete (V) The scope includes provision of authorised technician for any functional check/test required as and called upon by department .
(a) 62.5 KVA DG Set (at CGRA Kaliabali)
Supply and fixing in replacement Lub Oil Filter for DG sets of following capacity complete all as specified and directed.
(a) 62.5 KVA DG Set (at CGRA Kaliabali)
Supply and fixing in replacement Diesel Filter for DG sets of following capacity complete all as specified and directed.
(a) 62.5 KVA DG Set (at CGRA Kaliabali)
Supply and fixing in replacement Air Filter (Outer & Inner) for DG sets of following capacity complete all as specified and directed.
(a) 62.5 KVA DG Set (at CGRA Kaliabali)
Supply and fixing in replacement of fan belt for DG set of capacity 62.5 KVA complete all as specified and directed.
M/S SOMANATH ENTERPRISES (BID ID -3454646)
M/S SRI SAI SRINIVASA CONSTRUCTIONS (BID ID -3448287)
Shree Mahavir Associates (BID ID -3447008)
ODRA NIRMAN (BID ID -3448500)
PABITRA MOHAN PARIDA (BID ID -3453467)
SWAIN ENGINEARING (BID ID -3448358)
Atish Builders LLP (BID ID -3448374)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
TENDER.pdf
Tender Documents • 1.28 MB
BOQ_820878.xls
BOQ • 2.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .