| 1 | L1₹30.5 LAccepted-AOC | L1 | Accepted-AOC L Accepted | |
| 2 | L2₹30.6 L+₹5,851 (0.19%)Rejected-Finance | L2 | Rejected-Finance Other than L1 after deducting Sch of Credit Rs 78666.00 | |
| 3 | L3₹31.7 L+₹1.2 L (3.95%)Rejected-Finance 16 PRATAP NAGAR CHARBHUJA RAWATBHATA RAJASTHAN 323307 | RAWATBHATA | CHITTORGARH | RAJASTHAN | 323307 | L3 | Rejected-Finance Other than L1 after deducting Sch of Credit Rs 78666.00 | |
| 4 | L4₹31.9 L+₹1.4 L (4.55%)Rejected-Finance | L4 | Rejected-Finance Other than L1 after deducting Sch of Credit Rs 78666.00 | |
| 5 | L5₹36.8 L+₹6.3 L (20.6%)Rejected-Finance | L5 | Rejected-Finance Other than L1 after deducting Sch of Credit Rs 78666.00 |
Tender Value
₹31.5 L
EMD Value
₹63,000
Closing Date
2 Mar 2022, 6:00 pmClosed
GE NORTH AKHNOOR
GE NORTH AKHNOOR CO 56 APO
SPECIAL REPAIR TO BLDG NO TR1 TR2 TR3 TR4 TR5 TR8 AND TR9 TYPE A AT AKHNOOR UNDER GE NORTH AKHNOOR
2022_MES_505320_1
GE(N)/AKH-68/2021-22
Open Tender
Civil Works
Item Rate
180 days
AKHNOOR
CLASS D CAT a i b i
8 documents required · 8 mandatory
₹500
Yes
GE NORTH AKHNOOR
₹63,000
Yes
6 Apr 2022
2 Feb 2022
4 Mar 2022
2 Feb 2022
2 Mar 2022
16 Feb 2022
Amount
M&L for Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in subbase of floor, path/hard standing etc finished even and rough to receive topping layer including demolition of existing cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness specifically (below or above ground level) complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 30mm thickness M-35 grade with grey cement and pigment over a layer and including 25mm thick sand cushioning complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping, benching, weathering slightly rounded or chamferred angles and including necessary form work complete all as directed
Demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed by Engineer -in-Charge
Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and as directed by Engineer -in-Charge
All as per Srl item No. 5 here-in-before, but except bricks.
Rendering 10 mm thick in cement and sand mortar 1:6 on other than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth (without using extra cement) including taking down existing cement plaster complete all as specified and as directed by Engineer-in-Charge.
Rendering 15 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface fair and even (without using extra cement) including taking down existing cement plaster complete all as specified and as directed by Engineer-in-Charge.
M&L for Preparation of new treated surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
Providing and applying wall care putty of 1mm thickness over plastered surface of walls to prepare the surface even and smooth complete all as specified and as directed by Engineer-in-Charge.
M&L for Preparation of new treated surfaces of walls and applying two coats of oil bound distemper primer complete all as specified and directed.
Demolition of cement concrete in grond floors (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
25mm thick plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including finishing surface of concrete topping even and rough as in levelling course complete all as directed
M&L for 75 mm thick 75 cm wide PCC type C-1 1:3:6 (using 20mm graded stone aggregate) as in plinth protection laid in bays complete including finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge. Note :- The rate quoted shall be deemed to include for use and waste of form work / screed strips and to divide the area in panels including hardcore.
M&L for machine cut kota stone slab flooring 20-25mm thick as in flooring jointed with grey cement slurry mixed with pigment to match the shade or the slab including rubbing and polishing complete including 20mm thick screed bed in CM 1:4 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge.
Ditto all as per item No 15 here-in-before but in skirting/dado incl 10mm thick CM 1:4 complete.
20 mm thick makrana white marble as in border/cooking platform etc, bedded and jointed in cement mortar 1:6 of 20mm thick screed including pointing in white cement 1:2 using marble dust including cutting and polishing complete all as specified and as directed by Engineer-in-Charge.
Dismantling of AC/CGI/Galvalume sheets corrugated or semi-corrugated in roof covering including ridges, hips, valleys and flashings etc complete all as specified and as directed by Engineer-in-Charge.
S&F structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality B complete all as specified.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
All as per item No 20 here-in-before but plain sheets
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each and removing from site complete all as specified.
All as per Srl item No. 22 here-in-before, but area exceeding 1.5 sqm and not exceeding 4.00 sqm each
Pressed steel frame for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one shop coat of priming complete all as specified and as directed by Engineer-in-Charge.
PCC 1:3:6 type C-0 using 12.5 mm graded stone aggregate as in filling of pressed steel frame complete all as specified and as directed by Engineer-in-Charge.
PCC 1:3:6 type C-1 using 20mm graded stone aggregate for hold fast blocks, including necessary form work for rough finished surfaces etc complete all as specified and as directed by Engineer-in-Charge.
35mm thick, IInd class hard wood plain, framed, panelled factory made shutters (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified.
35 mm thick, 2nd class hard wood , glazed & skeleton factory made shutters, open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I, Section-8, clause 8.20(a) complete all as specified.
250mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified.
200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed by Engineer-in-Charge.
Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified and as directed by Engineer-in-Charge.
300 mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate, ISI marked complete all as specified and as directed by Engineer-in-Charge.
S&F Steel windows/ventilator (Box type) factory made glass/glazed shutter, (glass panes shall be measured and paid separately) of size 60mmx25mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long complete all as specified & as shown on drg No. CEUZ/TD/1302/2009 Sh no 1/1 to 1/3 .
All as per item No 33 here-in-before but without glazing bars.
03 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified.
Galvanized mild steel wire-cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified.
Mild steel framed work as in grills, grating etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, conforming to Fe-410-0 or Fe-310-0, complete all as specified and directed by Engineer-in-Charge.
Preparation of new steel surfaces of any description exc 10 cm width or girth, priming with red oxide primer and painting with two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Painting to new wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, priming with pink primer (one coat) finished with two coats of synthetic enamel paint complete all as specified.
Supply and fixing of 8mm thick gypsum board false ceiling decorative vinyl lamination tiles (595x595mm) with aluminum foil backing for thermal insulation over GI snap grid frame work (Grid size 600x600mm) with powder coated GI angle of size 25x25x3mm, main runner 'T' of size 25xc40x3mm , secondary runner 'T' of size 25x30x3mm suspended with 3mm GI wire @ 1200mm c/c including dismantling of existing ceiling boards of any type and any thickness including cover fillets/GI grid framework complete all as specified and directed by Engineer-in-Charge.complete all as specified.
Dismantling timber scantling 40 Sqcm and over in section (framed work),in any position all as specified.
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
M&L for Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch, complete all as specified & directed.
All as per Srl item No. 43 here-in-above but for one 5 pin 6 Amps socket outlet on independent board.
All as per Srl item No. 43 here-in-above but for one 5 pin 6 Amps socket outlet on same board with other switches.
M&L for point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volt grade, single core of 2.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling/false ceiling including cutting chases as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 16 Amps controlled by one switch on independent board, complete all as specified & directed. Notes for Srl Item No. 43 to 46 (i) Unit rate includes for cutting chases whereever required and sinking for boxes, making good to walls / floors etc., complete, including white wash / colour wash as directed. (ii) Uniform coding of wiring i.e red / yellow / blue for phase black for neutral and green for earth is to be maintained.
Supply & fixing modular type switch 6 Amps, single pole, 1way,1 module,240V, ISI Marked complete all as specified and directed. Make Indoasian Glint,Crabtree, Havells REO
Supply & fixing modular type switch 16 Amps, single pole,1 way,1 module,240V, ISI Marked Complete all as specified and directed. Make Indoasian Glint,Crabtree, Havells REO
Supply & fixing modular type socket shuttered type 6 Amps- 2/3 Pin combined 2 module,240V,AC ISI Marked Complete all as specified and directed. Make Indoasian Glint,Crabtree, Havells REO
Supply & fixing modular type socket 6 A/16 Amps -2/3 Pin combined shuttered socket 2 module 240V AC ISI Marked Complete all as specified and directed .Make Indoasian Glint,Crabtree, Havells REO
Supply & fix fan regulator modular type electronic, stepped type 100 Watts, 2 module 240Volts,AC ISI marked complete all as specified and directed. Make Indoasian Glint,Crabtree, Havells REO
S&F ceiling rose 5 amp, 3 plates polycarbonate body complete all as specified & directed.
Supply and fixing sheet metal enclosure double door type for DBs single pole and neutral 8 way 240 V with 200 Amp bus bar including blanking plates where required including fixed flush in wall chases wall for fixing DB and making good surfaces to match with existing surface all as specified and directed. Make : Indoasian, Legrand, Schiender, Havells etc.
S&F in replacement MCB, single pole, (SP) 6 to 32 Amp, AC, 10 KA repturing capacity, ISI marked, 240 Volt, 'C' series, including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified & directed by Engineer-in-Charge.
Supply & fix MCB SPN 32 to 40 Amps 10 KA,"C" series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed Make : Legrand, Schiender, Havells etc.
S&F Earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 metre below normal ground level, surrounded on all sides by 150mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to and including earth lead wire 4.0mm (8SWG) by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electrical plate No 3 of SSR Part-I (2009) including taking down old existing earthing complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified & directed. Note : (a) The cost of earth work, PCC pit of size shown in electrical plate No.3, funnel, watering pipe, wire mesh, charcoal, dust, common salt, 20mm bore medium grade watering pipe & 15mm bore light grade GI pipe as protection to earth lead wire etc shall be deemed included in the unit rate for earthing. (b) After completion, during testing, if the earth resistance equal or less 2 ohms is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
Taking down UNSV flourescent fitting and M & L for LED batten Regal suitable for T8 LED tube incl T8 LED tube crystal glass with very high efficacy suitable for installation in existing T8 fitting with G13 lamp 20 watt 4 ft long all as specified and directed. Make : Havells Part No for batten- REGALBATTENT8UPTO1X22W DSBSWH, Cat Part No- LED Tube T8 : CRYSTAL1213T8DSTL18WLED865SGLASS or equivalent in CG, Philips, Bajaj . Note :- Rate quoted include the cost of both batten and Tube rod T8 and shall match with the batten .
Supply and fixing ceiling fans complete with blades. Down rods, electronic regulator and accessories, 230 volt, 1200mm sweep, min air delievery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) incl taking down existing and deposit with MES all as specified and directed.
S & F in replacement of 20 Watt LED energy saving light fitting environment friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 with GI bracket made of light grade GI pipe 40 mm dia of 1.2 mtr long bend to shape with 02 Nos of FI clamp 32 x 4mm with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable complete all as specified and directed . (Make- Havells, cat part No ENDURACITYLITEPLATSL20WLED757SASYBOPC or Bajaj/Philips/Crompton Greaves or its equivalent).
Supply, laying and testing XLPE insulated, electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, heavy duty cable, cross-sectional area 16 Sqmm 2 core laid in trenches or passing through pipes complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately) Make: Polycab, Gloster, Grandlay
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 mtr deep and getting out complete in any type of soil complete all as specified and directed
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
S & F in replacement of 20 Watt LED batten/inverter capacity having charging time 8 hours, driver efficiency > 85% , power factor > 95% and operating voltage 270 volt with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable complete all as specified and directed . (Make- Halonix/ Bajaj/Philips/Crompton Greaves or its equivalent).
M/S KARAN SINGH CONTRACTOR
Gupta Construction Company
M/s Sekinder Paul Sharma
JR CONSTRSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .