Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹23.2 L+₹2.4 L (11.6%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹26.0 L+₹5.2 L (25.1%)Rejected-AOC HIMACHAL BUILDING SHOP NO 10 CD BARFYWALA ROAD JUHU LANE ANDHERI W MUMBAI 400058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹26.9 L+₹6.2 L (29.7%)Rejected-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹27.8 L+₹7.0 L (33.7%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
6 Mar 2023, 6:00 pmClosed
GE(NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
REPAIR AND REPLACEMENT AND REROUTING OF UNSERV LT CABLE, LT PROTECTION SWITCHGEAR, APFC PANELS, CABLE DUCT COVERS, LT INSULATION MATS, STREET LIGHTS AND OTHER MISC ITEMS AND AT INS HAMLA AND ERANGAL AREA UNDER GE(NW) BHANDUP
2023_MES_578049_1
8251/B
Open Tender
Civil Works
Item Rate
270 days
Hamla
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹78,000
Yes
10 May 2023
30 Jan 2023
7 Mar 2023
30 Jan 2023
6 Mar 2023
20 Feb 2023
Amount
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed.
Returning, filling in including spreading , leveling , watering and well ramming in layers n.exc 25 cm with soil complete all as specified and as directed.
Supply and laying HDPE pipes of pressure rating 6 Kg/Cm sq of size 32 mm laid in trenches complete all as specified and directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed.
Supply and laying GI pipe 50 mm, light grade for the protection of the cable passing through road crossing, etc. complete all as specified and as directed.
Taking down existing LT UG cable from existing trench by manual excavation and finding the fault and make temporary joint with suitable ferruls and lugs and laying back the cable in trench and refilling the excavated soil back complete all as specified and directed by Engineer in charge for the cable sizes 10/16 sqmm 2/4 core Note: The excavation, earth work and protection materials will be measured and paid separately and relevant item
Taking down existing LT UG cable from existing trench by manual excavation and finding the fault and make temporary joint with suitable ferruls and lugs and laying back the cable in trench and refilling the excavated soil back complete all as specified and directed by Engineer in charge for the cable sizes 25/35 sqmm 3.5/4 core Note: The excavation, earth work and protection materials will be measured and paid separately and relevant item
Taking down existing unserviceable burnt out end termination of LT UG cable from LT panel, pole box etc and taking out loop by excavation and repairs the cable by providing with new aluminium lugs Including Disconnection of Old Dummy cables of any size and removing from the pole and Cutiing upto loop end complete all as specified and directed for the cable size 2 core 10 sqmm.
All as above item No 8.00 but for cable sizes between 4 core 16 sqmm to 3.5 Core 50 Sqmm complete all as specified and directed.
All as above item No 8.00 but for cable sizes 50 to 95 Sqmm 3.5 Core complete all as specified and directed.
All as above item No 8.00 but for cable sizes 120 to 185 Sqmm 3.5 Core complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI earth strip 32 x 6mm by mean of bolts, nuts, check nuts and washer of galvanised iron steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe of suitable size including testing on completion all as specified and directed.
Taking Down Old U/S LT UG Cables of any size getting Out from the replacement with new cables complete all as specified and directed.
Supply and laying in replacement of cable LT XLPE 4 core 16 sqmm insulated and screened PVC bedded, galvanised steel strip armoured electric power cable (heavy duty) with Multi stranded aluminium conductor, 1100 Volts grade complete all as specified and directed. Note : The rate quoted by the Contractor Including including taking down existing u/s LT cable.
All as above item No 14.00 but for cable size 3.5 core 120 sqmm complete all as specified and directed.
All as above item No 14.00 but for cable size 3.5 core 95 sqmm complete all as specified and directed.
All as above item No 14.00 but for cable size 3.5 core 70 sqmm complete all as specified and directed.
All as above item No 14.00 but for cable size 3.5 core 50 sqmm complete all as specified and directed.
All as above item No 14.00 but for cable size 3.5 core 35 sqmm complete all as specified and directed.
All as above item No 14.00 but for cable size 3.5 core 25 sqmm complete all as specified and directed.
All as above item No 14.00 but for cable size 2 core 10 sqmm complete all as specified and directed.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and drawing through the pole for making connections to the Street light/Flood Light fittings,three core,PVC insulated and sheated, Heavy duty,1100 volts grade,multistranded copper conductor(FRLS) cable 2.5 sqmm, complete all as specified and directed
Supply and Fix in Replacement of Unserviceable LED Drivers with New Drivers of any ISI Approved Make having IP 66 Protection of any Current Rating Suitable to Existing Street Light Or Flood Light Fittings of Any Wattage Complete all as specified and Directed. Note : The Rate quoted by the Contractor Includes Removing Of LED Fiiting from the existing pole and Refixing after replacement of LED Driver.
Material and labour for Repairs to replacement of Unserviceable Street Lights Digital Timer switch single phase 230V Operated 50 hz frequency with inbuilt chargeble battery backup upto minimum 24 hrs complete all as specified and directed. Make : L & T GIC Digital Timer or any equivalent Specifications of ISI Make as approved by the GE.
Material and labour for replacement of un serviceable 3 pole 415 Volts power contactors Current Rating Up to 50 Amps for Street Light Timer switches complete all as specified and as directed Make : L&T cat part No MNX 50 or any equivalent of Siemens/Schnider
M&L for Preparation of old exposed surface of LT steel tubular poles of any type / height with bracktes clamps etc and painting with one coat of aluminium paint upto 6 mtr long and exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole no's with paint complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) for 7 Mtr height GI Octagonal pole foudation of Size 1.5m x 0.55m x 0.55m, footings,columns, postd, pillars etc with 10 mm Iron rods in Verticle and 6 mm dia Iron rods as Stirrups in any location, complete all as specified and directed.
Supply and fixing in replacement of GI street light pole connected items such as 4 way connector bolts for RYBN Connection, inside the pole of Cable Connector space and MCB SP 'C' series 6 Amps rating also Changing 2.5 sqmm FRLS Cable Lugs complete all as specified and directed.
Supply and fixing in replacement pole mounting box FRP type of size 140mm x 140mm x 100 mm, single phase with locking arrangements, including necessary nut, bolt and clamps of the flat iron of size 20mm x 3 mm comprising of MCB SP 6 Amps, 240 Volts, 10 KA, 'B' series with proper fixing arrangements on pole complete all as specified and directed. Make: National/ Sintex
Supply and laying HDPE pipes of pressure rating 6 Kg/Cm sq of size 50 mm laid in trenches complete all as specified and directed.
Supply and laying un-reinforced pre cast concrete cable cover, class LV type I with flat size 250mm x 150mm x 40mm complete all as specified and directed.
Material and Labour for dry fine sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete all as specified and directed. Note : [Punned thickness 18 cm shall be measured & paid]
Supply and laying GI pipe 100 mm dia light grade for the protection of the cable passing through road crossing, etc. complete all as specified and directed.
Material and labour for RCC 1:2:4 type B1 (using 20mm graded stone aggregate) for filling the disturbed road opening for cable crossing include levelling with road surface and smooth finishing complete all as specified and directed.
Disconnecting the existing LT UG cable ( Cable sizes between 3.5 Core x 50 sqmm To 3.5 Corex 400 sqmm of any length) Terminals from both ends of Panel by injecting the Surge voltage(Hipot Testing) and finding the fault by Cable fault reflectometer Machine and make temporary joint with suitable ferruls and lugs and laying back the cable in trench and refilling the excavated soil back complete all as specified and directed.
Material and labour for straight through joint at the cable in ground or End termination Joint at panel Connection with heat shrinkable type for underground LT cable 1100 volt for the size 25/35 Sqmm 3.5/4 core complete all as specified and directed.
(b) 50/70 Sqmm 3.5 core
(c) 95/120 Sqmm 3.5 core
(d) 150/185/240 Sqmm 3.5 core
Supply and fix in replacement of Unserviceable MCCB 4 pole 63-100 Amps 415Volt 50Hz breaking capacity 16 KA adjustable with suitable size Lugs and Screws Fitted in existing Indoor/Outdoor LT Panel Including complete all as specified and directed.
Supply and fix in replacement of Unserviceable MCCB 4 pole 160-200 Amps 415Volt 50Hz breaking capacity 25KA adjustable with suitable size Lugs and Screws Fitted in existing Indoor/Outdoor LT Panel Including complete all as specified and directed.
Supply and fix in replacement of Unserviceable MCCB 4 pole 325-400 Amps 415Volt 50Hz breaking capacity 25KA adjustable with suitable size Lugs and Screws Fitted in existing Indoor/Outdoor LT Panel Including complete all as specified and directed.
Supply, installing, testing and commissioning factory made and tested LT Panel Outdoor type(C.P.R.I Approved), platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system conforming to IS : 375 all as specified herein after. Degree of protection shall not be less than 1P-42 as per IS : 2147 shall be dust and vermin proof, and made of 2.00 mm thick Stainless Steel Sheet SS316 grade & suitable frame made out of MS Iron angle frame, front and Back opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal Connections Shall be Aluminium Bus bar only if MCCB rating is 100 Amps and above sizes, Copper wiring with PVC FRLS insulated multistranded copper conductor FRLS cable can be done of adequate size for MCCB rated below or equal 63 Amps complete all as specified and directed.(Location Behind Delhi Bldg NSB) Note :The panel manufacturer should have Govt. Approved CPRI Certification.and The contractor duly shall submit the Manufacturer'S Design and drawings of LT panels before placing the order. Make : Universal Switch Gear Control/Perfect Engineers. or any equivalent C.P.R.I Certified Make as approved by the GE.
The scope of work also comprising of the following:- BUS BAR CHAMBER :- (a) 300 Amp 4 Strips, Aluminium conductor, with color coded(R,Y,B,N) heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Multifunction Meter- 01 Set. (ii) R,Y,B,Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). (iii) Protection MCB 6 A SP C Series- 1 Set. (Set of three). (iv) CT 400/5A Set of -03 Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. INCOMING SUPPLY :- (i) MCCB 160 Amps breaking capacity 25 KA, 4 Pole, 50Hz at 415 Volts, Thermal and Magnetic release-01 Nos OUTGOING SUPPLY :- (i) MCCB 100 Amps 25 KA, 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz = 01 Nos. (ii) MCCB 63 Amps 25 KA, 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz = 04 Nos. (iii) MCB TPN 63 Amps 16 KA, 4 Pole 'B' Series 415 volts , 50Hz = 02 Nos. Note : All MCCB'S shall conform to IS : 13947 (Part 3, 1993) and IEC-60947 (Part 2) with MES Approved List Makes
Material and labour for complete removal of existing treatment of the existing Panel surface of LT Feeder Piller and painting with two coats of synthetic enamel paint over one coat of primer complete all as specified and directed.
Supply and fix in repairs LT cable route indicator made out of cast iron 10cm dia duly engraved with letters 'LT CABLE 1100 volts' fixed in 20mm x 20mm equal angle 60cm long including provision of PCC block of 20cm x 20cm complete all as specified and directed.
Supply and fix in replacement 40mm dia GI Garden pole Light grade Upto 4 mtrs long for existing garden light pole for replacing unserviceable poles including dimantling existing GI Pole complete all as specified and directed.
Material and labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) for foundation, filling and mass concrete complete all as specified and directed.
Supply and fixing in replacement of U/S post top lantern LED type 25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
All as per item No.50 above but for 20 Watt LED Post Top Lantern, Complete all as specified and directed.
Supply and fixing in replacement of U/S LED Bollard light 8-12 watt 230 watt volts AC outdoor type with for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
M & L prepration of old exposed surface of garden light for the 40/50 mm dia size having any height by applying two coats of aluminium paint including painting to bottom of pole complete all as specified and directed.
M & L for Stickering the Pole Numbers( Numbers and Alphabets)serial wise of digitally printed type having plastic surface transperent cover over the sticker paper having round shape of dia minimum 4 cm and stcky surface on back side of the paper to sticking over the surface of the GI Octagonal Poles complete all as specified and dicrected.
Supply and fixing in replacement pole mounting box FRP type IP 55 Protection of size 150mm x 125mm x 100 mm, single phase with locking arrangements, including necessary nut, bolt and clamps of the flat iron of size 20mm x 3 mm comprising of MCB SP 6 Amps, 240 Volts, 10 KA, 'B' series with proper fixing arrangements on pole complete all as specified and directed. Make: National/ Sintex
M & L for Fixing MS Chequered cover plate Over Cable ducts inside the sub station building with a thickness of 5-6 mm and standard sizes of 1.2 m x 0.6 m / 1.3x0.35 m / 0.9x0.35 m include provision of Handle over top surface both ends to catch the Cover while removing including MS angle frame under Duct Cover sheet To be fix over the concrete/PCC duct foundations complete all as specified and directed.
Supply ands Fixing in replacement of Unserviceable LED Drivers Input AC single phase 50 HZ,230 Volts operated with IP 65 Protection Suitable for Outdoor Street Lanterns with Power Output rating 30 watts complete all as specified and directed.
Supply ands Fixing in replacement of Unserviceable Multi LED PCB Round Shape 15 cm dia Approx 1-2 mm thickness Aluminium base Copper clad with warm white LED Light Output of 30 watts having IP 65 Protection Suitable for Outdoor Street Lanterns complete all as Specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 142695.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
Shree Ayyappa Engineering
M/s PIONEER CONTRACTORS
M/s Mukesh Engineers
industrial suppliers
NANGIA AND CO
M/s ASPIRE ENGINEERING ENTERPRISES
ELECTRO ASSOCIATES
M/S VAIBHAVI ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .