RATE CONTRACT FOR REPAIRING OF EI AND ACs AT VARIOUS T.E. BLDGS AND BTS IN SSA JAMMU
2022_BSNL_126587_3
13/EE(E)/II/BSNL/JMU/2022-23
Open Tender
Electrical Works
Item Rate
365 days
SSA Jammu
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
AO Cash office of GMTD BSNL Jmmu
₹61,887
9 Sept 2022
24 Aug 2022
8 Sept 2022
24 Aug 2022
5 Sept 2022
24 Aug 2022
24 Aug 2022 - 5 Sept 2022
90 days
Replacement of faulty wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required :- Group A
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required :- Group B
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required :- Group C
Replacement of faulty / burnt wiring with supplying & drawing of new 3 x 1.5 sq. mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Replacement of faulty wiring with supplying & Drawing of new 6 x 1.5 sq. mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Replacement of faulty wiring with supplying & Drawing of new 3 x 2.5 sq. mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Replacement of faulty wiring with supplying & Drawing of new 3 x 4 sq. mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Replacement of faulty wiring with supplying & Drawing of new 6 x 4 sq. mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Replacement of faulty wiring with supplying & Drawing of new 3 X 6 sq. mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Replacement of existing faulty conduit with supplying & fixing of new 20 mm dia of medium class PVC conduit along with accessories in surface/recess with new ones including cutting the wall and making good the same in case of recessed conduit as required.
Replacement of existing faulty conduit with supplying & fixing of new 25 mm dia of medium class PVC conduit along with accessories in surface/recess with new ones including cutting the wall and making good the same in case of recessed conduit as required.
Replacement of existing faulty switch box with supplying & fixing of new 75 mm X 75 mm X 60 mm deep new metal box (nominal size) on surface or in recess with new one with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
Replacement of existing faulty switch box with supplying & fixing of new 100 mm X 100 mm X 60 mm deep new metal box (nominal size) on surface or in recess with new one with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
Replacement of existing faulty switch box with supplying & fixing of new 180 mm X 100 mm X 60 mm deep new metal box (nominal size) on surface or in recess with new one with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
Replacement of faulty 5/6 amps switch with removing faulty & supplying & fixing of new 5/6 amps piano type switch on the existing switch box/ cover including connections etc. as required.
Replacement of faulty 5/6 amps socket with removing faulty & supplying & fixing of new 5/6 amps socket on the existing switch box/ cover including connections etc. as required.
Replacement of faulty 15/16 A switch with removing faulty & supplying & fixing of new 15/16 amps piano type switch on the existing switch box/ cover including connections etc. as required.
Replacement of faulty 6 pin 15/16 A socket outlet with removing faulty & supplying & fixing of new 15/16 amps socket outlet on the existing switch box/ cover including connections etc. as required.
Replacement of faulty holder with supplying & fixing of new PVC batten/ angle holder including connections etc. as required.
Replacement of faulty MCB DB with supplying & fixing of new 8 way , Double door , single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Replacement of faulty MCB DB with supplying & fixing of new 12 way , Double door , single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Replacement of faulty single pole MCB with supplying & fixing of new 5 A to 32 A rating single pole 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Replacement of faulty double pole MCB with supplying & fixing of new 5 A to 32 A rating single pole 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of double pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Replacement of faulty triple pole MCB with new 5 A to 32 A rating single pole 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of triple pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Replacement of faulty triple pole & Neutral MCB with supplying & fixing of new 5 A to 32 A rating single pole 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Replacement of faulty 40 A , double pole, 240 V, isolator with supplying & fixing of new one in the existing MCB DB with new one complete with connections, testing and commissioning etc. as required.
Replacement of faulty 63 A , double pole, 240 V, isolator with supplying & fixing of new one in the existing MCB DB with new one complete with connections, testing and commissioning etc. as required.
Replacement of faulty 100 A , double pole, 415 V, isolator with supplying & fixing of new one in the existing MCB DB with new one complete with connections, testing and commissioning etc. as required.
Replacement and fixing of 25mm x 16mm sizes of PVC casing and capping for covering of loose wires etc. complete as reqd.
Replacement and fixing of 30mm x 15mm sizes of PVC casing and capping for covering of loose wires etc. complete as reqd.
Replacement and supplying/ fixing of power strip of 6 Amp rating having 4 nos. 5 /6Amp 3/5 pin socket outlet controlled by common switch with surge protection suitable for 230 Volts, 50 Hz Single phase AC supply having connecting lead, safety fuse etc. complete as reqd. (Make: Havells/ Anchor/Panasonic/ Philips)
Replacement and supplying & laying of 2 x 1.5 Sq mm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
Replacement and supplying & laying of 3 x 1.5 Sq mm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
Replacement and supplying & laying of 3 x 2.5 Sqmm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
Replacement and supplying & laying of 3 x 4 Sq mm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
Replacement and supplying & laying of 3 x 6 sqmm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
Replacement of faulty 2X 40 W / 1 x 40 W / box type flourescent fitting with supplying & fixing of 4' long 18/20 Watt LED fittting as light source, suitable for operation on 220 volt single phase ac supply complete connections etc. complete as reqd.( M/s Crompton / Havells of similar superior make )
Replacement of faulty lamp including dismantling faulty and supplying & fixing new 9/10 Watt LED lamp in the existing fitting etc complete T &C as required
Replacement of faulty lamp including dismantling faulty and supplying & fixing new 20 Watt LED lamp in the existing fitting etc complete T &C as required
Rewinding of Wall Fans / Ceiling Fans of all size complete with dismantling, winding with suitable size copper wire, varnishing, drying, refixing etc complete as reqd.
Rewinding of Exhaust Fans of all size complete with dismantling, winding with suitable size copper wire, varnishing, drying, refixing etc complete as reqd.
Replacement of faulty 70/250W HPSV street light including dismantling faulty and supplying & fixing new 25 Watt LED Die Cast Alum. Housing Street Light Energy saving dust and water proof LED fitting with inbuilt controller suitable for operation on 220 V to 240 Volt etc. on existing duly fixed on the existing GI bracket with nuts & bolts etc reqd.( M/s Havells, Philips, CG, Bajaj, Wipro or SS make)
Carrying out Wet Servicing of 1.5TR / 2TR Window / Split AC unit i/c removing, cleaning all components and filters, de-dusting by high pressure air blower, washing condenser, evaporator i/c chemical cleaning (if required), refixing, tightening electrical connections, minor repairs, if required, testing of AC unit, recording all parameters in service report etc as reqd.
Charging of refrigerant gas in split air conditioner complete with carrying out leak testing of 1.5TR/ 2 TR Split AC units with nitrogen gas including flushing the system, brazing/flaring the leak points, vacumising, purging and making the system leak proof i/c transportation of nitrogen cylinder, brazing kit & vacuum pump, supplying & charging of refrigerant gas at site,testing & commissioning etc as required.
Replacement of faulty /defective 1.5 TR capacity compressor with new Sealed compressor i/c dismantling of faulty compressor, cutting refrigerant piping, brazing & making necessary addition/alteration i/c proper mounting on base plate, connection of suction and discharge lines, Leak test , supplying & charging required qty. refrigerant gas i/c testing commissioning etc as reqd.(M/s Emerson/Tecumseh/SS make) (Note - The firm shall submit test certificate or documentary proof towards purchase of New/OEM factory repaired compressor.) The defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory)
Replacement of faulty /defective 2.0 TR capacity compressor with new Sealed compressor i/c dismantling of faulty compressor, cutting refrigerant piping, brazing & making necessary addition/alteration i/c proper mounting on base plate, connection of suction and discharge lines, Leak test , supplying & charging required qty. refrigerant gas i/c testing commissioning etc as reqd.(M/s Emerson/Tecumseh/SS make) (Note - The firm shall submit test certificate or documentary proof towards purchase of New/OEM factory repaired compressor.) The defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory)
Replacement of faulty damaged Condenser Fan Motor for Split AC unit in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged Indoor Fan Motor for Split AC unit in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged Blower in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged PCB assembly main in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged 5-32 A SP&N MCB C-series in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged Fan blade in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged PCB Control card of 1.5 TR inverter type AC unit for I/D unit in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged PCB Control card of 1.5 TR inverter type AC unit for O/D unit in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of faulty damaged Copper piping for Hot & cold lines in existing window / split AC units including removal of faulty spares , supplying and fixing new one testing , commissioning etc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
Replacement of choked / faulty 20 mm dia PVC drain pipe in recess or on surface for drainage of split AC units i/c connections etc complete as reqd.
FAIRDEAL ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .