Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.6 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹14.7 L+₹70,405 (5.02%)Rejected-AOC | L-2 | Rejected-AOC other than Lowest bidder | |
| 3 | L-3₹16.8 L+₹2.7 L (19.6%)Rejected-AOC | L-3 | Rejected-AOC other than Lowest bidder | |
| 4 | L-4₹17.5 L+₹3.5 L (24.8%)Rejected-AOC | L-4 | Rejected-AOC other than Lowest bidder | |
| 5 | L-5₹17.5 L+₹3.5 L (24.8%)Rejected-AOC BASTI GOVINDPURA SIMBAL MORH MAKHANPUR GOJRAN JAMMU J K 181101 | JAMMU | JAMMU AND KASHMIR | 181101 | L-5 | Rejected-AOC other than Lowest bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
18 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ram G
GE Kaluchak Pin-900673
REPAIR AND CLEANING OF SEWAGE LINES, MANHOLES, SEPTIC TANKS, SOAKAGE WELLS AND CONNECTED ITEMS AT BD BARI MIL STN UNDER GE KALUCHAK
2023_MES_590396_1
GE/KC/NIT-07/2023-24
Open Tender
Civil Works
Item Rate
270 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹50,000
Yes
16 Jun 2023
20 Apr 2023
25 May 2023
20 Apr 2023
18 May 2023
4 May 2023
20 Apr 2023 - 27 Apr 2023
Amount
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed.
All as per Srl item No.1 above but depth exc 1.5m and not exc. 3.0m deep in any type of soil.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, internal dia of pipe 200mm, complete all as specifed & directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, internal dia of pipe 150mm, complete all as specifed & directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, internal dia of pipe 100mm, complete all as specifed & directed.
Concrete bed to 200mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) type D-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) type D-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Concrete bed to 100mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) type D-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
200mm dia DWCPE (SN8) HDPE pipes, laid in trenches on PCC bed, jointed as per manufacturers instructions, complete all as specified & directed. Note : Earthwork, PCC bed/ haunching shall be measured and paid for seperately under respective items.
150mm dia DWCPE (SN8) HDPE pipes, laid in trenches on PCC bed, jointed as per manufacturers instructions, complete all as specified & directed. Note : Earthwork, PCC bed/ haunching shall be measured and paid for seperately under respective items.
100mm dia DWCPE (SN8) HDPE pipes, laid in trenches on PCC bed, jointed as per manufacturers instructions, complete all as specified & directed. Note : Earthwork, PCC bed/ haunching shall be measured and paid for seperately under respective items.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching, internal dia of pipe 200mm, complete all as specified & directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching, internal dia of pipe 150mm, complete all as specified & directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching, internal dia of pipe 100mm, complete all as specified & directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified & directed.
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified & directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4 but except brick i.e. using serviceable bricks obtained from Srl item No. 19 here-in-before, complete all as specified & directed.
PCC 1:3:6 nominal mix, type C-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in benching, water troughs and the like including necessary form work, complete all as specified & directed.
Precast cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 including necessary form work, complete all as specified & directed.
TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specifed & directed.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
Dismantling water tanks of capacity exc 250 litres but n exc 500 litres, complete all as specified & directed.
Dismantling water tanks of capacity exc 500 litres but n exc 1000 litres, complete all as specified & directed.
Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top), triple layer, connecting up pipes, securing access covers etc, hoisted & fixed in position of capacity 1000 ltrs, complete all as specified & directed.
Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top), double layer, connecting up pipes, securing access covers etc, hoisted & fixed in position of capacity 500 ltrs, complete all as specified & directed.
Taking up or down steel tubing and connections 20mm bore, complete all as specifed & directed.
Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed.
Galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Refixing old steel tubing and connections of 20mm bore in new or old position (Walls, ceiling, floors etc.) including cleaning for refixing, complete all as specified and as directed .
Refixing old steel tubing and connections of 15mm bore in new or old position (Walls, ceiling, floors etc.) including cleaning for refixing, complete all as specified and as directed .
Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for bore of pipe 20mm, fixed in repairs, complete all as specified & directed.
Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for bore of pipe 25mm, fixed in repairs, complete all as specified & directed.
Vitreous china wash down water closet (Pedestal pattern), white with ‘P’ or ‘S’ trap, plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device fixed with screws of suitable size including making connections to trap and to flush pipe, fixing flushing cistern etc. and making good to floors, fixed in repairs, complete all as specified & directed.
Vitreous chinaware squatting pan, 'Orissa Pattern' size 580mm x 440mm with integral foot rests, white, with ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs, complete all as specified & directed.
PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long, fixed in repairs, complete all as specified & directed.
Vitreous china, wash hand basin, flat back, white of size 580mmx450mm including brackets, brass CP waste coupling 32mm dia with long screwed shank and fly nuts, chain and plug, porcelain stopper including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs, complete all as specified & directed.
PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, complete all as specified & directed.
Dismantling of PVC (SWR) drain pipe, internal dia of pipe 75/110mm, complete all as specifed & directed.
PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with MS clamps, 110mm bore, complete all as specified and directed.
110mm bore PVC (SWR) bends any radius, complete all as specified & directed.
PVC (SWR) branch piece, single (single Y) equal or unequal, 110mm bore, complete all as specified.
PVC (SWR) junction single (Single T) equal or unequal, 110mm bore, complete all as specified & directed.
PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified & directed.
75mm bore PVC (SWR) bends any radius, complete all as specified & directed.
PVC (SWR) branch piece, single (single Y) equal or unequal, 75mm bore, complete all as specified.
PVC (SWR) junction single (Single T) equal or unequal, 75mm bore, complete all as specified & directed.
PVC (SWR) cowl of 75mm bore, fixed in repairs, complete all as specified & directed.
Cleaning/ clearing of sewage line (including manholes) of 200mm bore of any description, underground at any depth, removing any type of blockage including desilting, descaling & dechocking of drains as well as manholes with combined high pressure water jetting cum suction (vacuum) type machine mounted on LCV/ HCV and having facilities of high pressure vacuum and provision of hydraulic application through high pressure thermo plastic fibre based water jetting hose and conical round shape nozzle pipe and flushing after cleaning including removing the same in the tank to a place outside cantonment at the place meant for the purpose by local municipality, complete all as specified & directed.
Cleaning/ clearing of sewage line (including manholes) of 100mm to 150mm bore of any description, underground at any depth, removing any type of blockage including desilting, descaling & dechocking of drains as well as manholes with combined high pressure water jetting cum suction (vacuum) type machine mounted on LCV/ HCV and having facilities of high pressure vacuum and provision of hydraulic application through high pressure thermo plastic fibre based water jetting hose and conical round shape nozzle pipe and flushing after cleaning including removing the same in the tank to a place outside cantonment at the place meant for the purpose by local municipality, complete all as specified & directed.
Desludging / dewatering of septic tanks/ soakage wells including inlet / outlet chambers, removing out all scum, silt, residual sludge (both organic & inorganic in nature) after plugging the incoming sewage lines through combined high pressure water jetting cum suction (Vacuum) type machine mounted on LCV/HCV facility of high pressure vacuum and removing the same in the tank to a place outside cantonment at the place meant for the purpose by local municipality, complete all as specified & directed.
Cleaning of blocked WC including and upto first manhole manually and well flushing with clear water, making the seat functional including depositing the sludge in a pit (including digging of pit) not less than 100 meter away from site of cleaning and covering the deposited sludge with minimum 25cm thick layer of earth and spreading unslacked lime on the pit, complete all as specified & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified and directed.
Glazed ceramic coloured tiles of size 450mmx300mm, thickness 7 to 8mm as in vertical surfaces such as wall, pillar, skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Jet spray CP with 1 mtr long tube for 15mm bore pipe and mild steel chromium plated hinging device for pedestal type WC, fixed in repairs, complete all as specified & directed.
Chromium plated hand shower (Health Faucet) with with 8mm dia 1 meter long easy flex tube in chrome finish & wall hook, fixed in repairs, complete all as specified & directed.
Stainless steel grating of 125mm size (square/round), male/female pattern with or without hole, fixed in nahani/floor traps with white/coloured cement, fixed in repairs, complete all as specified & directed.
Brass chromium plated WHB mixer for mixing hot & cold water screwed down for iron pipe and fixed for 15mm bore of pipe, fixed in repairs, complete all as specified & directed.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered `Hot’ or `Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe of 15mm bore, fixed in repairs, complete all as specified & directed.
Stop valves, cast copper alloy, 20mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
Stop valves, cast copper alloy, 15mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
Bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified & directed.
Stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
Angle valves, 15mm bore, fancy type, chromium plated, cast copper alloy with capstan head, screwed down, high pressure, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
Complete removal of the existing sunken treatment including roughening and preparation old surfaces of concrete floor by picking, scurubbing down with steel brushes, sweeping clean and washing down with water to remove dust etc and applying the following treatment :- (a) 15 thick rendering on fair faces of brick work or cement surfaces in cement mortar 1:4 with using integral water proofing compound as per manufacturer instructions by weight of cement to sunken portion including wall of sunken portion with proper slope towards outside and finishing cement concrete or brick work surface even and smooth using extra cement, finishing concrete including walls of sunken portion with proper slope. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3mm thick weight not less than 3.6 Kilogram/Square Metre with 160 Grams/Square Metre non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kilogram/Square Metre. Note : Ponding shall be done in sunken portion area by filling water which shall be kept there for 48 Hours. In case a slightest indication of seepage/leakage is noticed, the same shall be rectifird by grounting the effected area at no extra cost. Thereafter, ponding shall be repeated till there is no indication of seepage/leakage. The arrangements of ponding to be included in quoted rates and nothing shall be admissible on this account.
M/S SUDAGAR MAL
ASHFAQ AHMED MANHAS
M/s Des Raj and Sons
J P TECHNO
M/s K.S. Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .