Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1ST₹25.5 LAccepted-Finance CHANDPORA HABBAKADAL HABBA KADAL SRINAGR CHANDPORA HABBAKADAL HABBA KADAL SRINAGR SRINAGAR JAMMU AND KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | 1ST | Accepted-Finance VALID BID | |
| 2 | 2ND₹28.8 L+₹3.3 L (13.0%)Accepted-Finance | 2ND | Accepted-Finance VALID BID | |
| 3 | 3RD₹30.0 L+₹4.5 L (17.6%)Accepted-Finance | 3RD | Accepted-Finance VALID BID |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
24 Dec 2021, 4:00 pmClosed
OFFICE OF THE EXECUTIVE ENGINEER EDIV
OFFICE OF THE EXECUTIVE ENGINEER EDIV KHANYAR
Improvement of HT/LT network by replacing old worn out/ decayed conductor and poles at various locations pertaining to Sub Division Hawal Rainawari Khanyar K.K.Moulla and Zakura within the jurisdiction of EDIV Khanyar
2021_PDD_152499_1
EDIV/63 OF 2021
Open Tender
Electrical and Maintenance Works
Turn-key
10 days
ZAKURA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
OFFICE OF THE EXECUITVE ENGINEER EDIV KHANYAR
₹30,000
Yes
12 Jan 2022
10 Dec 2021
27 Dec 2021
10 Dec 2021
24 Dec 2021
10 Dec 2021
10 Dec 2021 - 10 Dec 2021
particulars
Supply installtion testing and commisssioning of 9 Mtr. Long ST Poles (410, SP-33) with pit excavation
Installtion testing and commisssioning of 9 Mtr. Long ST Poles (410, SP-33) with pit excavation poles to be provided by department conditional which are to be lifted from Diviisonal stores Kindly read condtion No 11 of the SBD
Supply installtion testing and commisssioning ofof 8 Mtr. Long ST Poles (410 SP15) with pit excavation
installtion testing and commisssioning ofof 8 Mtr. Long ST Poles (410 SP15) with pit excavation poles to be provided by department conditional which are to be lifted from Diviisonal stores Kindly read condtion No 11 of the SBD
Supply Laying testing and commisssioning of 50 mm² ACSR (Rabbit) conductor including joints with PG clamps of required size
Laying testing and commisssioning of 50 mm² ACSR (Rabbit) conductor including joints with PG clamps of required size conductor to be provided by department conditional which is to be lifted from Diviisonal stores Kindly read condtion No 11 of the SBD
Supplying and erection of GI Channel cross-arm (75 x 40x6mm) 6 ft long with GI Angle Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure.
Supply installtion testing and commisssioning of 11 KV Polymeric Composit pin with insulator insulator 12 KV, 5 KN,Light Impulse 75 KVPositive and 80 KV Negative ,Creepage distance 320 mm
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1700mm for 8/9 mtrs Long ST Poles (410, SP-15/33) (the leftover pit after concreting to be filled with soil and boulders)
Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each pole including supply and welding of GI channel 70x40x150 on pole for earth connection
Supplying and erection of Danger Plates with clamps with writing in English and Regional Language as per REC Standard
Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose.
Supplying and fixing of Galvanized Nuts and Bolts of sizes.
Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Providing, fixing and Commissioning of LT Shackle insulators as per REC standard
Supply and fixing of MukKI Clamps fibricated out of 50x8 mm flat iron of appropiate size and specification for holding LT Shackle insulators.
Dismentelling of old poles/ conductor as per actul material reteived from site & carriage upto Divisional Stores and stacking of the same( rates to be Quoted for Full Job from all sites)
Providing of Stencil and spray painting (black in Colour) on each pole at an height of 4.5 feet above ground levelwith following specification :- 1. The dimension of the stencil should be not less than 21"x 9" per Pole . 2. The following details are to be recorded on each pole with the spray paint. a. Name of the work b. Year c. Name of The contractor d. SR of the Pole. The said stencil should be approved by EDIV KHANYAR
Pre and post Geo tagged photographic Evidence consisting of 5x7 inch Photographs in coffee table book ( 1 pre And 1 Post Photograph of Each Pole )
DAR BROTHERS ELECTRONICS
M.I ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .