Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.1 LAccepted-AOC 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹17.5 L+₹2.0 L (12.9%)Rejected-Finance | 2 | Rejected-Finance Not being lowest |
Tender Value
₹22.1 L
EMD Value
₹44,180
Closing Date
10 Nov 2020, 6:00 pmClosed
HQ CWE Agra
112 Taj Road, Agra Cantt
SPL REPAIR TO TOILET BLOCK OF BLDG NO. P-135 OF 29 PARA UNDER GE (EAST) AGRA
2020_MES_386110_1
84184/E8
Open Tender
Civil Works
Item Rate
180 days
Agra
MES contractors enlisted in Class E category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
GE East Agra
₹44,180
Yes
20 Nov 2020
13 Oct 2020
16 Nov 2020
13 Oct 2020
10 Nov 2020
27 Oct 2020
13 Oct 2020 - 20 Oct 2020
Amount
M&L for preparation of old plastered or unplastered surfaces of wall by brooming down by steel wire brushing scrapping down smoke soot moulds moss & efflorescent salts and trading oil and greasy spots etc and apply two coat of white wash complete all as specified and directed.
All as per item No.1 above but two coat of white wash on ceiling complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of wall by brooming down by steel wire brushing scrapping down smoke soot moulds moss & effloresecent salts and trading oil and greasy spots, removing all vegitation growth etc and apply one coat of cement base paint white or tinted complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified and directed..
Taking down old cement plaster on brick or concrete surface of wall / column, ceiling and soffits of chajja etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Material and labour for rendering 10mm thick on fair faces of concrete surfaces of ceiling and other smilar work etc in cement mortar 1:3 and finished even and fair as in wall complete all as specified and directed.
Material and labour for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth as in wall complete all as specified and directed.
Material and labour for rendering 15 mm thick on other than fair faces (external surfaces of wall) of brick work or concrete surfaces in cement mortar 1:6 and finished fair and even with & including WPC as per manufacturer's instructions complete all as specified and directed.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement base paint over cement base primer. complete all as specified and directed.
M&L three coat of white wash on newly plastered surfaces of walls including preparation of surfaces Complete all as Specified and directed
M&L three coat of white wash on new plastered surfaces of ceilings including preparation of surfaces Complete all as Specified and directed
Demolition of cement concrete (unreinforced) of any description in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises, complete all as specified and directed.
Taking down Chowkhats or frames with shutter (without taking off shutters from the frame) n. exc. 1.50 sqm each complete all as specified and directed.
Taking down Chowkhats or frames with shutter (without taking off shutters from the frame) exc. 1.50 sqm and n. exc. 4.00 sqm each complete all as specified and directed.
Taking up or down existing steel tubing and connections of walls ceiling, floor etc of 15 mm bore complete all as specified and directed.
All as per item No.17 above but 20 mm bore complete all as specified and directed.
All as per item No.17 above but 25 mm bore complete all as specified and directed.
Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
All as per item No.20 above but 20 mm bore complete all as specified and directed.
All as per item No.20 above but 25 mm bore complete all as specified and directed.
M&L for cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills sunshades, shelves lintels etc and cutting chases for concealed water pipe etc and making good cutting exc. 10 cm and not exc 20cm.complete all as specified and directed.
Dismantling and taking down of existing water storage tank any type & any capacity complete and removing from site and S&F rotational moulded polyethylene water storage tanks 5000 liter capacity (cylindrical vertical with closed top) with and including ball brass valves, high pressure with polythene float and fly nut complete screwed for 20 mm bore iron pipe or for brass ferrule, hoisted and fixed in position complete as specified in SSR Part I 2009 complete all as specified & directed.
S&F in repair stop valves, cast copper alloy with flange fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfllly handles, screwed both ends for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed
S&F in repair angle valve, with flange 15 mm nominal bore cast copper alloy, chromium plated fancy type with screwed down high pressure, with crutch or butterly handle screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified and directed.
S&F in repair single towel rail , brass, chromium plated, fancy type, 60 cm long between flanges fixed with and including CP brass screws, rawl plug etc complete all as specified and directed
S&F in repair 20 mm dia gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs bib taps with flange, cast copper alloy , fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
M&L for 3 mm thick figured glass pin headed type and glazing with steel pin and oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
M&L Brick work with sub class 'B' bricks, old size straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as Specified and directed
M&L for non skid coloured Ceramic joint free tiles,first quality( of approved class , colour and design/ shade) 7 to 8 mm thick (Square/ rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, ,as in floor surface etc set and jointed in neat cement slurry and pointed in coloured cement to match with shade of coloured tiles over and including 15 mm thick screed bed in Cement mortar 1: 6 Complete all as specified and directed.
M&L for glazed coloured ceramic joint free tiles ,first quality ( of approved class , colour and design/ shade ) of size 400 x 400 x 8-10mm thick in vertical surfaces, as in dado / skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with shade of coloured tiles, over and including 10 mm thick rendering in cement mortar (1:4), rough finish to receive the tiles complete all as specified and directed.
M&L for glazed coloured ceramic tiles ,first quality ( of approved class , colour and design/ shade ) of size 300 x 200 x 6-7mm thick in vertical surfaces, as in dado / skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with shade of coloured tiles, over and including 10 mm thick rendering in cement mortar (1:4), rough finish to receive the tiles complete all as specified and directed.
S&F wire netting of galvanized steel wire, 1.40 mm dia with mesh size 20 mm as extra reinforcement to RCC members like ceiling, chhajja, beams, column, parapet walls, waist slab etc including all cutting and waste complete all as specified and directed.
M&L for applying one coat of epoxy resin (FAIR BOND EP) on old concrete surface of ceiling and beams, column, chajja, stair case etc @ 0.30 Kg / Sqm including complete removal of rusted portion of reinforcement and preparation of surfaces as per manufacturer's instruction complete and applying 25 mm thick (average thickness) of cement and sand (fine grit) in ration 1:4 mixed with cloride free spray concrete plasterciser (spray crete) as per manufacture instructions with gunniting machine or pressure capacity not less than 5 kg per sqm and finished the surfaces even and smooth in cement morter 1:4 complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
All as per item No.38 above but 6 mm to 8 mm dia complete all as specified and directed.
M&L for preparing new or previously untreated steel & iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide primer complete all as specified and directed.
S & F Galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty wooden beads in squares n. exc. 0.5 sqm in each pane complete all as specified and directed.
S&F 20 mm dia ball brass valves high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs PVC waste pipes of 40/32 mm bore suitable for coupling 40 mm & 32 mm dia, 610 mm long complete all as specified and directed.
.M&L for cement concrete 1:3:6 type C-1 (using 12.5 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, copings, holdfast and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
S&F solid PVC door frame of size 50mmx 47mm made out of 5 mm thick wood grain printed PVC sheet of density not less than 600 Kg/cum reinforced with 19mm x 19mm MS square tube of wall thickness 19 gauge, edges will be painted to match with printed sheet fixing in opening as per specification & drawings shown in section 8 of SSR Part-II 2010 complete all as specified and directed.
S&F mild steel work as in bands, straps, supports or stays for rainwater, Ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three ways straps, plate washers and similar small articles conforming to Fe-290 or E-165 complete all as specified and directed.
S&F factory made 35 mm thick , 2nd class hard wood , rail and style, plain framed, paneled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003 (part-I), kiln seasoned and chemically pressure treated. complete all as specified and directed.
S&F factory made steel windows with side hung shutters including box type hinges with steel handle, and 125 mm MS tower bolt 2 Nos in each leaf and steel peg stay complete without glazing bars, dovetailed or welded complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of solid panel wood grain printed PVC sheet of density not less than 600 kg / cum & 5 mm thick x 15 mm wide PVC sheet beading inside stiles and rails and decorative PVC beading of 10 mm x 10 mm (90 degree) frame made out of MS tubes of 19 gauge thickness and size 40 mm x 20 mm for stiles, top, bottom and lock rails MS frame shall be covered with heat moulded decorative colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of wood grain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement as per specification & drawings shown in section 8 of SSR Part-II 2010 complete all as specified and directed.
S&F 100 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F extruded aluminium alloy handles, cast type, anodised 125 mm size complete all as specified and directed.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framed work and similar works conforming to Fe-290 Gd E-165 complete all as specified and directed.
M&L 50 mm thick cement concrete type C-1, 1:3:6 using 20mm graded stone aggregates as in plinth protection finishing cement concrete even and smooth without using extra cement including making 12 mm wide and in full depth, joints at each corner and at every 3.00 mtr interval filling the same with mastic filling i.e one part of bitumen 85/25 and 3 part of sand complete all as specified and directed.
M&L for 25 mm thick plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in flooring/sub base finished rough to receive floor finishes/screed complete all as specified and directed.
M&L for 40 mm thick (average thickness) cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) for padding on roof surfaces finished fair and even complete all as specified and directed.
S&F in repair chromium plated brass overhead shower rose of size 125 mm dia , fancy type with and including swivel joints , swivel arms and wall flange for fixing with 15 mm pipe complete all as specified and directed. Cat Part No.ITP-2033 of make Plumber or Cat part No.MJN-1260 of make Marc or equivalent model in specified makes as approved by GE.
S&F vitreous china bowl urinal flat back of size 465 x 355x 265 mm, white including grating and union for discharge pipe,and including fixing plugs beading urinal against wall in CM 1:2, securing urinal to plugs with brass screws 60 mm long, pointing around urinal in white cement specified and directed.
S&F in repairs PVC body valveless,syphonic action type, flushing cistern 10 ltr capacity, low level, white, with inlet ball valve and float,and handle including bracket and PVC flush pipe 32 mm dia complete all as specified and directed Cat Part No: .E-8297 of make Parry ware or Cat part No.701 of make Prayag or equivalent model in specified makes as approved by GE.
S&F in repairs vitreous china wash hand basin (flat back) of size 550x400mm with and including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed,and including one no's pillar taps, brass, with capston heads, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts screwed for 15mm bore iron pipe , and MS brackets 2 numbers including cutting for and pinning in ends of brackets complete all as specified and directed. For : Wash hand basin Cat part No.C-0406(CHT) of make Parryware or cat part No.10008 of make Hindware or equivalent model in specified makes as approved by GE. For : Pillar Tap cat part No.MJN 1010 of make Marc or cat part No.EC-0101 of make Plumber or equivlaent model in specified makes as approved by GE.
S&F PVC connection 450 mm long suitable for 15 mm GI pipe with two PTMT nuts & rubber washers complete all as specified and directed. Cat part No.323T of make Prayag or cat part No.4003D of make polytuf or equivalent model in specified makes as approved by GE.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest (excluding flushing cistern and flush pipe) incl providing lime concrete bedding and connecting to flusing cistern and trap & connecting fittings as required and making good to floor, complete all as specified and directed. Cat part No.C-0117 of make Parryware or cat part No.20004 B of make Hindware or equivalent model in specified makes as approved by GE.
S&F in repairs cast iron Trap 'P' or 'S' for WC 100 mm bore fixed with cement joint complete all as specified and directed.
S&F in repair 75 mm dia PVC (SWR) floor trap plain, with grating including jointing to waste pipe with solvent cement and fixed in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified and directed.
S&F in repair PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints fixed on wall etc confirming to IS 13592 complete all as specified and directed.
S&F in repair PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints laid in trenches or in floors etc confirming to IS 13592 complete all as specified and directed.
S&F in repair PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints fixed on wall etc confirming to IS 13592 complete all as specified and directed.
S&F in repair PVC (SWR) bend 110 mm dia any radius as required with oval access door and jointed with approved adhesive complete all as specified & directed.
S&F in repair PVC (SWR) bend 75 mm dia any radius as required with oval access door and jointed with approved adhesive complete all as specified & directed.
S&F in repair PVC (SWR) branch piece,110 mm bore, single (single T) equal or unequal with oval access door and jointed with approved adhesive complete all as specified & directed.
S&F in repair PVC (SWR) branch piece, 75 mm bore, single (single T) equal or unequal with oval access door and jointed with approved adhesive complete all as specified & directed.
S&F PVC (SWR) vent cowl 75 mm dia, jointed with approved adhesive complete all as specified & directed.
S&F Stack clamps for 100 mm bore pipe made out of 50 mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F in repair 0.63 mm thick plain galvanised mild steel sheeting with grade of zinc coating 275 gm as in straight flashing such as crumple joint fixed with mild steel screws by inserting /drilling in rawl/wooden plugs in bldg wall, ceiling, roof including making good disturbed surfaces etc complete all as specified and directed.
All as per item No.76 above but refixing the existing sheet with new mild steel screws by inserting /drilling in rawl/wooden plugs in bldg wall, ceiling, roof including making good disturbed surfaces etc complete all as specified and directed.
M&L for cutting upto a depth of 5 cm into concrete walls and trimming surface as required girth exc 30 cm complete all as specified and directed.
S&F of 25 mm thick preformed bituminous filler board for crumple / expansion joints complete all as specified and directed.
M&L for use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces of concrete complete all as specified and directed.
M&L for use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions shape rectangular or polygonal for fair finished surfaces of concrete Square, complete all as specified and directed.
M&L for applying a coat of zinc chromate primer as cathodic protection complete all as specified and directed.
M&L for applying a coat of Dr. Fixit (Pidilcrete MPB) or equivalent acrylic bonding agent as approved by GE over pre-wetted surface complete all as specified and directed.
M&L for applying a coat of Dr. Fixit Raincoat or equivalent chemical for protective coat as approved by GE a water proofing complete all as specified and directed.
M&L for filling cracks and voids of brick work with non shrink repair compound as per manufacture instruction complete all as specified and directed.
M&L for applying a coat of concrte curing compound (like Concure WB of Fosroc or any other equivlaent brand as approved by GE) as cathodic protection complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:3 with and including water proofing compound as per manufacturer instruction complete all as specified and directed.
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces complete all as specified and directed.
M&L for 50 mm thick cement concrete type B-1, 1:2:4 (20 mm graded stone aggregate) including roughning the surfaces old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed.
M&L for cement concrete type B-2, 1:2:4 (40 mm graded stone aggregate) as in sunken slab & mass concrete complete all as specified and directed.
Taking down carefully existing unserviceable copper / aluminum point wiring of any description & in any position with and including taking out existing unserviceable conduits or battens of any description with sunken boxes/junction boxes and all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc but excluding tube light fittings and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
Material and labour for point wiring with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size all as directed with using new sunken type pressed steel box / terminal boxes for mounting fittings/junction boxes not less than 1.6mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with 3mm thick bakelite laminated sheet, and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
All as per Srl item No 92 here in above but point wiring for for one light point or one fan point controlled by one switch complete all as specified and directed.
All as per Srl item No 92 here in above but point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board.omplete all as specified and directed.
All as per Srl item No 92 here in above but point wiring for 5 pin switch socket outlet, 5 Amps on same board with other switches omplete all as specified and directed.
All as per Srl item No 92 here in above but point wiring for one six pin socket outlet, 15 & 5 Amps (independent) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor omplete all as specified and directed. Notes for item 92 to item 96 here in before : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick bakelitelaminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A' (iii) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade)
Supplying & fixing for piano switch flush type, 5/6 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed.
Supplying & fixing for socket outlet, five pin, 5/6 Amps, flush type, 230 volts AC circuit complete all as specified & directed .
Supplying & fixing for piano switch flush type, 15/16 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed .
Supplying & fixing for socket outlet, multipurpose, three pin, 15/16 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit complete all as specified & directed.
Supplying & fixing for ceiling rose PVC Polycarbonate isolated body 63.5 x 20 mm, three terminals, complete all as specified & directed.
S&F in replacement LED battan surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 20W, luminaire lumens > 2000 lms, system efficiency of > 120 lumens / W, LED of make : Nichia / Cree / Everlite / Eclison / OSRAM / Lumiled, with LED binding as per ANSJ Bin C78377A, Ingress protection IP 20, colour rendering index CRI > 80, temp range 0 to 45 ºC, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 VAC and safety extra low voltage safe level < 60 VDC as per IEC standard with LM 70 & 80 certification complete all as specified Make :- Wipro Model No.LL20-281 - XXX-65AL1 or equivalent of philips / Balaj / Havells
Supplying, fixing in replacement & testing Bulk head , luminaire 13.5 watt LED, internally prewired with and including premium quality diffuser for glarefree light and easy to install snap fit installer complete with all accessories, and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.50 Sqmm and fixing arrangements for fixing the light fitting complete all as specified & directed. Cat Part No:- .LHEXCGP7IN5W013 model ELLIPSE NEO HEXA of make Havells or equivalent model of make Phillips/Bajaj/Wipro as approved by GE.
Supply, fixing, connecting & testing factory made, epoxy powder coated, distribution board (sheet metal encloser) , singe pole and neutral, 4 ways, (Horizontal DB's) ,with metal door and fixed flush to wall and suitable for universal mounting with having copper bus bars of capacity 200 Amps rating, of suitable size , for double door and suitable for using MCB SPN as incomer and SP MCBs out going, conforming to IS : 13032 complete all as specified & directed, ( Note: MCBs shall be measured and paid for separately under appropriate item of Sch ‘A’.
Supply, fixing, connecting & testing factory made, epoxy powder coated, distribution board (sheet metal encloser) , singe pole and neutral, 8 ways, (Horizontal DB's) ,with metal door and fixed flush to wall and suitable for universal mounting with having copper bus bars of capacity 200 Amps rating, of suitable size , for double door and suitable for using MCB, SPN as incomer and MCBs SP as out going, conforming to IS : 13032 complete all as specified & directed, ( Note: MCBs shall be measured and paid for separately under appropriate item of Sch ‘A’.
Supplying & fixing MCB single pole, 6 to 16 Amps (`C’ series ) having current rating 10 KA, 240 volt complete all as specified and directed. Cat part No.4085 90 of make Legrand of equvialent model as specified make as approved by GE.
Supplying & fixing MCB SPN, 32 Amps (`C’ series ) having breaking capacity 10 KA, 240 volt complete all as specified and directed. Cat Part No:- .4086 14 of make Legrand or equivalent model of make Schneider (Acti-9)/L&T/Hager as approved by GE.
Supply, fixing, connecting & testing Exhaust fan heavy duty, CI body single phase 230V, of size 300 mm sweep,1400 rpm with louvered shutters including necessary fixing arrangements on wall with & including bracket nut and bolts and including connecting wire with new 3 core 0.50 Sqmm PVC insulated and sheathed copper conductor cable from ceiling rose and also writing MES No with black paint complete all as specified and directed.
Disconnecting & taking up or down existing unserviceable sub main wiring of copper/aluminium conductor with two run of single core cable with one run of single core earth conductor cable of any description, any size & in any position without taking out existing conduits of any description and M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of dia not less than 20 mm with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor connected to earth dolly complete all as specified and directed. Notes :- (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs)
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing of cable, protection covers/ bricks complete all as specified and directed Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and protection cover/Bricks . (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed .
Removal of surplus excavated soils to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around under ground cables in trenches/ducts for cable protection with layers of sand ( 8 cm deep before laying cable and 15 cm after laying cable ) complete all as specified and directed
S&F brick covering with width equal to length of brick as the mechanical protection to cable with wellburned sub class 'B' laid in trenches flat complete all as specified and directed.
.Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 16 Sqmm 2 core conforming to IS 7098 Part-I or IS 1554 Part-I. complete all as specified and directed.
Supplying and fixing of GI tubing, 40 mm bore, light grade as in sleeving/protection of cable etc laid in trenches/floor or fixed on pole / wall etc. with and including suitable size of MS clamp and nut, bolt ,washer etc complete all as specified and directed
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Messars Maa Devi Construction Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .