Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Not Admitted-Finance 03 GOVIND PURAM EIDGHAH ROAD BIJNOR BIJNOR UTTAR PRADESH 246701 | BIJNOR | UTTAR PRADESH | 246701 | - | Not Admitted-Finance Not qualified for AOC | |
| 3 | Not Admitted-Finance | - | Not Admitted-Finance Not qualified for AOC |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
16 Feb 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DFO
CCF office, social forestry circle indore, IT park square khandwa road
Mist Chamber complete construction work with material related tender
2025_MPFD_400519_1
184
Open Tender
Agricultural or Forestry
Item Wise
25 days
Two different nurseries in Indore and Dewas
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹45,000
CCF office, social forestry circle indore, IT park
26 Feb 2025
4 Feb 2025
17 Feb 2025
4 Feb 2025
16 Feb 2025
4 Feb 2025
13 Feb 2025
Mist Chamber
Mist Chamber Technical Specification Size : 9 x 5 meter Shape : Arch shape Center Height : 4 meter Sidewall Height : 1 meter Height of Polycarbonate Sheet Above Walls : 1.5 meter Works to be done at two different nurseries, one at each nurseries. Evaporative Cooling System 1.5 meter tall with lengthwise evaporative Cellulose complete set cooling pad with all necessary framing material of aluminium required supporting distribution & returning piping, gutters down spout end caps and drip pan, plumbing kit, pump capacity as per requirement. Drilled PVC piping cap, pad retainer, all suspension hardware, metal flashing as required to seal pad to vent opening, 4” thick evaporative. Cooling pad material : Pad construction material, aluminium profiles, tray sides, water distribution tray, cooling media 100mm thick Water storage tank capacity : 1000 liter (Sintex) 40 Mesh Nylon for extra protection from dust, fitted behind pad 1HP water pump should be used in cooling system Civil Works: Structure will be raised on RCC with columns and beams as per requirement, foundation wall of width 20cm for all sides of mist chamber. Wall around the structure should be of at least 1 meter height above ground and thickness of the wall shoud be of 20cm. Filling of base with hard murrum and making it compact such that it remains stable. RCC Floor above murrum base of 5cm thickness. Three platforms should be raised above floor for germination beds with following specifications: • Inner Dimension of germination beds– ▪ Middle bed 7x1x0.20 meter (length x width x depth) ▪ Beds on sides 8x1x0.20 meter (length x width x depth) • Base of germination beds should be of RCC. • Germination beds should be raised on RCC Columns of required numbers. • Height of Platforms not be less than 1 meter • Installation of tiles should be done on the inner and outer walls and top walls of the germination platforms and also on the columns on which ths germination beds are raised. • All walls and columns shoul be plastered with 12mm thickness cement plaster. Structure Frame : • All galvanized iron should be used design as per IS875 standards to withstand wind speed 120 km/h. Complete pre machined structure and cladding with polycarbonate sheet 6 mm thick multiwall UV stabilized material: • All structures, rafters, purlins, trusses should be hot galvanized without welding. All main parts should be hot galvanized. • Galvanised pipes of the structure should be fixed into the RCC columns of the structure with the help of fasteners and RCC. GI Columns pipes should be of thickness 4x4 inch. Base of the arch above column pipes should be made with 4x4 inch GI pipes. • The galvanized iron used in frame should be of major brand. Steel used in RCC should be of major brand . • Door should be fixed for entry in mist chamber Made with aluminium frame and fixed with 6mm polycarbonate sheet. Fixing of UV stabilized Polycarbonate sheet: Polycarbonate sheet of 6 mm thickness should be fixed on GI pipes with heavy duty aluminium profile on both sides. Fogging System : • Hanging fogging system with heavy duty water pump with fourway fogger(22lph), sand filter, screen filter and pressure meter to raise Relative Humidity upto 90%. • Water pump for fogging system should be 3HP and of major brand • All fogging system parts should be of major brand • Screen filter and sand filter should be of major brand Climate Control System : • Two heavy duty exhaust fans of 54 inch outer diameter should be fixed • Electronic climate control system which can monitor and control temperature and humidity. It should maintain chamber climate by contolling chamber equipments like cooling fan, foggers etc. It should have manual and automatic working options. One should be able to set required humidity and temperature with help of control pannel fitted with LCD screen. • Electronic climate control system should control two exhaust fans, fogging system and cooling system with input from temperature and humidity sensor.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .