Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC NO 26 GURU AMARDAS COLONY BHAINSA NAKA SAGAR MADHYA PRADESH 470001 | SAGAR | MADHYA PRADESH | 470001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.9 L+₹2.3 L (11.5%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹23.1 L+₹3.4 L (17.3%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹23.5 L+₹3.8 L (19.5%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹24.1 L+₹4.5 L (22.8%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
₹30.2 L
EMD Value
₹60,400
Closing Date
7 Nov 2019, 6:00 pmClosed
GE(AF)OJHAR
GE(AF)OJHAR
Repair Replacement and Maintenance of internal wiring and Day to Day Maintenance in OMQ, Admin and Tech Area and Repair and Maintenance of Fan and Geyser at AF Stn Deolali
2019_MES_285030_2
8609/E8
Open Tender
Civil Works
Item Rate
270 days
Deolali
As per tender
8 documents required · 8 mandatory
₹500
GE(AF)OJHAR
₹60,400
Yes
5 Mar 2020
23 Oct 2019
9 Nov 2019
23 Oct 2019
7 Nov 2019
26 Oct 2019
23 Oct 2019 - 25 Oct 2019
Amount
Taking down carefully aluminium/copper point wiring (light, fan, socket power etc) on TW batten/PVC casing capping, surface steel/PVC conduit excluding all fitting/fixtures and making good disturbed surfaces of wall/floor/ceiling etc to match the adjoining surfaces all as directed.
M&L for point wiring complete with two single core, PVC insulated, unsheathed, multi stranded bright annealed copper conductor cable, 1.5 Sq.mm 1100 Volts, FR grade drawn through and including heavy duty PVC casing and capping not less than 25 mm width and accessories surface mounted on walls, ceilings etc. on & including PVC box and plate for mounting switches, sockets, regulators etc and one run of 1.5 Sq.mm PVC insulated, unsheathed, multistranded, copper conductor cable FR grade as earth wire and connected to common earth dully complete for the following :-
One light/fan point controlled by one switch
One 3 pin socket out let 5 Amps on same board.
One 3 pin socket out let 5 Amps on independent board.
One bell point controlled by one bell push
All as per Sl item No 02 above but with two runs of 2.5 Sq.mm cable and one run of 1.5 Sq.mm cable as earth wire for one 3 pin socket outlet/power point 15 Amps controlled by one switch.
S&F in repairs Switch piano flush type single pole one way 5 Amp
S&F in repairs switch piano flush type single pole one way 15 Amp
S&F in repairs Bell push flush type 5 Amps.
S&F in repairs Bell, Ding Dong AC 230 Volts single pole.
S&F in repairs Bell multi music type AC 230 Volts single pole.
S&F in repairs Socket out let 2 in 1, 5 pin 5 Amps flush type.
S&F in repairs Socket out let 2in1,3 pin 5 and 15 Amps flush type.
S&F in repairs Lamp holder PVC/polycarbonate insulated body with back plate suitable for batten fittings.
S&F in repairs ceiling rose surface type, PVC/Polycarbonate isulated body size 50x28 mm two to three terminals.
S&F in repairs fan regulator electronic 5step type 2 module sitable for 1200/1400mm sweep.
S&F in repairs fan regulator electronic step type 5 step 1 module suitable for 1200/1400 mm sweep.
S&F in repairs PVC rectangular board 100mm x 100 mm x 50mm deep. Make : Presto Teak/Modi/pressfit
S&F in repairs PVC rectangular board 175mm x 100mm x 50mm deep. Make : Presto Teak./pressfit
S&F in repairs PVC rectangular board 200mm x 150mm x 50mm deep. Make : Presto Plast./pressfit
S&F in repairs PVC rectangular board 250mm x 200mm x 50mm deep. Make : Presto Teak./pressfit
S&F in repairs PVC rectangular board 350mm x 300mm x 50mm deep. Make : Presto Teak./pressfit
Dismantling and taking down u/s main switches/ MCBs/DBs enclosures /electric meter etc and keeping in safe custody either for reuse or for disposal including making good to the disturbed surfaces of wall complete all as specified and as directed by Engr-in-Charge.
Material and labour for fixing with all necessary connections of the following items :-
MCB SP 5 to 30 Amps 240 volts. B series 10 KA
MCB SPN 5 to 30 Amps 240 volts. B series 10 KA
MCB SPN 40 to 63 Amps 240 volts. B series 10 KA
MCB TPN 32 to 63 Amps 415 volts. B series 10 KA
Sheet metal enclosure for DB’s with bus bar, MCB SPN 2 way ,240 volts single door with detachable gland plate.
Sheet metal enclosure for DB’s with bus bar ,MCB SPN 4 way ,240 volts double door with detachable gland plate.
Sheet metal enclosure for DB’s with bus bar , MCB SPN 8 way ,240 volts double door with detachable gland plate.
Sheet metal enclosure for DB’s with bus bar ,MCB SPN 12 way ,240 volts double door with detachable gland plate.
Sheet metal enclosure for DB’s MCB TPN, bus bar , 4 way ,415 volts double door with detachable gland plate.
Sheet metal enclosure for DB’s MCB TPN, bus bar , 4 way ,415 volts double door with detachable gland plate, vertical type.
S&F in repairs sheet metal enclosures distribution board 415 volt, vertical TPN 8 way with provision for DPx160 series MCCB of legrand make or equivalent in L&T as incomer and SP/TP MCB's as outgoing as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface/reccess mounting IP-43 IK-09 protection with the following :- (i) MCCB DP x 160 series thermal magnetic, 25 KA rupturing capacity,125A, 4 pole as incomer-01 No. (ii) MCB SP 6 to 32 Amp,10 KA - 19 Nos. (iii) MCB TP 10-30 Amp,10KA-03 Nos.
S & F in repairs and connecting up LED light fittings 1x18/20 watt 4 feet long complete with LED rode 18/20 watt, spring loaded rotary holder, connector etc. complete and connecting up with and including 23/00.0076 size 3 core copper flexible wire from connector to ceiling rose/adoptor including all necessary fixing arrangements complete. Crompton batten suitable for LED T8 lamp 18/20W DMLN1LT8-16, 1X18/20W and LED rod LT8-20-865-2(20W) or equivalent in Philips/Bajaj/Havells/Wipro ).
S & F in repairs and connecting up LED light fittings 2 feet long complete with LED rod 8/9 watt, spring loaded rotary holder, connector etc. complete and connecting up with and including 23/00.0076 size 3 core copper flexible wire from connector to ceiling rose/adoptor including all necessary fixing arrangements complete. Crompton batten suitable for LED T8 lamp 8/9W DMLN1LT8-8, and LED rod LT8-8-865-2(08W) or equivalent in Philips/Bajaj/Havells/Wipro ).
S&F in repairs decorative oval bulk head edge-lite LED luminaire fittings 1 x 10 W including all necessary electric connection Make: Havells Model No: 860SSYMTOPC or equivalent in Bajaj/ phillips/ wipro/Crompton.
S&F in repairs PVC casing capping 25 mm wide fixed on wall/ ceiling for encasing of existing point wiring/ sub main wiring with and including all fittings and fixures complete all as specified and as directed by Engr-in-Charge.
S&F in repairs PVC casing capping 32 mm wide fixed on wall/ ceiling for encasing of existing point wiring/ sub main wiring with and including all fittings and fixures complete all as specified and as directed by Engr-in-Charge.
S&F in repairs sub main wiring with PVC insulated un armoured heavy duty copper conductor 1100 Volts FR grade 2 single core 2.5Sq.mm cable and one run of 1.5Sqmm copper earth wire for continuous earth fixed on wall/ceiling/floor etc. drawn in suitable size of PVC casing capping/ PVC non metallic conduit complete all as specified and as directed by Engr-in-Charge. NOTE: Two run of 2.5 Sqmm , one run of 1.5 Sqmm and one run of PVC casing capping/ PVC non metallic conduit shall be measured as one unit length.
S&F in repairs sub main wiring with PVC insulated un armoured heavy duty copper conductor 1100 Volts FR grade 2 single core 6 Sq.mm cable and one run of 4 Sqmm copper earth wire for continuous earth fixed on wall/ceiling/floor etc. drawn in in suitable size of PVC casing capping / PVC non metallic conduit complete all as directed. NOTE: Two run of 6 Sqmm , one run of 4 Sqmm and one run of PVC casing capping/ PVC non metallic conduit shall be measured as one unit length.
S&F in repairs Sub main wiring with PVC insulated un armoured heavy duty copper conductor 1100 Volts FR grade 2 single core 4 Sq.mm cable and one run of 2.5 Sqmm copper earth wire for continuous earth fixed on wall/ceiling/floor etc. drawn in in suitable size of PVC casing capping / PVC non metallic conduit complete all as directed. NOTE: Two run of 4 Sqmm , one run of 2.5 Sqmm and one run of PVC casing capping/ PVC non metallic conduit shall be measured as one unit length.
S&F in repairs electronic driver of wattage 9W for LED fitting after disconnecting the fitting carefully from electric supply as specified and directed by Engr-in-Charge.
S&F in repairs electronic driver of wattage 18W for LED fitting after disconnecting the fitting carefully from electric supply as specified and directed by Engr-in-Charge.
Labour only for repairs to existing unserviceable switch board/fittings such as switches, sockets, switch socket combination, lamp holder, sketch light fittings, ceiling rose, hylam sheet/laminated sheets, bell, bell push etc. including rectification of faulty electric circuit; tightening of loose/hanging wires in position at site including identifying defective parts and making serviceable by renewal of damaged/ unserviceable parts with new parts as required and making good disturbed surfaces of wall/ floor/ ceiling etc. complete all as specified and as directed by Engr-in-Charge. (Note:-(i) The following herein under mentioned parts under Serial item Nos 34 to 47 where found unserviceable shall be supplied by the contractor and shall be paid for supply only rates. (ii) Fixing charges shall be deemed to be included in the quoted rates against Sl item No. 33 including cost of minor stores such as screws, clamps, insulation tape, nuts/bolts etc.)
Supply only switch piano flush type single pole one way 5 Amp
Supply only switch piano flush type single pole one way 15 Amp
Supply only bell push flush type 5 Amps.
Supply only bell, Ding Dong AC 230 Volts single pole.
Supply only bell multi music type AC 230 Volts single pole.
Supply only socket out let 2 in 1, 5 pin 5 Amps flush type.
Supply only socket out let 2in1,3 pin 5 and 15 Amps flush type.
Supply only switch socket combination outlet 3 pin 6 Amps 16 Amps 2 in 1 flush type universal.
Supply only switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type universal
Supply only lamp holder PVC/polycarbonate insulated body with back plate suitable for batten fittings.
Supply only lamp holder PVC/polycarbonate insulated body with cord grip cap suitable for pendent fittings.
Supply only ceiling rose surface type, PVC/Polycarbonate isulated body size 50x28 mm two to three terminals.
Supply only fan regulator electronic 5step type 2 module sitable for 1200/1400mm sweep.
Supply only fan regulator electronic step type 5 step 1 module suitable for 1200/1400 mm sweep.
S&F in repairs modular switch 5 Amps SP one way suitable for 230 Volts Make: Anchor Roma
S&F in repairs modular socket 5 Amps SP suitable for 230 Volts Make: Anchor Roma
S&F in repairs modular switch 15 Amps in repairs SP suitable for 230 Volts Make: Anchor Roma
S&F in repairs modular socket 15 Amps SP suitable for 230 Volts Make: Anchor Roma
S&F in repairs modular switch bell push modular type 1 module 06 Amp,240 Volts Make: Anchor Roma
S&F in repairs modular fan regulator electronic solid state with four steps variable speed suitable for ceilling fan of size 900 to 1500mm sweep working on 230 V AC supply with all necessary connections.Make: Anchor Roma
S&F in repairs metal/PVC surface box with inner and outer surface plate suitable for 1 or 2 module
S&F in repairs metal/PVC surface box suitable with inner and outer surface plate for 3 module
S&F in repairs metal/PVC surface box suitable with inner and outer surface plate for 6 module
S&F in repairs metal/PVC surface box suitable with inner and outer surface plate for 8 module
S&F in repairs metal/PVC surface box suitable with inner and outer surface plate for 12 module
S&F in repairs metal/PVC surface box suitable with inner and outer surface plate for 16 module
Labour only for repairs to existing unserviceable FTL/CFL fittings any type, size & capacity, recess/surface mounted at site in existing position including identifying the defective parts and making serviceable complete by renewal of damaged/ unserviceable parts with new parts as required complete all as specified and as directed by Engr-in-Charge. (Note:-(i) The below mentioned parts under SL item No 61 to 79 where found unserviceable shall be supplied by the contractor and shall be paid for supply only rates. (ii) Fixing charges shall be deemed to be included in the quoted rates under Sl item No. 60 including cost of minor stores such as screws, clamps, insulation tape, nuts/bolts etc.)
Supply only electronic ballast 1x36/1x 40 watt, suitable for BJHF 136/140 P PF > 0.95 luminaire of Bajaj Make or equivalent model of Philips/CG/Wipro.
Supply only electronic ballast 2x36/ 2x40 watt, suitable for BJHF 236/240 LHD PF > 0.99 luminaire of Bajaj Make or equivalent model of Philips/CG/Wipro.
Supply only open construction ballast for FTL/ CFL 1x36/1x 40 watt, suitable for BCCB SD 36/40 luminaire of Bajaj Make or equivalent model of Philips/CG/Wipro.
Supply only open construction ballast for FTL/ CFL 1x18/1x 20 watt, suitable for BCCB SD 18/20 luminaire of Bajaj Make or equivalent model of Philips/CG/Wipro.
Supply only open construction ballast for FTL/ CFL 9/11/watt, suitable for BES 9/11 luminaire of Bajaj Make or equivalent model of Philips/CG/Wipro.
Supply only open construction ballast for FTL/ CFL 13/watt, suitable for BES 13 luminaire of Bajaj Make or equivalent model of Philips/CG/Wipro.
Supply only open construction ballast for FTL/ CFL 18/watt, suitable for BES 18 luminaire of Bajaj Make or equivalent model of Philips/CG/Wipro.
Supply only electronic ballast 1x9/11/13 watt, suitable for BJHF 109/11/13 PF > 0.9 luminaire of Bajaj Make or equivalent model of Philips/CG/Wipro.
Supply only electronic ballast 1x18 watt, suitable for BJHF 118 PF > 0.9 luminaire of Bajaj Make or equivalent model of Philips/CG/Wipro.
Supply only electronic ballast 1x18/1x 20 watt, suitable for BJHF 118/120 P PF > 0.95 luminaire of Bajaj Make or equivalent model of Philips/CG/Wipro.
Supply only starter 40/20 watt 230 volts. Make : Philips/Bajaj.
Supply only starter 40/20 watt 110 volts. Make : Philips/Bajaj.
Supply only bipin holder with suitable basesuitable for flouroscent tube light fittings as per sample suitable for 40/36/20/18/28 watt
Supply only non retrofit CFL holder 2 pin for PL lamps 9/11/13/18 watt
Supply only non retrofit CFL holder 4 pin for CFL lamps 18/36 watt
Supply only non retrofit CFL Lamps 2 pin suitable for 9/11 watts. Make Philips/Bajaj/Crompton
Supply only non retrofit CFL Lamps 2 pin suitable for 13/18 watts . Make Philips/Bajaj/Crompton
Supply only non retrofit CFL Lamps 4 pin suitable for 36 watts . Make Philips/Bajaj/Crompton
Supply only retrofit LED rod 4 feet suitable for 18/20 watts fittings . Make Philips/Bajaj/Crompton LT8-20-865-2
Disconnect and insulate electric supply wire and taking down carefully ceiling/ exhaust/cabin/wall fan of any make and sweep dismantlling blades, check for repairs required including replacement of flexible PVC insulated copper conductor of size 0.75 sqmm 3 core and rubber bushes all as directed by Engr-in-Charge. (Note: Repairs/ Replacement of spares shall be carried under appropriate items)
Hanging only ceiling fans of any make and sweep connecting the complete with & including provision of copper conductor cord 3 core PVC insulated and sheathed from ceiling rose to fan connector and testing all as directed by Engr-in-Charge. (Note: The fan shall be fitted with new set of clamps, rubber shackle split pins and top and bottom nut bolts etc. and rate for the same is deemed to be included in this item)
Hanging/fixing only exhaust/cabin/wall fan of any make or sweep connecting up complete with and including provision of copper conductor cord 3 core PVC insulated and sheathed from ceiling rose to fan connector & testing all as directed by Engr-in-Charge. (Note: The fan shall be fitted with new set of washers, nuts, rubber packing etc. and rate for the same is deemed to be included in this item)
Opening of any type of fan for checking the bearing, bushes and carrying out maintenance such as greasing, oiling and reassembling complete or for rewinding, but including scrapping the old existing paint and painting with two coats of synthetic enamel paint over one coat of red oxide primer, painting the MES No. replacement of flexible cord size 23/0.0076, and rubber bushes etc all as directed by Engineer-in-Charge.
(a) celing fan 1200 mm sweep
(b) Exhaust fan 300/380/450mm sweep
Opening up of fan motor of fan, cleaning stator,rotor, cleaning of all parts greasing oiling of bushes and bearing reassembling and testing for smooth functioning all as directed by Engr in charge
(a) celing fan 1200 mm sweep
(b) Exhaust fan 300/380/450mm sweep
M & L for removing the burnt winding and rewinding the fan with super enamelled copper winding wire of suitable gauge, insulating, putting sleeves etc complete all as specified and directed by Engineer-in-Charge for
(a) celing fan 1200 mm sweep
(b) Exhaust fan 300mm sweep
(c ) Exhaust fan 375 mm sweep
Labour charges for machine work enlargement of bushing housing to house bearing 6201 in place of bushing in modification for longer services.
S&F fan clamp assembly consisting of nut, bolts, washers and split pin alongwith suitable size rubber real for mounting of fan down rod all as directed.
S&F insulated copper flexible conductor 3 core 1 sqmm.
S&F capacitor for ceiling fan of 2.5 MFD. Make: Usha/EPCOS/Priya.
S&Fin repairs ball bearing of size 6201 suitable for fans
S&Fin repairs ball bearing of size 6202 suitable for fans
S&F in repairs louvers & shutters complete for exhaust fan of size 380 mm sweep.
Supply only LED tubelight with very high efficacy suited for installation in existing T-8 tubelight (10W)
S&F in repairs ceiling light fittings 36W LED energy saving, environmental friendly long life and accessories fixed false ceiling 60 cm x 60 cm in size including connection with PVC copper 1.5 sqmm 3 core cable etc complete all as directed. Make crompton Model No LCTLRNI-FO-36-CDL or equivalent in Phillips, Havells, Wipro as approved by GE
S&Fin repairs weather proof, anti corrosion wall/ceiling mounted, decorative, round shape aluminium housing suitable for up to 1x15 watt LED fitting complete and connecting up with and including 23/00.0076 size 3 core copper flexible wire from connector to ceiling rose/adoptor including all necessary fixing arrangements complete. Make:- Havells DLS 15W LED 840S or equivalent in Cromton Greaves/Philips/Bajaj/
S&F in repairs 3 phase DOL starter suitable for 3 phase exhaust fan MK1 relay range 11-18 amp 415 volts, 50 Hz, cat No SS96211 including backelite/fibre sheet of thickness 3 mm in required size including necessary fixing MS screws, nuts, washers, etc all specified and directed by engineer in charge
Taking down exhaust fan of 3 phase, any type from hangers/storage shed of 14 mtr high from wall, then dismantling blades and keeping in safe custody for carrying out maintenance and refixing back in position after repairs all as specified and directed by Engineer in charge
M&L for checking the bearing, bushes and carrying out maintenance such as greasing, oiling etc. for exhaust fan 900 mm sweep all as specified and as directed by the Engineer in charge.
M&L for removing the burnt winding and rewinding the exhaust fan with super enamelled copper winding wire of 36 gauge, insulating putting sleeves etc. complete for 900 mm sweep exhaust fans all as specified and as directed by the Engineer in charge
Taking down and dismantling unserviceable geyser carefully, opening complete, replacement of worn out parts, rectify the leakage, if any, cleaning the geyser and making it serviceable and refixing the same after painting with one coat of spray painting including writting MES no with black paint there after necessary testing complete all as directed. (Note:- Rate shall be including of all other minor spares required for smooth functioning of geyser. Geyser element, thermostat & flexible wire PVC insulated will be measured and paid separately.)
Supply only heating element triangular base or as per sample for geyser of following capacities
(a) 2 KW capacity
(b) 1.5 KW capacity
(c) 1.0 KW capacity
S&F in repairs thermostat switch for water heater 40 degree centigrade to 90 degree centigrade all as directed by Engr-in-Charge.
SHRI SULAI ELECTRICALS
Paras Electricals
Kedar Electricals
SIDDHIVINAYAK ENTERPRISES
M/s.NIKI ENTERPRISES
sapana enterprises
MAHIMA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .