Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 LAccepted-AOC NULL | 1 | Accepted-AOC ok | |
| 2 | 2₹1.7 L+₹2,280 (1.32%)Rejected-Finance 01 SARAI BEERBHADRA BIR BHADRA ROAD NEAR JMS COACHING CENTER PRATAPGARH UTTAR PRADESH 230502 | PRATAPGARH | UTTAR PRADESH | 230502 | 2 | Rejected-Finance Higher Than the lowest one | |
| 3 | 3₹1.8 L+₹4,562 (2.64%)Rejected-Finance | 3 | Rejected-Finance Higher Than the lowest one |
Tender Value
₹1.8 L
EMD Value
₹3,900
Closing Date
1 Dec 2021, 2:00 pmClosed
Executive Engineer Electrical Najafgarh Zone
SOUTH DELHI MUNICIPAL CORPORAIONOFFICE OF THE EXECUTIVE ENGINEER ELECT NGZROOM NO -219, II ND FLOOR, ZONAL OFFICE BUILDING, DHANSA STAND , NAJAFGARH, NEW DELHI-110043
Construction of Toilet Block (12 Seats,1CWSN,12 Urinal) in SDMC Pry School Khaira No. 2 ,ward 43S/Najafgarh Zone. Subhead P/O EI and Fans.
2021_SDMC_95885_4
EE/Elect/Najafgarh Zone /2021-22/ 24
Open Tender
Electrical Works
Item Rate
60 days
Najfgarh Zone SDMC
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹3,900
Yes
5 Jan 2023
26 Nov 2021
2 Dec 2021
26 Nov 2021
1 Dec 2021
26 Nov 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, modular switch,modular plate,suitable GI Box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required..2x2.5 sq.mm +1x2.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required. 2x 4 sq. mm + 1 x 4 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface / recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connections etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Installation of exhaust fan in the existing opening including making good the damage,connection,testing,commissioning etc.as required.(a) Up to 450 mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a)Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(b)Double Pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required .25A
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required. Up to 35 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq.mm ( Clamped with 1 mm thick saddle )
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm and ID-51 mm nominal)
Supply of XLPE insulated and PVC sheathed Al. conductor armoured cable 1.1 KV grade confirming to IS 7098 as required.( a ) 2x10 sq.mm
Supply of 12'' (300mm)sweep 1400 rpm exhaust fan heavy duty complete with shutters blades etc as reqd
S.I.T.C LED tube type luminaire 20 watt rating complete with extruted alluminium batten prewired with high efficient LED with the following specifications.(A) Total system wattage 20 watt+/- 5% ,(B) Luminous efficiency >= 95 Lumens/watt, © Power factor >= 0.95
S.I.T.Cof 150 W LED flood light luminiare fitted with lens made of pressure die cast aluminium housing &toughened glass cover complete with the following specification as required (b)Total system voltage =150 watt +/-5% (c) Luminiare Efficiency >=100 Lm/w (d) Power Factor >=0.95 ( e) Protection Class - IP -66
P & F of Hot Press Sheet Moulded Compound (SMC),fire retardant (Temp. resistanceup to 200 deg.C),IP-55 weatherproof pole box of inner dimension 200 mmx160 mmx98 mm complete with suitable arrangement for fixing of 2 nos.of 6 to 32 amp single pole MCB &63 A double pole isolator(MCB/Isolator exluded )with neutral link duly shorting on DIN channelwith 2 nos.of clamps with SS back plate of suitable size with danger monogram & SDMC property printed on the cover etc. as required
Supply of 9/10watt LED retrofit Lampsuitable for B22 Holder
Supply of LED tube type luminaire 20 watt rating complete with polycarbonate housing batten inegrated electronic driver prewired with high efficient LED with the following specifications.(A) Total system wattage 20 watt+/- 5% ,(B) Luminous efficiency >= 95 Lumens/watt, © Power factor >= 0.95
S.P. 15/16 amps, one way modular switch, ISI marked
6 pin 15/16 amps modular socket outlet, ISI marked
YASH ENTERPRISES
NEERAJ ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .