Loading…
Loading…
Tender ID
Tender Value
₹3.3 Cr
EMD Value
₹3.1 L
Closing Date
23 Apr 2026, 3:00 pmClosed
Provision of new COP on uncovered portion of platform and replacement of damaged valley gutters and down take pipes in section CSMT-CLA Byculla : - Shifting of crossover 108 to relax existing PSR 60 Kmph.
CR-BB-SNT-SOUTH-2026~CR
CR-BB-SNT-SOUTH-2026
Open
Works - General
12 Months
Mumbai, Maharashtra
₹0
₹3.1 L
23 Apr 2026
24 Mar 2026
9 Apr 2026
"Supply of Digital Axle Counter Multi section type complete sysem including the Central Evaluator and final track clearance relay for each secton, Reset boxes, LV boxes, All track side units with detection point complete assembly & fixing arrangement for each detection point, clamps deflector for either side of each detection points, monitoring console for monitoring all the DPs at a time installed at a station/ RH/IBH etc. with all other accessories fully wired and fully equipped as per RDSO specification No.RDSO/ SPN/176/2013 (ver.3) or latest and manufacturers 01 specification. The equipment must also include the following : a) System must have remote monitoring and health diagnostics feature as per RDSO specification. b) Surge protection device. c) 20% spare slots for the both detection heads and track section in the evaluator for future and emergenc provision. Each set also consisting of a) Double rail contact of standard length of cable as per site requirement and mounting accessories - Equal to no. of DP. b) Deflectors to safeguard Rail Contact will be TWICE the no. of DPs. c) Protecting tube from DP to railhead as per requirement. d) Diagnostic PC as per specification and other accessories (as per Annexure-VI) e) Pre-wired cabinet/rack no. as per site requirement. f) 6 Nos. Electrostatic Discharge Wrist Band for cards/ modules protection. (Inspection Agency-Consignee)" Above/
"Supply of Digital Axle Counter Multi section type complete sysem including the Central Evaluator and final track clearance relay for each secton, Reset boxes, LV boxes, All track side units with detection point complete assembly & fixing arrangement for each detection point, clamps deflector for either side of each detection points, monitoring console for monitoring all the DPs at a time installed at a station/ RH/IBH etc. with all other accessories fully wired and fully equipped as per RDSO specification No.RDSO/ SPN/176/2013 (ver.3) or latest and manufacturers specification. The equipment must also include the following : a) System must have remote monitoring and health diagnostics feature as per RDSO specification. b) Surge protection device. c) 20% spare slots for the both detection heads and track section in the evaluator for future and emergenc provision. Each set also consisting of a) Double rail contact of standard length of cable as per site requirement and mounting accessories - Equal to no. of DP. b) Deflectors to safeguard Rail Contact will be TWICE the no. of DPs. c) Protecting tube from DP to railhead as per requirement. d) Diagnostic PC as per specification and other accessories (as per Annexure-VI) e) Pre-wired cabinet/rack no. as per site requirement. f) 6 Nos. Electrostatic Discharge Wrist Band for cards/ modules protection. (Inspection Agency-Consignee)" Above/
Item Breakup - A1-SOR ITEM
Supply of Main Signal Post 140 mm outer dia Numbers 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection Agency- Consignee)
Supply of Main Signal Post 140 mm outer dia Numbers 5.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection Agency- Consignee)
Supply of Cast Iron Main signal surface base Numbers 140mm as per spec No IRS S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg. No. SA- 23156(Adv), SA-23153 (Adv) & SA-23150 (Adv) Alt. 1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C. Rly practice(Inspection Agency-Consignee)
OFF set bracket 5-1/2 " to suit 140 mm dia CLS Numbers Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg.No.SA- 23080 for Signals & Routes(Inspection Agency- Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Supply of Bond Plates suitable for terminating Set track lead connections of AFTC on rail. It consists of tapered stainless steel bolts, nuts, check nuts, washers, L-shaped plate etc., as per Drg.No.RST 11630. Each set of bond plates should consist of (i) SS Taper pins - 8 nos. (ii) SS M6 nuts - 20 nos. (iii) SS M6 plane washers - 32 nos. (iv) Spring washer - 8 nos. (v) Nylon nuts - 8 nos. (vi) S.S.hex bolts M6x15 - 2 nos. (vii) Track circuit cable plates - 4 nos. Supply of all above items would costitute one set. (Inspection Agency-Consignee) Total 161619.36
Item Breakup - A2-SOR ITEM
Supply of Indoor Jumper Wire of various colour Kilometre as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amd.3) or latest.(Inspection Agency-Consignee)
Supply of Indoor Jumper Wire ATC 1 x 1 mm Kilometre dia. conforming to IRS 76/89 (Amd.3) or latest. (Inspection Agency-Consignee)
Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Kilometre B r o w n , Black, White as per site engineer instruction) finolex/polycab/delton make. IRS S- 76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. (Inspection Agency-Consignee)
Supply of PVC flexible copper cable single core Kilometre multistrand 1 x 25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection Agency-Consignee)
Supply of Point Group RRI, Siemens (No.RSSK Numbers 3515/19) or functional equivalent without base plates.(Inspection Agency-Consignee)
Supply of Time Element Relay (Clock work Numbers type) AG timer Siemens Make (No RSSK 30/0052) or GIC make or functional equivalent. (Inspection Agency-Consignee)
Supply of Key Lock Relay with different ward Numbers combinations (Three extra set of ward plate for Point Machine to be supplied with each relay). Siemens Make working on 60V DC/24V DC or functional equivalent without base plates. RDSO/SPN/219/ 2016 Version 1.0 d 1(Inspection Agency-Consignee)
Supply of Plug In type Relay Metal to Metal type Numbers neutral relay mini groups (Non AC Immunised) Siemens make (No. RSSK 30/0011) (Ref. IRS:S46/74 with Amd. 1 & firms specification) or functional equivalent without base plates.Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. (Inspection Agency-Consignee)
Supply of Domino units with cover plate as per Numbers approved panel diagram, each of size 54 x 34mm completely wired up similar to Siemens make. Each domino units should have all the 15 contact terminals wired up.(Inspection Agency- Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Resin cored wire as per specification No. Kg IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement.(Inspection Agency- Consignee)
Lacing thread rolls, black, wax coated (100 Numbers mtrs).(Inspection Agency-Consignee)
Supply of Main Signal Post 140 mm outer dia Numbers 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection Agency- Consignee)
Supply of Shunt Signal Post with Base (GI Pipe Numbers of 80 mm Dia of min. 1 meter length.). (Inspection Agency-Consignee)
Supply of Cast Iron Main signal surface base Numbers 140mm as per spec No IRS S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg. No. SA- 23156(Adv), SA-23153 (Adv) & SA-23150 (Adv) Alt. 1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C. Rly practice(Inspection Agency-Consignee)
Supply of Cast iron Shunt signal surface base Numbers 80 mm as per spec No.IRS S 10 and Drg No.2011/M with latest amendments, as per RDSO Drg No. SA-23156/Drg.No.RST/11413 as per extent C.Rly practice(Inspection Agency- Consignee)
Supply of Signal No.plates. as per Drg No RST- Numbers 11393 / SK-842 or latest(Inspection Agency- Consignee)
OFF set bracket 5-1/2 " to suit 140 mm dia CLS Numbers Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg.No.SA- 23080 for Signals & Routes(Inspection Agency- Consignee)
Supply of A/AG/C/P/G/IB Board as per Drg. RST- Numbers 11444/1(A), RDSO Drg No SA 23460(AG), SA- 23461©, RST-11445. SA 23456(P), SA 23477(G) & SA 23476-77(IB) as applicable respectively with Latest Amendment. (Inspection Agency-Consignee)
Supply of "4 Aspect" Signal Unit in FRP body Numbers without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post Saves pigment finish on the back side of the end inside. White Pigment finish inside the 4 aspect unit to avoid any extra paint cost.(Inspection Agency-Consignee)
Supply of Shunt Signal Position Light Type FRP Numbers complete as per RDSO Specification No.RDSO/SPN/ 194/2006/Rev.2.0 or latest with Off set bracket 3-1/2" to be fitted on 140 mm post drawing No. SA 23840(Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses, lamp, lamp holder, and to suit LED Signal lamps. (Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Supply of "Calling On" Signal Unit in FRP body Numbers without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED sigal Lamps. (Inspection Agency-Consignee)
Supply of William stretcher nylon insulation set Set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendements .(Inspection Agency-Consignee)
Supply of Tongue attachment nylon insulation Set set consisting of one insulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST-10692(Inspection Agency- Consignee)
Supply Gauge Tie plate nylon insulation as per Set RDSO drg No: T- 10372 Alt2, T- 10368, T- 10371 Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with amendement 01 or latest amendements. (Inspection Agency-Consignee)
Supply of GI bend pipe, 'B' class, 50mm dia for Numbers cable entry in point machines, alongwith required fixing arrangements as per standard practice on Central Railway. As per Drg No. RST.11835.(Inspection Agency-Consignee)
Supply of Point Machine Raised Bracket FRP Numbers make with cover as per Drg No.SK-846. (Inspection Agency-Consignee)
Supply of RCC pipes half round of size 150mm Numbers dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection Agency-Consignee)
Supply of RCC pipes half round of size 300mm Numbers dia outer and 250 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection Agency-Consignee) Total 1030067.77
Item Breakup - A3-SOR ITEM
Supply of Indoor Jumper Wire of various colour Kilometre as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amd.3) or latest.(Inspection Agency-Consignee)
Supply of Indoor Jumper Wire ATC 1 x 1 mm Kilometre dia. conforming to IRS 76/89 (Amd.3) or latest. (Inspection Agency-Consignee)
Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Kilometre B r o w n , Black, White as per site engineer instruction) finolex/polycab/delton make. IRS S- 76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. (Inspection Agency-Consignee)
Supply of PVC flexible copper cable single core Kilometre multistrand 1 x 25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection Agency-Consignee)
Supply of Point Group RRI, Siemens (No.RSSK Numbers 3515/19) or functional equivalent without base plates.(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Supply of Time Element Relay (Clock work Numbers type) AG timer Siemens Make (No RSSK 30/0052) or GIC make or functional equivalent. (Inspection Agency-Consignee)
Supply of Key Lock Relay with different ward Numbers combinations (Three extra set of ward plate for Point Machine to be supplied with each relay). Siemens Make working on 60V DC/24V DC or functional equivalent without base plates. RDSO/SPN/219/ 2016 Version 1.0 d 1(Inspection Agency-Consignee)
Supply of Plug In type Relay Metal to Metal type Numbers neutral relay mini groups (Non AC Immunised) Siemens make (No. RSSK 30/0011) (Ref. IRS:S46/74 with Amd. 1 & firms specification) or functional equivalent without base plates.Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. (Inspection Agency-Consignee)
Supply of Plug In type Relay Interlocked Numbers Siemens make (No. RSSK 30/0012) or functional equivalant (Ref. IRS:S46/74 with Amd. 1 & firms specification). Contact cofiguration to be specified by Engineer incharge..(Inspection Agency-Consignee)
Supply of Metal-To-Metal Universal LED type Numbers E C R Siemens make (type A-RT-RG-A064) or functional equivalent without base plate, should be suitable for working with LED based signal lighting unit. IRS:S:46 & STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amd.1.(Inspection Agency-Consignee)
Supply of Domino units with cover plate as per Numbers approved panel diagram, each of size 54 x 34mm completely wired up similar to Siemens make. Each domino units should have all the 15 contact terminals wired up.(Inspection Agency- Consignee)
Supply of Resisters, condensers, Diodes, LEDs Lot and lugs alongwith bracket and mounting arrangement as per standard Annexure-V of Central Railway.(Inspection Agency-Consignee)
Resin cored wire as per specification No. Kg IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement.(Inspection Agency- Consignee)
Lacing thread rolls, black, wax coated (100 Numbers mtrs).(Inspection Agency-Consignee)
Supply of Main Signal Post 140 mm outer dia Numbers 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection Agency- Consignee)
Supply of Main Signal Post 140 mm outer dia Numbers 5.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection Agency- Consignee)
Supply of Shunt Signal Post with Base (GI Pipe Numbers of 80 mm Dia of min. 1 meter length.). (Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Supply of Cast Iron Main signal surface base Numbers 140mm as per spec No IRS S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg. No. SA- 23156(Adv), SA-23153 (Adv) & SA-23150 (Adv) Alt. 1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C. Rly practice(Inspection Agency-Consignee)
Supply of Cast iron Shunt signal surface base Numbers 80 mm as per spec No.IRS S 10 and Drg No.2011/M with latest amendments, as per RDSO Drg No. SA-23156/Drg.No.RST/11413 as per extent C.Rly practice(Inspection Agency- Consignee)
Supply of Signal No.plates. as per Drg No RST- Numbers 11393 / SK-842 or latest(Inspection Agency- Consignee)
OFF set bracket 5-1/2 " to suit 140 mm dia CLS Numbers Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg.No.SA- 23080 for Signals & Routes(Inspection Agency- Consignee)
Supply of A/AG/C/P/G/IB Board as per Drg. RST- Numbers 11444/1(A), RDSO Drg No SA 23460(AG), SA- 23461©, RST-11445. SA 23456(P), SA 23477(G) & SA 23476-77(IB) as applicable respectively with Latest Amendment. (Inspection Agency-Consignee)
Supply of "4 Aspect" Signal Unit in FRP body Numbers without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post Saves pigment finish on the back side of the end inside. White Pigment finish inside the 4 aspect unit to avoid any extra paint cost.(Inspection Agency-Consignee)
Supply of Shunt Signal Position Light Type FRP Numbers complete as per RDSO Specification No.RDSO/SPN/ 194/2006/Rev.2.0 or latest with Off set bracket 3-1/2" to be fitted on 140 mm post drawing No. SA 23840(Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses, lamp, lamp holder, and to suit LED Signal lamps. (Inspection Agency-Consignee)
Supply of "Calling On" Signal Unit in FRP body Numbers without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED sigal Lamps. (Inspection Agency-Consignee)
Supply of Phenolic 10mm thick sheet, grade P3 Numbers in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995.(Inspection Agency- Consignee)
Supply of ARA Terminal blocks with links made Numbers 1400.00 of PBT Specn No.IRS/75/2006(Rev-2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4, SA-23745 Alt.5, SA-23746, SA-23748 Alt.4 & SA-23756A Alt.3.(Inspection Agency- Consignee)
Supply of Tik-tak, piano type switches,5 A (as Numbers per IS Specification).(Inspection Agency- Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Supply of three pole plug and socket 5 Amp (as Numbers per IS Specification).(Inspection Agency- Consignee)
Supply of Lamp 110V/24W, 2 Pin for Loc. Numbers (Inspection Agency-Consignee)
Supply of Electronic Timers for DAC reset Numbers arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC (642XA programmable electronic timer switch) make. (Inspection Agency-Consignee)
Supply of William stretcher nylon insulation set Set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendements .(Inspection Agency-Consignee)
Supply of Tongue attachment nylon insulation Set set consisting of one insulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST-10692(Inspection Agency- Consignee)
Supply Gauge Tie plate nylon insulation as per Set RDSO drg No: T- 10372 Alt2, T- 10368, T- 10371 Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with amendement 01 or latest amendements. (Inspection Agency-Consignee)
Supply of GI bend pipe, 'B' class, 50mm dia for Numbers cable entry in point machines, alongwith required fixing arrangements as per standard practice on Central Railway. As per Drg No. RST.11835.(Inspection Agency-Consignee)
Supply of Point Machine Raised Bracket FRP Numbers make with cover as per Drg No.SK-846. (Inspection Agency-Consignee)
Supply of RCC pipes half round of size 150mm Numbers dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection Agency-Consignee)
Supply of RCC pipes half round of size 300mm Numbers dia outer and 250 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection Agency-Consignee) Total 1489400.48
Item Breakup - A4-SOR ITEM
Supply of Indoor Jumper Wire of various colour Kilometre as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amd.3) or latest.(Inspection Agency-Consignee)
Supply of Indoor Jumper Wire ATC 1 x 1 mm Kilometre dia. conforming to IRS 76/89 (Amd.3) or latest. (Inspection Agency-Consignee)
Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Kilometre B r o w n , Black, White as per site engineer instruction) finolex/polycab/delton make. IRS S- 76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. (Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Supply of PVC flexible copper cable single core Kilometre multistrand 1 x 25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection Agency-Consignee)
Supply of Point Group RRI, Siemens (No.RSSK Numbers 3515/19) or functional equivalent without base plates.(Inspection Agency-Consignee)
Supply of Time Element Relay (Clock work Numbers type) AG timer Siemens Make (No RSSK 30/0052) or GIC make or functional equivalent. (Inspection Agency-Consignee)
Supply of Key Lock Relay with different ward Numbers combinations (Three extra set of ward plate for Point Machine to be supplied with each relay). Siemens Make working on 60V DC/24V DC or functional equivalent without base plates. RDSO/SPN/219/ 2016 Version 1.0 d 1(Inspection Agency-Consignee)
Supply of Plug In type Relay Metal to Metal type Numbers neutral relay mini groups (Non AC Immunised) Siemens make (No. RSSK 30/0011) (Ref. IRS:S46/74 with Amd. 1 & firms specification) or functional equivalent without base plates.Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. (Inspection Agency-Consignee)
Supply of Plug In type Relay Interlocked Numbers Siemens make (No. RSSK 30/0012) or functional equivalant (Ref. IRS:S46/74 with Amd. 1 & firms specification). Contact cofiguration to be specified by Engineer incharge..(Inspection Agency-Consignee)
Supply of Metal-To-Metal Universal LED type Numbers E C R Siemens make (type A-RT-RG-A064) or functional equivalent without base plate, should be suitable for working with LED based signal lighting unit. IRS:S:46 & STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amd.1.(Inspection Agency-Consignee)
Supply of Domino units with cover plate as per Numbers approved panel diagram, each of size 54 x 34mm completely wired up similar to Siemens make. Each domino units should have all the 15 contact terminals wired up.(Inspection Agency- Consignee)
Supply of Resisters, condensers, Diodes, LEDs Lot and lugs alongwith bracket and mounting arrangement as per standard Annexure-V of Central Railway.(Inspection Agency-Consignee)
Resin cored wire as per specification No. Kg IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement.(Inspection Agency- Consignee)
Lacing thread rolls, black, wax coated (100 Numbers mtrs).(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Supply of Main Signal Post 140 mm outer dia Numbers 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection Agency- Consignee)
Supply of Shunt Signal Post with Base (GI Pipe Numbers of 80 mm Dia of min. 1 meter length.). (Inspection Agency-Consignee)
Supply of Cast Iron Main signal surface base Numbers 140mm as per spec No IRS S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg. No. SA- 23156(Adv), SA-23153 (Adv) & SA-23150 (Adv) Alt. 1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C. Rly practice(Inspection Agency-Consignee)
Supply of Cast iron Shunt signal surface base Numbers 80 mm as per spec No.IRS S 10 and Drg No.2011/M with latest amendments, as per RDSO Drg No. SA-23156/Drg.No.RST/11413 as per extent C.Rly practice(Inspection Agency- Consignee)
Supply of Signal No.plates. as per Drg No RST- Numbers 11393 / SK-842 or latest(Inspection Agency- Consignee)
OFF set bracket 5-1/2 " to suit 140 mm dia CLS Numbers Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg.No.SA- 23080 for Signals & Routes(Inspection Agency- Consignee)
Supply of A/AG/C/P/G/IB Board as per Drg. RST- Numbers 11444/1(A), RDSO Drg No SA 23460(AG), SA- 23461©, RST-11445. SA 23456(P), SA 23477(G) & SA 23476-77(IB) as applicable respectively with Latest Amendment. (Inspection Agency-Consignee)
Supply of "4 Aspect" Signal Unit in FRP body Numbers without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post Saves pigment finish on the back side of the end inside. White Pigment finish inside the 4 aspect unit to avoid any extra paint cost.(Inspection Agency-Consignee)
Supply of Shunt Signal Position Light Type FRP Numbers complete as per RDSO Specification No.RDSO/SPN/ 194/2006/Rev.2.0 or latest with Off set bracket 3-1/2" to be fitted on 140 mm post drawing No. SA 23840(Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses, lamp, lamp holder, and to suit LED Signal lamps. (Inspection Agency-Consignee)
Supply of "Calling On" Signal Unit in FRP body Numbers without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED sigal Lamps. (Inspection Agency-Consignee)
Supply of Phenolic 10mm thick sheet, grade P3 Numbers in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995.(Inspection Agency- Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Supply of ARA Terminal blocks with links made Numbers of PBT Specn No.IRS/75/2006(Rev-2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4, SA-23745 Alt.5, SA-23746, SA-23748 Alt.4 & SA-23756A Alt.3.(Inspection Agency- Consignee)
Supply of Tik-tak, piano type switches,5 A (as Numbers per IS Specification).(Inspection Agency- Consignee)
Supply of three pole plug and socket 5 Amp (as Numbers per IS Specification).(Inspection Agency- Consignee)
Supply of Lamp 110V/24W, 2 Pin for Loc. Numbers (Inspection Agency-Consignee)
Supply of Electronic Timers for DAC reset Numbers arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC (642XA programmable electronic timer switch) make. (Inspection Agency-Consignee)
Supply of William stretcher nylon insulation set Set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendements .(Inspection Agency-Consignee)
Supply of Tongue attachment nylon insulation Set set consisting of one insulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST-10692(Inspection Agency- Consignee)
Supply Gauge Tie plate nylon insulation as per Set RDSO drg No: T- 10372 Alt2, T- 10368, T- 10371 Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with amendement 01 or latest amendements. (Inspection Agency-Consignee)
Supply of GI bend pipe, 'B' class, 50mm dia for Numbers cable entry in point machines, alongwith required fixing arrangements as per standard practice on Central Railway. As per Drg No. RST.11835.(Inspection Agency-Consignee)
Supply of Point Machine Raised Bracket FRP Numbers make with cover as per Drg No.SK-846. (Inspection Agency-Consignee)
Supply of RCC pipes half round of size 150mm Numbers dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection Agency-Consignee)
Supply of RCC pipes half round of size 300mm Numbers dia outer and 250 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection Agency-Consignee) Total 1387660.65
Item Breakup - A5-SOR ITEM
Supply of Main Signal Post 140 mm outer dia Numbers 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection Agency- Consignee)
Supply of Main Signal Post 140 mm outer dia Numbers 5.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection Agency- Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Supply of Cast Iron Main signal surface base Numbers 140mm as per spec No IRS S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg. No. SA- 23156(Adv), SA-23153 (Adv) & SA-23150 (Adv) Alt. 1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C. Rly practice(Inspection Agency-Consignee)
OFF set bracket 5-1/2 " to suit 140 mm dia CLS Numbers Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg.No.SA- 23080 for Signals & Routes(Inspection Agency- Consignee)
Supply of Bond Plates suitable for terminating Set track lead connections of AFTC on rail. It consists of tapered stainless steel bolts, nuts, check nuts, washers, L-shaped plate etc., as per Drg.No.RST 11630. Each set of bond plates should consist of (i) SS Taper pins - 8 nos. (ii) SS M6 nuts - 20 nos. (iii) SS M6 plane washers - 32 nos. (iv) Spring washer - 8 nos. (v) Nylon nuts - 8 nos. (vi) S.S.hex bolts M6x15 - 2 nos. (vii) Track circuit cable plates - 4 nos. Supply of all above items would costitute one set. (Inspection Agency-Consignee) Total 161619.36
Item Breakup - B1-SOR ITEM
Excavation and Casting of Main signal Numbers foundation as per Drg No SK 801 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.(Inspection Agency-Consignee)
Erection of CLS Post with Surface base and Numbers signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. (Inspection Agency- Consignee)
Hot dip Galvanizing as per RDSO Specn. ETI- Kg OHE-13 [4/84] - Signal post, OFF Set Brackets dia 140mm and length upto 5600 mm. (Inspection Agency-Consignee)
Excavation and Casting of Apparatus Case Numbers foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. Single Case as per Drg No . SK-803(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
"Excavation of cable trench as per cable route cum plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805(Inspection Agency-Consignee)"
"Excavation of cable trench as per cable route cum plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805(Inspection Agency-Consignee)"
"Cutting of all types of Roads/ platforms cum (except concrete type) for trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site. Drg. No. SK 807"
Digging of trench 1.0 M deep from rail cum flange/road level (for LC) and 0.3Mtrs. to 0.6 Mtrs wide and back filling after placing of DWC/RCC/GI pipe.(Placing of DWC/RCC/GI pipe covered separately. The ballast disturbed be screened and dressed as required by Engineer- in-charge or his representatives and road tarred immediately. Drg. No. SK 806(Inspection Agency-Consignee)
Laying of signalling/Power/Telecom cable of Kilometre various cores/sizes in trenches.(Inspection Agency-Consignee) Total 357834.06
Item Breakup - B2-SOR ITEM
Circuit wiring/jumpering as per circuit diagrams Numbers 1000.00 in the relay racks/IDF rack tagblocks. This includes preparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder rosin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways.(Inspection Agency- Consignee) (UNIT NUMBER SHOUDL BE READ AS JUMPER)
Plugging of relays, Provision for temporary Numbers relays for NI working if any, laying of temperory cables for mock panel and wiring of Mock panel. Panel through testing of PI/RRI as per selection table, control table etc. This also includes alteration if any in panel wiring, laying & termination of indoor cables from Panel to IDF/CT rack of relay room . Contractor shall depute Supervisor & wiremen technically qualified to carryout Panel through testing as per approved design. Technical knowledge of contractor's staff will be judged by Railways Engineer incharge before permiting them to do the testing. (Inspection Agency-Consignee) (UNIT NUMBER SHOUDL BE READ AS Route)
Relay Contact break test of indoor relay wiring. Numbers Contractor shall depute Engineer, Supervisor & wiremen technically qualified to carryout contact break testing as per approved circuit d i a g r a m s . Firm Engineer to sign circuit diagrams for break testing after carrying out the test in presence of Railway's site supervisor/Engineer. (Inspection Agency- Consignee) (UNIT NUMBER SHOUDL BE READ AS A3 Size circuite per Sheet)
Functional testing of PI/RRI/IBS/Autosignal etc. Numbers as per Selection table, control table, sqare sheet etc. Contractor shall depute one Engineer, one Supervisor & wiremen technically qualified to carryout functional testing as per approved design. Technical knowledge of contractor's staff will be judged by Railways Engineer incharge before permitting them to do the testing.(Inspection Agency-Consignee) (UNIT NUMBER SHOUDL BE READ AS Per route) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Preparation of cable route plan, cable coreage Lot plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size.The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways . This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P in consultation with engineer-in-charge. For small/medium yards (<= 100 routes) (Inspection Agency-Consignee)
Design and supply of Detailed Signalling Lot Circuits including Panel diagram(if required) , Route section Plan , Selection Table , Fuse & Negative Tag. Analysis , Contact analysis , Relay Rack Arrangement and wire count sheets etc. in A3 size.Completion circuit shall be plotted in AutoCAD. The contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits, complete for approval of Railways. Railways will return one set of circuit to the contractor duly approved with alterations /corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 6 sets of final approved circuits (out of which one set shall be supplied in transparent bags. Only two sheets of circuits shall be placed in one bag each ) shall be submitted to the Railways in case there are no further alteration suggested by Railways. This also includes modification in yard. for stations having Routes <= 50(Inspection Agency-Consignee)
Preparation of final ammonia prints of Lot diagrams in A-3 size after tracings are approved by Railways, in four sets for final submission with one set of diagram in transparent polythene bag/lamination (only two sheets shall be placed in one polythene bag/laminated each). Every set shall be set in a plastic folder of A3 size and of good quality. The final approved tracings will be handed over to contractor by railway for this purpose and contractor will return back the same after taking out the prints for stations having less than 20 routes. for stations having Routes <= 50(Inspection Agency-Consignee)
Excavation and Casting of main signal Lot foundation as per Drg No SK 801 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Excavation and Casting of Shunt signal Numbers foundation as per Drg No SK 802 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.(Inspection Agency-Consignee)
Erection of CLS Post with Surface base and Numbers signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. (Inspection Agency- Consignee)
Erection of shunt signal with Surface Base, Numbers Post, Signal unit and fixing of No.plates. The work shall be done as per instructions of Rly engineer at site. (Inspection Agency- Consignee)
Termination of tail cable on Main signal units Numbers and wiring with contractor own material, fixing of lenses etc. The work shall be done as per instruction of Rly engineer at site.(Inspection Agency-Consignee)
Termination of tail cable on Shunt signal units Numbers and wiring with contractor own material, fixing of lenses etc. The work shall be done as per instruction of Rly engineer at site.(Inspection Agency-Consignee)
Installation of ON/OFF aspect LED's in signal Numbers including termination of tail cable on signal, wiring, fixing of LED units and testing. The work shall be done as per instruction of Railway Engineer at site.(Inspection Agency-Consignee)
Fabrication laminated/Fibre glass sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of Rly engineer at site. Single Case(Inspection Agency-Consignee)
Fixing of cutting in relay bases & wiring of Numbers relays with Contractors own material obtained from approved sources in location box as per the instuctions of Engineer in charge. (Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Installation, wiring & testing / commissioning of Per Multi Section Digital Axle Counter's Central Detection Unit/Evaluator/Processor for the section /at Point (DP) station including its associated all indoor equipments, indication panel, monitoring console/interface computer and wiring the same to integrate with the relay circuits including supply of required power cable of multi -strand 10 Sq mm or more from power r o o m to Central Evaluator, 2 core shielded cable of required size copper conductor as per IRS (S) 76/89(Amd.3) or IS 694/2010 with latest amendment as applicable with other accessories as per the instructions of Railway Engineer at site and earthing as per OEM's technical requirement and specifications. This also includes laying & termination of cable if any from Panel Room to Axle Counter room /Relay room in DWC pipe with contractor's material / existing ladder. (Inspection Agency- Consignee)
Installation, wiring & testing / commissioning of Station Axle Counter's Reset Box of all types in Cabin/Panel room and wiring the same to integrate with the Axle counter as per the instructions of Railway Engineer at site. This includes laying & termination of cable if any form Panel Room/Axle Counter room /Relay r o o m to Reset Box in DWC pipe / existing ladder. (Inspection Agency-Consignee)
Installation of complete assembly of track Numbers device/double rail contact unit for entry or exist with conductors all material including drilling of required sizes holes on rails for fixing these, taking the cable lead through anti-rodent, anti- oxidnat & non-flame propagating type Double walled corrugated (DWC) pipe as per RDSO/SPN/204/2011 Ver.1.1 with Amd.1 or latest from track device to location box and terminating it on terminals including digging of trench under track and upto location/Track side unit and all other accessories as per site requirement for laying of transmitter and receiver cable with suitable wire embeded rubber pipe with clamp for protecting these cables at DP end.(Inspection Agency- Consignee) (UNIT NUMBER SHOUDL BE READ AS Per track device/double rail contact)
Installation of complete assembly of deflectors Per on either side of track device/double rail Detection contact unit including drilling of required sizes Point (DP) holes on rails for fixing these.(Inspection Agency-Consignee)
Fixing of point machine on newly laid turnout Numbers o n Wooden/MBC sleepers , fixing of ground connections, adjustment and testing with crank handle operations,Removal of ground connection & point machines duly numbered. This will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of holes to tounge rails, fitting of insulation for tounge attachment, gauge plate & stretcher bars, cable termination & wiring if required. The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site.(Inspection Agency- Consignee) (UNIT NUMBER SHOUDL BE READ AS PER T/O) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Installation, fixing and wiring of Boxes for Key Numbers Lock Relays with contractor's wiring and fixing material.The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site.(Inspection Agency-Consignee)
"Excavation of cable trench as per cable route cum plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805(Inspection Agency-Consignee)"
"Excavation of cable trench as per cable route cum plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be maden as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805(Inspection Agency-Consignee)"
"Cutting of all types of Roads/ platforms cum (except concrete type) for trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site. Drg. No. SK 807(Inspection Agency- Consignee)"
Digging of trench 1.0 M deep from rail cum flange/road level (for LC) and 0.3Mtrs. to 0.6 Mtrs wide and back filling after placing of DWC/RCC/GI pipe.(Placing of DWC/RCC/GI pipe coverd separately. The ballast disturbed be screened and dressed as required by Engineer- in-charge or his representatives and road tarred immediately. Drg. No. SK 806(Inspection Agency-Consignee)
Laying of DWC/RCC pipes alongwith collars/RCC Metre Half round pipes in trenches at places of track and road crossings, platform cuttings etc. (Inspection Agency-Consignee)
Laying of signalling/Power/Telecom cable of Kilometre various cores/sizes in trenches.(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Placing and securing of cable route markers in Numbers trenches at the specified interval and at diversions, joints etc along the cable route. The work shall be done as per extant practice on C Railways & the instruction of Rly engineer at site.(Inspection Agency-Consignee)
Lettering / Numbering of Signals, Point Numbers Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.(Inspection Agency-Consignee) Total 755432.78
Item Breakup - B3-SOR ITEM
Circuit wiring/jumpering as per circuit diagrams Numbers 2000.00 in the relay racks/IDF rack tagblocks. This includes preparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder rosin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways.(Inspection Agency- Consignee)(UNIT NUMBER SHOULD BE READ AS JUMPER)
Plugging of relays, Provision for temporary Numbers relays for NI working if any, laying of temperory cables for mock panel and wiring of Mock panel. Panel through testing of PI/RRI as per selection table, control table etc. This also includes alteration if any in panel wiring, laying & termination of indoor cables from Panel to IDF/CT rack of relay room . Contractor shall depute Supervisor & wiremen technically qualified to carryout Panel through testing as per approved design. Technical knowledge of contractor's staff will be judged by Railways Engineer incharge before permiting them to do the testing. (Inspection Agency-Consignee)UNIT NUMBER SHOULD BE READ AS Route)
Relay Contact break test of indoor relay wiring. Numbers Contractor shall depute Engineer, Supervisor & wiremen technically qualified to carryout contact break testing as per approved circuit d i a g r a m s . Firm Engineer to sign circuit diagrams for break testing after carrying out the test in presence of Railway's site supervisor/Engineer. (Inspection Agency- Consignee)(UNIT NUMBER SHOULD BE READ AS A3 Size circuite per Sheet)
Functional testing of PI/RRI/IBS/Autosignal etc. Numbers as per Selection table, control table, sqare sheet etc. Contractor shall depute one Engineer, one Supervisor & wiremen technically qualified to carryout functional testing as per approved design. Technical knowledge of contractor's staff will be judged by Railways Engineer incharge before permitting them to do the testing.(Inspection Agency-Consignee) (UNIT NUMBER SHOULD BE READ AS Per route) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Preparation of cable route plan, cable coreage Lot plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size.The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways . This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P in consultation with engineer-in-charge. For big yards (> 100 routes)(Inspection Agency- Consignee)
Design and supply of Detailed Signalling Lot Circuits including Panel diagram(if required) , Route section Plan , Selection Table , Fuse & Negative Tag. Analysis , Contact analysis , Relay Rack Arrangement and wire count sheets etc. in A3 size.Completion circuit shall be plotted in AutoCAD. The contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits, complete for approval of Railways. Railways will return one set of circuit to the contractor duly approved with alterations /corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 6 sets of final approved circuits (out of which one set shall be supplied in transparent bags. Only two sheets of circuits shall be placed in one bag each ) shall be submitted to the Railways in case there are no further alteration suggested by Railways. This also includes modification in yard. for stations having 101 - 200 routes(Inspection Agency-Consignee)
Preparation of final ammonia prints of Lot diagrams in A-3 size after tracings are approved by Railways, in four sets for final submission with one set of diagram in transparent polythene bag/lamination (only two sheets shall be placed in one polythene bag/laminated each). Every set shall be set in a plastic folder of A3 size and of good quality. The final approved tracings will be handed over to contractor by railway for this purpose and contractor will return back the same after taking out the prints for stations having less than 20 routes. for stations having 101 - 200 routes(Inspection Agency-Consignee)
Excavation and Casting of main signal Numbers foundation as per Drg No SK 801 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Excavation and Casting of Shunt signal Numbers foundation as per Drg No SK 802 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.(Inspection Agency-Consignee)
Erection of CLS Post with Surface base and Numbers signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. (Inspection Agency- Consignee)
Erection of shunt signal with Surface Base, Numbers Post, Signal unit and fixing of No.plates. The work shall be done as per instructions of Rly engineer at site. (Inspection Agency- Consignee)
Termination of tail cable on Main signal units Numbers and wiring with contractor own material, fixing of lenses etc. The work shall be done as per instruction of Rly engineer at site.(Inspection Agency-Consignee)
Termination of tail cable on Shunt signal units Numbers and wiring with contractor own material, fixing of lenses etc. The work shall be done as per instruction of Rly engineer at site.(Inspection Agency-Consignee)
Installation of ON/OFF aspect LED's in signal Numbers including termination of tail cable on signal, wiring, fixing of LED units and testing. The work shall be done as per instruction of Railway Engineer at site.(Inspection Agency-Consignee)
Fabrication laminated/Fibre glass sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of Rly engineer at site. Single Case(Inspection Agency-Consignee)
Fixing of cutting in relay bases & wiring of Numbers relays with Contractors own material obtained from approved sources in location box as per the instuctions of Engineer in charge. (Inspection Agency-Consignee)
Fixing of ARA Terminals and fuse blocks on Per phenolic laminated sheets and fixing by Conductor stainless steel/brass nuts & bolts.This includes provision of two additional holes on the board on either side for cable conductor entry. (Inspection Agency-Consignee)
Termination terminal/fuse blocks in the apparatus Cases/ Conductor cable termination rack.This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Excavation and Casting of Apparatus Case Numbers foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. Single Case as per Drg No . SK-803(Inspection Agency-Consignee)
Erection of Apparatus Cases. This includes Numbers filling of location foundations and plastering Single Case(Inspection Agency-Consignee)
Installation of Eqpt. (Relays, resistance, Numbers chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. Single Case(Inspection Agency-Consignee)
Installation, wiring & testing / commissioning of Per Multi Section Digital Axle Counter's Central Detection Unit/Evaluator/Processor for the section /at Point (DP) station including its associated all indoor equipments, indication panel, monitoring console/interface computer and wiring the same to integrate with the relay circuits including supply of required power cable of multi -strand 10 Sq mm or more from power r o o m to Central Evaluator, 2 core shielded cable of required size copper conductor as per IRS (S) 76/89(Amd.3) or IS 694/2010 with latest amendment as applicable with other accessories as per the instructions of Railway Engineer at site and earthing as per OEM's technical requirement and specifications. This also includes laying & termination of cable if any from Panel Room to Axle Counter room /Relay room in DWC pipe with contractor's material / existing ladder. (Inspection Agency- Consignee)
Installation, wiring & testing / commissioning of Station Axle Counter's Reset Box of all types in Cabin/Panel room and wiring the same to integrate with the Axle counter as per the instructions of Railway Engineer at site. This includes laying & termination of cable if any form Panel Room/Axle Counter room /Relay r o o m to Reset Box in DWC pipe / existing ladder. (Inspection Agency-Consignee)
Installation of complete assembly of track Numbers device/double rail contact unit for entry or exist with conductors all material including drilling of required sizes holes on rails for fixing these, taking the cable lead through anti-rodent, anti- oxidnat & non-flame propagating type Double walled corrugated (DWC) pipe as per RDSO/SPN/204/2011 Ver.1.1 with Amd.1 or latest from track device to location box and terminating it on terminals including digging of trench under track and upto location/Track side unit and all other accessories as per site requirement for laying of transmitter and receiver cable with suitable wire embeded rubber pipe with clamp for protecting these cables at DP end.(Inspection Agency- Consignee) (UNIT NUMBER SHOULD BE READ AS Per track device/double rail contact)
Installation of complete assembly of deflectors Per on either side of track device/double rail Detection contact unit including drilling of required sizes Point (DP) holes on rails for fixing these.(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Refixing of electrical point machine, ground Numbers connection during phase working (Non interlocked working) after removing the existing fitting if any, adjustment if necessary, cable termination,wiring , testing and commissioning of electrically operated point, fixing and connecting point indicator on derail switch if necessary. The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site.(Inspection Agency- Consignee) (UNIT NUMBER SHOULD BE READ AS PER T/O)
"Excavation of cable trench as per cable route cum plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805(Inspection Agency-Consignee)"
"Excavation of cable trench as per cable route cum plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be maden as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805(Inspection Agency-Consignee)"
Digging of trench 1.0 M deep from rail cum flange/road level (for LC) and 0.3Mtrs. to 0.6 Mtrs wide and back filling after placing of DWC/RCC/GI pipe.(Placing of DWC/RCC/GI pipe coverd separately. The ballast disturbed be screened and dressed as required by Engineer- in-charge or his representatives and road tarred immediately. Drg. No. SK 806(Inspection Agency-Consignee)
Laying of DWC/RCC pipes alongwith collars/RCC Metre Half round pipes in trenches at places of track and road crossings, platform cuttings etc. (Inspection Agency-Consignee)
Laying of signalling/Power/Telecom cable of Kilometre various cores/sizes in trenches.(Inspection Agency-Consignee)
Placing and securing of cable route markers in Numbers trenches at the specified interval and at diversions, joints etc along the cable route. The work shall be done as per extant practice on C Railways & the instruction of Rly engineer at site.(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Lettering / Numbering of Signals, Point Numbers Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.(Inspection Agency-Consignee)
Dismantling/Releasing of the existing outdoor Numbers signalling items such as CLS unit w i t h posts alongwith base, lever frames (5 levers set), battery box with equipments, location box with equipments, block instruments, point machines, mechanical point, AFTC/DAC, Relay rack, CT Rack alongwith Relay rack. IDF with all accessories. All these unit will be counted as one no. along with their accessories. This includes the cost of transportation of released material from site to Railway Scrap Depot. (Inspection Agency-Consignee) (UNIT NUMBER SHOULD BE READ AS Per Signal/Point/Loc. Box/ Relay Rack)
Transportation material/equipments including loading and u n lo a d in g in 10MT vehicle, anywhere to anywhere, and stacking at destination as per instructions of SSE in-charge as per inventory. For carrying heavy materials like cable drums, DG set, Electrical Lifting barrier pedestal, IPS, Batteries, Point machine etc.(Inspection Agency-Consignee) (UNIT NUMBER SHOULD BE READ AS Per Ton/ Per KM) Total 1467149.46
Item Breakup - B4-SOR ITEM
Circuit wiring/jumpering as per circuit diagrams Numbers 1000.00 in the relay racks/IDF rack tagblocks. This includes preparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder rosin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways.(Inspection Agency- Consignee)(Quantity Unit Number should be read as Jumper)
Plugging of relays, Provision for temporary Numbers relays for NI working if any, laying of temperory cables for mock panel and wiring of Mock panel. Panel through testing of PI/RRI as per selection table, control table etc. This also includes alteration if any in panel wiring, laying & termination of indoor cables from Panel to IDF/CT rack of relay room . Contractor shall depute Supervisor & wiremen technically qualified to carryout Panel through testing as per approved design. Technical knowledge of contractor's staff will be judged by Railways Engineer incharge before permiting them to do the testing. (Inspection Agency-Consignee) (Note=Quantity Unit Number should be read as Route) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Relay Contact break test of indoor relay wiring. Numbers Contractor shall depute Engineer, Supervisor & wiremen technically qualified to carryout contact break testing as per approved circuit d i a g r a m s . Firm Engineer to sign circuit diagrams for break testing after carrying out the test in presence of Railway's site supervisor/Engineer.(Inspection Agency- Consignee) (Note=Quantity Unit Number should be read as A3 Size circuite per Sheet)
Functional testing of PI/RRI/IBS/Autosignal etc. Per Route as per Selection table, control table, sqare sheet etc. Contractor shall depute one Engineer, one Supervisor & wiremen technically qualified to carryout functional testing as per approved design. Technical knowledge of contractor's staff will be judged by Railways Engineer incharge before permitting them to do the testing.(Inspection Agency-Consignee)
Preparation of cable route plan, cable coreage Lot plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size.The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways . This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P in consultation with engineer-in-charge. For big yards (> 100 routes)(Inspection Agency- Consignee)
Design and supply of Detailed Signalling Lot Circuits including Panel diagram(if required) , Route section Plan , Selection Table , Fuse & Negative Tag. Analysis , Contact analysis , Relay Rack Arrangement and wire count sheets etc. in A3 size.Completion circuit shall be plotted in AutoCAD. The contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits, complete for approval of Railways. Railways will return one set of circuit to the contractor duly approved with alterations /corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 6 sets of final approved circuits (out of which one set shall be supplied in transparent bags. Only two sheets of circuits shall be placed in one bag each ) shall be submitted to the Railways in case there are no further alteration suggested by Railways. This also includes modification in y a r d . for stations having 101 - 200 routes(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Preparation of final ammonia prints of Lot diagrams in A-3 size after tracings are approved by Railways, in four sets for final submission with one set of diagram in transparent polythene bag/lamination (only two sheets shall be placed in one polythene bag/laminated each). Every set shall be set in a plastic folder of A3 size and of good quality. The final approved tracings will be handed over to contractor by railway for this purpose and contractor will return back the same after taking out the prints for stations having less than 20 routes. for stations having 101 - 200 routes(Inspection Agency-Consignee)
Excavation and Casting of main signal Numbers foundation as per Drg No SK 801 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.(Inspection Agency-Consignee)
Excavation and Casting of Shunt signal Numbers foundation as per Drg No SK 802 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.(Inspection Agency-Consignee)
Erection of CLS Post with Surface base and Numbers signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. (Inspection Agency- Consignee)
Erection of shunt signal with Surface Base, Numbers Post, Signal unit and fixing of No.plates. The work shall be done as per instructions of Rly engineer at site.(Inspection Agency-Consignee)
Termination of tail cable on Main signal units Numbers and wiring with contractor own material, fixing of lenses etc. The work shall be done as per instruction of Rly engineer at site.(Inspection Agency-Consignee)
Termination of tail cable on Shunt signal units Numbers and wiring with contractor own material, fixing of lenses etc. The work shall be done as per instruction of Rly engineer at site.(Inspection Agency-Consignee)
Installation of ON/OFF aspect LED's in signal Numbers including termination of tail cable on signal, wiring, fixing of LED units and testing. The work shall be done as per instruction of Railway Engineer at site.(Inspection Agency-Consignee)
Fabrication laminated/Fibre glass sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of Rly engineer at site. Single Case(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Fixing of cutting in relay bases & wiring of Numbers relays with Contractors own material obtained from approved sources in location box as per the instuctions of Engineer in charge. (Inspection Agency-Consignee)
Fixing of ARA Terminals and fuse blocks on Per phenolic laminated sheets and fixing by Conductor stainless steel/brass nuts & bolts.This includes provision of two additional holes on the board on either side for cable conductor entry. (Inspection Agency-Consignee)
Termination terminal/fuse blocks in the apparatus Cases/ Conductor cable termination rack.This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.(Inspection Agency-Consignee)
Excavation and Casting of Apparatus Case Numbers foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. Single Case as per Drg No . SK-803(Inspection Agency-Consignee)
Erection of Apparatus Cases. This includes Numbers filling of location foundations and plastering Single Case(Inspection Agency-Consignee)
Installation of Eqpt. (Relays, resistance, Numbers chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. Single Case(Inspection Agency-Consignee)
Installation, wiring & testing / commissioning of Per Multi Section Digital Axle Counter's Central Detection Unit/Evaluator/Processor for the section /at Point (DP) station including its associated all indoor equipments, indication panel, monitoring console/interface computer and wiring the same to integrate with the relay circuits including supply of required power cable of multi -strand 10 Sq mm or more from power r o o m to Central Evaluator, 2 core shielded cable of required size copper conductor as per IRS (S) 76/89(Amd.3) or IS 694/2010 with latest amendment as applicable with other accessories as per the instructions of Railway Engineer at site and earthing as per OEM's technical requirement and specifications. This also includes laying & termination of cable if any from Panel Room to Axle Counter room /Relay room in DWC pipe with contractor's material / existing ladder. (Inspection Agency- Consignee)
Installation, wiring & testing / commissioning of Station Axle Counter's Reset Box of all types in Cabin/Panel room and wiring the same to integrate with the Axle counter as per the instructions of Railway Engineer at site. This includes laying & termination of cable if any form Panel Room/Axle Counter room /Relay r o o m to Reset Box in DWC pipe / existing ladder.(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Installation of complete assembly of track Numbers device/double rail contact unit for entry or exist with conductors all material including drilling of required sizes holes on rails for fixing these, taking the cable lead through anti-rodent, anti- oxidnat & non-flame propagating type Double walled corrugated (DWC) pipe as per RDSO/SPN/204/2011 Ver.1.1 with Amd.1 or latest from track device to location box and terminating it on terminals including digging of trench under track and upto location/Track side unit and all other accessories as per site requirement for laying of transmitter and receiver cable with suitable wire embeded rubber pipe with clamp for protecting these cables at DP end.(Inspection Agency- Consignee)(Note=Quantity Unit Number should be read as Per track device/double rail contact)
Installation of complete assembly of deflectors Per on either side of track device/double rail Detection contact unit including drilling of required sizes Point (DP) holes on rails for fixing these.(Inspection Agency-Consignee)
Refixing of electrical point machine, ground Numbers connection during phase working (Non interlocked working) after removing the existing fitting if any, adjustment if necessary, cable termination,wiring , testing and commissioning of electrically operated point, fixing and connecting point indicator on derail switch if necessary. The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site.(Inspection Agency- Consignee)(Note=Quantity Unit Number should be read as PER T/O)
"Excavation of cable trench as per cable route cum plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805(Inspection Agency-Consignee)" MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
"Excavation of cable trench as per cable route cum plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be maden as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805(Inspection Agency-Consignee)"
"Cutting of all types of Roads/ platforms cum (except concrete type) for trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site. Drg. No. SK 807(Inspection Agency- Consignee)"
Digging of trench 1.0 M deep from rail cum flange/road level (for LC) and 0.3Mtrs. to 0.6 Mtrs wide and back filling after placing of DWC/RCC/GI pipe.(Placing of DWC/RCC/GI pipe coverd separately. The ballast disturbed be screened and dressed as required by Engineer- in-charge or his representatives and road tarred immediately. Drg. No. SK 806(Inspection Agency-Consignee)
Laying of DWC/RCC pipes alongwith collars/RCC Metre Half round pipes in trenches at places of track and road crossings, platform cuttings etc. (Inspection Agency-Consignee)
Laying of signalling/Power/Telecom cable of Kilometre various cores/sizes in trenches.
Placing and securing of cable route markers in Numbers trenches at the specified interval and at diversions, joints etc along the cable route. The work shall be done as per extant practice on C Railways & the instruction of Rly engineer at site.(Inspection Agency-Consignee)
Lettering / Numbering of Signals, Point Numbers Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.(Inspection Agency-Consignee)
Dismantling/Releasing of the existing outdoor Numbers signalling items such as CLS unit w i t h posts alongwith base, lever frames (5 levers set), battery box with equipments, location box with equipments, block instruments, point machines, mechanical point, AFTC/DAC, Relay rack, CT Rack alongwith Relay rack. IDF with all accessories. All these unit will be counted as one no. along with their accessories. This includes the cost of transportation of released material from site to Railway Scrap Depot. (Inspection Agency-Consignee)(Note=Quantity Unit Number should be read asPer Signal/Point/Loc. Box/ Relay Rack) Total 1501097.00 MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Item Breakup - B5-SOR ITEM
Excavation and Casting of Main signal Numbers foundation as per Drg No SK 801 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.(Inspection Agency-Consignee)
Erection of CLS Post with Surface base and Numbers signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. (Inspection Agency- Consignee)
Hot dip Galvanizing as per RDSO Specn. ETI- Kg OHE-13 [4/84] - Signal post, OFF Set Brackets dia 140mm and length upto 5600 mm. (Inspection Agency-Consignee)
Excavation and Casting of Apparatus Case Numbers foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. Single Case as per Drg No . SK-803(Inspection Agency-Consignee)
"Excavation of cable trench as per cable route cum plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805(Inspection Agency-Consignee)"
"Excavation of cable trench as per cable route cum plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805(Inspection Agency-Consignee)" MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
"Cutting of all types of Roads/ platforms cum (except concrete type) for trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site. Drg. No. SK 807(Inspection Agency- Consignee)"
Digging of trench 1.0 M deep from rail cum flange/road level (for LC) and 0.3Mtrs. to 0.6 Mtrs wide and back filling after placing of DWC/RCC/GI pipe.(Placing of DWC/RCC/GI pipe covered separately. The ballast disturbed be screened and dressed as required by Engineer- in-charge or his representatives and road tarred immediately. Drg. No. SK 806(Inspection Agency-Consignee)
Laying of signalling/Power/Telecom cable of Kilometre various cores/sizes in trenches.(Inspection Agency-Consignee) Total 357834.06
Item Breakup - C1-NON SOR ITEM
Supply of AC & DC low current clamp meter Numbers with range 1 mA to 60 A or higher; make GTC CM 100, KIOKO, Stanley, Amprobe.(Inspection Agency-Consignee)
Supply of counting head ZP 43 V complete with Numbers sensor for Siemens make MSDAC(Inspection Agency-Consignee)
Evaluation computer EC4 for SIEMENS Make Numbers MSDAC(Inspection Agency-Consignee)
Repairing of location foundation with masonary Numbers work. This also includes cleaning the locations, sand filling in the location and plastering inside the location(Inspection Agency-Consignee)
Execution of S & T work related toenginnering Job /Signalling block ofCTR/TTR/TSR or others, in one block,five unskilled manpower have to beprovided during block for S&Tconnection removing & refixing as perRailway site engineer instruction.(Inspection Agency-Consignee)
Casting of cement concrete to protect S&T cum equipments and laid cables, above pipes etc by concrete mixture of cement, sand, stone in theratio of 1:2:4 using 25 mmgraded stone aggregate asper instruction of site incharge of railways. Concreteis to be casted with the helpof suitable size shutteringform as per site requirement.Concrete is to be cured for sufficient time as per standard practices on railways(Inspection Agency-Consignee) Total 2982479.97
Item Breakup - C2-NON SOR ITEM
Casting of cement concrete to protect S&T cum equipments and laid cables, above pipes etc by concrete mixture of cement, sand, stone in theratio of 1:2:4 using 25 mmgraded stone aggregate asper instruction of site incharge of railways. Concreteis to be casted with the helpof suitable size shutteringform as per site requirement.Concrete is to be cured for sufficient time as per standard practices on railwaysv(Inspection Agency-Consignee)
Supply of cable route marker as per RST/C/203 Numbers of FRP(Inspection Agency-Consignee)
WELD LESS MODULAR TYPE SS MEDUIM SIZE Numbers LOCATION BOX(Inspection Agency-Consignee)
Digital current clamp meter to measure current Numbers leaks parasitic draws down to 1 mA and electric load from 1 mA to 100 Amp AC/DC, and voltages from 0 to 600 V AC/DC, small jaw size to measure current in signaling circuits, 4 digit display. make FLUKE/ GTC/KIOCO or superior with better specification mentioned with all accessories like test lead, batteries and carrying case, sample may got approved from consignee before supply. (Inspection Agency- Consignee)
Repairing masonarywork. This also includescleaning the locations, sandfilling in the location andplastering inside the location(Inspection Agency-Consignee)
Providing Road Breaker/concrete breaker with Numbers compressor & Jack Hammer for Railway work such as cutting & dismantling of road concrete/Brick pucca structure (RCC/Steel section) including contractors fuel, driver and all other charges completed as directed by Engg in charge. (UNIT NUMBER SHOULD BE READ AS PER HOUR)(Inspection Agency- Consignee)
Execution of S & T work related to Job enginnering/Signalling block ofCTR/TTR/TSR or others, inone block, five unskilledmanpower have to beprovided during block for S&Tconnection removing &refixing as per Railway siteengineer instruction.(Inspection Agency-Consignee) Total 977299.80
Item Breakup - C3-NON SOR ITEM
Silicon Sealent (Odorless, Clear) in a tube of Numbers 300 ml of DOW Corning Product No. 733 or master Bond Product - master SIL 415 or Boss Product - Boss 332 or Anabond RTV Silicones 666 or Dowsil(Inspection Agency-Consignee)
Execution of S & T work related to Job enginnering/Signalling block ofCTR/TTR/TSR or others, inone block, five unskilledmanpower have to beprovided during block for S&Tconnection removing &refixing as per Railway siteengineer instruction.(Inspection Agency-Consignee)
Supply of cable route marker as per RST/C/203 Numbers of FRP(Inspection Agency-Consignee)
WELD LESS MODULAR TYPE SS MEDUIM SIZE Numbers LOCATION BOX(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Wheel sensor with protection tube of Frauscher Numbers make MSDAC type Rsr 180 (with BBIK- M 12 GS05 fixing along with cable length of 5 mtr (GS05)(Inspection Agency-Consignee)
Wheel sensor with protection tube of Frauscher Numbers make MSDAC type Rsr 180 (with BBIK- M 12 GS05 fixing along with cable length of 10 mtr (GS05)(Inspection Agency-Consignee)
Wheel sensor with protection tube of Frauscher Numbers make MSDAC type Rsr 180 (with BBIK- M 12 GS05 fixing along with cable length of 15 mtr (GS05)(Inspection Agency-Consignee)
Digital current clamp meter to measure current Numbers leaks parasitic draws down to 1 mA and electric load from 1 mA to 100 Amp AC/DC, and voltages from 0 to 600 V AC/DC, small jaw size to measure current in signaling circuits, 4 digit display. make FLUKE/ GTC/KIOCO or superior with better specification mentioned with all accessories like test lead, batteries and carrying case, sample may got approved from consignee before supply. (Inspection Agency- Consignee)
Casting of cement concrete to protect S&T cum equipments and laid cables, above pipes etc by concrete mixture of cement, sand, stone in theratio of 1:2:4 using 25 mmgraded stone aggregate asper instruction of site incharge of railways. Concreteis to be casted with the helpof suitable size shutteringform as per site requirement.Concrete is to be cured for sufficient time as per standard practices on railways(Inspection Agency-Consignee)
Repairing of location foundation with masonary Numbers work. This also includes cleaning the locations, sand filling in the location and plastering inside the location(Inspection Agency-Consignee) Q Total 2207906.50
Item Breakup - C4-NON SOR ITEM
Supply of cable route marker as per RST/C/203 Numbers of FRP(Inspection Agency-Consignee)
WELD LESS MODULAR TYPE SS MEDUIM SIZE Numbers LOCATION BOX(Inspection Agency-Consignee)
Digital current clamp meter to measure current Numbers leaks parasitic draws down to 1 mA and electric load from 1 mA to 100 Amp AC/DC, and voltages from 0 to 600 V AC/DC, small jaw size to measure current in signaling circuits, 4 digit display. make FLUKE/ GTC/KIOCO or superior with better specification mentioned with all accessories like test lead, batteries and carrying case, sample may got approved from consignee before supply. (Inspection Agency- Consignee)
Repairing of location foundation with masonary Numbers work. This also includes cleaning the locations, sand filling in the location and plastering inside the location(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Providing Road Breaker/concrete breaker with Numbers compressor & Jack Hammer for Railway work such as cutting & dismantling of road concrete/Brick pucca structure (RCC/Steel section) including contractors fuel, driver and all other charges completed as directed by Engg in charge. (UNIT NUMBER SHOULD BE READ AS PER HOUR)(Inspection Agency- Consignee)
Execution of S & T work related to enginnering Job block of CTR/TTR/TSR or others, in one block, five unskilled manpower have to be provided during block for S&T connection removing & refixing as per Railway site engineer instruction.(Inspection Agency-Consignee)
Casting of cement concrete to protect S&T cum equipments and laid cables, above pipes, Signal store etc by concrete mixture of cement, sand, stone in the ratio of 1:2:4 using 25 mm graded stone aggregate as per instruction of site in charge of railways. Concrete is to be casted with the help of suitable size shuttering form as per site requirement. Concrete is to be cured for sufficient time as per standard practices on railways(Inspection Agency- Consignee) Total 846284.30
Item Breakup - C5-NON SOR ITEM
Supply of AC & DC low current clamp meter Numbers with range 1 mA to 60 A or higher; make GTC CM 100, KIOKO, Stanley, Amprobe.(Inspection Agency-Consignee)
Wheel sensor with protection tube of Frauscher Numbers make MSDAC type Rsr 180 (with BBIK- M 12 GS05 fixing along with cable length of 5 mtr (GS05)(Inspection Agency-Consignee)
Wheel sensor with protection tube of Frauscher Numbers make MSDAC type Rsr 180 (with BBIK- M 12 GS05 fixing along with cable length of 10 mtr (GS05)(Inspection Agency-Consignee)
Wheel sensor with protection tube of Frauscher Numbers make MSDAC type Rsr 180 (with BBIK- M 12 GS05 fixing along with cable length of 15 mtr (GS05)(Inspection Agency-Consignee)
Track side Electronic Unit (EAK) for MSDAC as Numbers perRDSO Spec No.:RDSO/SPN/176/2013 Ver.- 3Make:ELDYNE only.(Inspection Agency- Consignee)
Mother Board for 3CRo1838AAAA makeEldyne(Inspection Agency-Consignee)
Repairing of location foundation with masonary Numbers work. This also includes cleaning the locations, sand filling in the location and plastering inside the location(Inspection Agency-Consignee)
Execution of S & T work related toenginnering Job /Signalling block ofCTR/TTR/TSR or others, in one block,five unskilled manpower have to beprovided during block for S&Tconnection removing & refixing as perRailway site engineer instruction.(Inspection Agency-Consignee) MUMBAI-CST-DIVISION-S AND T/CENTRAL RLY
Casting of cement concrete to protect S&T cum equipments and laid cables, above pipes etc by concrete mixture of cement, sand, stone in theratio of 1:2:4 using 25 mmgraded stone aggregate asper instruction of site incharge of railways. Concreteis to be casted with the helpof suitable size shutteringform as per site requirement.Concrete is to be cured for sufficient time as per standard practices on railways(Inspection Agency-Consignee) Total 2981963.87
Item Breakup - D4-NON SOR ITEM
"Supply of Digital Axle Counter Multi section Numbers type complete sysem including the Central Evaluator and final track clearance relay for each secton, Reset boxes, LV boxes, All track side units with detection point complete assembly & fixing arrangement for each detection point, clamps deflector for either side of each detection points, monitoring console for monitoring all the DPs at a time installed at a station/ RH/IBH etc. with all other accessories fully wired and fully equipped as per RDSO specification No.RDSO/ SPN/176/2013 (ver.3) or latest and manufacturers specification. The equipment must also include the following : a) System must have remote monitoring and health diagnostics feature as per RDSO specification. b) Surge protection device. c) 20% spare slots for the both detection heads and track section in the evaluator for future and emergenc provision. Each set also consisting of a) Double rail contact of standard length of cable as per site requirement and mounting accessories - Equal to no. of DP. b) Deflectors to safeguard Rail Contact will be TWICE the no. of DPs. c) Protecting tube from DP to railhead as per requirement. d) Diagnostic PC as per specification and other accessories (as per Annexure-VI) e) Pre-wired cabinet/rack no. as per site requirement. f) 6 Nos. Electrostatic Discharge Wrist Band for cards/ modules protection.(Inspection Agency- Consignee) " Total 4704080.40
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .